Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2003.02766 · Optics Express

Transportable interrogation laser system with an instability of mod σy = 3 × 10−16

Sebastian Häfner, Sofia Herbers, Stefan Vogt, Christian Lisdat, Uwe Sterr

Published Apr 24, 2020• 39 citations
arXivHTMLPDF

Abstract

We present an interrogation laser system for a transportable strontium lattice clock operating at 698 nm, which is based on an ultra-low-expansion glass reference cavity. Transportability is achieved by implementing a rigid, compact, and vibration insensitive mounting of the 12 cm-long reference cavity, sustaining shocks of up to 50 g. The cavity is mounted at optimized support points that independently constrain all degrees of freedom. This mounting concept is especially beneficial for cavities with a ratio of length L over diameter D L/D > 1. Generally, large L helps to reduce thermal noise-induced laser frequency instability while small D leads to small cavity volume. The frequency instability was evaluated, reaching its thermal noise floor of mod σy ≈ 3 × 10−16 for averaging times between 0.5 s and 10 s. The laser system was successfully operated during several field studies.

DOI
10.1364/oe.390105

Related papers

Ultra-stable clock laser system development towards space applications

Dariusz Świerad, Sebastian Häfner, Stefan Vogt +12 more

Abstract The increasing performance of optical lattice clocks has made them attractive for scientific applications in space and thus has pushed the development of their components including the interrogation lasers of the clock transitions towards being suitable for space, which amongst others requires making them more power efficient, radiation hardened, smaller, lighter as well as more mechanically stable. Here we present the development towards a space-compatible interrogation laser system for a strontium lattice clock constructed within the Space Optical Clock (SOC2) project where we have concentrated on mechanical rigidity and size. The laser reaches a fractional frequency instability of 7.9 × 10 −16 at 300 ms averaging time. The laser system uses a single extended cavity diode laser that gives enough power for interrogating the atoms, frequency comparison by a frequency comb and diagnostics. It includes fibre link stabilisation to the atomic package and to the comb. The optics module containing the laser has dimensions 60 × 45 × 8 cm 3 ; and the ultra-stable reference cavity used for frequency stabilisation with its vacuum system takes 30 × 30 × 30 cm 3 . The acceleration sensitivities in three orthogonal directions of the cavity are 3.6 × 10 −10 /g, 5.8 × 10 −10 /g and 3.1 × 10 −10 /g, where g ≈ 9.8 m/s 2 is the standard gravitational acceleration.

Scientific Reports•Sep 26, 2016•70 citations

Prospects for frequency stabilization using collective effects of strontium atoms in an optical cavity

Bjarke T. R. Christensen, Martin R. Henriksen, Philip G. Westergaard +2 more

The stability of current state-of-the-art optical atomic clocks [1]-[5] is mostly limited by the frequency noise of the interrogation oscillator through the Dick effect. To achieve the heralded ultimate stability, future optical frequency standards will need to produce light sources with frequency stability at the 10−17fractional level or below at one second of integration time. Recently, a new frontier in cavity stabilized laser sources has pushed the fractional instability to the lower 10−16level at one second of integration time [6]-[8]. However, this instability is limited by thermal noise in the reference cavity elements and may be difficult to reduce further. These state-of-the-art reference cavities are technically challenging to construct and their stability is still at least an order of magnitude too large for lattice clocks to achieve their ultimate performance.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2014•0 citations

Transportable cavity-stabilized laser system for optical carrier frequency transmission experiments

B. Parker, Giuseppe Marra, L. A. M. Johnson +6 more

We report the design and performance of a transportable laser system at 1543 nm, together with its application as the source for a demonstration of optical carrier frequency transmission over 118 km of an installed dark fiber network. The laser system is based around an optical reference cavity featuring an elastic mounting that bonds the cavity to its support, enabling the cavity to be transported without additional clamping. The cavity exhibits passive fractional frequency insensitivity to vibration along the optical axis of 2.0×10(-11) m(-1) s(2). With active fiber noise cancellation, the optical carrier frequency transmission achieves a fractional frequency instability, measured at the user end, of 2.6×10(-16) at 1 s, averaging down to below 3×10(-18) after 20,000 s. The fractional frequency accuracy of the transfer is better than 3×10(-18). This level of performance is sufficient for comparison of state-of-the-art optical frequency standards and is achieved in an urban fiber environment.

Applied Optics•Nov 26, 2014•11 citations

Transportable and Ultra-Stable Laser System for 133Cs Rydberg Excitation

Zhongxiao Xu, Changtao Zhao, Donghao Li

Recent progress in Rydberg atoms has enabled a wide range of applications in quantum sensing and quantum computation. In these applications, ultra-stable optical reference systems are essential to meet the requirements of a narrow linewidth and low technical noise. However, most existing systems are confined to laboratory settings and are not suitable for measurement-site-independent applications, such as external electric field sensors. This paper presents a transportable ultra-stable optical reference system for Rydberg excitation. The system is based on a 10 cm long ultra-low-expansion glass optical cavity, and it achieves finesse values of 410 k (at 1018 nm) and 200 k (at 852 nm). After being assembled in the experimental environment, it can still operate with only minor adjustments even after being transported over 400 km. Thanks to its vibration-insensitive design, two-stage temperature control, and hybrid locking unit, the system can maintain its locking status for up to 2 h.

Photonics•Jun 3, 2025•0 citations

Noise and instability of an optical lattice clock

Ali Al-Masoudi, Sören Dörscher, Sebastian Häfner +2 more

We present an analysis of the different types of noise from the detection and interrogation laser in our strontium lattice clock. We develop a noise model showing that in our setup quantum projection noise-limited detection is possible if more than 130 atoms are interrogated. Adding information about the noise spectrum of our clock laser with sub-${10}^{\ensuremath{-}16}$ fractional frequency instability allows one to infer the clock stability for different modes of operation. Excellent agreement with experimental observations for the instability of the difference between two interleaved stabilizations is found. We infer a clock instability of $1.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}/\sqrt{\ensuremath{\tau}}$ as a function of averaging time $\ensuremath{\tau}$ expressed in seconds for normal clock operation.

arXiv:1507.04949•Physical Review A•Dec 8, 2015•84 citations

Advanced laser frequency stabilisation systems for mobile strontium optical lattice clocks

S. Viswam

Strontium optical lattice clocks have undergone vast developments in the past decade with world leading frequency stability and uncertainty records. Now, a lot of scientists are moving from laboratory based clocks to transportable, and portable clocks for applications including space, fundamental science, finance, and communication. The research team at the University of Birmingham are working towards developing transportable apparatus for studying fundamental physics, global positioning system (GPS), and geodesy applications. This thesis reports on the progress towards two different transportable strontium optical lattice clocks, which we will call ‘miniclock’ and ‘Space Optical lattice Clock 2’ (SOC2). \nA diode-seeded tapered amplifier based narrow linewidth laser is developed and used to realise second stage cooling of strontium in miniclock apparatus. The laser has achieved a linewidth of 1 kHz after stabilising to a 3 cm long optical reference cavity. A multiple frequency stabilisation unit (FSU) for strontium lattice clocks is established. It is a robust, portable, and compact frequency stabilisation unit with a volume of 593 cm^3. Three different lasers are currently locked simultaneously to the FSU cavity, which could be extended to any number of lasers, enabling to use a single cavity for locking all the lasers required in a strontium lattice clock, except the clock laser. FSU is designed specifically for use in compact clocks. In the SOC2 system, realisation of clock transition and its characterisation are performed. A transition linewidth of 3 Hz is obtained for the SOC2 strontium clock. Further details and results are described in the thesis.

•Jul 13, 2020•2 citations
We present an interrogation laser system for a transportable strontium lattice clock operating at 698 nm, which is based on an ultra-low-expansion glass reference cavity. Transportability is achieved by implementing a rigid, compact, and vibration insensitive mounting of the 12 cm-long reference cavity, sustaining shocks of up to 50 g. The cavity is mounted at optimized support points that independently constrain all degrees of freedom. This mounting concept is especially beneficial for cavities with a ratio of length L over diameter D L/D > 1. Generally, large L helps to reduce thermal noise-induced laser frequency instability while small D leads to small cavity volume. The frequency instability was evaluated, reaching its thermal noise floor of mod σy ≈ 3 × 10−16 for averaging times between 0.5 s and 10 s. The laser system was successfully operated during several field studies.
Abstract The increasing performance of optical lattice clocks has made them attractive for scientific applications in space and thus has pushed the development of their components including the interrogation lasers of the clock transitions towards being suitable for space, which amongst others requires making them more power efficient, radiation hardened, smaller, lighter as well as more mechanically stable. Here we present the development towards a space-compatible interrogation laser system for a strontium lattice clock constructed within the Space Optical Clock (SOC2) project where we have concentrated on mechanical rigidity and size. The laser reaches a fractional frequency instability of 7.9 × 10 −16 at 300 ms averaging time. The laser system uses a single extended cavity diode laser that gives enough power for interrogating the atoms, frequency comparison by a frequency comb and diagnostics. It includes fibre link stabilisation to the atomic package and to the comb. The optics module containing the laser has dimensions 60 × 45 × 8 cm 3 ; and the ultra-stable reference cavity used for frequency stabilisation with its vacuum system takes 30 × 30 × 30 cm 3 . The acceleration sensitivities in three orthogonal directions of the cavity are 3.6 × 10 −10 /g, 5.8 × 10 −10 /g and 3.1 × 10 −10 /g, where g ≈ 9.8 m/s 2 is the standard gravitational acceleration.
The stability of current state-of-the-art optical atomic clocks [1]-[5] is mostly limited by the frequency noise of the interrogation oscillator through the Dick effect. To achieve the heralded ultimate stability, future optical frequency standards will need to produce light sources with frequency stability at the 10−17fractional level or below at one second of integration time. Recently, a new frontier in cavity stabilized laser sources has pushed the fractional instability to the lower 10−16level at one second of integration time [6]-[8]. However, this instability is limited by thermal noise in the reference cavity elements and may be difficult to reduce further. These state-of-the-art reference cavities are technically challenging to construct and their stability is still at least an order of magnitude too large for lattice clocks to achieve their ultimate performance.
We report the design and performance of a transportable laser system at 1543 nm, together with its application as the source for a demonstration of optical carrier frequency transmission over 118 km of an installed dark fiber network. The laser system is based around an optical reference cavity featuring an elastic mounting that bonds the cavity to its support, enabling the cavity to be transported without additional clamping. The cavity exhibits passive fractional frequency insensitivity to vibration along the optical axis of 2.0×10(-11) m(-1) s(2). With active fiber noise cancellation, the optical carrier frequency transmission achieves a fractional frequency instability, measured at the user end, of 2.6×10(-16) at 1 s, averaging down to below 3×10(-18) after 20,000 s. The fractional frequency accuracy of the transfer is better than 3×10(-18). This level of performance is sufficient for comparison of state-of-the-art optical frequency standards and is achieved in an urban fiber environment.
Recent progress in Rydberg atoms has enabled a wide range of applications in quantum sensing and quantum computation. In these applications, ultra-stable optical reference systems are essential to meet the requirements of a narrow linewidth and low technical noise. However, most existing systems are confined to laboratory settings and are not suitable for measurement-site-independent applications, such as external electric field sensors. This paper presents a transportable ultra-stable optical reference system for Rydberg excitation. The system is based on a 10 cm long ultra-low-expansion glass optical cavity, and it achieves finesse values of 410 k (at 1018 nm) and 200 k (at 852 nm). After being assembled in the experimental environment, it can still operate with only minor adjustments even after being transported over 400 km. Thanks to its vibration-insensitive design, two-stage temperature control, and hybrid locking unit, the system can maintain its locking status for up to 2 h.
We present an analysis of the different types of noise from the detection and interrogation laser in our strontium lattice clock. We develop a noise model showing that in our setup quantum projection noise-limited detection is possible if more than 130 atoms are interrogated. Adding information about the noise spectrum of our clock laser with sub-${10}^{\ensuremath{-}16}$ fractional frequency instability allows one to infer the clock stability for different modes of operation. Excellent agreement with experimental observations for the instability of the difference between two interleaved stabilizations is found. We infer a clock instability of $1.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}/\sqrt{\ensuremath{\tau}}$ as a function of averaging time $\ensuremath{\tau}$ expressed in seconds for normal clock operation.
Strontium optical lattice clocks have undergone vast developments in the past decade with world leading frequency stability and uncertainty records. Now, a lot of scientists are moving from laboratory based clocks to transportable, and portable clocks for applications including space, fundamental science, finance, and communication. The research team at the University of Birmingham are working towards developing transportable apparatus for studying fundamental physics, global positioning system (GPS), and geodesy applications. This thesis reports on the progress towards two different transportable strontium optical lattice clocks, which we will call ‘miniclock’ and ‘Space Optical lattice Clock 2’ (SOC2). \nA diode-seeded tapered amplifier based narrow linewidth laser is developed and used to realise second stage cooling of strontium in miniclock apparatus. The laser has achieved a linewidth of 1 kHz after stabilising to a 3 cm long optical reference cavity. A multiple frequency stabilisation unit (FSU) for strontium lattice clocks is established. It is a robust, portable, and compact frequency stabilisation unit with a volume of 593 cm^3. Three different lasers are currently locked simultaneously to the FSU cavity, which could be extended to any number of lasers, enabling to use a single cavity for locking all the lasers required in a strontium lattice clock, except the clock laser. FSU is designed specifically for use in compact clocks. In the SOC2 system, realisation of clock transition and its characterisation are performed. A transition linewidth of 3 Hz is obtained for the SOC2 strontium clock. Further details and results are described in the thesis.