We present a sensitive, tunable radio-frequency resonator designed to detect reactive changes in nanoelectronic devices down to dilution refrigerator temperatures. The resonator incorporates GaAs varicap diodes to allow electrical tuning of the resonant frequency and the coupling to the input line. We find a resonant frequency tuning range of 8.4 MHz at 55 mK that increases to 29 MHz at 1.5 K. To assess the impact on performance of different tuning conditions, we connect a quantum dot in a silicon nanowire field-effect transistor to the resonator and measure changes in the device capacitance caused by cyclic electron tunneling. At 250 mK, we obtain an equivalent charge sensitivity of 43 μe/Hz when the resonator and the line are impedance-matched and show that this sensitivity can be further improved to 31 μe/Hz by re-tuning the resonator. We understand this improvement by using an equivalent circuit model and demonstrate that for maximum sensitivity to capacitance changes, in addition to impedance matching, a high-quality resonator with low parasitic capacitance is desired.
We present a sensitive, tunable radio-frequency resonator designed to detect reactive changes in nanoelectronic devices down to dilution refrigerator temperatures. The resonator incorporates GaAs varicap diodes to allow electrical tuning of the resonant frequency and the coupling to the input line. We find a resonant frequency tuning range of 8.4 MHz at 55 mK that increases to 29 MHz at 1.5 K. To assess the impact on performance of different tuning conditions, we connect a quantum dot in a silicon nanowire field-effect transistor to the resonator and measure changes in the device capacitance caused by cyclic electron tunneling. At 250 mK, we obtain an equivalent charge sensitivity of 43 μe/Hz when the resonator and the line are impedance-matched and show that this sensitivity can be further improved to 31 μe/Hz by re-tuning the resonator. We understand this improvement by using an equivalent circuit model and demonstrate that for maximum sensitivity to capacitance changes, in addition to impedance matching, a high-quality resonator with low parasitic capacitance is desired.
Abstract Radiofrequency reflectometry can provide fast and sensitive electrical read-out of charge and spin qubits in quantum dot devices coupled to resonant circuits. In situ frequency tuning and impedance matching of the resonator circuit using voltage-tunable capacitors (varactors) is needed to optimize read-out sensitivity, but the performance of conventional semiconductor- and ferroelectric-based varactors degrades substantially in the millikelvin temperature range relevant for solid-state quantum devices. Here we show that strontium titanate and potassium tantalate, materials which can exhibit quantum paraelectric behaviour with large field-tunable permittivity at low temperatures, can be used to make varactors with perfect impedance matching and resonator frequency tuning at 6 mK. We characterize the varactors at 6 mK in terms of their capacitance tunability, dissipative losses and magnetic field insensitivity. We use the quantum paraelectric varactors to optimize the radiofrequency read-out of carbon nanotube quantum dot devices, achieving a charge sensitivity of 4.8 μe Hz−1/2 and a capacitance sensitivity of 0.04 aF Hz−1/2.
Radio-frequency reflectometry techniques enable high-bandwidth readout of semiconductor quantum dots. Careful impedance matching of the resonant circuit is required to achieve high sensitivity, which, however, proves challenging at cryogenic temperatures. Gallium arsenide--based voltage-tunable capacitors, so-called varactor diodes, can be used for in situ tuning of the circuit impedance but deteriorate and fail at temperatures below 10 K and in magnetic fields. Here, we investigate a varactor based on strontium titanate with a hyperabrupt capacitance-voltage characteristic, i.e., a capacitance tunability similar to the best gallium arsenide--based devices. The varactor design introduced here is compact, scalable, and easy to wire bond, with an accessible capacitance range from 45 pF to 3.2 pF. We tune a resonant inductor-capacitor circuit to perfect impedance matching and observe robust temperature- and field-independent matching down to 11 mK and up to 2 T in-plane field. Finally, we perform gate-dispersive charge sensing on a germanium-silicon core-shell nanowire hole double quantum dot, paving the way toward gate-based single-shot spin readout. Our results bring small magnetic field--resilient highly tunable varactors to mK temperatures, expanding the toolbox of cryo-radio-frequency applications.
Frequency-multiplexed radio-frequency (RF) reflectometry is a promising technique for large-scale quantum dot-based qubit systems because it enables simultaneous readout of multiple qubits and helps to reduce the wiring density in peripheral circuits. However, in the conventional L-C-type matching circuits, resonator frequency tunability is limited by poor design flexibility of the shunt capacitance and hence the circuit. Recently, L-L-type matching circuits comprising a series and a shunt inductor have been proposed to address this issue. Here, we report RF reflectometry readout of silicon quantum dot-based charge sensors embedded in L-L-type circuits. We determine the inductance values for target resonance frequencies based on our equivalent circuit model that incorporates the parasitic elements of the inductors and demonstrate resonator frequency tunability of up to 1 GHz with 3-dB resonator bandwidths on the order of MHz. The measured conductance sensitivities, on the order of 10−5(e2/h)/Hz at 4 K, are only moderately dependent on the resonance frequency up to 630 MHz. These results highlight the prospects of L-L-type matching circuits for rapid and multiplex reflectometry readout of semiconductor spin qubits.
This thesis focuses on implementing radio frequency (rf) reflectometry techniques for dispersive detection of charge and spin dynamics in nanoscale devices. I have investigated three aspects of rf reflectometry using state-of-the-art silicon (Si) complementary metal-oxide-semiconductor (CMOS) nanowire field effect transistors (NWFETs). First, a high-sensitivity capacitive gate-based charge sensor is developed by optimising the external matching circuit to detect capacitive changes in the high frequency resonator. A new circuit topology is used where superconducting niobium nitride (NbN) inductor is connected in parallel with a single-gate Si NWFET resulting in resonators with loaded Q-factors in the 400-800 range. For a resonator operating at 330 MHz, I have achieved a charge sensitivity of 7.7 μe/Hz and, when operating at 616 MHz, I get 1.3 μe/Hz. This gate-based sensor can be used for fast, accurate and scalable techniques for quantum state readout in Si CMOS based quantum computing. Second, this new circuit topology for the resonator is used with a dual-gate Si NWFET. This dual-gate device geometry provides access to a double quantum dot (DQD) system in few electron regime. The spin-state of the two-electron DQD system is detected dispersively using Pauli spin blockade between joint singlet S(2,0) and triplet T−(1,1) states in a finite magnetic field B. The singlet-triplet relaxation time T1 at B=4.5~T is measured to be $\sim$1 ms using standard homodyne detection technique. Third, I expand the range of applications of gate-based sensing to accurate temperature measurements. I have experimentally demonstrated a primary thermometer by embedding a single-gate Si NWFET with the rf capacitive gate-based sensor. The thermometer, termed as gate-based electron thermometer (GET), relies on cyclic electron tunneling between discrete energy levels of a quantum dot and a single electron reservoir in the NWFET. I have found that the full-width-half-maximum (FWHM) of the resonator phase response depends linearly with temperature via well known physical law by using the ratio kB/e between the Boltzmann constant and the electron charge. The GET is also found to be magnetic field independent like other primary thermometers such as Coulomb blockade and shot noise thermometers.
Radio frequency (RF) reflectometry is a well understood measurement technique in common use by RF engineers today. This technique has been applied at low temperature to probe the impedance of nanoscale devices for over two decades. These measurements typically employ basic resonant impedance transformers to bring the device impedance close to the characteristic impedance of the measurement apparatus. In 2013 it was discovered by Colless et al. that reflectometry could be used to measure extremely small impedance changes in a gate coupled to a quantum dot to directly probe the charge state of the dot. This has simplified measurements of certain nanoscale devices including single electron boxes (SEBs) and semiconductor qubits. Despite the maturity of RF reflectometry measurements in general, researchers working at low temperature continue to make basic mistakes in their measurements. The root cause of most of these mistakes is the failure to properly calibrate the measurement apparatus. In some cases this leads researchers to unrealistic conclusions when trying to match measurements to theory. This dissertation demonstrates that a low temperature RF calibration can be very easy and straightforward using inexpensive, off the shelf SMA terminators as calibration standards. A proper calibration allows for direct quantitative comparisons between data measured on different reflectometers or between data and simulations. The consistency between measurements and simulations then allows for straightforward design and implementation of improved impedance transformers, increasing the SNR of extremely sensitive measurements, with simple data-based simulations. A new type of single electron device, the capacitively coupled RF single electron transistor (CSET) is proposed and demonstrated which can rival the traditional RF SET in sensitivity but integrates more effectively into arrays and may offer a level of resistance to electrostatic discharge damage.