Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1910.05459 · Physical Review Letters

Large Momentum Transfer Clock Atom Interferometry on the 689 nm Intercombination Line of Strontium

Jan Rudolph, Thomas F. Wilkason, Megan K. T. Nantel, Hunter Swan, Connor M. Holland, Yijun Jiang, Benjamin E. Garber, Samuel P. Carman, Jason M. Hogan

Published Feb 28, 2020• 126 citations
arXivHTMLPDF

Abstract

We report the first realization of large momentum transfer (LMT) clock atom interferometry. Using single-photon interactions on the strontium ^{1}S_{0}-^{3}P_{1} transition, we demonstrate Mach-Zehnder interferometers with state-of-the-art momentum separation of up to 141 ℏk and gradiometers of up to 81 ℏk. Moreover, we circumvent excited state decay limitations and extend the gradiometer duration to 50 times the excited state lifetime. Because of the broad velocity acceptance of the interferometry pulses, all experiments are performed with laser-cooled atoms at a temperature of 3 μK. This work has applications in high-precision inertial sensing and paves the way for LMT-enhanced clock atom interferometry on even narrower transitions, a key ingredient in proposals for gravitational wave detection and dark matter searches.

DOI
10.1103/physrevlett.124.083604

Related papers

Enhancing strontium clock atom interferometry using quantum optimal control

Zilin Chen, Garrett Louie, Yiping Wang +2 more

Strontium clock atom interferometry is a promising new technology, with multiple experiments under development around the world to explore its potential for dark matter and gravitational wave detection. In these detectors, large momentum transfer using sequences of many laser pulses is necessary, and thus high-fidelity pulses are important since small errors become magnified. Quantum optimal control (QOC) is a framework for developing control pulse waveforms that achieve high fidelity and are robust against experimental imperfections. Resonant single-photon transitions using the narrow clock transition of strontium involve significantly different quantum dynamics than more established atom interferometry methods based on far-detuned two-photon Raman or Bragg transitions, which leads to new opportunities and challenges when applying QOC. Here, we study in simulation QOC pulses for strontium clock interferometry and demonstrate their advantage over basic square pulses (primitive pulses) and composite pulses in terms of robustness against multiple noise channels. This could improve the scale of large momentum transfer in Sr clock interferometers, paving the way to achieving these scientific goals.

arXiv:2207.13217•Physical Review A•Jun 8, 2023•17 citations

Atom Interferometry with the Sr Optical Clock Transition

Liang Hu, N. Poli, Leonardo Salvi +1 more

We report on the realization of a matter-wave interferometer based on single-photon interaction on the ultranarrow optical clock transition of strontium atoms. We experimentally demonstrate its operation as a gravimeter and as a gravity gradiometer. No reduction of interferometric contrast was observed for a total interferometer time up to ∼10 ms, limited by geometric constraints of the apparatus. Single-photon interferometers represent a new class of high-precision sensors that could be used for the detection of gravitational waves in so far unexplored frequency ranges and to enlighten the boundary between quantum mechanics and general relativity.

arXiv:1708.05116•Physical Review Letters•Dec 27, 2017•146 citations

Circulating pulse cavity enhancement as a method for extreme momentum transfer atom interferometry

Rustin Nourshargh, Samuel Lellouch, Sam Hedges +3 more

Abstract Large-scale atom interferometers promise unrivaled strain sensitivity to mid-band gravitational waves, and will probe a new parameter space in the search for ultra-light scalar dark matter. These proposals require gradiometry with kilometer-scale baselines, a momentum separation above 104ℏk between interferometer arms, and optical transitions to long-lived clock states to reach the target sensitivities. Prohibitively high optical power and wavefront flatness requirements have thus far limited the maximum achievable momentum splitting. Here we propose a scheme for optical cavity enhanced atom interferometry, using circulating, spatially resolved pulses, and intracavity frequency modulation to meet these requirements. We present parameters for the realization of 20 kW circulating pulses in a 1 km interferometer enabling 104ℏk splitting on the 698 nm clock transition in 87Sr. This scheme addresses the presently insurmountable laser power requirements and is feasible in the context of a kilometer-scale atom interferometer facility.

arXiv:2012.06426•Communications Physics•Dec 2, 2021•21 citations

Dual atomic interferometry for differential inertial sensing

Jianing Li

The utilization of light-pulse atom interferometry presents a valuable technique that has found application in both fundamental scientific inquiries, such as investigating constants such as measurements of fine structure constant α and gravitational constant G, and practical endeavors including acceleration sensing and rotation measurements. This thesis delves into our implementation of a dual atom interferometer design involving the clock transition 1S0 → 3P0 in strontium, concurrently conducting the interferometric sequence on atoms in both ground and excited states. To facilitate the dual atom interferometer’s operation, we have firstly established a compact experimental setup with a transversely loaded bi-dimensional magneto-optical-trap (2D-MOT) to create a high flux source of cold strontium atoms. Introducing a novel cross-polarized bi-color atomic beam slower, we simultaneously addresses two excited Zeeman substates of the transition 1S0 → 1P1 in strontium-88, significantly enhancing the number of atoms prepared in the 461 nm MOT by around 10-fold. Following the 461 nm MOT, the atomic ensemble undergoes cooling in a 689 nm MOT, achieving atomic temperatures below 1 µK. We also install a network of eight magnetic field probes arranged around the cold atomic sample, enabling precise three-axis active control of magnetic fields down to the milligauss level. With the atoms confined in a 2D lattice at the magic-wavelength of 813.427 nm after the initial preparation phase, we conduct the magnetically-induced clock transition to create a statistical mixture state of ground and excited states. After a velocity selection stage, implementing a Mach-Zehnder interferometer with Bragg pulses operating at the magic-wavelength along the vertical axis, we conduct tests of the weak equivalence principle (WEP). The Eötvös ratio we found in our system stood at (1.8 ± 3.1) × 10−4, mainly limited by the finite temperature of the atomic cloud constraining the interrogation time. Furthermore, the dual atom interferometer scheme enables the measurement of state-dependent force and eventually polarizability difference via the phase shift between the atoms in different states, and we experimentally demonstrate this by introducing an additional light field gradient.

•Jan 1, 2023•0 citations

A large-momentum-transfer matter-wave interferometer to measure the effect of gravity on positronium

G. Vinelli, F. Castelli, R. Ferragut +7 more

Abstract This paper reports the study of a new interferometric configuration to measure the effect of gravity on positronium. A Mach–Zehnder matter-wave interferometer has been designed to operate with single-photon transitions and to transfer high momentum to a 200 eV positronium beam. The work shows the results and methods used to simulate the interferometer and estimate the operating parameters and the time needed to perform the experiment. It has been estimated that within less than 1 year, the acquisition time is sufficient to achieve a 10% accuracy level in measuring positronium gravitational acceleration, even with a poorly collimated beam, which is significant for theoretical models describing matter–antimatter symmetry. These results pave the way for single photon transition large momentum transfer interferometry with fast atomic beams, which is particularly useful for studies with antimatter and unstable atoms.

arXiv:2303.11798•Classical and Quantum Gravity•Sep 11, 2023•11 citations

Cumulative fidelity of large-momentum-transfer clock atom interferometers in the presence of laser noise

Yijun Jiang, Jan Rudolph, Jason M. Hogan

Clock atom interferometry is an emerging technique in precision measurements that is particularly well suited for sensitivity enhancement through large momentum transfer (LMT). While current systems have demonstrated momentum separations of several hundreds of photon momenta, next-generation quantum sensors are targeting an LMT enhancement factor beyond $10^4$. However, the viability of LMT clock interferometers has recently come into question due to the potential impact of laser frequency noise. Here, we resolve this concern by analyzing the cumulative fidelity of sequential state inversions in an LMT atom interferometer. We show that the population error from $n$ pulses applied from alternating directions scales linearly with $n$. This is a significant advantage over the $n^2$ scaling that occurs when probing a two-level system $n$ times from the same direction. We further show that contributions to the interferometer signal from parasitic paths generated by imperfect pulses are negligible, for any loss mechanism. These results establish that laser frequency noise is not a practical limitation for the development of high-fidelity LMT clock atom interferometers.

arXiv:2508.10288•Physical Review A•Mar 9, 2026•1 citation
We report the first realization of large momentum transfer (LMT) clock atom interferometry. Using single-photon interactions on the strontium ^{1}S_{0}-^{3}P_{1} transition, we demonstrate Mach-Zehnder interferometers with state-of-the-art momentum separation of up to 141 ℏk and gradiometers of up to 81 ℏk. Moreover, we circumvent excited state decay limitations and extend the gradiometer duration to 50 times the excited state lifetime. Because of the broad velocity acceptance of the interferometry pulses, all experiments are performed with laser-cooled atoms at a temperature of 3 μK. This work has applications in high-precision inertial sensing and paves the way for LMT-enhanced clock atom interferometry on even narrower transitions, a key ingredient in proposals for gravitational wave detection and dark matter searches.
Strontium clock atom interferometry is a promising new technology, with multiple experiments under development around the world to explore its potential for dark matter and gravitational wave detection. In these detectors, large momentum transfer using sequences of many laser pulses is necessary, and thus high-fidelity pulses are important since small errors become magnified. Quantum optimal control (QOC) is a framework for developing control pulse waveforms that achieve high fidelity and are robust against experimental imperfections. Resonant single-photon transitions using the narrow clock transition of strontium involve significantly different quantum dynamics than more established atom interferometry methods based on far-detuned two-photon Raman or Bragg transitions, which leads to new opportunities and challenges when applying QOC. Here, we study in simulation QOC pulses for strontium clock interferometry and demonstrate their advantage over basic square pulses (primitive pulses) and composite pulses in terms of robustness against multiple noise channels. This could improve the scale of large momentum transfer in Sr clock interferometers, paving the way to achieving these scientific goals.
We report on the realization of a matter-wave interferometer based on single-photon interaction on the ultranarrow optical clock transition of strontium atoms. We experimentally demonstrate its operation as a gravimeter and as a gravity gradiometer. No reduction of interferometric contrast was observed for a total interferometer time up to ∼10 ms, limited by geometric constraints of the apparatus. Single-photon interferometers represent a new class of high-precision sensors that could be used for the detection of gravitational waves in so far unexplored frequency ranges and to enlighten the boundary between quantum mechanics and general relativity.
Abstract Large-scale atom interferometers promise unrivaled strain sensitivity to mid-band gravitational waves, and will probe a new parameter space in the search for ultra-light scalar dark matter. These proposals require gradiometry with kilometer-scale baselines, a momentum separation above 104ℏk between interferometer arms, and optical transitions to long-lived clock states to reach the target sensitivities. Prohibitively high optical power and wavefront flatness requirements have thus far limited the maximum achievable momentum splitting. Here we propose a scheme for optical cavity enhanced atom interferometry, using circulating, spatially resolved pulses, and intracavity frequency modulation to meet these requirements. We present parameters for the realization of 20 kW circulating pulses in a 1 km interferometer enabling 104ℏk splitting on the 698 nm clock transition in 87Sr. This scheme addresses the presently insurmountable laser power requirements and is feasible in the context of a kilometer-scale atom interferometer facility.
The utilization of light-pulse atom interferometry presents a valuable technique that has found application in both fundamental scientific inquiries, such as investigating constants such as measurements of fine structure constant α and gravitational constant G, and practical endeavors including acceleration sensing and rotation measurements. This thesis delves into our implementation of a dual atom interferometer design involving the clock transition 1S0 → 3P0 in strontium, concurrently conducting the interferometric sequence on atoms in both ground and excited states. To facilitate the dual atom interferometer’s operation, we have firstly established a compact experimental setup with a transversely loaded bi-dimensional magneto-optical-trap (2D-MOT) to create a high flux source of cold strontium atoms. Introducing a novel cross-polarized bi-color atomic beam slower, we simultaneously addresses two excited Zeeman substates of the transition 1S0 → 1P1 in strontium-88, significantly enhancing the number of atoms prepared in the 461 nm MOT by around 10-fold. Following the 461 nm MOT, the atomic ensemble undergoes cooling in a 689 nm MOT, achieving atomic temperatures below 1 µK. We also install a network of eight magnetic field probes arranged around the cold atomic sample, enabling precise three-axis active control of magnetic fields down to the milligauss level. With the atoms confined in a 2D lattice at the magic-wavelength of 813.427 nm after the initial preparation phase, we conduct the magnetically-induced clock transition to create a statistical mixture state of ground and excited states. After a velocity selection stage, implementing a Mach-Zehnder interferometer with Bragg pulses operating at the magic-wavelength along the vertical axis, we conduct tests of the weak equivalence principle (WEP). The Eötvös ratio we found in our system stood at (1.8 ± 3.1) × 10−4, mainly limited by the finite temperature of the atomic cloud constraining the interrogation time. Furthermore, the dual atom interferometer scheme enables the measurement of state-dependent force and eventually polarizability difference via the phase shift between the atoms in different states, and we experimentally demonstrate this by introducing an additional light field gradient.
Abstract This paper reports the study of a new interferometric configuration to measure the effect of gravity on positronium. A Mach–Zehnder matter-wave interferometer has been designed to operate with single-photon transitions and to transfer high momentum to a 200 eV positronium beam. The work shows the results and methods used to simulate the interferometer and estimate the operating parameters and the time needed to perform the experiment. It has been estimated that within less than 1 year, the acquisition time is sufficient to achieve a 10% accuracy level in measuring positronium gravitational acceleration, even with a poorly collimated beam, which is significant for theoretical models describing matter–antimatter symmetry. These results pave the way for single photon transition large momentum transfer interferometry with fast atomic beams, which is particularly useful for studies with antimatter and unstable atoms.
Clock atom interferometry is an emerging technique in precision measurements that is particularly well suited for sensitivity enhancement through large momentum transfer (LMT). While current systems have demonstrated momentum separations of several hundreds of photon momenta, next-generation quantum sensors are targeting an LMT enhancement factor beyond 10410^4104. However, the viability of LMT clock interferometers has recently come into question due to the potential impact of laser frequency noise. Here, we resolve this concern by analyzing the cumulative fidelity of sequential state inversions in an LMT atom interferometer. We show that the population error from nnn pulses applied from alternating directions scales linearly with nnn. This is a significant advantage over the n2n^2n2 scaling that occurs when probing a two-level system nnn times from the same direction. We further show that contributions to the interferometer signal from parasitic paths generated by imperfect pulses are negligible, for any loss mechanism. These results establish that laser frequency noise is not a practical limitation for the development of high-fidelity LMT clock atom interferometers.