Mason C. Marshall, Daniel A. Rodriguez Castillo, Willa J. Arthur-Dworschack, Alexander Aeppli, Kyungtae Kim, Dahyeon Lee, William Warfield, Joost Hinrichs, Nicholas V. Nardelli, Tara M. Fortier, Jun Ye, David R. Leibrandt, David B. Hume
We report a single-ion optical atomic clock with a fractional frequency uncertainty of 5.5×10^{-19} and fractional frequency stability of 3.5×10^{-16}/sqrt[τ/s], based on quantum logic spectroscopy of a single ^{27}Al^{+} ion. A cotrapped ^{25}Mg^{+} ion provides sympathetic cooling and quantum logic readout of the ^{27}Al^{+}^{1}S_{0}↔^{3}P_{0} clock transition. A Rabi probe duration of 1 s, enabled by laser stability transfer from a remote cryogenic silicon cavity across a 3.6 km fiber link, results in a threefold reduction in instability compared to previous ^{27}Al^{+} clocks. Systematic uncertainties are lower due to an improved ion trap electrical design, which reduces excess micromotion, and a new vacuum system, which reduces collisional shifts. We also perform a direction-sensitive measurement of the ac magnetic field due to the rf ion trap, eliminating systematic uncertainty due to field orientation.
We report a single-ion optical atomic clock with a fractional frequency uncertainty of 5.5×10^{-19} and fractional frequency stability of 3.5×10^{-16}/sqrt[τ/s], based on quantum logic spectroscopy of a single ^{27}Al^{+} ion. A cotrapped ^{25}Mg^{+} ion provides sympathetic cooling and quantum logic readout of the ^{27}Al^{+}^{1}S_{0}↔^{3}P_{0} clock transition. A Rabi probe duration of 1 s, enabled by laser stability transfer from a remote cryogenic silicon cavity across a 3.6 km fiber link, results in a threefold reduction in instability compared to previous ^{27}Al^{+} clocks. Systematic uncertainties are lower due to an improved ion trap electrical design, which reduces excess micromotion, and a new vacuum system, which reduces collisional shifts. We also perform a direction-sensitive measurement of the ac magnetic field due to the rf ion trap, eliminating systematic uncertainty due to field orientation.
We describe an optical atomic clock based on quantum-logic spectroscopy of the ^{1}S_{0}↔^{3}P_{0} transition in ^{27}Al^{+} with a systematic uncertainty of 9.4×10^{-19} and a frequency stability of 1.2×10^{-15}/sqrt[τ]. A ^{25}Mg^{+} ion is simultaneously trapped with the ^{27}Al^{+} ion and used for sympathetic cooling and state readout. Improvements in a new trap have led to reduced secular motion heating, compared to previous ^{27}Al^{+} clocks, enabling clock operation with ion secular motion near the three-dimensional ground state. Operating the clock with a lower trap drive frequency has reduced excess micromotion compared to previous ^{27}Al^{+} clocks. Both of these improvements have led to a reduced time-dilation shift uncertainty. Other systematic uncertainties including those due to blackbody radiation and the second-order Zeeman effect have also been reduced.
We have constructed an optical clock with a fractional frequency inaccuracy of 8.6x10{-18}, based on quantum logic spectroscopy of an Al+ ion. A simultaneously trapped Mg+ ion serves to sympathetically laser cool the Al+ ion and detect its quantum state. The frequency of the {1}S{0}<-->{3}P{0} clock transition is compared to that of a previously constructed Al+ optical clock with a statistical measurement uncertainty of 7.0x10{-18}. The two clocks exhibit a relative stability of 2.8x10{-15}tau{-1/2}, and a fractional frequency difference of -1.8x10{-17}, consistent with the accuracy limit of the older clock.
With the advent of optical clocks featuring fractional frequency uncertainties on the order of 10−17 and below, new applications such as chronometric leveling with few-centimeter height resolution emerge. We are developing a transportable optical clock based on a single trapped aluminum ion, which is interrogated via quantum logic spectroscopy. We employ singly charged calcium as the logic ion for sympathetic cooling, state preparation, and readout. Here, we present a simple and compact physics and laser package for manipulation of 40Ca+. Important features are a segmented multilayer trap with separate loading and probing zones, a compact titanium vacuum chamber, a near-diffraction-limited imaging system with high numerical aperture based on a single biaspheric lens, and an all-in-fiber 40Ca+ repump laser system. We present preliminary estimates of the trap-induced frequency shifts on 27Al+, derived from measurements with a single calcium ion. The micromotion-induced second-order Doppler shift for 27Al+ has been determined to be δνEMMν=−0.4−0.3+0.4×10−18 and the black-body radiation shift is δνBBR/ν = (−4.0 ± 0.4) × 10−18. Moreover, heating rates of 30 (7) quanta per second at trap frequencies of ωrad,Ca+ ≈ 2π × 2.5 MHz (ωax,Ca+ ≈ 2π × 1.5 MHz) in radial (axial) direction have been measured, enabling interrogation times of a few hundreds of milliseconds.
Optical clocks have been demonstrated to be good choices to redefine the SI ``second.'' With this goal, we have constructed a quantum-logic-based 27Al+ ion optical clock with a fractional frequency uncertainty of $1.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$. A 25Mg+ ion is used as the logic ion for sympathetic cooling, state readout, and frequency-shift measurement of the 27Al+ ion. The stability of the optical clock is $2.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}/\sqrt{\ensuremath{\tau}}$, measured with a self-comparison method.
Atomic clock frequency ratios with fractional uncertainty ≤3.2×10−18
We report high-precision frequency ratio measurements between optical atomic clocks based on 27Al+, 171Yb, and 87Sr. With total fractional uncertainties at or below 3.2×10−18, these measurements meet an important milestone criterion for redefinition of the second in the International System of Units. Discrepancies in 87Sr ratios at approximately 1×10−16 and the Al+/Yb ratio at 1.6×10−17 in fractional units compared to our previous measurements underscore the importance of repeated, high-precision comparisons by different laboratories. A key innovation in this work is the use of a common ultrastable reference delivered to all clocks via a 3.6 km phase-stabilized fiber link between two institutions. Derived from a cryogenic single-crystal silicon cavity, this reference improves comparison stability by a factor of 2 to 3 over previous systems, with an optical lattice clock ratio achieving a fractional instability of 1.3×10−16 at 1 second. By enabling faster comparisons, this stability will improve sensitivity to non-white noise processes and other underlying limits of state-of-the-art optical frequency standards.
At the time of writing, state of the art stationary optical clocks reach 10 −18 sys- tematic fractional frequency uncertainty, which allows for the search of new physics beyond the standard model and lays the foundation for new applications such as chronometric leveling, where height differences relative to the geoid are derived from frequency comparisons among optical clocks. Transportable optical clocks allow for chronometric leveling between distant lo- cations which are not connected by a direct line of sight but via length stabilized optical fiber. Moreover, they facilitate frequency comparisons between distant sta- tionary clocks via subsequent side-by-side comparisons without the necessity of a long-range fiber connection. A transportable optical clock employing a single 40Ca+ ion has been reported and a neutral atom 87Sr lattice clock has been employed in a chronometric leveling campaign. However, these clocks report an estimated systematic fractional frequency uncertainty in the high 10^−17 range, which limits their height resolution to a level of approximately 1 m. 27Al+ has one of the smallest blackbody radiation shifts, small linear and quadratic Zeeman shifts and a negligible quadrupole shift, which makes it a candidate for a highly accurate optical clock. This thesis reports on the development, set-up, and characterization of a transportable 27Al+ clock setup with 40Ca+ as logic ion. The setup is simple, modular, compact, and mechanically stable. Ions of both species are generated via pulsed laser ablation and subsequent photoionization. They are confined in a multi-layer trap with segmented loading and experiment zones. Using a single 40Ca+ ion as probe, heating rates of below 10 quanta per second have been measured in all three directions for trap frequencies around 2π × 2 MHz, and pulsed sideband cooling to mean motional quantum numbers below 0.1 quanta was demonstrated. Imaging close to the diffraction limit with a signal to noise ratio of 800 for 300 ms exposure time on a sCMOS camera was achieved using a single NA = 0.51 biaspheric lens. Simultaneously, a state discrimination error below 10^−5 in 100 µs was obtained using a PMT. From the excess micromotion second order Doppler shift, secular motion second order Doppler shift, BBR shift, and background gas collision shift, a partial systematic fractional frequency uncertainty of 1.7 × 10^−18 was inferred, which is equivalent to a height resolution of ca. 2 cm. Moreover, a highly stable mechanical monolithic enhancement cavity for SHG has been developed and demonstrated to withstand accelerations of 3 g rms for 30 min. It has been operated for an uninterrupted period of 130 h without decay in output power in the mid-UV due to O2 -purging, its sealed design, and material selection, which solves the often observed crystal degradation in UV applications. The cavity has been employed in the 27Al+ logic laser system. In conclusion, it has been shown that an 27Al+ ion quantum logic optical clock operated in the present transportable setup could reach an estimated systematic fractional frequency uncertainty of 1.7 × 10^−18 , provided that all other shifts, such as the second order Zeeman shift, are negligible. This paves the way towards chronometric leveling with an unprecedented height resolution of about 2 cm.