Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2603.26398

In-Situ Differential-Light-Shift Cancellation for Trapped-Atom Clocks

Jan Simon Haase, Alexander Fieguth, Igor Bröckel, Jens Kruse, Carsten Klempt

physics.atom-phquant-phSubmitted Mar 27, 2026• Announced Mar 30, 2026• 0 citations
v1 · Mar 27, 2026v2 · Oct 21, 2026
arXivHTMLPDF

Abstract

Differential light shifts (DLS) induced by optical trapping fields fundamentally limit the stability and accuracy of trapped-atom microwave clocks. We demonstrate an in-situ method to cancel DLS by simultaneously interrogating multiple spatially separated atomic ensembles at different trap intensities generated from a common light source. By operating the ensembles at set intensity ratios and performing Ramsey spectroscopy, the intensity-dependent frequency shifts are measured within each experimental cycle and extrapolated to the zero-intensity limit. This approach effectively enables shot-to-shot determination of a DLS-free frequency without requiring magic wavelengths or species-specific cancellation schemes. We validate the method for Rb atoms trapped in time-averaged potentials by introducing controlled variations of the total trap power and show that the extrapolated frequency remains insensitive to these fluctuations. The technique is general and can be extended to other systematic shifts, providing a scalable route toward improved stability and accuracy in compact trapped-atom clocks and related quantum sensors relying on optical dipole traps

Related papers

Suppressing the dephasing of optically trapped atoms inside a hollow-core fiber

Yitong Song, Wei Li, Xiaobin Xu +4 more

Rb atoms optically trapped inside a hollow-core fiber. The differential light shift (DLS) for the clock transition caused by the trapping beam is reduced by one order of magnitude through the use of a weak compensation laser beam that is spatially mode-matched to the trapping beam. The coherence of the DLS-compensated system is characterized by microwave Ramsey interferometry, which shows Ramsey fringes with a contrast of over 0.6 at a separation time of 10 ms. The dephasing time, measured by Ramsey spectroscopy at different separation times, reaches tens of milliseconds after DLS cancellation, limited by the residual DLS caused by mode mismatching between the two laser beams. This work paves the way for compact and portable fiber-guided atom interferometers.

Optics Letters•Nov 29, 2023•5 citations

Differential Light-Shift Cancellation in a Magnetic-Field-Insensitive Transition of Rb87

Radu Chicireanu, K. D. Nelson, Steven Olmschenk +3 more

The precise measurement of transition frequencies of trapped atomic samples is susceptible to inaccuracy arising from the inhomogeneous differential shift of the relevant energy levels in the presence of the trapping fields. We demonstrate near-complete cancellation of the differential ac Stark shift ("light shift") of a two-photon magnetic-field-insensitive microwave hyperfine (clock) transition in ^{87}Rb atoms trapped in an optical lattice. Up to 95(2)% of the differential light shift is cancelled while maintaining magnetic-field insensitivity. This technique should have applications in quantum information and frequency metrology.

arXiv:1010.1520•Physical Review Letters•Feb 8, 2011•42 citations

Autobalanced Ramsey Spectroscopy Improving Clock Accuracy and Testing Fundamental Physics

Christian Sanner, Nils Huntemann, R. Lange +2 more

Everyone is trying to make frequency measurements as accurate as possible. But what if the measurement process itself becomes a major source of error? This issue is particularly relevant in the context of state-of-the-art atomic clocks where errors at the 18th decimal place are not negligible anymore. In order to spectroscopically interrogate an atomic clock transition without compromising the clock's accuracy, we devise a perturbation-immune version of Ramsey's method of separated oscillatory fields. By actively balancing the spectroscopic responses from phase-congruent Ramsey probe cycles of unequal durations, we eliminate a wide variety of interrogation-induced line shifts often encountered in high precision spectroscopy, among them, in particular, light shifts, phase chirps, and transient Zeeman shifts. We experimentally demonstrate autobalanced Ramsey spectroscopy on the light shift prone171Yb+electric octupole optical clock transition and show that interrogation defects are not turned into clock errors. This opens up frequency accuracy perspectives below the 10-18level for the Yb+system and for other types of optical clocks. Further applications of this simple and universal approach include next generation coherent population trapping clocks and perturbation-immune readout of quantum sensors. Future long-term clock comparisons searching for physics beyond the standard model will also benefit from this technique.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2019•0 citations

Reduction of light shifts in a cold-atom CPT clock

Maojie Li, Zhu Ma, Jiatao Wu +5 more

Abstract Light shifts induced during atom–light interactions significantly affect the medium- and long-term frequency stability of atomic clocks. Here, we employ composite laser pulse sequences to mitigate interrogation-induced light shifts in a cold-atom coherent-population-trapping clock. We obtain the anti-symmetry error signal via modulating the local oscillator phase in the free-evolution time of Ramsey interferometry. Utilizing this signal, we employ two feedback loops to simultaneously eliminate light shifts and stabilize the clock frequency using the auto-balanced Ramsey (ABR) spectroscopy scheme. Our experimental results demonstrate that this approach can reduce the clock frequency’s sensitivity to variations in light shifts by implementing four Ramsey sub-sequences. Furthermore, we show that the ABR spectroscopy scheme enhances the long-term frequency stability of the atomic clock when the averaging time τ > 5000 s.

Journal of Physics B Atomic Molecular and Optical Physics•Apr 23, 2024•4 citations

Experimental Observation of Magic-Wavelength Behavior in Optical Lattice-Trapped 87 Rb | NIST

J. V. Porto, Nathan E. Lundblad, Malte Schlosser

We demonstrate the cancellation of the differential ac Stark shift of the microwave hyperfine clock transition in trapped 87 Rb atoms. Recent progress in metrology exploits so-called “magic wavelengths,” whereby an atomic ensemble can be trapped with laser light whose wavelength is chosen so that both levels of an optical atomic transition experience identical ac Stark shifts. Similar magic-wavelength techniques are not possible for the microwave hyperfine transitions in the alkalis, due to their simple electronic structure. We show, however, that ac Stark shift cancellation is indeed achievable for certain values of wavelength, polarization, and magnetic field. The cancellation comes at the expense of a small magnetic-field sensitivity. The technique demonstrated here has implications for experiments involving the precise control of optically-trapped neutral atoms.

Physical Review Letters•Mar 29, 2010•1 citation

Ramsey Imaging of Optical Traps

Gautam Ramola, Richard Winkelmann, Karthik Chandrashekara +4 more

The mapping of the potential landscape with high spatial resolution is crucial for quantum technologies based on ultracold atoms. However, the imaging of optical dipole traps is challenging because purely optical methods, commonly used to profile laser beams in free space, are not applicable in a vacuum. In this work, we demonstrate precise in situ imaging of optical dipole traps by probing a hyperfine transition with Ramsey interferometry. Thereby, we obtain an absolute map of the potential landscape with micrometer resolution and shot-noise-limited spectral precision. The idea of the technique is to control the polarization ellipticity of the trap laser beam to induce a differential light shift proportional to the trap potential. By studying the response to polarization ellipticity, we uncover a small but significant nonlinearity in addition to a dominant linear behavior, which is explained by the geometric distribution of the atomic ensemble. Our technique for imaging of optical traps can find wide application in quantum technologies based on ultracold atoms, as it applies to multiple atomic species and is not limited to a particular wavelength or trap geometry.

arXiv:2106.05871•Physical Review Applied•Aug 24, 2021•10 citations
Differential light shifts (DLS) induced by optical trapping fields fundamentally limit the stability and accuracy of trapped-atom microwave clocks. We demonstrate an in-situ method to cancel DLS by simultaneously interrogating multiple spatially separated atomic ensembles at different trap intensities generated from a common light source. By operating the ensembles at set intensity ratios and performing Ramsey spectroscopy, the intensity-dependent frequency shifts are measured within each experimental cycle and extrapolated to the zero-intensity limit. This approach effectively enables shot-to-shot determination of a DLS-free frequency without requiring magic wavelengths or species-specific cancellation schemes. We validate the method for Rb atoms trapped in time-averaged potentials by introducing controlled variations of the total trap power and show that the extrapolated frequency remains insensitive to these fluctuations. The technique is general and can be extended to other systematic shifts, providing a scalable route toward improved stability and accuracy in compact trapped-atom clocks and related quantum sensors relying on optical dipole traps
Rb atoms optically trapped inside a hollow-core fiber. The differential light shift (DLS) for the clock transition caused by the trapping beam is reduced by one order of magnitude through the use of a weak compensation laser beam that is spatially mode-matched to the trapping beam. The coherence of the DLS-compensated system is characterized by microwave Ramsey interferometry, which shows Ramsey fringes with a contrast of over 0.6 at a separation time of 10 ms. The dephasing time, measured by Ramsey spectroscopy at different separation times, reaches tens of milliseconds after DLS cancellation, limited by the residual DLS caused by mode mismatching between the two laser beams. This work paves the way for compact and portable fiber-guided atom interferometers.
The precise measurement of transition frequencies of trapped atomic samples is susceptible to inaccuracy arising from the inhomogeneous differential shift of the relevant energy levels in the presence of the trapping fields. We demonstrate near-complete cancellation of the differential ac Stark shift ("light shift") of a two-photon magnetic-field-insensitive microwave hyperfine (clock) transition in ^{87}Rb atoms trapped in an optical lattice. Up to 95(2)% of the differential light shift is cancelled while maintaining magnetic-field insensitivity. This technique should have applications in quantum information and frequency metrology.
Everyone is trying to make frequency measurements as accurate as possible. But what if the measurement process itself becomes a major source of error? This issue is particularly relevant in the context of state-of-the-art atomic clocks where errors at the 18th decimal place are not negligible anymore. In order to spectroscopically interrogate an atomic clock transition without compromising the clock's accuracy, we devise a perturbation-immune version of Ramsey's method of separated oscillatory fields. By actively balancing the spectroscopic responses from phase-congruent Ramsey probe cycles of unequal durations, we eliminate a wide variety of interrogation-induced line shifts often encountered in high precision spectroscopy, among them, in particular, light shifts, phase chirps, and transient Zeeman shifts. We experimentally demonstrate autobalanced Ramsey spectroscopy on the light shift prone171Yb+electric octupole optical clock transition and show that interrogation defects are not turned into clock errors. This opens up frequency accuracy perspectives below the 10-18level for the Yb+system and for other types of optical clocks. Further applications of this simple and universal approach include next generation coherent population trapping clocks and perturbation-immune readout of quantum sensors. Future long-term clock comparisons searching for physics beyond the standard model will also benefit from this technique.
Abstract Light shifts induced during atom–light interactions significantly affect the medium- and long-term frequency stability of atomic clocks. Here, we employ composite laser pulse sequences to mitigate interrogation-induced light shifts in a cold-atom coherent-population-trapping clock. We obtain the anti-symmetry error signal via modulating the local oscillator phase in the free-evolution time of Ramsey interferometry. Utilizing this signal, we employ two feedback loops to simultaneously eliminate light shifts and stabilize the clock frequency using the auto-balanced Ramsey (ABR) spectroscopy scheme. Our experimental results demonstrate that this approach can reduce the clock frequency’s sensitivity to variations in light shifts by implementing four Ramsey sub-sequences. Furthermore, we show that the ABR spectroscopy scheme enhances the long-term frequency stability of the atomic clock when the averaging time τ > 5000 s.
We demonstrate the cancellation of the differential ac Stark shift of the microwave hyperfine clock transition in trapped 87 Rb atoms. Recent progress in metrology exploits so-called “magic wavelengths,” whereby an atomic ensemble can be trapped with laser light whose wavelength is chosen so that both levels of an optical atomic transition experience identical ac Stark shifts. Similar magic-wavelength techniques are not possible for the microwave hyperfine transitions in the alkalis, due to their simple electronic structure. We show, however, that ac Stark shift cancellation is indeed achievable for certain values of wavelength, polarization, and magnetic field. The cancellation comes at the expense of a small magnetic-field sensitivity. The technique demonstrated here has implications for experiments involving the precise control of optically-trapped neutral atoms.
The mapping of the potential landscape with high spatial resolution is crucial for quantum technologies based on ultracold atoms. However, the imaging of optical dipole traps is challenging because purely optical methods, commonly used to profile laser beams in free space, are not applicable in a vacuum. In this work, we demonstrate precise in situ imaging of optical dipole traps by probing a hyperfine transition with Ramsey interferometry. Thereby, we obtain an absolute map of the potential landscape with micrometer resolution and shot-noise-limited spectral precision. The idea of the technique is to control the polarization ellipticity of the trap laser beam to induce a differential light shift proportional to the trap potential. By studying the response to polarization ellipticity, we uncover a small but significant nonlinearity in addition to a dominant linear behavior, which is explained by the geometric distribution of the atomic ensemble. Our technique for imaging of optical traps can find wide application in quantum technologies based on ultracold atoms, as it applies to multiple atomic species and is not limited to a particular wavelength or trap geometry.