arXiv:1902.07694 · Physical Review Letters

Al + 27 Quantum-Logic Clock with a Systematic Uncertainty below 10 − 18

Samuel M. Brewer, Jwo-Sy Chen, Aaron M. Hankin, Ethan Clements, C. W. Chou, David J. Wineland, David B. Hume, David R. Leibrandt

Published Jul 15, 2019• 736 citations
arXivHTMLPDF

Abstract

We describe an optical atomic clock based on quantum-logic spectroscopy of the ^{1}S_{0}↔^{3}P_{0} transition in ^{27}Al^{+} with a systematic uncertainty of 9.4×10^{-19} and a frequency stability of 1.2×10^{-15}/sqrt[τ]. A ^{25}Mg^{+} ion is simultaneously trapped with the ^{27}Al^{+} ion and used for sympathetic cooling and state readout. Improvements in a new trap have led to reduced secular motion heating, compared to previous ^{27}Al^{+} clocks, enabling clock operation with ion secular motion near the three-dimensional ground state. Operating the clock with a lower trap drive frequency has reduced excess micromotion compared to previous ^{27}Al^{+} clocks. Both of these improvements have led to a reduced time-dilation shift uncertainty. Other systematic uncertainties including those due to blackbody radiation and the second-order Zeeman effect have also been reduced.

DOI
10.1103/physrevlett.123.033201

Related papers

High-Stability Single-Ion Clock with 5.5 × 10 − 19 Systematic Uncertainty

Mason C. Marshall, Daniel A. Rodriguez Castillo, Willa J. Arthur-Dworschack +10 more

We report a single-ion optical atomic clock with a fractional frequency uncertainty of 5.5×10^{-19} and fractional frequency stability of 3.5×10^{-16}/sqrt[τ/s], based on quantum logic spectroscopy of a single ^{27}Al^{+} ion. A cotrapped ^{25}Mg^{+} ion provides sympathetic cooling and quantum logic readout of the ^{27}Al^{+}^{1}S_{0}↔^{3}P_{0} clock transition. A Rabi probe duration of 1 s, enabled by laser stability transfer from a remote cryogenic silicon cavity across a 3.6 km fiber link, results in a threefold reduction in instability compared to previous ^{27}Al^{+} clocks. Systematic uncertainties are lower due to an improved ion trap electrical design, which reduces excess micromotion, and a new vacuum system, which reduces collisional shifts. We also perform a direction-sensitive measurement of the ac magnetic field due to the rf ion trap, eliminating systematic uncertainty due to field orientation.

arXiv:2504.13071•Physical Review Letters•Jul 14, 2025•91 citations

Evaluation of the performance of a ${}^{40}\textrm{Ca}^+ - {}^{27}\textrm{Al}^+$ optical clock

Kaifeng Cui, Sijia Chao, Chenglong Sun +6 more

We report the evaluation of the systematic shifts and the total uncertainty of an ${}^{27}\textrm{Al}^+$ optical clock sympathetically cooled by a ${}^{40}\textrm{Ca}^+$ ion. Due to its relatively low Doppler cooling limit and the suitability of its mass ratio to the ${}^{27}\textrm{Al}^+$ ion, the time dilation shift of the secular motion of our ${}^{40}\textrm{Ca}^+ - {}^{27}\textrm{Al}^+$ clock is smaller than the shift of a ${}^{25}\textrm{Mg}^+ - {}^{27}\textrm{Al}^+$ clock. The total systematic uncertainty of our ${}^{40}\textrm{Ca}^+ - {}^{27}\textrm{Al}^+$ quantum logic clock has been estimated to be $7.6 \times 10^{-18}$, which was mainly limited by the uncertainty of the quadratic Zeeman shift.

•Dec 10, 2020•0 citations

Frequency Comparison of Two High-Accuracy Al + Optical Clocks

C. W. Chou, David B. Hume, Jeroen C. J. Koelemeij +2 more

We have constructed an optical clock with a fractional frequency inaccuracy of 8.6x10{-18}, based on quantum logic spectroscopy of an Al+ ion. A simultaneously trapped Mg+ ion serves to sympathetically laser cool the Al+ ion and detect its quantum state. The frequency of the {1}S{0}<-->{3}P{0} clock transition is compared to that of a previously constructed Al+ optical clock with a statistical measurement uncertainty of 7.0x10{-18}. The two clocks exhibit a relative stability of 2.8x10{-15}tau{-1/2}, and a fractional frequency difference of -1.8x10{-17}, consistent with the accuracy limit of the older clock.

arXiv:0911.4527•Physical Review Letters•Feb 17, 2010•917 citations

Systematic Uncertainty Below 10^-18 in the Aluminium Quantum-Logic Clock: Motion, Zeeman and Blackbody Budgets

William Alexander Aldred

Systematic uncertainty below 10^-18 in the aluminium quantum-logic clock is examined for the NIST aluminium-27 quantum-logic clock, with a published systematic uncertainty of 9.4 parts inside 10^19, the smallest total reported for any clock in its era. Principal computed quantities: total uncertainty e19 = 9.462; published total e19 = 9.4; ratio computed to published = 1.007; motion pair e19 = 6.574; motion share of variance pct = 48.28; height equivalent mm = 8.671. The governing idea, for NIST aluminium-27 quantum-logic clock, runs as follows. A single trapped ion has no density shift and almost no blackbody shift, so its budget is dominated instead by motion: the time-dilation effects of secular motion and excess micromotion, and by the second-order zeeman shift of the trapping field. Setting total uncertainty e19 at 9.462 beside published total e19 at 9.4 shows, for NIST aluminium-27 quantum-logic clock, the scale, for NIST aluminium-27 quantum-logic clock, before interpretation. Both numbers, for NIST aluminium-27 quantum-logic clock, come from the systematic uncertainty below 10^-18 in the aluminium quantum-logic clock relations. The later discussion, for NIST aluminium-27 quantum-logic clock, sets total uncertainty e19 at 9.462 against published values for NIST aluminium-27 quantum-logic clock and names, for NIST aluminium-27 quantum-logic clock, the input moving total uncertainty e19 at 9.462 furthest.

•Nov 15, 2026•0 citations

Ticking near the Zero-Point Energy: Towards 1 x 10^-18 Accuracy in Al^+ Optical Clocks

Jwo-Sy Chen

The advancement of optical atomic clocks in the past two decades has motivated many potential applications in navigation, communication, and science. Accurate optical clocks that outperform the current cesium time standard also trigger a discussion about a possible redefinition of the SI second. The 27Al+ quantum logic clocks developed at the National Institute of Standards and Technology (NIST) were the first to achieve the clock fractional frequency uncertainty below 10-17 in 2010. To date, a few research groups around the world have demonstrated optical clocks based on various atomic transitions with fractional frequency uncertainty in the 10-18 range. The accuracy of the previous 27Al+ clocks was limited by the second order Doppler (time dilation) shift and the blackbody shift. Since 2010, the third 27Al+ optical clock is being developed at NIST to achieve a higher accuracy. The frequency uncertainties dominant in the previous clocks are controlled and reduced in the current optical clock. The new design of the ion trap system has reduced significantly both the blackbody radiation shift uncertainty and the time dilation shift uncertainty due to micromotion, while the time dilation shift uncertainty due to the secular motion has been reduced by more than an order of magnitude by operating the optical clock near the three dimensional zero-point energy. Despite those previously dominant uncertainties, several other systematic effects are being evaluated and some other efforts are being made to achieve a total uncertainty towards 1.0 x 10-18. In this thesis, I will document the detail of the construction and evaluation of the current 27Al+ optical clock developed at NIST.

•Jan 1, 2017•4 citations

Towards a transportable aluminium ion quantum logic optical clock

S. Hannig, L. Pelzer, N. Scharnhorst +7 more

With the advent of optical clocks featuring fractional frequency uncertainties on the order of 10−17 and below, new applications such as chronometric leveling with few-centimeter height resolution emerge. We are developing a transportable optical clock based on a single trapped aluminum ion, which is interrogated via quantum logic spectroscopy. We employ singly charged calcium as the logic ion for sympathetic cooling, state preparation, and readout. Here, we present a simple and compact physics and laser package for manipulation of 40Ca+. Important features are a segmented multilayer trap with separate loading and probing zones, a compact titanium vacuum chamber, a near-diffraction-limited imaging system with high numerical aperture based on a single biaspheric lens, and an all-in-fiber 40Ca+ repump laser system. We present preliminary estimates of the trap-induced frequency shifts on 27Al+, derived from measurements with a single calcium ion. The micromotion-induced second-order Doppler shift for 27Al+ has been determined to be δνEMMν=−0.4−0.3+0.4×10−18 and the black-body radiation shift is δνBBR/ν = (−4.0 ± 0.4) × 10−18. Moreover, heating rates of 30 (7) quanta per second at trap frequencies of ωrad,Ca+ ≈ 2π × 2.5 MHz (ωax,Ca+ ≈ 2π × 1.5 MHz) in radial (axial) direction have been measured, enabling interrogation times of a few hundreds of milliseconds.

arXiv:1901.02250•Review of Scientific Instruments•May 1, 2019•70 citations
We describe an optical atomic clock based on quantum-logic spectroscopy of the ^{1}S_{0}↔^{3}P_{0} transition in ^{27}Al^{+} with a systematic uncertainty of 9.4×10^{-19} and a frequency stability of 1.2×10^{-15}/sqrt[τ]. A ^{25}Mg^{+} ion is simultaneously trapped with the ^{27}Al^{+} ion and used for sympathetic cooling and state readout. Improvements in a new trap have led to reduced secular motion heating, compared to previous ^{27}Al^{+} clocks, enabling clock operation with ion secular motion near the three-dimensional ground state. Operating the clock with a lower trap drive frequency has reduced excess micromotion compared to previous ^{27}Al^{+} clocks. Both of these improvements have led to a reduced time-dilation shift uncertainty. Other systematic uncertainties including those due to blackbody radiation and the second-order Zeeman effect have also been reduced.
We report a single-ion optical atomic clock with a fractional frequency uncertainty of 5.5×10^{-19} and fractional frequency stability of 3.5×10^{-16}/sqrt[τ/s], based on quantum logic spectroscopy of a single ^{27}Al^{+} ion. A cotrapped ^{25}Mg^{+} ion provides sympathetic cooling and quantum logic readout of the ^{27}Al^{+}^{1}S_{0}↔^{3}P_{0} clock transition. A Rabi probe duration of 1 s, enabled by laser stability transfer from a remote cryogenic silicon cavity across a 3.6 km fiber link, results in a threefold reduction in instability compared to previous ^{27}Al^{+} clocks. Systematic uncertainties are lower due to an improved ion trap electrical design, which reduces excess micromotion, and a new vacuum system, which reduces collisional shifts. We also perform a direction-sensitive measurement of the ac magnetic field due to the rf ion trap, eliminating systematic uncertainty due to field orientation.
Evaluation of the performance of a 40Ca+−27Al+{}^{40}\textrm{Ca}^+ - {}^{27}\textrm{Al}^+40Ca+−27Al+ optical clock
We report the evaluation of the systematic shifts and the total uncertainty of an 27Al+{}^{27}\textrm{Al}^+27Al+ optical clock sympathetically cooled by a 40Ca+{}^{40}\textrm{Ca}^+40Ca+ ion. Due to its relatively low Doppler cooling limit and the suitability of its mass ratio to the 27Al+{}^{27}\textrm{Al}^+27Al+ ion, the time dilation shift of the secular motion of our 40Ca+−27Al+{}^{40}\textrm{Ca}^+ - {}^{27}\textrm{Al}^+40Ca+−27Al+ clock is smaller than the shift of a 25Mg+−27Al+{}^{25}\textrm{Mg}^+ - {}^{27}\textrm{Al}^+25Mg+−27Al+ clock. The total systematic uncertainty of our 40Ca+−27Al+{}^{40}\textrm{Ca}^+ - {}^{27}\textrm{Al}^+40Ca+−27Al+ quantum logic clock has been estimated to be 7.6×10−187.6 \times 10^{-18}7.6×10−18, which was mainly limited by the uncertainty of the quadratic Zeeman shift.
We have constructed an optical clock with a fractional frequency inaccuracy of 8.6x10{-18}, based on quantum logic spectroscopy of an Al+ ion. A simultaneously trapped Mg+ ion serves to sympathetically laser cool the Al+ ion and detect its quantum state. The frequency of the {1}S{0}<-->{3}P{0} clock transition is compared to that of a previously constructed Al+ optical clock with a statistical measurement uncertainty of 7.0x10{-18}. The two clocks exhibit a relative stability of 2.8x10{-15}tau{-1/2}, and a fractional frequency difference of -1.8x10{-17}, consistent with the accuracy limit of the older clock.
Systematic uncertainty below 10^-18 in the aluminium quantum-logic clock is examined for the NIST aluminium-27 quantum-logic clock, with a published systematic uncertainty of 9.4 parts inside 10^19, the smallest total reported for any clock in its era. Principal computed quantities: total uncertainty e19 = 9.462; published total e19 = 9.4; ratio computed to published = 1.007; motion pair e19 = 6.574; motion share of variance pct = 48.28; height equivalent mm = 8.671. The governing idea, for NIST aluminium-27 quantum-logic clock, runs as follows. A single trapped ion has no density shift and almost no blackbody shift, so its budget is dominated instead by motion: the time-dilation effects of secular motion and excess micromotion, and by the second-order zeeman shift of the trapping field. Setting total uncertainty e19 at 9.462 beside published total e19 at 9.4 shows, for NIST aluminium-27 quantum-logic clock, the scale, for NIST aluminium-27 quantum-logic clock, before interpretation. Both numbers, for NIST aluminium-27 quantum-logic clock, come from the systematic uncertainty below 10^-18 in the aluminium quantum-logic clock relations. The later discussion, for NIST aluminium-27 quantum-logic clock, sets total uncertainty e19 at 9.462 against published values for NIST aluminium-27 quantum-logic clock and names, for NIST aluminium-27 quantum-logic clock, the input moving total uncertainty e19 at 9.462 furthest.
The advancement of optical atomic clocks in the past two decades has motivated many potential applications in navigation, communication, and science. Accurate optical clocks that outperform the current cesium time standard also trigger a discussion about a possible redefinition of the SI second. The 27Al+ quantum logic clocks developed at the National Institute of Standards and Technology (NIST) were the first to achieve the clock fractional frequency uncertainty below 10-17 in 2010. To date, a few research groups around the world have demonstrated optical clocks based on various atomic transitions with fractional frequency uncertainty in the 10-18 range. The accuracy of the previous 27Al+ clocks was limited by the second order Doppler (time dilation) shift and the blackbody shift. Since 2010, the third 27Al+ optical clock is being developed at NIST to achieve a higher accuracy. The frequency uncertainties dominant in the previous clocks are controlled and reduced in the current optical clock. The new design of the ion trap system has reduced significantly both the blackbody radiation shift uncertainty and the time dilation shift uncertainty due to micromotion, while the time dilation shift uncertainty due to the secular motion has been reduced by more than an order of magnitude by operating the optical clock near the three dimensional zero-point energy. Despite those previously dominant uncertainties, several other systematic effects are being evaluated and some other efforts are being made to achieve a total uncertainty towards 1.0 x 10-18. In this thesis, I will document the detail of the construction and evaluation of the current 27Al+ optical clock developed at NIST.
With the advent of optical clocks featuring fractional frequency uncertainties on the order of 10−17 and below, new applications such as chronometric leveling with few-centimeter height resolution emerge. We are developing a transportable optical clock based on a single trapped aluminum ion, which is interrogated via quantum logic spectroscopy. We employ singly charged calcium as the logic ion for sympathetic cooling, state preparation, and readout. Here, we present a simple and compact physics and laser package for manipulation of 40Ca+. Important features are a segmented multilayer trap with separate loading and probing zones, a compact titanium vacuum chamber, a near-diffraction-limited imaging system with high numerical aperture based on a single biaspheric lens, and an all-in-fiber 40Ca+ repump laser system. We present preliminary estimates of the trap-induced frequency shifts on 27Al+, derived from measurements with a single calcium ion. The micromotion-induced second-order Doppler shift for 27Al+ has been determined to be δνEMMν=−0.4−0.3+0.4×10−18 and the black-body radiation shift is δνBBR/ν = (−4.0 ± 0.4) × 10−18. Moreover, heating rates of 30 (7) quanta per second at trap frequencies of ωrad,Ca+ ≈ 2π × 2.5 MHz (ωax,Ca+ ≈ 2π × 1.5 MHz) in radial (axial) direction have been measured, enabling interrogation times of a few hundreds of milliseconds.