arXiv:2303.02933 · Physical Review Applied

Cryogenic hyperabrupt strontium titanate varactors for sensitive reflectometry of quantum dots

Rafael S. Eggli, Simon Svab, Taras Patlatiuk, Dominique A. Trüssel, Miguel J. Carballido, Pierre Chevalier Kwon, Simon Geyer, Ang Li, Erik P. A. M. Bakkers, Andreas V. Kuhlmann, Dominik M. Zumbühl

Published Nov 28, 2023• 15 citations
arXivHTMLPDF

Abstract

Radio-frequency reflectometry techniques enable high-bandwidth readout of semiconductor quantum dots. Careful impedance matching of the resonant circuit is required to achieve high sensitivity, which, however, proves challenging at cryogenic temperatures. Gallium arsenide--based voltage-tunable capacitors, so-called varactor diodes, can be used for in situ tuning of the circuit impedance but deteriorate and fail at temperatures below 10 K and in magnetic fields. Here, we investigate a varactor based on strontium titanate with a hyperabrupt capacitance-voltage characteristic, i.e., a capacitance tunability similar to the best gallium arsenide--based devices. The varactor design introduced here is compact, scalable, and easy to wire bond, with an accessible capacitance range from 45 pF to 3.2 pF. We tune a resonant inductor-capacitor circuit to perfect impedance matching and observe robust temperature- and field-independent matching down to 11 mK and up to 2 T in-plane field. Finally, we perform gate-dispersive charge sensing on a germanium-silicon core-shell nanowire hole double quantum dot, paving the way toward gate-based single-shot spin readout. Our results bring small magnetic field--resilient highly tunable varactors to mK temperatures, expanding the toolbox of cryo-radio-frequency applications.

DOI
10.1103/physrevapplied.20.054056

Related papers

Quantum paraelectric varactors for radiofrequency measurements at millikelvin temperatures

P. Apostolidis, Byron J. Villis, Jacob F. Chittock-Wood +6 more

Abstract Radiofrequency reflectometry can provide fast and sensitive electrical read-out of charge and spin qubits in quantum dot devices coupled to resonant circuits. In situ frequency tuning and impedance matching of the resonator circuit using voltage-tunable capacitors (varactors) is needed to optimize read-out sensitivity, but the performance of conventional semiconductor- and ferroelectric-based varactors degrades substantially in the millikelvin temperature range relevant for solid-state quantum devices. Here we show that strontium titanate and potassium tantalate, materials which can exhibit quantum paraelectric behaviour with large field-tunable permittivity at low temperatures, can be used to make varactors with perfect impedance matching and resonator frequency tuning at 6 mK. We characterize the varactors at 6 mK in terms of their capacitance tunability, dissipative losses and magnetic field insensitivity. We use the quantum paraelectric varactors to optimize the radiofrequency read-out of carbon nanotube quantum dot devices, achieving a charge sensitivity of 4.8 μe Hz−1/2 and a capacitance sensitivity of 0.04 aF Hz−1/2.

arXiv:2007.03588•Nature Electronics•Aug 5, 2024•22 citations

Low-temperature tunable radio-frequency resonator for sensitive dispersive readout of nanoelectronic devices

David J. Ibberson, Lisa A. Ibberson, Geoff Smithson +3 more

We present a sensitive, tunable radio-frequency resonator designed to detect reactive changes in nanoelectronic devices down to dilution refrigerator temperatures. The resonator incorporates GaAs varicap diodes to allow electrical tuning of the resonant frequency and the coupling to the input line. We find a resonant frequency tuning range of 8.4 MHz at 55 mK that increases to 29 MHz at 1.5 K. To assess the impact on performance of different tuning conditions, we connect a quantum dot in a silicon nanowire field-effect transistor to the resonator and measure changes in the device capacitance caused by cyclic electron tunneling. At 250 mK, we obtain an equivalent charge sensitivity of 43 μe/Hz when the resonator and the line are impedance-matched and show that this sensitivity can be further improved to 31 μe/Hz by re-tuning the resonator. We understand this improvement by using an equivalent circuit model and demonstrate that for maximum sensitivity to capacitance changes, in addition to impedance matching, a high-quality resonator with low parasitic capacitance is desired.

arXiv:1807.07842•Applied Physics Letters•Mar 25, 2019•15 citations

On-board calibrated radio-frequency measurement at cryogenic temperatures for determination of SrTiO3-based capacitor properties

Akitomi Shirachi, Motoya Shinozaki, Y. Tomioka +7 more

Quantum computing has emerged as a promising technology for next-generation information processing, utilizing semiconductor quantum dots as one of the candidates for quantum bits. Radio-frequency (rf) reflectometry plays an important role in the readout of quantum dots but requires a precise rf measurement technique at cryogenic temperatures. While cryogenic calibration techniques, essential for rf reflectometry, have been developed, on-board calibration near the device remains an important challenge. In this study, we develop an on-board calibrated rf measurement system operating at 4 K for characterizing SrTiO3-based varactors, which are promising components for tunable impedance matching circuits. Our system enables accurate measurements by eliminating errors associated with long rf circuit lines. We investigate the effects of annealing conditions, crystal orientation, and Ca doping of SrTiO3 crystals on the varactor properties in the frequency range for rf reflectometry. Our results provide insights for optimizing these components for cryogenic rf applications in quantum information processing systems.

arXiv:2504.20311•Applied Physics Letters•Oct 13, 2025•0 citations

Evaluation of a physically defined silicon quantum dot for design of matching circuit for RF reflectometry charge sensing

Jun Kamioka, R. Matsuda, Raisei Mizokuchi +2 more

This paper reports on the extraction of the equivalent circuit model parameters of a physically defined silicon quantum dot at a cryogenic temperature and design of the impedance matching circuits to improve the performance of a charge sensor for radio-frequency (RF) reflectometry. The I-V characteristics and the S-parameters of the quantum dot device are measured around a Coulomb peak at 4.2 K. The measured results are modeled by an RC parallel circuit, and the model parameters for the quantum dot device were obtained. We consider three impedance matching circuits for RF reflectometry of a quantum dot: shunt capacitor-series inductor type, shunt inductor-series capacitor type, and shunt inductor-series inductor-type. We formulate and compare the sensitivity and bandwidth of RF reflectometry for the three types of circuits. The analysis should be useful for selecting the optimal matching circuit and the circuit parameters for given equivalent circuit parameters and working frequency. This procedure is demonstrated for a quantum dot with the characterized model circuit along with simulated performance. This design technique of matching circuit for RF reflectometry can be applied to any device that can be represented by an RC parallel circuit. These results will facilitate to realize fast semiconductor qubit readout in various quantum dot platforms.

AIP Advances•Mar 1, 2023•4 citations

Active impedance matching of a cryogenic radio frequency resonator for ion traps

M. Schubert, L. Kilzer, T. Dubielzig +3 more

A combination of direct current (DC) fields and high amplitude radio frequency (RF) fields is necessary to trap ions in a Paul trap. Such high electric RF fields are usually reached with the help of a resonator in close proximity to the ion trap. Ion trap based quantum computers profit from good vacuum conditions and low heating rates that cryogenic environments provide. However, an impedance matching network between the resonator and its RF source is necessary, as an unmatched resonator would require higher input power due to power reflection. The reflected power would not contribute to the RF trapping potential, and the losses in the cable induce additional heat into the system. The electrical properties of the matching network components change during cooling, and a cryogenic setup usually prohibits physical access to integrated components while the experiment is running. This circumstance leads to either several cooling cycles to improve the matching at cryogenic temperatures or the operation of poorly matched resonators. In this work, we demonstrate an RF resonator that is actively matched to the wave impedance of coaxial cables and the signal source. The active part of the matching circuit consists of a varactor diode array. Its capacitance depends on the DC voltage applied from outside the cryostat. We present measurements of the power reflection, the Q-factor, and higher harmonic signals resulting from the nonlinearity of the varactor diodes. The RF resonator is tested in a cryostat at room temperature and cryogenic temperatures, down to 4.3 K. A superior impedance matching for different ion traps can be achieved with this type of resonator.

Review of Scientific Instruments•Sep 1, 2022•3 citations

Impedancemetry of multiplexed quantum devices using an on-chip cryogenic complementary metal-oxide-semiconductor active inductor

Loïck Le Guevel, G. Billiot, Silvano De Franceschi +4 more

In the pursuit for scalable quantum processors, significant effort is being devoted to the development of cryogenic classical hardware for the control and readout of a growing number of qubits. In this manuscript, we present a novel approach called impedancemetry that is suitable for measuring the quantum capacitance of semiconductor qubits connected to a resonant LC-circuit. The impedancemetry circuit exploits the integration of a CMOS-based active inductor in the resonator with tunable resonance frequency and quality factor, enabling optimization of readout sensitivity for quantum devices. The realized cryogenic circuit allows fast impedance detection with a measured capacitance resolution down to 10 aF and an input-referred noise of 3.7 aF/Hz. At 4.2 K, the power consumption of the active inductor amounts to 120 μW, with an additional dissipation for on-chip current excitation (0.15 μW) and voltage amplification (2.9 mW) of the impedance measurement. Compared to commonly used schemes based on dispersive RF reflectometry which require mm-scale passive inductors, the circuit has a notably reduced footprint (50 μm × 60 μm), facilitating its integration in a scalable quantum-classical architecture. The impedancemetry method has been applied at 4.2 K to the detection of quantum effects in the gate capacitance of on-chip nanometric CMOS transistors that are individually addressed via multiplexing.

Chip•Sep 30, 2023•5 citations
Radio-frequency reflectometry techniques enable high-bandwidth readout of semiconductor quantum dots. Careful impedance matching of the resonant circuit is required to achieve high sensitivity, which, however, proves challenging at cryogenic temperatures. Gallium arsenide--based voltage-tunable capacitors, so-called varactor diodes, can be used for in situ tuning of the circuit impedance but deteriorate and fail at temperatures below 10 K and in magnetic fields. Here, we investigate a varactor based on strontium titanate with a hyperabrupt capacitance-voltage characteristic, i.e., a capacitance tunability similar to the best gallium arsenide--based devices. The varactor design introduced here is compact, scalable, and easy to wire bond, with an accessible capacitance range from 45 pF to 3.2 pF. We tune a resonant inductor-capacitor circuit to perfect impedance matching and observe robust temperature- and field-independent matching down to 11 mK and up to 2 T in-plane field. Finally, we perform gate-dispersive charge sensing on a germanium-silicon core-shell nanowire hole double quantum dot, paving the way toward gate-based single-shot spin readout. Our results bring small magnetic field--resilient highly tunable varactors to mK temperatures, expanding the toolbox of cryo-radio-frequency applications.
Abstract Radiofrequency reflectometry can provide fast and sensitive electrical read-out of charge and spin qubits in quantum dot devices coupled to resonant circuits. In situ frequency tuning and impedance matching of the resonator circuit using voltage-tunable capacitors (varactors) is needed to optimize read-out sensitivity, but the performance of conventional semiconductor- and ferroelectric-based varactors degrades substantially in the millikelvin temperature range relevant for solid-state quantum devices. Here we show that strontium titanate and potassium tantalate, materials which can exhibit quantum paraelectric behaviour with large field-tunable permittivity at low temperatures, can be used to make varactors with perfect impedance matching and resonator frequency tuning at 6 mK. We characterize the varactors at 6 mK in terms of their capacitance tunability, dissipative losses and magnetic field insensitivity. We use the quantum paraelectric varactors to optimize the radiofrequency read-out of carbon nanotube quantum dot devices, achieving a charge sensitivity of 4.8 μe Hz−1/2 and a capacitance sensitivity of 0.04 aF Hz−1/2.
We present a sensitive, tunable radio-frequency resonator designed to detect reactive changes in nanoelectronic devices down to dilution refrigerator temperatures. The resonator incorporates GaAs varicap diodes to allow electrical tuning of the resonant frequency and the coupling to the input line. We find a resonant frequency tuning range of 8.4 MHz at 55 mK that increases to 29 MHz at 1.5 K. To assess the impact on performance of different tuning conditions, we connect a quantum dot in a silicon nanowire field-effect transistor to the resonator and measure changes in the device capacitance caused by cyclic electron tunneling. At 250 mK, we obtain an equivalent charge sensitivity of 43 μe/Hz when the resonator and the line are impedance-matched and show that this sensitivity can be further improved to 31 μe/Hz by re-tuning the resonator. We understand this improvement by using an equivalent circuit model and demonstrate that for maximum sensitivity to capacitance changes, in addition to impedance matching, a high-quality resonator with low parasitic capacitance is desired.
Quantum computing has emerged as a promising technology for next-generation information processing, utilizing semiconductor quantum dots as one of the candidates for quantum bits. Radio-frequency (rf) reflectometry plays an important role in the readout of quantum dots but requires a precise rf measurement technique at cryogenic temperatures. While cryogenic calibration techniques, essential for rf reflectometry, have been developed, on-board calibration near the device remains an important challenge. In this study, we develop an on-board calibrated rf measurement system operating at 4 K for characterizing SrTiO3-based varactors, which are promising components for tunable impedance matching circuits. Our system enables accurate measurements by eliminating errors associated with long rf circuit lines. We investigate the effects of annealing conditions, crystal orientation, and Ca doping of SrTiO3 crystals on the varactor properties in the frequency range for rf reflectometry. Our results provide insights for optimizing these components for cryogenic rf applications in quantum information processing systems.
This paper reports on the extraction of the equivalent circuit model parameters of a physically defined silicon quantum dot at a cryogenic temperature and design of the impedance matching circuits to improve the performance of a charge sensor for radio-frequency (RF) reflectometry. The I-V characteristics and the S-parameters of the quantum dot device are measured around a Coulomb peak at 4.2 K. The measured results are modeled by an RC parallel circuit, and the model parameters for the quantum dot device were obtained. We consider three impedance matching circuits for RF reflectometry of a quantum dot: shunt capacitor-series inductor type, shunt inductor-series capacitor type, and shunt inductor-series inductor-type. We formulate and compare the sensitivity and bandwidth of RF reflectometry for the three types of circuits. The analysis should be useful for selecting the optimal matching circuit and the circuit parameters for given equivalent circuit parameters and working frequency. This procedure is demonstrated for a quantum dot with the characterized model circuit along with simulated performance. This design technique of matching circuit for RF reflectometry can be applied to any device that can be represented by an RC parallel circuit. These results will facilitate to realize fast semiconductor qubit readout in various quantum dot platforms.
A combination of direct current (DC) fields and high amplitude radio frequency (RF) fields is necessary to trap ions in a Paul trap. Such high electric RF fields are usually reached with the help of a resonator in close proximity to the ion trap. Ion trap based quantum computers profit from good vacuum conditions and low heating rates that cryogenic environments provide. However, an impedance matching network between the resonator and its RF source is necessary, as an unmatched resonator would require higher input power due to power reflection. The reflected power would not contribute to the RF trapping potential, and the losses in the cable induce additional heat into the system. The electrical properties of the matching network components change during cooling, and a cryogenic setup usually prohibits physical access to integrated components while the experiment is running. This circumstance leads to either several cooling cycles to improve the matching at cryogenic temperatures or the operation of poorly matched resonators. In this work, we demonstrate an RF resonator that is actively matched to the wave impedance of coaxial cables and the signal source. The active part of the matching circuit consists of a varactor diode array. Its capacitance depends on the DC voltage applied from outside the cryostat. We present measurements of the power reflection, the Q-factor, and higher harmonic signals resulting from the nonlinearity of the varactor diodes. The RF resonator is tested in a cryostat at room temperature and cryogenic temperatures, down to 4.3 K. A superior impedance matching for different ion traps can be achieved with this type of resonator.
In the pursuit for scalable quantum processors, significant effort is being devoted to the development of cryogenic classical hardware for the control and readout of a growing number of qubits. In this manuscript, we present a novel approach called impedancemetry that is suitable for measuring the quantum capacitance of semiconductor qubits connected to a resonant LC-circuit. The impedancemetry circuit exploits the integration of a CMOS-based active inductor in the resonator with tunable resonance frequency and quality factor, enabling optimization of readout sensitivity for quantum devices. The realized cryogenic circuit allows fast impedance detection with a measured capacitance resolution down to 10 aF and an input-referred noise of 3.7 aF/Hz. At 4.2 K, the power consumption of the active inductor amounts to 120 μW, with an additional dissipation for on-chip current excitation (0.15 μW) and voltage amplification (2.9 mW) of the impedance measurement. Compared to commonly used schemes based on dispersive RF reflectometry which require mm-scale passive inductors, the circuit has a notably reduced footprint (50 μm × 60 μm), facilitating its integration in a scalable quantum-classical architecture. The impedancemetry method has been applied at 4.2 K to the detection of quantum effects in the gate capacitance of on-chip nanometric CMOS transistors that are individually addressed via multiplexing.