Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2509.22525 · Physical Review Research

High-stability optical clock based on a continuously ground-state cooled Al + ion without compromising its accuracy

Fabian Dawel, Lennart Pelzer, Kai Dietze, Johannes Krämer, Marek B. Hild, S. A. King, Nicolas Spethmann, J. Klose, Kurt A. Stahl, Sören Dörscher, Erik Benkler, Christian Lisdat, S. G. Porsev, Marianna S. Safronova, Piet O. Schmidt

Published Apr 27, 2026• 3 citations
arXivHTMLPDF

Abstract

Single-ion optical clocks have shown systematic frequency uncertainties below 10 − 18 , but typically require more than one week of averaging to achieve a corresponding statistical uncertainty. This time can be reduced with longer probe times, but comes at the cost of a higher time-dilation shift due to motional heating of the ions in the trap. We show that sympathetic ground-state cooling using electromagnetically induced transparency of an Al + clock ion via a cotrapped Ca + ion during clock interrogation suppresses the heating of the ions. Al + can be kept close to the motional ground state, independent from the chosen interrogation time, at a relative time-dilation shift of ( − 1.69 ± 0.20 ) × 10 − 18 . The Ca + cooling light introduces an additional light shift on the Al + clock transition of ( − 9.3 ± 1.1 ) × 10 − 18 . We project that the uncertainty of this light shift can be further reduced by nearly an order of magnitude. This sympathetic cooling enables seconds of interrogation time with 10 − 19 motional and cooling laser-induced uncertainties for Al + and can be employed in other ion clocks as well.

DOI
10.1103/48zr-2t1p

Related papers

Sympathetic electromagnetically induced transparency ground state cooling of a 40Ca+–27Al+ pair in an 27Al+ clock

Chenglong Sun, Kaifeng Cui, Sijia Chao +5 more

We report on electromagnetically induced transparency cooling of 40Ca+ to sympathetically cool the three-dimensional secular modes of motion in a 40Ca+–27Al+ two-ion pair near the ground state. We observe simultaneous ground state cooling across all radial modes and axial modes of a 40Ca+–27Al+ ion pair, occupying a broader cooling range in frequency space over 3 MHz. The cooling time is observed to be less than 1 ms. The mean phonon number and heating rates of all motional modes are measured. This study is not only an important step for reducing the secular motion time-dilation shift uncertainty and uptime ratio of 27Al+ optical clock, but also essential for high-fidelity quantum simulations and quantum information processors using trapped ions.

Chinese Physics B•Nov 17, 2022•2 citations

Al + 27 Quantum-Logic Clock with a Systematic Uncertainty below 10 − 18

Samuel M. Brewer, Jwo-Sy Chen, Aaron M. Hankin +5 more

We describe an optical atomic clock based on quantum-logic spectroscopy of the ^{1}S_{0}↔^{3}P_{0} transition in ^{27}Al^{+} with a systematic uncertainty of 9.4×10^{-19} and a frequency stability of 1.2×10^{-15}/sqrt[τ]. A ^{25}Mg^{+} ion is simultaneously trapped with the ^{27}Al^{+} ion and used for sympathetic cooling and state readout. Improvements in a new trap have led to reduced secular motion heating, compared to previous ^{27}Al^{+} clocks, enabling clock operation with ion secular motion near the three-dimensional ground state. Operating the clock with a lower trap drive frequency has reduced excess micromotion compared to previous ^{27}Al^{+} clocks. Both of these improvements have led to a reduced time-dilation shift uncertainty. Other systematic uncertainties including those due to blackbody radiation and the second-order Zeeman effect have also been reduced.

arXiv:1902.07694•Physical Review Letters•Jul 15, 2019•736 citations

Towards a transportable aluminium ion quantum logic optical clock

S. Hannig, L. Pelzer, N. Scharnhorst +7 more

With the advent of optical clocks featuring fractional frequency uncertainties on the order of 10−17 and below, new applications such as chronometric leveling with few-centimeter height resolution emerge. We are developing a transportable optical clock based on a single trapped aluminum ion, which is interrogated via quantum logic spectroscopy. We employ singly charged calcium as the logic ion for sympathetic cooling, state preparation, and readout. Here, we present a simple and compact physics and laser package for manipulation of 40Ca+. Important features are a segmented multilayer trap with separate loading and probing zones, a compact titanium vacuum chamber, a near-diffraction-limited imaging system with high numerical aperture based on a single biaspheric lens, and an all-in-fiber 40Ca+ repump laser system. We present preliminary estimates of the trap-induced frequency shifts on 27Al+, derived from measurements with a single calcium ion. The micromotion-induced second-order Doppler shift for 27Al+ has been determined to be δνEMMν=−0.4−0.3+0.4×10−18 and the black-body radiation shift is δνBBR/ν = (−4.0 ± 0.4) × 10−18. Moreover, heating rates of 30 (7) quanta per second at trap frequencies of ωrad,Ca+ ≈ 2π × 2.5 MHz (ωax,Ca+ ≈ 2π × 1.5 MHz) in radial (axial) direction have been measured, enabling interrogation times of a few hundreds of milliseconds.

arXiv:1901.02250•Review of Scientific Instruments•May 1, 2019•70 citations

High-Stability Single-Ion Clock with 5.5 × 10 − 19 Systematic Uncertainty

Mason C. Marshall, Daniel A. Rodriguez Castillo, Willa J. Arthur-Dworschack +10 more

We report a single-ion optical atomic clock with a fractional frequency uncertainty of 5.5×10^{-19} and fractional frequency stability of 3.5×10^{-16}/sqrt[τ/s], based on quantum logic spectroscopy of a single ^{27}Al^{+} ion. A cotrapped ^{25}Mg^{+} ion provides sympathetic cooling and quantum logic readout of the ^{27}Al^{+}^{1}S_{0}↔^{3}P_{0} clock transition. A Rabi probe duration of 1 s, enabled by laser stability transfer from a remote cryogenic silicon cavity across a 3.6 km fiber link, results in a threefold reduction in instability compared to previous ^{27}Al^{+} clocks. Systematic uncertainties are lower due to an improved ion trap electrical design, which reduces excess micromotion, and a new vacuum system, which reduces collisional shifts. We also perform a direction-sensitive measurement of the ac magnetic field due to the rf ion trap, eliminating systematic uncertainty due to field orientation.

arXiv:2504.13071•Physical Review Letters•Jul 14, 2025•91 citations

Sympathetic Ground State Cooling and Time-Dilation Shifts in an Al 27 + Optical Clock

Jwo-Sy Chen, Samuel M. Brewer, C. W. Chou +3 more

We report on Raman sideband cooling of ^{25}Mg^{+} to sympathetically cool the secular modes of motion in a ^{25}Mg^{+}-^{27}Al^{+} two-ion pair to near the three-dimensional (3D) ground state. The evolution of the Fock-state distribution during the cooling process is studied using a rate-equation simulation, and various heating sources that limit the efficiency of 3D sideband cooling in our system are discussed. We characterize the residual energy and heating rates of all of the secular modes of motion and estimate a secular motion time-dilation shift of -(1.9±0.1)×10^{-18} for an ^{27}Al^{+} clock at a typical clock probe duration of 150 ms. This is a 50-fold reduction in the secular motion time-dilation shift uncertainty in comparison with previous ^{27}Al^{+} clocks.

arXiv:1608.05047•Physical Review Letters•Jan 30, 2017•97 citations

Liquid-Nitrogen-Cooled Ca + Optical Clock with Systematic Uncertainty of 3×10−18

Yao Huang, Baolin Zhang, Mengyan Zeng +7 more

We present a liquid-nitrogen-cooled $\mathrm{Ca}$${}^{+}$ optical clock with an overall systematic uncertainty of $3.0\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$. In contrast to the room-temperature $\mathrm{Ca}$${}^{+}$ optical clock that we have reported previously, the cryogenic black-body radiation (BBR) shield in vacuum is cooled to $82\ifmmode\pm\else\textpm\fi{}5$ K using liquid nitrogen. We also implement an ion trap with a reduced heating rate and improved laser cooling. This allows the ion temperature to fall to the Doppler-cooling limit during the clock operation and the systematic uncertainty associated with the secular (thermal) motion of the ion is reduced to $<1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$. The uncertainty arising from the probe laser light shift and the servo error is also reduced to $<1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$ and $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$ with the hyper-Ramsey method and the higher-order servo algorithm, respectively. By comparing the output frequency of the cryogenic clock to that of a room-temperature clock, the differential BBR shift between the two is determined with a fractional statistical uncertainty of $7\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$. The differential BBR shift is used to calculate the static differential polarizability and the result is found to be in excellent agreement with our previous measurement using a different method. This work suggests that the BBR shift of optical clocks can be suppressed well in a liquid-nitrogen environment. Systems similar to what is presented here can also be used to suppress the BBR shift significantly in other types of optical clocks, such as $\mathrm{Yb}$${}^{+}$, $\mathrm{Sr}$${}^{+}$, $\mathrm{Yb}$, Sr, etc.

arXiv:2103.08913•Physical Review Applied•Mar 15, 2022•91 citations
Single-ion optical clocks have shown systematic frequency uncertainties below 10 − 18 , but typically require more than one week of averaging to achieve a corresponding statistical uncertainty. This time can be reduced with longer probe times, but comes at the cost of a higher time-dilation shift due to motional heating of the ions in the trap. We show that sympathetic ground-state cooling using electromagnetically induced transparency of an Al + clock ion via a cotrapped Ca + ion during clock interrogation suppresses the heating of the ions. Al + can be kept close to the motional ground state, independent from the chosen interrogation time, at a relative time-dilation shift of ( − 1.69 ± 0.20 ) × 10 − 18 . The Ca + cooling light introduces an additional light shift on the Al + clock transition of ( − 9.3 ± 1.1 ) × 10 − 18 . We project that the uncertainty of this light shift can be further reduced by nearly an order of magnitude. This sympathetic cooling enables seconds of interrogation time with 10 − 19 motional and cooling laser-induced uncertainties for Al + and can be employed in other ion clocks as well.
We report on electromagnetically induced transparency cooling of 40Ca+ to sympathetically cool the three-dimensional secular modes of motion in a 40Ca+–27Al+ two-ion pair near the ground state. We observe simultaneous ground state cooling across all radial modes and axial modes of a 40Ca+–27Al+ ion pair, occupying a broader cooling range in frequency space over 3 MHz. The cooling time is observed to be less than 1 ms. The mean phonon number and heating rates of all motional modes are measured. This study is not only an important step for reducing the secular motion time-dilation shift uncertainty and uptime ratio of 27Al+ optical clock, but also essential for high-fidelity quantum simulations and quantum information processors using trapped ions.
We describe an optical atomic clock based on quantum-logic spectroscopy of the ^{1}S_{0}↔^{3}P_{0} transition in ^{27}Al^{+} with a systematic uncertainty of 9.4×10^{-19} and a frequency stability of 1.2×10^{-15}/sqrt[τ]. A ^{25}Mg^{+} ion is simultaneously trapped with the ^{27}Al^{+} ion and used for sympathetic cooling and state readout. Improvements in a new trap have led to reduced secular motion heating, compared to previous ^{27}Al^{+} clocks, enabling clock operation with ion secular motion near the three-dimensional ground state. Operating the clock with a lower trap drive frequency has reduced excess micromotion compared to previous ^{27}Al^{+} clocks. Both of these improvements have led to a reduced time-dilation shift uncertainty. Other systematic uncertainties including those due to blackbody radiation and the second-order Zeeman effect have also been reduced.
With the advent of optical clocks featuring fractional frequency uncertainties on the order of 10−17 and below, new applications such as chronometric leveling with few-centimeter height resolution emerge. We are developing a transportable optical clock based on a single trapped aluminum ion, which is interrogated via quantum logic spectroscopy. We employ singly charged calcium as the logic ion for sympathetic cooling, state preparation, and readout. Here, we present a simple and compact physics and laser package for manipulation of 40Ca+. Important features are a segmented multilayer trap with separate loading and probing zones, a compact titanium vacuum chamber, a near-diffraction-limited imaging system with high numerical aperture based on a single biaspheric lens, and an all-in-fiber 40Ca+ repump laser system. We present preliminary estimates of the trap-induced frequency shifts on 27Al+, derived from measurements with a single calcium ion. The micromotion-induced second-order Doppler shift for 27Al+ has been determined to be δνEMMν=−0.4−0.3+0.4×10−18 and the black-body radiation shift is δνBBR/ν = (−4.0 ± 0.4) × 10−18. Moreover, heating rates of 30 (7) quanta per second at trap frequencies of ωrad,Ca+ ≈ 2π × 2.5 MHz (ωax,Ca+ ≈ 2π × 1.5 MHz) in radial (axial) direction have been measured, enabling interrogation times of a few hundreds of milliseconds.
We report a single-ion optical atomic clock with a fractional frequency uncertainty of 5.5×10^{-19} and fractional frequency stability of 3.5×10^{-16}/sqrt[τ/s], based on quantum logic spectroscopy of a single ^{27}Al^{+} ion. A cotrapped ^{25}Mg^{+} ion provides sympathetic cooling and quantum logic readout of the ^{27}Al^{+}^{1}S_{0}↔^{3}P_{0} clock transition. A Rabi probe duration of 1 s, enabled by laser stability transfer from a remote cryogenic silicon cavity across a 3.6 km fiber link, results in a threefold reduction in instability compared to previous ^{27}Al^{+} clocks. Systematic uncertainties are lower due to an improved ion trap electrical design, which reduces excess micromotion, and a new vacuum system, which reduces collisional shifts. We also perform a direction-sensitive measurement of the ac magnetic field due to the rf ion trap, eliminating systematic uncertainty due to field orientation.
We report on Raman sideband cooling of ^{25}Mg^{+} to sympathetically cool the secular modes of motion in a ^{25}Mg^{+}-^{27}Al^{+} two-ion pair to near the three-dimensional (3D) ground state. The evolution of the Fock-state distribution during the cooling process is studied using a rate-equation simulation, and various heating sources that limit the efficiency of 3D sideband cooling in our system are discussed. We characterize the residual energy and heating rates of all of the secular modes of motion and estimate a secular motion time-dilation shift of -(1.9±0.1)×10^{-18} for an ^{27}Al^{+} clock at a typical clock probe duration of 150 ms. This is a 50-fold reduction in the secular motion time-dilation shift uncertainty in comparison with previous ^{27}Al^{+} clocks.
We present a liquid-nitrogen-cooled Ca\mathrm{Ca}Ca+{}^{+}+ optical clock with an overall systematic uncertainty of $3.0\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$. In contrast to the room-temperature Ca\mathrm{Ca}Ca+{}^{+}+ optical clock that we have reported previously, the cryogenic black-body radiation (BBR) shield in vacuum is cooled to $82\ifmmode\pm\else\textpm\fi{}5$ K using liquid nitrogen. We also implement an ion trap with a reduced heating rate and improved laser cooling. This allows the ion temperature to fall to the Doppler-cooling limit during the clock operation and the systematic uncertainty associated with the secular (thermal) motion of the ion is reduced to $<1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$. The uncertainty arising from the probe laser light shift and the servo error is also reduced to $<1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$ and $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$ with the hyper-Ramsey method and the higher-order servo algorithm, respectively. By comparing the output frequency of the cryogenic clock to that of a room-temperature clock, the differential BBR shift between the two is determined with a fractional statistical uncertainty of $7\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$. The differential BBR shift is used to calculate the static differential polarizability and the result is found to be in excellent agreement with our previous measurement using a different method. This work suggests that the BBR shift of optical clocks can be suppressed well in a liquid-nitrogen environment. Systems similar to what is presented here can also be used to suppress the BBR shift significantly in other types of optical clocks, such as Yb\mathrm{Yb}Yb+{}^{+}+, Sr\mathrm{Sr}Sr+{}^{+}+, Yb\mathrm{Yb}Yb, Sr, etc.