Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2508.10288 · Physical Review A

Cumulative fidelity of large-momentum-transfer clock atom interferometers in the presence of laser noise

Yijun Jiang, Jan Rudolph, Jason M. Hogan

Published Mar 9, 2026• 1 citation
arXivHTMLPDF

Abstract

Clock atom interferometry is an emerging technique in precision measurements that is particularly well suited for sensitivity enhancement through large momentum transfer (LMT). While current systems have demonstrated momentum separations of several hundreds of photon momenta, next-generation quantum sensors are targeting an LMT enhancement factor beyond $10^4$. However, the viability of LMT clock interferometers has recently come into question due to the potential impact of laser frequency noise. Here, we resolve this concern by analyzing the cumulative fidelity of sequential state inversions in an LMT atom interferometer. We show that the population error from $n$ pulses applied from alternating directions scales linearly with $n$. This is a significant advantage over the $n^2$ scaling that occurs when probing a two-level system $n$ times from the same direction. We further show that contributions to the interferometer signal from parasitic paths generated by imperfect pulses are negligible, for any loss mechanism. These results establish that laser frequency noise is not a practical limitation for the development of high-fidelity LMT clock atom interferometers.

DOI
10.1103/tqrf-42yp

Related papers

Cumulative fidelity of LMT clock atom interferometers in the presence of laser noise

Yijun Jiang, Jason M. Hogan, Jan Rudolph

Clock atom interferometry is an emerging technique in precision measurement, well suited for sensitivity enhancement through large momentum transfer (LMT). Although next-generation sensors aim for LMT factors beyond $10^4$, their feasibility has been questioned due to potential impacts of laser frequency noise. We address this concern by analyzing the cumulative fidelity of sequential state inversions, showing that population error scales linearly with pulse number, not quadratically. Parasitic interferometer paths from imperfect pulses contribute negligibly, confirming that laser frequency noise is not a practical limitation.

Optical and Quantum Sensing and Precision Metrology II•Mar 5, 2026•0 citations

Limitations on maximum achievable enhancement in sensitivity using large momentum transfer for point source atom interferometry

Jinyang Li, Gregório R. M. da Silva, Wayne Huang +4 more

A point source interferometer (PSI) is a device where atoms are split and recombined by applying a temporal sequence of Raman pulses. During the pulse sequence, an initially trapped cloud of cold atoms is released and allowed to expand, behaving approximately as a point source. The PSI can work as a sensitive multi-axes gyroscope that can automatically filter out the signal from accelerations. The phase shift arising from rotations is proportional to the momentum transferred to each atom from the Raman pulses. Therefore, by increasing the momentum transfer, it should be possibly to enhance the sensitivity of the PSI. Here, we investigate the degree of enhancement in sensitivity that could be achieved by augmenting the PSI with large momentum transfer (LMT) employing a sequence of many Raman pulses with alternating directions. Contrary to typical approaches used for describing a PSI, we employ a model under which the motion of the center of mass of each atom is described quantum mechanically. We show how increasing Doppler shifts lead to imperfections, thereby limiting the visibility of the signal fringes, and identify ways to suppress this effect by increasing the effective, two-photon Rabi frequencies of the Raman pulses. Considering the effect of spontaneous emission, we show that for a given value of the one-photon Rabi frequency, there is an optimum value for the number of pulses employed, beyond which the net enhancement in sensitivity begins to decrease. For a one-photon Rabi frequency of 200 MHz, for example, the peak value of the factor of enhancement in sensitivity is ~39, for a momentum transfer that is ~69 times as large as that for a conventional PSI. We also find that this peak value scales as the one-photon Rabi frequency to the power of 4/5.

Optical and Quantum Sensing and Precision Metrology•Mar 4, 2021•0 citations

Counterdiabatic Raman Atom Optics for Compact High-Sensitivity Gravimetry

Asad Ali, Hamid Arian Zad, Saif Al-Kuwari +6 more

Large-momentum-transfer (LMT) atom interferometry provides a route toward enhanced inertial sensitivity in compact quantum sensors, but its scalability is limited by the accumulation of pulse-transfer errors across long Raman pulse sequences. We investigate theoretically the use of stimulated Raman shortcut-to-adiabatic passage (STIRSAP) for high-fidelity LMT atom optics in a Mach--Zehnder interferometer geometry. The counterdiabatic correction is encoded directly into the Raman pulse envelopes, eliminating the need for auxiliary microwave or radio-frequency control fields. Numerical simulations based on an effective Raman model show that $1~μ\mathrm{s}$ STIRSAP pulses achieve single-pulse transfer fidelities of $F_π= 0.99902$ while maintaining negligible pulse-time overhead even at high momentum order. We analyze the resulting tradeoff between interferometric phase enhancement and compound contrast decay and identify an unconstrained shot-noise optimum near $n\approx270$. The analysis further shows that practical operation at extreme LMT order is constrained by wave-packet separation, vibration noise, Doppler detuning, and accumulated systematic effects rather than by pulse duration itself. These results establish superadiabatic Raman control as a promising approach for scalable high-fidelity atom optics and clarify the physical limitations governing compact high-order atom interferometers.

quant-pharXiv:2606.16945•Jun 16, 2026•1 citation

Detection-resolution limits of large-momentum-transfer atom gravimetry

Asad Ali, Saif Al-Kuwari

Large momentum transfer (LMT) enhances the gravitational phase of a light-pulse atom interferometer by a factor $n$, while mirrorless operation with momentum-resolved detection can quadruple the phase-carrying quantum Fisher information. These gains compete in practice because the momentum-space fringe period scales as $1/n$, making the fringe signal increasingly vulnerable to finite detector resolution. We analyze this trade-off in a solvable model with instantaneous lossless $n$-photon pulses, a Gaussian source, and Gaussian detection blur, allowing continuous interpolation between Kasevich--Chu and mirrorless geometries. Closed-form expressions for the blurred output distributions and classical Fisher information are obtained, with a fringe-phase averaging approximation whose error is exponentially suppressed and agrees with numerical simulations at the $10^{-8}$ level. We find that mirrorless operation surpasses a conventional interferometer with the same momentum transfer only when $σ_p < 0.91\,m/(n k_0 T)$. Fringe-based readout exhibits an optimal momentum transfer $n^* \simeq 0.93\,m/(σ_p k_0 T)$ and a resolution-limited sensitivity floor $Δg \simeq 4.4\,σ_p/(mT\sqrt{N})$, independent of photon momentum. When this criterion is not satisfied, partial mirror asymmetry can recover part of the enhancement, whereas population-based readout remains insensitive to detector blur and ultimately favors the conventional sequence at sufficiently large $n$. Estimates for $^{87}$Rb sensors show that the mirrorless advantage is primarily restricted to short-baseline instruments.

quant-pharXiv:2607.28749•Aug 3, 2026•0 citations

Robust atom optics for Bragg atom interferometry

Garrett Louie, Zilin Chen, Tejas Deshpande +1 more

Abstract Multi-photon Bragg diffraction is a powerful method for fast, coherent momentum transfer of atom waves. However, laser noise, Doppler detunings, and cloud expansion limit its efficiency in large momentum transfer (LMT) pulse sequences. We present simulation studies of robust Bragg pulses developed through numerical quantum optimal control. Optimized pulse performance under noise and cloud inhomogeneities is analyzed and compared to analogous Gaussian and adiabatic rapid passage pulses in simulated LMT Mach–Zehnder interferometry sequences. The optimized pulses maintain robust population transfer and phase response over a broader range of noise, resulting in superior contrast in LMT sequences with thermal atom clouds and intensity inhomogeneities. Large optimized LMT sequences use lower pulse area than Gaussian pulses, making them less susceptible to spontaneous emission loss. The optimized sequences maintain over five times better contrast with tens of ℏ k momentum separation and offer more improvement with greater LMT. Such pulses could allow operation of Bragg atom interferometers with unprecedented sensitivity, improved contrast, and hotter atom sources.

arXiv:2303.16950•New Journal of Physics•Jul 27, 2023•24 citations

Phase response of atom interferometers based on sequential Bragg diffractions

Boris Décamps, Maxime Bordoux, J Alibert +2 more

Abstract Large momentum transfer (LMT) beam splitters are implemented in atom interferometers to increase their sensitivity. However, an LMT interferometer requires additional light pulses to modify the response function of the atom interferometer. In this paper, we develop an analytical model for the sensitivity function of LMT interferometers using sequential accelerating light pulses. We use the sensitivity function to calculate the acceleration sensitivity taking into account the pulse duration. In addition, the sensitivity to laser phase fluctuations is calculated, and we show that the pulse sequence can be engineered to mitigate the phase noise sensitivity.

arXiv:1812.03027•Journal of Physics B Atomic Molecular and Optical Physics•Nov 14, 2018•8 citations
Clock atom interferometry is an emerging technique in precision measurements that is particularly well suited for sensitivity enhancement through large momentum transfer (LMT). While current systems have demonstrated momentum separations of several hundreds of photon momenta, next-generation quantum sensors are targeting an LMT enhancement factor beyond 10410^4104. However, the viability of LMT clock interferometers has recently come into question due to the potential impact of laser frequency noise. Here, we resolve this concern by analyzing the cumulative fidelity of sequential state inversions in an LMT atom interferometer. We show that the population error from nnn pulses applied from alternating directions scales linearly with nnn. This is a significant advantage over the n2n^2n2 scaling that occurs when probing a two-level system nnn times from the same direction. We further show that contributions to the interferometer signal from parasitic paths generated by imperfect pulses are negligible, for any loss mechanism. These results establish that laser frequency noise is not a practical limitation for the development of high-fidelity LMT clock atom interferometers.
Clock atom interferometry is an emerging technique in precision measurement, well suited for sensitivity enhancement through large momentum transfer (LMT). Although next-generation sensors aim for LMT factors beyond 10410^4104, their feasibility has been questioned due to potential impacts of laser frequency noise. We address this concern by analyzing the cumulative fidelity of sequential state inversions, showing that population error scales linearly with pulse number, not quadratically. Parasitic interferometer paths from imperfect pulses contribute negligibly, confirming that laser frequency noise is not a practical limitation.
A point source interferometer (PSI) is a device where atoms are split and recombined by applying a temporal sequence of Raman pulses. During the pulse sequence, an initially trapped cloud of cold atoms is released and allowed to expand, behaving approximately as a point source. The PSI can work as a sensitive multi-axes gyroscope that can automatically filter out the signal from accelerations. The phase shift arising from rotations is proportional to the momentum transferred to each atom from the Raman pulses. Therefore, by increasing the momentum transfer, it should be possibly to enhance the sensitivity of the PSI. Here, we investigate the degree of enhancement in sensitivity that could be achieved by augmenting the PSI with large momentum transfer (LMT) employing a sequence of many Raman pulses with alternating directions. Contrary to typical approaches used for describing a PSI, we employ a model under which the motion of the center of mass of each atom is described quantum mechanically. We show how increasing Doppler shifts lead to imperfections, thereby limiting the visibility of the signal fringes, and identify ways to suppress this effect by increasing the effective, two-photon Rabi frequencies of the Raman pulses. Considering the effect of spontaneous emission, we show that for a given value of the one-photon Rabi frequency, there is an optimum value for the number of pulses employed, beyond which the net enhancement in sensitivity begins to decrease. For a one-photon Rabi frequency of 200 MHz, for example, the peak value of the factor of enhancement in sensitivity is ~39, for a momentum transfer that is ~69 times as large as that for a conventional PSI. We also find that this peak value scales as the one-photon Rabi frequency to the power of 4/5.
Large-momentum-transfer (LMT) atom interferometry provides a route toward enhanced inertial sensitivity in compact quantum sensors, but its scalability is limited by the accumulation of pulse-transfer errors across long Raman pulse sequences. We investigate theoretically the use of stimulated Raman shortcut-to-adiabatic passage (STIRSAP) for high-fidelity LMT atom optics in a Mach--Zehnder interferometer geometry. The counterdiabatic correction is encoded directly into the Raman pulse envelopes, eliminating the need for auxiliary microwave or radio-frequency control fields. Numerical simulations based on an effective Raman model show that 1 μs1~μ\mathrm{s}1 μs STIRSAP pulses achieve single-pulse transfer fidelities of Fπ=0.99902F_π= 0.99902Fπ​=0.99902 while maintaining negligible pulse-time overhead even at high momentum order. We analyze the resulting tradeoff between interferometric phase enhancement and compound contrast decay and identify an unconstrained shot-noise optimum near n≈270n\approx270n≈270. The analysis further shows that practical operation at extreme LMT order is constrained by wave-packet separation, vibration noise, Doppler detuning, and accumulated systematic effects rather than by pulse duration itself. These results establish superadiabatic Raman control as a promising approach for scalable high-fidelity atom optics and clarify the physical limitations governing compact high-order atom interferometers.
Large momentum transfer (LMT) enhances the gravitational phase of a light-pulse atom interferometer by a factor nnn, while mirrorless operation with momentum-resolved detection can quadruple the phase-carrying quantum Fisher information. These gains compete in practice because the momentum-space fringe period scales as 1/n1/n1/n, making the fringe signal increasingly vulnerable to finite detector resolution. We analyze this trade-off in a solvable model with instantaneous lossless nnn-photon pulses, a Gaussian source, and Gaussian detection blur, allowing continuous interpolation between Kasevich--Chu and mirrorless geometries. Closed-form expressions for the blurred output distributions and classical Fisher information are obtained, with a fringe-phase averaging approximation whose error is exponentially suppressed and agrees with numerical simulations at the 10−810^{-8}10−8 level. We find that mirrorless operation surpasses a conventional interferometer with the same momentum transfer only when σp<0.91 m/(nk0T)σ_p < 0.91\,m/(n k_0 T)σp​<0.91m/(nk0​T). Fringe-based readout exhibits an optimal momentum transfer n∗≃0.93 m/(σpk0T)n^* \simeq 0.93\,m/(σ_p k_0 T)n∗≃0.93m/(σp​k0​T) and a resolution-limited sensitivity floor Δg≃4.4 σp/(mTN)Δg \simeq 4.4\,σ_p/(mT\sqrt{N})Δg≃4.4σp​/(mTN​), independent of photon momentum. When this criterion is not satisfied, partial mirror asymmetry can recover part of the enhancement, whereas population-based readout remains insensitive to detector blur and ultimately favors the conventional sequence at sufficiently large nnn. Estimates for 87^{87}87Rb sensors show that the mirrorless advantage is primarily restricted to short-baseline instruments.
Abstract Multi-photon Bragg diffraction is a powerful method for fast, coherent momentum transfer of atom waves. However, laser noise, Doppler detunings, and cloud expansion limit its efficiency in large momentum transfer (LMT) pulse sequences. We present simulation studies of robust Bragg pulses developed through numerical quantum optimal control. Optimized pulse performance under noise and cloud inhomogeneities is analyzed and compared to analogous Gaussian and adiabatic rapid passage pulses in simulated LMT Mach–Zehnder interferometry sequences. The optimized pulses maintain robust population transfer and phase response over a broader range of noise, resulting in superior contrast in LMT sequences with thermal atom clouds and intensity inhomogeneities. Large optimized LMT sequences use lower pulse area than Gaussian pulses, making them less susceptible to spontaneous emission loss. The optimized sequences maintain over five times better contrast with tens of ℏ k momentum separation and offer more improvement with greater LMT. Such pulses could allow operation of Bragg atom interferometers with unprecedented sensitivity, improved contrast, and hotter atom sources.
Abstract Large momentum transfer (LMT) beam splitters are implemented in atom interferometers to increase their sensitivity. However, an LMT interferometer requires additional light pulses to modify the response function of the atom interferometer. In this paper, we develop an analytical model for the sensitivity function of LMT interferometers using sequential accelerating light pulses. We use the sensitivity function to calculate the acceleration sensitivity taking into account the pulse duration. In addition, the sensitivity to laser phase fluctuations is calculated, and we show that the pulse sequence can be engineered to mitigate the phase noise sensitivity.