Spin relaxometry using solid-state spin defects, such as the diamond nitrogen-vacancy (NV) center, probes dynamical processes by measuring how environmental fluctuations enhance the spin relaxation rate. In the weak-coupling limit, relaxation rates sample the transverse magnetic-noise power spectral density through a sensor-specific filter function, turning the defect into a local, frequency-selective noise spectrometer. This review bridges theory and experiment, clarifying how measured relaxation rates map onto noise spectra and how near-field geometry shapes the response. We highlight representative applications across condensed-matter physics, chemical and biological sensing, and relaxometry-based magnetic-resonance spectroscopy. We conclude with emerging opportunities and key challenges.
Spin relaxometry using solid-state spin defects, such as the diamond nitrogen-vacancy (NV) center, probes dynamical processes by measuring how environmental fluctuations enhance the spin relaxation rate. In the weak-coupling limit, relaxation rates sample the transverse magnetic-noise power spectral density through a sensor-specific filter function, turning the defect into a local, frequency-selective noise spectrometer. This review bridges theory and experiment, clarifying how measured relaxation rates map onto noise spectra and how near-field geometry shapes the response. We highlight representative applications across condensed-matter physics, chemical and biological sensing, and relaxometry-based magnetic-resonance spectroscopy. We conclude with emerging opportunities and key challenges.
Quantum sensing using nitrogen-vacancy (NV) centers in diamond has emerged as a powerful platform for detecting ultra-low magnetic fields under ambient conditions. Owing to their long spin coherence times, optical addressability, and compatibility with aqueous environments, it has found widespread applications in biosensing and bio-imaging. This review presents the fundamental principles and recent advances in NV-based quantum magnetometry for biosensing applications, with a particular focus on measurements in aqueous medium and at cellular and molecular length scales. We discuss the underlying spin physics of NV centers and highlight two primary detection modalities: optically detected magnetic resonance (ODMR) and T1 relaxometry-based sensing and how these approaches aids in the detection of both static magnetic fields and dynamic magnetic noise arising from biological processes. The review explores key application areas, including nanoscale nuclear magnetic resonance (NMR), monitoring of neural activity, detection of abnormal or rogue cells using NV-based platforms etc. In addition, strategies for enhancing sensitivity, such as surface functionalization of nanodiamonds, femtosecond (fs) laser-written photonic structures, and integration with microfluidic and lab-on-chip systems have also been discussed in depth. We also address the critical challenges, including surface-induced decoherence, charge-state instability, and signal-to-noise limitations in biofluids associated with NV-based biosensing applications. Finally, we outline future prospects, highlighting how NV-based magnetic biosensing provides a promising pathway for translating quantum sensing technologies into practical biomedical applications.
Quantum relaxometry is one of the most successful applications of nitrogen-vacancy (NV) centers in diamond and, more broadly, solid-state spin qubits, enabling ultrasensitive detection of magnetic noise and paramagnetic species via measurements of the spin-lattice relaxation time T1. Conventional pulsed protocols, however, probe T1 efficiently only over a limited temporal range, which restricts the scope and throughput of the technique. Here we introduce a continuous-wave quantum relaxometry protocol that operates in the frequency domain. By measuring the frequency response of the optically detected magnetic resonance signal under low-frequency microwave amplitude modulation, we extract T1 from the characteristic response time of the spin system. The method enables efficient T1 measurements spanning more than three orders of magnitude -- directly demonstrated from 60 μs to 200 ms in our experiments -- across a broad temperature range and under substantial ensemble inhomogeneity. We further show that this protocol enables quantitative relaxometry-based sensing in nanodiamonds, achieving a substantial speed-up over the pulsed methods and offering a practical approach to optimizing nanodiamond size for enhanced sensitivity.
This thesis investigates the use of the Nitrogen Vacancy (NV) centre in diamond as a novel sensor for magnetic resonance spectroscopy on the nanoscale. The need for novel nanoscale sensors of nuclear spins, for the application of nuclear magnetic resonance (NMR), and electron spins, for the application electron paramagnetic resonance (EPR), has been well established in recent decades. The nanoscale resolution, magnetic sensitivity, room temperature operation and optical initialisation and readout of the NV centre has led to it being of intense interest for this purpose. The biological compatibility of diamond strengthens the utility of the NV centre for interesting EPR and NMR applications. Existing techniques for EPR and NMR with the NV centre have focused on dynamically controlling the NV spin, and at times the environmental target spin, in order to match the frequency selectivity of the NV centre to the environmental spin species. However this introduces both physical and technical complexities on the measurement which can limit the applicability to certain, highly interesting applications. While microwave control of the NV centre looks a promising technology in the highly controlled lab environment for targetting applications such as protein structure determination, the requirement for control of both the static magnetic field and the strength of the microwave driving field are significant difficulties for more complex environments, such as potential in-vitro or in-vivo applications. This thesis is a detailed investigation of a new method of nanoscale EPR and NMR with the NV centre where we apply a precise static magnetic field to tune the NV into resonance with the environmental spin species. We can then measure this resonance via the reduced axial relaxation time, T1. We investigate the theoretical possibility and then conduct an experimental demonstration of both EPR and NMR in this way at the nanoscale with a single NV centre. Initially, in Chapter 2, we consider the theoretical application of T1 spectroscopy both to a classical noise signal and also, with a fully quantum treatment, to a single environmental spin. In addition, we detail the experimental setup used subsequently for implementing T1 spectroscopy. As an initial investigation, in Chapter 3, we map the spectrum of the substitutional Nitrogen defect (P1 centre) within diamond and compare this method to the current state-of-the-art techniques for nanoscale EPR with the NV centre. Furthermore we map the nuclear transitions of the P1 centres and demonstrate how the nuclear spin signal is enhanced by the strongly interacting electron spin of the P1 centre, thus providing a method for hyperfine-assisted NMR. After demonstrating our technique on an electronic spin system within the diamond lattice, we look to extend the technique to general nuclear spins external to the diamond surface in Chapter 4. This entails an extensive investigation of the NV centre's behaviour near the ground state level anticrossing (GSLAC) during which we demonstrate all-optical nanoscale AC magnetometry down to sub MHz level. Subsequently, we are able to demonstrate all-optical nanoscale NMR on proton spins external to the diamond surface and show that this technique achieves similar sensitivity to current techniques while removing the requirement for complex microwave pulsing of the NV centre. Finally, in Chapter 5, we look at how the ability to directly tune the NV into resonance with environmental spins allows for hyperpolarisation of the surrounding spin bath. Via the same mechanism used for the magnetic resonance spectroscopy studies, we show that the 13C nuclear spins within the diamond lattice can be polarised with high eficiency via this direct crossrelaxation. This work shows that coupling the NV centre to environmental spins simply via a static magnetic field is possible, opening up a new avenue for future sensing with the Nitrogen-Vacancy centre in diamond.
Nitrogen-vacancy (NV) defect centers in diamond have generated much interest for their uses in quantum information and sensing. Despite the ongoing improvements in sensitivity and the range of new applications, much about the NV basic physics remains unresolved, which is important to understand in order to fully exploit potential uses. In this work I describe a series of experiments on NV basic properties, applications, and projects in between. First, I describe an NV singlet absorption spectroscopy experiment, which searched for additional NV electronic states and studied the 1A1 phonon modes. Next, I discuss an NV microwave saturation spectroscopy experiment, which is useful for NV thermometry, removes inhomogeneous broadening, and can yield information about diamond magnetic spin bath dynamics. I then describe an NV relaxation experiment that senses GHz-frequency magnetic noise, which we demonstrated using paramagnetic substitutional nitrogen (P1) centers. Finally, I describe open questions on the NV singlet states, saturation spectroscopy, and relaxation (and how to address them), and report on my ongoing work on using NVs for nuclear polarization and rotation sensing.
Optically addressable solid-state spin defects have emerged as powerful multimodal quantum sensors, with nitrogen-vacancy (NV) centers in bulk diamond providing benchmark quantum control and sensitivity under ambient conditions. Embedding such defects in nanodiamonds (NDs) extends these capabilities to mobile probes capable of accessing complex biological and nanoscale environments. Reduced dimensions, however, introduce constraints beyond volumetric spin impurities, notably enhanced lattice strain and surface-induced noise sources, which shorten NV spin relaxation times (T1 and T2) and destabilize the NV charge state, as well as resulting in pronounced particle-to-particle variability in NDs typically produced by top-down approaches. These effects complicate both sensing performance and the quantitative interpretation of multimodal signals in realistic environments. This article provides a structured perspective on the physical mechanisms by which material properties constrain NV behavior in NDs, together with mitigation strategies that shape the robust use of these mobile quantum sensors for biosensing and nanoscale science.
In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.