Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2304.06296 · Physical Review Applied

Multitone Microwave Frequency Locking to a Noisy Cavity via Real-Time Feedback

Jean-Paul van Soest, C. A. Potts, Sarwan Peiter, Adrián Sanz Mora, Gary Alexander Steele

Published Sep 6, 2023• 0 citations
arXivHTMLPDF

Abstract

Microwave cavities are commonly used in many experiments, including optomechanics, magnetic field sensing, magnomechanics, and circuit quantum electrodynamics. Noise, such as variations in the magnetic field or mechanical vibrations, can cause fluctuations of the natural frequency of the cavity, creating challenges in operating them in experiments. To overcome these challenges, we demonstrate a dynamic feedback system implemented by the locking of a microwave drive to the noisy cavity. A homodyne-interferometer scheme monitors the cavity resonance fluctuations due to low-frequency noise, which is mitigated by frequency modulating the microwave generator. The feedback has a bandwidth of 400 Hz, with a reduction of cavity fluctuations by $85\mathrm{%}$ integrating up to a bandwidth of 2 kHz. Moreover, the cavity resonance frequency fluctuations are reduced by $73\mathrm{%}$. This scheme can be scaled to enable multitone experiments locked to the same feedback signal. As a demonstration, we apply the feedback to an optomechanical experiment and implement a cavity-locked multitone mechanical measurement. As low-frequency cavity frequency noise can be a limiting factor in many experiments, the multitone microwave locking technique presented here is expected to be relevant for a wide range of microwave-cavity experiments.

DOI
10.1103/physrevapplied.20.034007

Related papers

Suppressing Cavity Frequency Noise Using a Kerr Nonlinearity

J. P. van Soest, S. Meilof, G. L. Bhai +3 more

Resonance-frequency fluctuations can limit the sensitivity and stability of superconducting microwave cavities used for qubit readout, optomechanical displacement sensing, and magnetic flux detection. Here, we demonstrate the suppression of resonance-frequency fluctuations by locking a noisy nonlinear superconducting microwave cavity to a strong pump tone. The Kerr nonlinearity of this system, whereby the resonance frequency depends on the intracavity field amplitude, gives rise to an intrinsic feedback mechanism that enables passive stabilization without active external feedback. Using two-tone spectroscopy, we experimentally characterize the intrinsic nonlinear feedback mechanism and investigate its temporal stability through Allan deviation analysis. The frequency fluctuations of the locked cavity mode are reduced by nearly two orders of magnitude, reaching the $1/f$ noise floor, without continuous frequency tracking or active control. Kerr locking provides a general approach for self-stabilizing nonlinear microwave resonators by suppressing low-frequency cavity noise while preserving sensitivity to signals outside the locking bandwidth. This approach may benefit a broad range of systems, including SQUID-based resonators, optomechanical devices, and parametric amplifiers.

quant-pharXiv:2608.03440•Aug 5, 2026•0 citations

Low-Noise Amplification and Frequency Conversion with a Multiport Microwave Optomechanical Device

Caspar F. Ockeloen-Korppi, Erno Damskägg, J.-M. Pirkkalainen +3 more

High-gain amplifiers of electromagnetic signals operating near the quantum limit are crucial for quantum information systems and ultrasensitive quantum measurements.However, the existing techniques have a limited gain-bandwidth product and only operate with weak input signals.Here, we demonstrate a two-port optomechanical scheme for amplification and routing of microwave signals, a system that simultaneously performs high-gain amplification and frequency conversion in the quantum regime.Our amplifier, implemented in a two-cavity microwave optomechanical device, shows 41 dB of gain and has a high dynamic range, handling input signals up to 10 13 photons per second, 3 orders of magnitude more than corresponding Josephson parametric amplifiers.We show that although the active medium, the mechanical resonator, is at a high temperature far from the quantum limit, only 4.6 quanta of noise is added to the input signal.Our method can be readily applied to a wide variety of optomechanical systems, including hybrid optical-microwave systems, creating a universal hub for signals at the quantum level.

arXiv:1602.05779•Physical Review X•Oct 28, 2016•67 citations

Feedback Stabilization of the Resonant Frequency in a Tunable Microwave Cavity with Single-Photon Occupancy

S. Kanhirathingal, B. Thyagarajan, Benjamin L. Brock +5 more

We successfully demonstrate low-frequency noise suppression in the resonant-frequency fluctuations of a cavity-embedded Cooper-pair transistor (cCPT) driven at single-photon occupancy. In particular, we report a reduction in the resonant-frequency fluctuations caused by the internal charge noise over a bandwidth of approximately $1.4\phantom{\rule{0.2em}{0ex}}\text{kHz}$ when the cavity is driven at an average photon number $n=10$ and a bandwidth of 11 Hz for an average $n=1$. The gate-dependent tunability of the cCPT allows us to implement a feedback scheme derived from the Pound-Drever-Hall locking technique. This reduces fluctuations due to intrinsic charge noise, which otherwise interfere with the operation of the cCPT as a near quantum-limited electrometer. Our technique can be generalized to achieve frequency stabilization in tunable microwave resonators that play a vital role in today's quantum computing architectures, thereby moderating the limitations in detection caused by the intrinsic $1/f$ noise on such circuit devices. The work discusses the various aspects relating to the operation of a fully functional feedback loop down to the single-photon level.

arXiv:2202.04227•Physical Review Applied•Dec 13, 2022•3 citations

Optomechanical Microwave Amplification without Mechanical Amplification

Martijn A. Cohen, Daniel Bothner, Yaroslav M. Blanter +1 more

High-gain and low-noise signal amplification is a valuable tool in various cryogenic microwave experiments. A microwave optomechanical device, in which a vibrating capacitor modulates the frequency of a microwave cavity, is one technique that is able to amplify microwave signals with high gain and large dynamical range. Such optomechanical amplifiers typically rely on strong backaction of microwave photons on the mechanical mode achieved in the sideband-resolved limit of optomechanics. Here, we observe microwave amplification in an optomechanical cavity in the extremely unresolved sideband limit. A large gain is observed for any detuning of the single pump tone within the cavity linewidth, a clear indication that the amplification is not induced by dynamical backaction. By being able to amplify for any detuning of the pump signal, the amplification center frequency can be tuned over the entire range of the broad cavity linewidth. Additionally, by providing microwave amplification without mechanical amplification, we predict that by using this scheme it is possible to achieve near-quantum-limited microwave amplification despite a large thermal occupation of the mechanical mode.

arXiv:1812.05459•Physical Review Applied•Jan 16, 2020•8 citations

Precise Frequency Measurements Using a Superconducting Cavity Stabilized Oscillator

D. M. Strayer, N.-C. Yeh, Wencai Jiang +2 more

Many physics experiments call on improved resolution to better define the experimental results, thus improving tests of theories. Modern microwave technology combined with high-Q resonators can achieve frequency readout and control with resolutions up to a part in 10(exp 18). When the physical quantity in question in the experiment can be converted to a frequency or a change in frequency, a high-stability microwave oscillator can be applied to obtain state-of-the-art precision. In this work we describe the overall physical concepts and the required experimental procedures for optimizing a high-resolution frequency measurement system that employs a high-Q superconducting microwave cavity and a low-noise frequency synthesizer. The basic approach is to resolve the resonant frequencies of a high-Q (Q > 10(exp 10)) cavity to extremely high precision (one part in 10(exp 17)- 10(exp 18)). Techniques for locking the synthesizer frequency to a resonant frequency of the superconducting cavity to form an ultra-stable oscillator are described. We have recently set up an ultra-high-vacuum high-temperature annealing system to process superconducting niobium cavities, and have been able to consistently achieve Q > 10(exp 9). We have integrated high-Q superconducting cavities with a low-noise microwave synthesizer in a phase-locked-loop to verify the frequency stability of the system. Effects that disturb the cavity resonant frequency (such as the temperature fluctuations and mechanical vibrations) and methods to mitigate those effects are also considered. Applicability of these techniques to experiments will be discussed, and our latest experimental progress in achieving high-resolution frequency measurements using the superconducting-cavity-stabilized-oscillator will be presented.

•Jan 1, 1999•0 citations

Near-ground-state cooling in electromechanics using measurement-based feedback and a Josephson traveling-wave parametric amplifier

Ewa Rej, Richa Cutting, Joe Depellette +6 more

Feedback-based control of nano- and micromechanical resonators can enable the study of macroscopic quantum phenomena and also sensitive force measurements. Here, we demonstrate the feedback cooling of a low-loss and high-stress macroscopic SiN membrane resonator close to its quantum ground state. We use the microwave optomechanical platform, where the resonator is coupled to a microwave cavity. The experiment utilizes a Josephson traveling-wave parametric amplifier, which is nearly quantum-limited in added noise, and is important for mitigating resonator heating due to system noise in the feedback loop. We reach a thermal phonon number as low as 1.6, which is limited primarily by microwave-induced heating. We also discuss the sideband asymmetry observed when a weak microwave tone for independent readout is applied in addition to other tones used for the cooling. In a typical situation, the asymmetry can be attributed to the quantum-mechanical imbalance between emission and absorption. In specific situations, however, we find that the asymmetry is an artifact due to coupling of different sideband processes by cavity nonlinearity under multitone irradiation.

arXiv:2403.02319•Physical Review Applied•Mar 5, 2025•9 citations
Microwave cavities are commonly used in many experiments, including optomechanics, magnetic field sensing, magnomechanics, and circuit quantum electrodynamics. Noise, such as variations in the magnetic field or mechanical vibrations, can cause fluctuations of the natural frequency of the cavity, creating challenges in operating them in experiments. To overcome these challenges, we demonstrate a dynamic feedback system implemented by the locking of a microwave drive to the noisy cavity. A homodyne-interferometer scheme monitors the cavity resonance fluctuations due to low-frequency noise, which is mitigated by frequency modulating the microwave generator. The feedback has a bandwidth of 400 Hz, with a reduction of cavity fluctuations by 85\mathrm{%} integrating up to a bandwidth of 2 kHz. Moreover, the cavity resonance frequency fluctuations are reduced by 73\mathrm{%}. This scheme can be scaled to enable multitone experiments locked to the same feedback signal. As a demonstration, we apply the feedback to an optomechanical experiment and implement a cavity-locked multitone mechanical measurement. As low-frequency cavity frequency noise can be a limiting factor in many experiments, the multitone microwave locking technique presented here is expected to be relevant for a wide range of microwave-cavity experiments.
Resonance-frequency fluctuations can limit the sensitivity and stability of superconducting microwave cavities used for qubit readout, optomechanical displacement sensing, and magnetic flux detection. Here, we demonstrate the suppression of resonance-frequency fluctuations by locking a noisy nonlinear superconducting microwave cavity to a strong pump tone. The Kerr nonlinearity of this system, whereby the resonance frequency depends on the intracavity field amplitude, gives rise to an intrinsic feedback mechanism that enables passive stabilization without active external feedback. Using two-tone spectroscopy, we experimentally characterize the intrinsic nonlinear feedback mechanism and investigate its temporal stability through Allan deviation analysis. The frequency fluctuations of the locked cavity mode are reduced by nearly two orders of magnitude, reaching the 1/f1/f1/f noise floor, without continuous frequency tracking or active control. Kerr locking provides a general approach for self-stabilizing nonlinear microwave resonators by suppressing low-frequency cavity noise while preserving sensitivity to signals outside the locking bandwidth. This approach may benefit a broad range of systems, including SQUID-based resonators, optomechanical devices, and parametric amplifiers.
High-gain amplifiers of electromagnetic signals operating near the quantum limit are crucial for quantum information systems and ultrasensitive quantum measurements.However, the existing techniques have a limited gain-bandwidth product and only operate with weak input signals.Here, we demonstrate a two-port optomechanical scheme for amplification and routing of microwave signals, a system that simultaneously performs high-gain amplification and frequency conversion in the quantum regime.Our amplifier, implemented in a two-cavity microwave optomechanical device, shows 41 dB of gain and has a high dynamic range, handling input signals up to 10 13 photons per second, 3 orders of magnitude more than corresponding Josephson parametric amplifiers.We show that although the active medium, the mechanical resonator, is at a high temperature far from the quantum limit, only 4.6 quanta of noise is added to the input signal.Our method can be readily applied to a wide variety of optomechanical systems, including hybrid optical-microwave systems, creating a universal hub for signals at the quantum level.
We successfully demonstrate low-frequency noise suppression in the resonant-frequency fluctuations of a cavity-embedded Cooper-pair transistor (cCPT) driven at single-photon occupancy. In particular, we report a reduction in the resonant-frequency fluctuations caused by the internal charge noise over a bandwidth of approximately 1.4kHz1.4\phantom{\rule{0.2em}{0ex}}\text{kHz}1.4kHz when the cavity is driven at an average photon number n=10n=10n=10 and a bandwidth of 11 Hz for an average n=1n=1n=1. The gate-dependent tunability of the cCPT allows us to implement a feedback scheme derived from the Pound-Drever-Hall locking technique. This reduces fluctuations due to intrinsic charge noise, which otherwise interfere with the operation of the cCPT as a near quantum-limited electrometer. Our technique can be generalized to achieve frequency stabilization in tunable microwave resonators that play a vital role in today's quantum computing architectures, thereby moderating the limitations in detection caused by the intrinsic 1/f1/f1/f noise on such circuit devices. The work discusses the various aspects relating to the operation of a fully functional feedback loop down to the single-photon level.
High-gain and low-noise signal amplification is a valuable tool in various cryogenic microwave experiments. A microwave optomechanical device, in which a vibrating capacitor modulates the frequency of a microwave cavity, is one technique that is able to amplify microwave signals with high gain and large dynamical range. Such optomechanical amplifiers typically rely on strong backaction of microwave photons on the mechanical mode achieved in the sideband-resolved limit of optomechanics. Here, we observe microwave amplification in an optomechanical cavity in the extremely unresolved sideband limit. A large gain is observed for any detuning of the single pump tone within the cavity linewidth, a clear indication that the amplification is not induced by dynamical backaction. By being able to amplify for any detuning of the pump signal, the amplification center frequency can be tuned over the entire range of the broad cavity linewidth. Additionally, by providing microwave amplification without mechanical amplification, we predict that by using this scheme it is possible to achieve near-quantum-limited microwave amplification despite a large thermal occupation of the mechanical mode.
Many physics experiments call on improved resolution to better define the experimental results, thus improving tests of theories. Modern microwave technology combined with high-Q resonators can achieve frequency readout and control with resolutions up to a part in 10(exp 18). When the physical quantity in question in the experiment can be converted to a frequency or a change in frequency, a high-stability microwave oscillator can be applied to obtain state-of-the-art precision. In this work we describe the overall physical concepts and the required experimental procedures for optimizing a high-resolution frequency measurement system that employs a high-Q superconducting microwave cavity and a low-noise frequency synthesizer. The basic approach is to resolve the resonant frequencies of a high-Q (Q > 10(exp 10)) cavity to extremely high precision (one part in 10(exp 17)- 10(exp 18)). Techniques for locking the synthesizer frequency to a resonant frequency of the superconducting cavity to form an ultra-stable oscillator are described. We have recently set up an ultra-high-vacuum high-temperature annealing system to process superconducting niobium cavities, and have been able to consistently achieve Q > 10(exp 9). We have integrated high-Q superconducting cavities with a low-noise microwave synthesizer in a phase-locked-loop to verify the frequency stability of the system. Effects that disturb the cavity resonant frequency (such as the temperature fluctuations and mechanical vibrations) and methods to mitigate those effects are also considered. Applicability of these techniques to experiments will be discussed, and our latest experimental progress in achieving high-resolution frequency measurements using the superconducting-cavity-stabilized-oscillator will be presented.
Feedback-based control of nano- and micromechanical resonators can enable the study of macroscopic quantum phenomena and also sensitive force measurements. Here, we demonstrate the feedback cooling of a low-loss and high-stress macroscopic SiN membrane resonator close to its quantum ground state. We use the microwave optomechanical platform, where the resonator is coupled to a microwave cavity. The experiment utilizes a Josephson traveling-wave parametric amplifier, which is nearly quantum-limited in added noise, and is important for mitigating resonator heating due to system noise in the feedback loop. We reach a thermal phonon number as low as 1.6, which is limited primarily by microwave-induced heating. We also discuss the sideband asymmetry observed when a weak microwave tone for independent readout is applied in addition to other tones used for the cooling. In a typical situation, the asymmetry can be attributed to the quantum-mechanical imbalance between emission and absorption. In specific situations, however, we find that the asymmetry is an artifact due to coupling of different sideband processes by cavity nonlinearity under multitone irradiation.