Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1507.04949 · Physical Review A

Noise and instability of an optical lattice clock

Ali Al-Masoudi, Sören Dörscher, Sebastian Häfner, Uwe Sterr, Christian Lisdat

Published Dec 8, 2015• 84 citations
arXivHTMLPDF

Abstract

We present an analysis of the different types of noise from the detection and interrogation laser in our strontium lattice clock. We develop a noise model showing that in our setup quantum projection noise-limited detection is possible if more than 130 atoms are interrogated. Adding information about the noise spectrum of our clock laser with sub-${10}^{\ensuremath{-}16}$ fractional frequency instability allows one to infer the clock stability for different modes of operation. Excellent agreement with experimental observations for the instability of the difference between two interleaved stabilizations is found. We infer a clock instability of $1.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}/\sqrt{\ensuremath{\tau}}$ as a function of averaging time $\ensuremath{\tau}$ expressed in seconds for normal clock operation.

DOI
10.1103/physreva.92.063814

Related papers

Frequency comparison of optical lattice clocks

Masao Takamoto, T. Takano, Hidetoshi Katori

We demonstrate the frequency comparison of two optical lattice clocks at the relative stabilities close to the quantum projection noise (QPN) limit of optical lattice clocks. This stable frequency comparison is accomplished by synchronous interrogations of two clocks by a common probe laser, which allows us to cancel out the probe laser's frequency noise. We perform the frequency comparison of a one-dimensional (1D) optical lattice clock with spin-polarized fermions 87Sr and a three-dimensional (3D) optical lattice clock with unity-occupation bosons 88Sr and achieve the Allan standard deviation of σγ(τ)=4×10-16 τ-1/2, which corresponds to the QPN limited stability for N=1,000 atoms and the spectrum linewidth γ=8 Hz. The relative stability reaches 1×10-17 with an averaging time of 1,600 s. Finally, we discuss the prospects to realize 10-18 fractional inaccuracies and the possible application of frequency comparison with synchronous interrogations to remote clocks' comparison for relativistic geodesy.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 8, 2011•0 citations

Comparison of Two Independent Sr Optical Clocks with 1 × 10 − 17 Stability at 10 3 s

Travis Nicholson, Michael J. Martin, Jason Williams +5 more

Many-particle optical lattice clocks have the potential for unprecedented measurement precision and stability due to their low quantum projection noise. However, this potential has so far never been realized because clock stability has been limited by frequency noise of optical local oscillators. By synchronously probing two $^{87}\mathrm{Sr}$ lattice systems using a laser with a thermal noise floor of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$, we remove classically correlated laser noise from the intercomparison, but this does not demonstrate independent clock performance. With an improved optical oscillator that has a $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$ thermal noise floor, we demonstrate an order of magnitude improvement over the best reported stability of any independent clock, achieving a fractional instability of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ in 1000 s of averaging time for synchronous or asynchronous comparisons. This result is within a factor of 2 of the combined quantum projection noise limit for a 160 ms probe time with $\ensuremath{\sim}{10}^{3}$ atoms in each clock. We further demonstrate that even at this high precision, the overall systematic uncertainty of our clock is not limited by atomic interactions. For the second Sr clock, which has a cavity-enhanced lattice, the atomic-density-dependent frequency shift is evaluated to be $\ensuremath{-}3.11\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ with an uncertainty of $8.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$.

arXiv:1210.0064•Physical Review Letters•Dec 5, 2012•206 citations

Zero-Dead-Time Strontium Lattice Clock with a Stability at 10 − 19 Level

Xiao-Yong Liu, Peng Liu, Jie Li +20 more

Optical atomic clocks play a crucial role in fundamental physics, relativistic geodesy, and the future redefinition of the Systeme International second. Standard operation relies on cyclic interrogation sequences, which alternate between atomic interrogation and dead time used for state preparation and readout. This approach introduces the Dick effect, where laser frequency noise aliases onto the atomic transition frequency. Although reducing laser noise improves clock stability, the Dick effect remains a key limitation. In this Letter, we demonstrate a zero-dead-time optical clock based on two interleaved ensembles of cold ^{87}Sr atoms. Our system significantly suppresses this noise and achieves a fractional frequency instability at the 10^{-19} level between 10 000 and 20 000 s over repeated measurements, with a best value of 2.9×10^{-19} at τ=20000 s. The estimated long-term stability based on the combined data of these measurements reaches 2.5×10^{-19} at 1 day. These results represent a more than ninefold improvement over a conventional single-ensemble clock, highlighting its potential for next-generation timekeeping applications.

arXiv:2509.15100•Physical Review Letters•Nov 26, 2025•15 citations

Prospects for frequency stabilization using collective effects of strontium atoms in an optical cavity

Bjarke T. R. Christensen, Martin R. Henriksen, Philip G. Westergaard +2 more

The stability of current state-of-the-art optical atomic clocks [1]-[5] is mostly limited by the frequency noise of the interrogation oscillator through the Dick effect. To achieve the heralded ultimate stability, future optical frequency standards will need to produce light sources with frequency stability at the 10−17fractional level or below at one second of integration time. Recently, a new frontier in cavity stabilized laser sources has pushed the fractional instability to the lower 10−16level at one second of integration time [6]-[8]. However, this instability is limited by thermal noise in the reference cavity elements and may be difficult to reduce further. These state-of-the-art reference cavities are technically challenging to construct and their stability is still at least an order of magnitude too large for lattice clocks to achieve their ultimate performance.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2014•0 citations

Frequency noise processes in a strontium ion optical clock

G. P. Barwood, Guozheng Huang, S. A. King +2 more

Abstract A recent comparison of the frequencies of a pair of optical clocks based on the 674 nm 2 S 1/2 – 2 D 5/2 optical clock transition in 88 Sr + has highlighted the need to understand factors affecting frequency instability. We have developed statistical models to show that our clock is capable of reaching the quantum projection noise limit; for our clock using 100 ms probe pulses, this is ∼3 × 10 −15 /√ τ . However, this optical clock uses atomic transitions with a linear Zeeman shift, which can lead to a degradation in stability in the presence of magnetic field noise. We show that this generally leads to an increase in white frequency noise, even in cases dominated by magnetic field flicker or random walk noise. By taking into account both the quantum projection and magnetic field noise we are able to explain our observed frequency instabilities. This analysis will relate to any optical clock with a linear Zeeman shift where cancellation of this shift is achieved by interrogating pairs of components. Furthermore, implementing automatic control of lasers and minimization of micromotion requires pausing of the frequency servo occasionally; this leads to only a small degradation of frequency stability.

Journal of Physics B Atomic Molecular and Optical Physics•Jan 13, 2015•14 citations

Quantum Nondemolition Detection for Strontium Optical Lattice Clock

Haosen Shang, Miguel A. Cifuentes Marin, Yannick Foucault +2 more

SummaryThe short-term frequency instability of the best optical atomic clock lies in the mid 10−17. However, the Dick effect is still an obstacle for a single operational clock closely followed by the quantum projection noise. To improve the frequency stability of the strontium optical lattice clock, we present a quantum non-demolition detection scheme based on the cavity mediated interaction between the atoms and a probe light that has a large-frequency detuning to the atomic resonance, aiming to bring the detection scheme proposed in [1] to the quantum regime. We obtained a rather small photon scattering rate, measured to be less than 0.1 photon/μs/atom, which allows us to not only preserve the atoms in the lattice but also the atomic wave function as long as the total probe time is on the order of a few microseconds. The detection noise for the number of atoms is 48/√photons atoms, implying that the frequency stability can surpass the standard quantum limit when the number of trapped atoms is larger than 2.3×104with spin squeezing protocols.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 24, 2022•1 citation
We present an analysis of the different types of noise from the detection and interrogation laser in our strontium lattice clock. We develop a noise model showing that in our setup quantum projection noise-limited detection is possible if more than 130 atoms are interrogated. Adding information about the noise spectrum of our clock laser with sub-10\ensuremath−16{10}^{\ensuremath{-}16}10\ensuremath−16 fractional frequency instability allows one to infer the clock stability for different modes of operation. Excellent agreement with experimental observations for the instability of the difference between two interleaved stabilizations is found. We infer a clock instability of 1.6\ifmmode×\else\texttimes\fi10\ensuremath−16/\ensuremathτ1.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}/\sqrt{\ensuremath{\tau}}1.6\ifmmode×\else\texttimes\fi10\ensuremath−16/\ensuremathτ​ as a function of averaging time \ensuremathτ\ensuremath{\tau}\ensuremathτ expressed in seconds for normal clock operation.
We demonstrate the frequency comparison of two optical lattice clocks at the relative stabilities close to the quantum projection noise (QPN) limit of optical lattice clocks. This stable frequency comparison is accomplished by synchronous interrogations of two clocks by a common probe laser, which allows us to cancel out the probe laser's frequency noise. We perform the frequency comparison of a one-dimensional (1D) optical lattice clock with spin-polarized fermions 87Sr and a three-dimensional (3D) optical lattice clock with unity-occupation bosons 88Sr and achieve the Allan standard deviation of σγ(τ)=4×10-16 τ-1/2, which corresponds to the QPN limited stability for N=1,000 atoms and the spectrum linewidth γ=8 Hz. The relative stability reaches 1×10-17 with an averaging time of 1,600 s. Finally, we discuss the prospects to realize 10-18 fractional inaccuracies and the possible application of frequency comparison with synchronous interrogations to remote clocks' comparison for relativistic geodesy.
Many-particle optical lattice clocks have the potential for unprecedented measurement precision and stability due to their low quantum projection noise. However, this potential has so far never been realized because clock stability has been limited by frequency noise of optical local oscillators. By synchronously probing two 87Sr^{87}\mathrm{Sr}87Sr lattice systems using a laser with a thermal noise floor of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$, we remove classically correlated laser noise from the intercomparison, but this does not demonstrate independent clock performance. With an improved optical oscillator that has a $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$ thermal noise floor, we demonstrate an order of magnitude improvement over the best reported stability of any independent clock, achieving a fractional instability of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ in 1000 s of averaging time for synchronous or asynchronous comparisons. This result is within a factor of 2 of the combined quantum projection noise limit for a 160 ms probe time with $\ensuremath{\sim}{10}^{3}$ atoms in each clock. We further demonstrate that even at this high precision, the overall systematic uncertainty of our clock is not limited by atomic interactions. For the second Sr clock, which has a cavity-enhanced lattice, the atomic-density-dependent frequency shift is evaluated to be $\ensuremath{-}3.11\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ with an uncertainty of $8.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$.
Optical atomic clocks play a crucial role in fundamental physics, relativistic geodesy, and the future redefinition of the Systeme International second. Standard operation relies on cyclic interrogation sequences, which alternate between atomic interrogation and dead time used for state preparation and readout. This approach introduces the Dick effect, where laser frequency noise aliases onto the atomic transition frequency. Although reducing laser noise improves clock stability, the Dick effect remains a key limitation. In this Letter, we demonstrate a zero-dead-time optical clock based on two interleaved ensembles of cold ^{87}Sr atoms. Our system significantly suppresses this noise and achieves a fractional frequency instability at the 10^{-19} level between 10 000 and 20 000 s over repeated measurements, with a best value of 2.9×10^{-19} at τ=20000 s. The estimated long-term stability based on the combined data of these measurements reaches 2.5×10^{-19} at 1 day. These results represent a more than ninefold improvement over a conventional single-ensemble clock, highlighting its potential for next-generation timekeeping applications.
The stability of current state-of-the-art optical atomic clocks [1]-[5] is mostly limited by the frequency noise of the interrogation oscillator through the Dick effect. To achieve the heralded ultimate stability, future optical frequency standards will need to produce light sources with frequency stability at the 10−17fractional level or below at one second of integration time. Recently, a new frontier in cavity stabilized laser sources has pushed the fractional instability to the lower 10−16level at one second of integration time [6]-[8]. However, this instability is limited by thermal noise in the reference cavity elements and may be difficult to reduce further. These state-of-the-art reference cavities are technically challenging to construct and their stability is still at least an order of magnitude too large for lattice clocks to achieve their ultimate performance.
Abstract A recent comparison of the frequencies of a pair of optical clocks based on the 674 nm 2 S 1/2 – 2 D 5/2 optical clock transition in 88 Sr + has highlighted the need to understand factors affecting frequency instability. We have developed statistical models to show that our clock is capable of reaching the quantum projection noise limit; for our clock using 100 ms probe pulses, this is ∼3 × 10 −15 /√ τ . However, this optical clock uses atomic transitions with a linear Zeeman shift, which can lead to a degradation in stability in the presence of magnetic field noise. We show that this generally leads to an increase in white frequency noise, even in cases dominated by magnetic field flicker or random walk noise. By taking into account both the quantum projection and magnetic field noise we are able to explain our observed frequency instabilities. This analysis will relate to any optical clock with a linear Zeeman shift where cancellation of this shift is achieved by interrogating pairs of components. Furthermore, implementing automatic control of lasers and minimization of micromotion requires pausing of the frequency servo occasionally; this leads to only a small degradation of frequency stability.
SummaryThe short-term frequency instability of the best optical atomic clock lies in the mid 10−17. However, the Dick effect is still an obstacle for a single operational clock closely followed by the quantum projection noise. To improve the frequency stability of the strontium optical lattice clock, we present a quantum non-demolition detection scheme based on the cavity mediated interaction between the atoms and a probe light that has a large-frequency detuning to the atomic resonance, aiming to bring the detection scheme proposed in [1] to the quantum regime. We obtained a rather small photon scattering rate, measured to be less than 0.1 photon/μs/atom, which allows us to not only preserve the atoms in the lattice but also the atomic wave function as long as the total probe time is on the order of a few microseconds. The detection noise for the number of atoms is 48/√photons atoms, implying that the frequency stability can surpass the standard quantum limit when the number of trapped atoms is larger than 2.3×104with spin squeezing protocols.