Neutral quantum absorbers in optical lattices have emerged as a leading platform for achieving clocks with exquisite spectroscopic resolution.However, the studies of these clocks and their systematic shifts have so far been limited to atoms.Here, we extend this architecture to an ensemble of diatomic molecules and experimentally realize an accurate lattice clock based on pure molecular vibration.We evaluate the leading systematics, including the characterization of nonlinear trap-induced light shifts, achieving a total systematic uncertainty of 4.6 × 10 -14 .The absolute frequency of the vibrational splitting is measured to be 31 825 183 207 592.8(5.1)Hz, enabling the dissociation energy of our molecule to be determined with record accuracy.Our results represent an important milestone in molecular spectroscopy and THzfrequency standards, and may be generalized to other neutral molecular species with applications for fundamental physics, including tests of molecular quantum electrodynamics and the search for new interactions.
Neutral quantum absorbers in optical lattices have emerged as a leading platform for achieving clocks with exquisite spectroscopic resolution.However, the studies of these clocks and their systematic shifts have so far been limited to atoms.Here, we extend this architecture to an ensemble of diatomic molecules and experimentally realize an accurate lattice clock based on pure molecular vibration.We evaluate the leading systematics, including the characterization of nonlinear trap-induced light shifts, achieving a total systematic uncertainty of 4.6 × 10 -14 .The absolute frequency of the vibrational splitting is measured to be 31 825 183 207 592.8(5.1)Hz, enabling the dissociation energy of our molecule to be determined with record accuracy.Our results represent an important milestone in molecular spectroscopy and THzfrequency standards, and may be generalized to other neutral molecular species with applications for fundamental physics, including tests of molecular quantum electrodynamics and the search for new interactions.
Researchers have attained a 100-fold increase in the accuracy of a molecular clock that could serve as a terahertz-frequency standard and as a platform for investigating new physics.By Charles Day M olecules can rotate, vibrate, and twist.With each of those degrees of freedom comes a ladder of quantized energy levels whose spacings typically occupy the terahertz band.Because the ladder's steps are tiny, molecules are exquisitely sensitive probes of internal and external fields.But the sensitivity complicates the two principal operations needed to build a working probe: cooling and trapping.In 2019 Tanya Zelevinsky of Columbia University and her collaborators overcame those hurdles to measure a vibrational transition in diatomic strontium to one part in 10 12 .Now, after four years of improvements to the experiment, the team has attained an accuracy 100 times greater [1].Zelevinsky and her team chose Sr 2 for their molecular clock Running a molecular lattice clock requires multiple lasers, mirrors, prisms, and other optical components.
Over the past few decades, rapid development of laser cooling techniques and narrow-linewidth lasers have allowed atom-based quantum clocks to achieve unprecedented precision. Techniques originally developed for atomic clocks can be extended to ultracold molecules, with applications ranging from quantum-state-controlled ultracold chemistry to searches for new physics. Because of the richness of molecular structure, quantum metrology based on molecules provides possibilities for testing physics that is beyond the scope of traditional atomic clocks. This thesis presents the work performed to establish a state-of-the-art quantum clock based on ultracold molecules. The molecular clock is based on a frequency difference between two vibrational levels in the electronic ground state of 88Sr2 diatomic molecules. Such a clock allows us test molecular QED, improve constraints on nanometer-scale gravity, and potentially provide a model-independent test of temporal variations of the proton-electron mass ratio. Trap-insensitive spectroscopy is crucial for extending coherent molecule-light interactions and achieving a high quality factor Q. We have demonstrated a magic wavelength technique for molecules by manipulating the optical lattice frequency near narrow polarizability resonances. This general technique allows us to increase the coherence time to tens of ms, an improvement of a factor of several thousand, and to narrow the linewidth of a 25 THz vibrational transition initially to 30 Hz. This width corresponds to the quality factor Q=8x10^11. Besides the molecular quantum metrology, investigations of novel phenomena in state-selected photodissociation are also described in this thesis, including magnetic-field control of photodissociation and observation of the crossover from ultracold to quasiclassical chemistry.
— Modern capabilities in quantum state engineering of ultracold matter and precise control of light fields now permit accurate control of interactions between matter and field to suit applications for precision tests of fundamental physics. We report on our recent development of a highly stable and accurate optical atomic clock based on ultracold neutral Sr atoms confined in an optical lattice. We discuss precision tools for the lattice clock, including stabilized lasers with sub-Hz linewidth, femtosecond-comb based technology allowing accurate clock comparison in both microwave and optical domains, and clock transfer over optical fibers. With microkelvin Sr atoms confined in an optical lattice that provide a zero differential a.c. Stark shift between two clock states, we achieve a resonance quality factor >2×10 on the S0 − P0 doubly forbidden Sr clock transition at 698 nm. High resolution spectroscopy of spin-polarized atoms is used for both high-performance clock operations and accurate atomic structure measurement. The overall systematic uncertainty of the clock has been evaluated at the 10−16 level, while the stability approaches low 10−15 at 1 s. These developments in precise engineering of lightatom interactions can be extended to the field of ultracold molecules, bringing new prospects for precision measurements, quantum control, and determinations of the constancy of the fundamental constants.
We report an optical lattice clock with a total systematic uncertainty of 8.1×10^{-19} in fractional frequency units, representing the lowest uncertainty of any clock to date. The clock relies on interrogating the ultranarrow ^{1}S_{0}→^{3}P_{0} transition in a dilute ensemble of fermionic strontium atoms trapped in a vertically-oriented, shallow, one-dimensional optical lattice. Using imaging spectroscopy, we previously demonstrated record high atomic coherence time and measurement precision enabled by precise control of collisional shifts and the lattice light shift. In this work, we revise the black body radiation shift correction by evaluating the 5s4d ^{3}D_{1} lifetime, necessitating precise characterization and control of many body effects in the 5s4d ^{3}D_{1} decay. Last, we measure the second order Zeeman coefficient on the least magnetically sensitive clock transition. All other systematic effects have uncertainties below 1×10^{-19}.
Molecular lattice clocks enable the search for new physics, such as fifth forces or temporal variations of fundamental constants, in a manner complementary to atomic clocks. Blackbody radiation (BBR) is a major contributor to the systematic error budget of conventional atomic clocks and is notoriously difficult to characterize and control. Here, we combine infrared Stark-shift spectroscopy in a molecular lattice clock and modern quantum chemistry methods to characterize the polarizabilities of the Sr_{2} molecule from dc to infrared. Using this description, we determine the static and dynamic blackbody radiation shifts for all possible vibrational clock transitions to the 10^{-16} level. This constitutes an important step toward millihertz-level molecular spectroscopy in Sr_{2} and provides a framework for evaluating BBR shifts in other homonuclear molecules.
An optical lattice clock probes a spectrally narrow electronic transition in an ensemble of optically trapped, laser-cooled atoms, for use as a time and frequency standard. To date, several lattice clocks have been demonstrated with superior stability and accuracy compared to primary frequency standards based on microwave transitions. Yet, the question of which atomic system (including the element and isotope) performs best as a lattice clock remains unsettled. This thesis describes the first detailed investigation of an optical lattice clock using a spin-1/2 isotope of the ytterbium atom. A spin-1/2 system possesses several advantages over higher-spin systems, including a simplified level structure (allowing for straightforward manipulation of the nuclear spin state) and the absence of any tensor light shift from the confining optical lattice. Moreover, the ytterbium atom (Yb) stands among the leading lattice clock candidates, offering a high-performance optical clock with some degree of experimental simplicity. The frequency stability of the Yb clock is highlighted by resolving an ultra-narrow clock spectrum with a full-width at half-maximum of 1 Hz, corresponding to a record quality factor Q = ν0/Δν = 5 × 1014. Moreover, this system can be highly accurate, which is demonstrated by characterizing the Yb clock frequency at the 3 × 10-16 level of fractional uncertainty, with further progress toward a ten-fold improvement also presented. To reach this low level of uncertainty required careful consideration of important systematic errors, including the identification of the Stark-canceling wavelength, where the clock’s sensitivity to the lattice intensity is minimized, a precise determination of the static polarizability of the clock transition, and the measurement and control of atom-atom collisions.