Abstract Postselected weak measurement has shown significant potential for detecting small physical effects due to its unique weak-value-amplification phenomenon. Previous works suggest that Heisenberg-limit precision can be attained using optical coherent states. However, the observed Heisenberg scaling requires a measurement of the distribution of postselection probability, exhibiting no implementation pathway through conventional measurement paradigms. Here, we demonstrate that the output photons can also reach the Heisenberg scale by utilizing the Fisher information transfer effect, while this scenario exhibits enhanced robustness against dephasing noise. In addition, we consider the insertion of a power-recycling cavity and demonstrate its positive impact on the distribution of postselection. Our results enhance the quantum metrological advantages of the postselection strategy and broaden its application scope.
Abstract Postselected weak measurement has shown significant potential for detecting small physical effects due to its unique weak-value-amplification phenomenon. Previous works suggest that Heisenberg-limit precision can be attained using optical coherent states. However, the observed Heisenberg scaling requires a measurement of the distribution of postselection probability, exhibiting no implementation pathway through conventional measurement paradigms. Here, we demonstrate that the output photons can also reach the Heisenberg scale by utilizing the Fisher information transfer effect, while this scenario exhibits enhanced robustness against dephasing noise. In addition, we consider the insertion of a power-recycling cavity and demonstrate its positive impact on the distribution of postselection. Our results enhance the quantum metrological advantages of the postselection strategy and broaden its application scope.
Weak measurement has ignited extensive research and discussions in the field of quantum metrology due to its sufficient potential in quantum measurement applications. Recent studies demonstrate that weak measurement protocols, when integrated with quantum resources, can achieve Heisenberg scaling while maintaining technical noise advantages. However, scenarios involving dephasing noise have not been addressed, as such noise induces rapid degradation of Heisenberg scaling to the standard quantum limit. Here, we incorporate phase fluctuations, a typical dephasing noise, into three Heisenberg-scaling systems. We find that postselection invariably reduces the robustness of quantum systems. Compared to coherent pointer states, squeezed coherent pointer states can exhibit superior resilience against phase fluctuations through appropriate squeezing-parameter optimization. In addition, in entanglement-assisted systems, we can optimize the postselected angle to compensate for Fisher information loss induced by the postselection process. Our findings reveal that weak measurement exhibits inherent limitations in dephasing noise metrology compared to conventional measurement.
The weak-value-amplification (WVA) technique has been extensively considered and debated in the field of quantum precision measurement, largely owing to the reduced Fisher information caused by the low probability of successful postselection. In this work we show that, rather than the transverse-spatial-wave-function meter typically considered, using the optical coherent state as a meter, the WVA measurement can outperform the conventional measurement not involving the strategy of postselection. We also show that the postselection procedure involved in the WVA scheme can make a mixture of coherent states work better than a pure coherent state with identical average photon numbers. This is in contrast to the main result proved in the absence of postselection. The postselection strategy can also result in the precision of Heisenberg scaling with the photon numbers without using expensive quantum resources. The present work may stimulate further interest in postselection strategy for quantum precision measurements.
Weak measurement has garnered widespread interest for its ability to amplify small physical effects at the cost of low detection probabilities. Previous entanglement and recycling techniques enhance postselection efficiency and signal-to-noise ratio (SNR) of weak measurement from distinct perspectives. Here, we incorporate a power-recycling cavity into the entanglement-assisted weak measurement system. We obtain an improvement of both detection efficiency and Fisher information, driven by the combined effects of power cycling and entanglement. Furthermore, we analyze three types of errors: cavity power loss, walk-off errors, and readout errors. The conclusions suggest that entanglement is beneficial in mitigating the effects of cavity losses. Moreover, entanglement exacerbates the walk-off effect caused by recycling, but this detriment can be balanced by proper parameter selection. Additionally, power-recycling can complement entanglement in suppressing readout noise, thus enhancing the accuracy of the measurement results and recovering the lost Fisher information. This work delves deeper into the metrological advantages of weak measurement.
Abstract Improving the precision of measurements is a significant scientific challenge. Previous works suggest that in a photon-coupling scenario the quantum fisher information shows a quantum-enhanced scaling of N 2 , which in theory allows a better-than-classical scaling in practical measurements. In this work, utilizing mixed states with a large uncertainty and a post-selection of an additional pure system, we present a scheme to extract this amount of quantum fisher information and experimentally attain a practical Heisenberg scaling. We performed a measurement of a single-photon’s Kerr non-linearity with a Heisenberg scaling, where an ultra-small Kerr phase of ≃6 × 10 −8 rad was observed with a precision of ≃3.6 × 10 −10 rad. From the use of mixed states, the upper bound of quantum fisher information is improved to 2 N 2 . Moreover, by using an imaginary weak-value the scheme is robust to noise originating from the self-phase modulation.
Abstract Quantum metrology is being gradually studied for weak measurement systems. For weak measurement systems with a thermal state pointer, we find that in the displacement space corresponding to imaginary weak values, the maximal quantum Fisher information (QFI) after the postselection for an accepted event (conversely, the postselection for a rejected event) can attain a level of thermal fluctuation, without surpassing the total QFI, and further, that QFI which increases with increasing temperature can constantly improve measurement precision. These results are much better than those of weak measurement with a pure state (i.e. Gaussian state) pointer. On the other hand, in Kerr nonlinear interaction systems with weak measurement, and by using a thermal state pointer, we obtain in the phase space the accepted postselection and the postselected measurement both achieving the Heisenberg limit of quantum metrology, and showing that weak measurement with thermal states only obtain classical Fisher information (CFI) which increases with increasing temperature and achieves classical-enhanced scaling of N 2 . Moreover, weak measurement with thermal states has an advantage over that with coherent states or mixed states of light because generating these states with larger uncertainty is limited under current technology, but thermal states with larger uncertainly are very easy to achieve with increasing temperature in nature, such as for optical systems and optomechanical systems.
Postselected weak measurement has aroused broad interest for its distinctive ability to amplify small physical quantities. However, the low postselection efficiency to obtain a large weak value has been a big obstacle to its application in practice since it may waste resources, and reduce the measurement precision. An improved protocol was proposed in Pang et al., Phys. Rev. Lett. 113, 030401 (2014) to make the postselected weak measurement dramatically more efficient by using entanglement. Such a protocol can increase the Fisher information of the measurement to approximately saturate the well-known Heisenberg limit. In this paper, we review the entanglement-assisted protocol of postselected weak measurement in detail, and study its robustness against technical noises. We focus on readout errors. Readout errors can greatly degrade the performance of postselected weak measurement, especially when the readout error probability is comparable to the postselection probability. We show that entanglement can significantly reduce the two main detrimental effects of readout errors: inaccuracy in the measurement result and the loss of Fisher information. We extend the protocol by introducing a majority vote scheme to postselection to further compensate for readout errors. With a proper threshold, almost no Fisher information will be lost. These results demonstrate the effectiveness of entanglement in protecting postselected weak measurement against readout errors.