arXiv:2403.10664 · Physical Review Letters

Clock with 8 × 10 − 19 Systematic Uncertainty

Alexander Aeppli, Kyungtae Kim, William Warfield, Marianna S. Safronova, Jun Ye

Published Jul 10, 2024• 246 citations
arXivHTMLPDF

Abstract

We report an optical lattice clock with a total systematic uncertainty of 8.1×10^{-19} in fractional frequency units, representing the lowest uncertainty of any clock to date. The clock relies on interrogating the ultranarrow ^{1}S_{0}→^{3}P_{0} transition in a dilute ensemble of fermionic strontium atoms trapped in a vertically-oriented, shallow, one-dimensional optical lattice. Using imaging spectroscopy, we previously demonstrated record high atomic coherence time and measurement precision enabled by precise control of collisional shifts and the lattice light shift. In this work, we revise the black body radiation shift correction by evaluating the 5s4d ^{3}D_{1} lifetime, necessitating precise characterization and control of many body effects in the 5s4d ^{3}D_{1} decay. Last, we measure the second order Zeeman coefficient on the least magnetically sensitive clock transition. All other systematic effects have uncertainties below 1×10^{-19}.

DOI
10.1103/physrevlett.133.023401

Related papers

Uncertainty Evaluation of an 171Yb Optical Lattice Clock at NMIJ

Takumi Kobayashi, Daisuke Akamatsu, Yusuke Hisai +6 more

We report an uncertainty evaluation of an171Yb optical lattice clock with a total fractional uncertainty of 3.6 × 10-16, which is mainly limited by the lattice-induced light shift and the blackbody radiation shift. Our evaluation of the lattice-induced light shift, the density shift, and the second-order Zeeman shift is based on an interleaved measurement where we measure the frequency shift using the alternating stabilization of a clock laser to the 6s21S0-6s6p3P0clock transition with two different experimental parameters. In the present evaluation, the uncertainties of two sensitivity coefficients for the lattice-induced hyperpolarizability shift d incorporated in a widely used light shift model by RIKEN and the second-order Zeeman shift aZare improved compared with the uncertainties of previous coefficients. The hyperpolarizability coefficient d is determined by investigating the trap potential depth and the light shifts at the lattice frequencies near the two-photon transitions 6s6p3P0-6s8p3P0, 6s8p3P2, and 6s5f3F2. The obtained values are d=-1.1(4) μHz and aZ=-6.6(3) Hz/mT2. These improved coefficients should reduce the total systematic uncertainties of Yb lattice clocks at other institutes.

arXiv:1901.00954•IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Sep 18, 2018•28 citations

Evaluation of Lattice Light Shift at Low 10−19 Uncertainty for a Shallow Lattice Sr Optical Clock

Kyungtae Kim, Alexander Aeppli, Tobias Bothwell +1 more

A Wannier-Stark optical lattice clock has demonstrated unprecedented measurement precision for optical atomic clocks. We present a systematic evaluation of the lattice light shift, a necessary next step for establishing this system as an accurate atomic clock. With precise control of the atomic motional states in the lattice, we report accurate measurements of the multipolar and the hyperpolar contributions and the operational lattice light shift with a fractional frequency uncertainty of 3.5×10^{-19}.

arXiv:2210.16374•Physical Review Letters•Mar 15, 2023•72 citations

Systematic evaluation of a 171Yb optical clock by synchronous comparison between two lattice systems

Qi Gao, Min Zhou, Chengyin Han +12 more

Abstract Optical clocks are the most precise measurement devices. Here we experimentally characterize one such clock based on the 1S0-3P0 transition of neutral 171Yb atoms confined in an optical lattice. Given that the systematic evaluation using an interleaved stabilization scheme is unable to avoid noise from the clock laser, synchronous comparisons against a second 171Yb lattice system were implemented to accelerate the evaluation. The fractional instability of one clock falls below 4 × 10−17 after an averaging over a time of 5,000 seconds. The systematic frequency shifts were corrected with a total uncertainty of 1.7 × 10−16. The lattice polarizability shift currently contributes the largest source. This work paves the way to measuring the absolute clock transition frequency relative to the primary Cs standard or against the International System of Units (SI) second.

Scientific Reports•May 16, 2018•44 citations

Precision measurement of fermionic collisions using an 87Sr optical lattice clock with 1 × 10-16 inaccuracy

Matthew D. Swallows, Gretchen K. Campbell, Andrew D. Ludlow +6 more

We describe recent progress on the JILA Sr optical frequency standard, which has a systematic uncertainty at the 10(¿16) fractional frequency level. The dominant contributions to the systematic error are from blackbody radiation shifts and collisional shifts. We discuss the blackbody radiation shift and propose measurements and experimental protocols that should reduce its systematic contribution. We discuss how collisional frequency shifts can arise in an optical lattice clock employing fermionic atoms, and experimentally demonstrate how the uncertainty in this density-dependent correction to the clock frequency is reduced.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Mar 1, 2010•13 citations

A Multiplexed Strontium Optical Lattice Clock

Jonathan Dolde

Optical atomic clocks have spurred a range of precision frequency comparison experiments and proposals including tests of general relativity, gravitational wave detection, and relativistic geodesy. Current measurements using optical atomic clocks are often limited by the coherence of the clock laser rather than the atomic samples used as a frequency reference. In order to overcome the performance limits imposed by clock laser coherence, we realize a multiplexed optical clock system where multiple spatially resolved ensembles each consisting of thousands of strontium atoms trapped in a 1D optical lattice function as separate atomic frequency references that can be simultaneously interrogated with a shared clock laser. This scheme allows us to make differential frequency comparisons with a quantum projection noise limited fractional instability of 9.7(4)×10−18/ √τ and a differential fractional uncertainty of 8.9×10−20 after 3.3 hours of averaging. We then use this system to perform a lab-based test of the gravitational redshift at the centimeter scale, where we measure a fractional frequency gradient of [−12.4±0.7stat ±2.5sys]×10−19/cm, consistent with the predicted value of 10.9×10−19/cm. Having demonstrated that our differential comparisons are no longer limited by the local oscillator, we turn to fundamental limits on atom–atom coherence. We perform a direct decay measurement of the natural lifetime of the excited clock state 3P0 in 87Sr, in which we use measurements of simultaneously loaded high and low density atomic ensembles and compare decay rates of 87Sr and 88Sr to help isolate natural lifetime decay from other population dynamics. We measure a lifetime of 167+79 −40, which is consistent with previously reported experimental and theoretical values. Lastly, we demonstrate a hyperfine-resolved readout scheme in 87Sr that converts depolarization errors during interrogation into erasure errors, extending coherence times between ensembles in our optical lattice clock up to 150s using spin-echo measurements. These results taken together demonstrate the advantages of differential clock measurements that aren’t limited by clock laser coherence and how to characterize and improve on the performance limits that arise in that regime.

•May 1, 2026•0 citations

Improvements to a Strontium Optical Lattice Clock

Rees L. McNally

In 2013, for the first time ever, a many-atom optical lattice clock surpassed single ion clocks as the most stable, and accurate frequency standard in existence. Since this first result, continued improvements to the clock's accuracy and stability have been made. This work will focus on two of these major improvements. Firstly the frequency uncertainty was brought down to 2.5*10^-18, thanks in part to an accurate determination of the black body radiation shift, based on better characterization of the level structure of 87Sr. Secondly, a control modification will be demonstrated which provides 20% reduction in the standard deviation for the clock's frequency under differential measurement schemes. This represents a new record for clock accuracy, pushing performance towards the 10^-19 level.

•Jan 1, 2014•0 citations
We report an optical lattice clock with a total systematic uncertainty of 8.1×10^{-19} in fractional frequency units, representing the lowest uncertainty of any clock to date. The clock relies on interrogating the ultranarrow ^{1}S_{0}→^{3}P_{0} transition in a dilute ensemble of fermionic strontium atoms trapped in a vertically-oriented, shallow, one-dimensional optical lattice. Using imaging spectroscopy, we previously demonstrated record high atomic coherence time and measurement precision enabled by precise control of collisional shifts and the lattice light shift. In this work, we revise the black body radiation shift correction by evaluating the 5s4d ^{3}D_{1} lifetime, necessitating precise characterization and control of many body effects in the 5s4d ^{3}D_{1} decay. Last, we measure the second order Zeeman coefficient on the least magnetically sensitive clock transition. All other systematic effects have uncertainties below 1×10^{-19}.
We report an uncertainty evaluation of an171Yb optical lattice clock with a total fractional uncertainty of 3.6 × 10-16, which is mainly limited by the lattice-induced light shift and the blackbody radiation shift. Our evaluation of the lattice-induced light shift, the density shift, and the second-order Zeeman shift is based on an interleaved measurement where we measure the frequency shift using the alternating stabilization of a clock laser to the 6s21S0-6s6p3P0clock transition with two different experimental parameters. In the present evaluation, the uncertainties of two sensitivity coefficients for the lattice-induced hyperpolarizability shift d incorporated in a widely used light shift model by RIKEN and the second-order Zeeman shift aZare improved compared with the uncertainties of previous coefficients. The hyperpolarizability coefficient d is determined by investigating the trap potential depth and the light shifts at the lattice frequencies near the two-photon transitions 6s6p3P0-6s8p3P0, 6s8p3P2, and 6s5f3F2. The obtained values are d=-1.1(4) μHz and aZ=-6.6(3) Hz/mT2. These improved coefficients should reduce the total systematic uncertainties of Yb lattice clocks at other institutes.
A Wannier-Stark optical lattice clock has demonstrated unprecedented measurement precision for optical atomic clocks. We present a systematic evaluation of the lattice light shift, a necessary next step for establishing this system as an accurate atomic clock. With precise control of the atomic motional states in the lattice, we report accurate measurements of the multipolar and the hyperpolar contributions and the operational lattice light shift with a fractional frequency uncertainty of 3.5×10^{-19}.
Abstract Optical clocks are the most precise measurement devices. Here we experimentally characterize one such clock based on the 1S0-3P0 transition of neutral 171Yb atoms confined in an optical lattice. Given that the systematic evaluation using an interleaved stabilization scheme is unable to avoid noise from the clock laser, synchronous comparisons against a second 171Yb lattice system were implemented to accelerate the evaluation. The fractional instability of one clock falls below 4 × 10−17 after an averaging over a time of 5,000 seconds. The systematic frequency shifts were corrected with a total uncertainty of 1.7 × 10−16. The lattice polarizability shift currently contributes the largest source. This work paves the way to measuring the absolute clock transition frequency relative to the primary Cs standard or against the International System of Units (SI) second.
We describe recent progress on the JILA Sr optical frequency standard, which has a systematic uncertainty at the 10(¿16) fractional frequency level. The dominant contributions to the systematic error are from blackbody radiation shifts and collisional shifts. We discuss the blackbody radiation shift and propose measurements and experimental protocols that should reduce its systematic contribution. We discuss how collisional frequency shifts can arise in an optical lattice clock employing fermionic atoms, and experimentally demonstrate how the uncertainty in this density-dependent correction to the clock frequency is reduced.
Optical atomic clocks have spurred a range of precision frequency comparison experiments and proposals including tests of general relativity, gravitational wave detection, and relativistic geodesy. Current measurements using optical atomic clocks are often limited by the coherence of the clock laser rather than the atomic samples used as a frequency reference. In order to overcome the performance limits imposed by clock laser coherence, we realize a multiplexed optical clock system where multiple spatially resolved ensembles each consisting of thousands of strontium atoms trapped in a 1D optical lattice function as separate atomic frequency references that can be simultaneously interrogated with a shared clock laser. This scheme allows us to make differential frequency comparisons with a quantum projection noise limited fractional instability of 9.7(4)×10−18/ √τ and a differential fractional uncertainty of 8.9×10−20 after 3.3 hours of averaging. We then use this system to perform a lab-based test of the gravitational redshift at the centimeter scale, where we measure a fractional frequency gradient of [−12.4±0.7stat ±2.5sys]×10−19/cm, consistent with the predicted value of 10.9×10−19/cm. Having demonstrated that our differential comparisons are no longer limited by the local oscillator, we turn to fundamental limits on atom–atom coherence. We perform a direct decay measurement of the natural lifetime of the excited clock state 3P0 in 87Sr, in which we use measurements of simultaneously loaded high and low density atomic ensembles and compare decay rates of 87Sr and 88Sr to help isolate natural lifetime decay from other population dynamics. We measure a lifetime of 167+79 −40, which is consistent with previously reported experimental and theoretical values. Lastly, we demonstrate a hyperfine-resolved readout scheme in 87Sr that converts depolarization errors during interrogation into erasure errors, extending coherence times between ensembles in our optical lattice clock up to 150s using spin-echo measurements. These results taken together demonstrate the advantages of differential clock measurements that aren’t limited by clock laser coherence and how to characterize and improve on the performance limits that arise in that regime.
In 2013, for the first time ever, a many-atom optical lattice clock surpassed single ion clocks as the most stable, and accurate frequency standard in existence. Since this first result, continued improvements to the clock's accuracy and stability have been made. This work will focus on two of these major improvements. Firstly the frequency uncertainty was brought down to 2.5*10^-18, thanks in part to an accurate determination of the black body radiation shift, based on better characterization of the level structure of 87Sr. Secondly, a control modification will be demonstrated which provides 20% reduction in the standard deviation for the clock's frequency under differential measurement schemes. This represents a new record for clock accuracy, pushing performance towards the 10^-19 level.