Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Dual atomic interferometry for differential inertial sensing

Jianing Li

Published Jan 1, 2023• 0 citations
Publisher

Abstract

The utilization of light-pulse atom interferometry presents a valuable technique that has found application in both fundamental scientific inquiries, such as investigating constants such as measurements of fine structure constant α and gravitational constant G, and practical endeavors including acceleration sensing and rotation measurements. This thesis delves into our implementation of a dual atom interferometer design involving the clock transition 1S0 → 3P0 in strontium, concurrently conducting the interferometric sequence on atoms in both ground and excited states. To facilitate the dual atom interferometer’s operation, we have firstly established a compact experimental setup with a transversely loaded bi-dimensional magneto-optical-trap (2D-MOT) to create a high flux source of cold strontium atoms. Introducing a novel cross-polarized bi-color atomic beam slower, we simultaneously addresses two excited Zeeman substates of the transition 1S0 → 1P1 in strontium-88, significantly enhancing the number of atoms prepared in the 461 nm MOT by around 10-fold. Following the 461 nm MOT, the atomic ensemble undergoes cooling in a 689 nm MOT, achieving atomic temperatures below 1 µK. We also install a network of eight magnetic field probes arranged around the cold atomic sample, enabling precise three-axis active control of magnetic fields down to the milligauss level. With the atoms confined in a 2D lattice at the magic-wavelength of 813.427 nm after the initial preparation phase, we conduct the magnetically-induced clock transition to create a statistical mixture state of ground and excited states. After a velocity selection stage, implementing a Mach-Zehnder interferometer with Bragg pulses operating at the magic-wavelength along the vertical axis, we conduct tests of the weak equivalence principle (WEP). The Eötvös ratio we found in our system stood at (1.8 ± 3.1) × 10−4, mainly limited by the finite temperature of the atomic cloud constraining the interrogation time. Furthermore, the dual atom interferometer scheme enables the measurement of state-dependent force and eventually polarizability difference via the phase shift between the atoms in different states, and we experimentally demonstrate this by introducing an additional light field gradient.

DOI
10.32657/10356/179606

Related papers

Magic-wavelength matter-wave interferometry with optical clock states

Jianing Li, Swarup Das, Xinyuan Ma +4 more

Optical clocks and atom interferometers provide complementary ways to measure time, motion and gravity. Combining these capabilities requires matter-wave beam splitters that manipulate different clock states in the same way, so that optical internal energy becomes a controlled degree of freedom rather than a source of systematic phase shifts. Here we realized a dual matter-wave interferometer operating simultaneously on the two states of the $^{88}$Sr optical clock transition, $^1S_0$ and $^3P_0$. The interferometer is driven by Bragg pulses at the 813 nm magic wavelength, for which the two clock states experience the same optical coupling strength. This realizes a common matter-wave beam splitter for atoms whose internal energies differ by an optical excitation. With a sensitivity of 30 mrad, our measurement is consistent with a zero differential phase shift between the two clock-state Mach-Zehnder interferometers, translating to an absence of state-dependent acceleration in free fall at the level of $10^{-5}$. We further used the same interferometer to measure state-dependent optical dipole forces and determine a tune-out wavelength of the metastable $^3P_0$ state to be 478.95(8) nm. These results establish magic-wavelength clock-state interferometry as a platform for differential force sensing, excited-state polarizability metrology and future quantum-clock tests of gravity.

arXiv:2608.17576•Aug 18, 2026•0 citations

Towards a two-photon E1-M1 clock transition excitation in ^{174}Yb for quantum clock interferometry

Montero Sanchez, Mario Antonio, Lezeik, Ali, Koester, Dominik +4 more

Atom interferometry experiments measuring gravitational redshift require access to long-lived internal states, such as the 1S0-3P0 optical transition in group II atoms. An E1-M1 two-photon excitation directly access the clock state from the ground state by coupling to a far detuned intermediate state through a pair of electric and magnetic dipole allowed transitions [1]. This avoids state mixing, enhancing the excited state’s lifetime. Moreover, using counter-propagating photons with degenerate frequencies eliminates first-order Doppler effects. We report the progress of our experimental setup to drive the clock transition. We prepare an ultra-cold atomic ensemble of 174Yb through a dual-stage magneto-optical trap sequence, followed by evaporative cooling in a crossed optical dipole trap [2]. To excite the transition, we utilize a high power (10 W), narrow-linewidth l1156 nm laser system referenced to a high-finesse cavity and a frequency comb. We discuss further applications of the two-photon Doppler-free excitation as a beam splliting method for quantum clock interferometry experiments. [1]PRA 90, 012523 (2014). [2]J.Phys.B 54, 035302 (2021)

•Mar 11, 2025•0 citations

A transportable cold atom inertial sensor for space applications

Rémi Geiger, Guillaume Stern, Patrick Cheinet +7 more

Atom interferometry has hugely benefitted from advances made in cold atom physics over the past twenty years, and ultra-precise quantum sensors are now available for a wide range of applications [1]. In particular, cold atom interferometers have shown excellent performances in the field of acceleration and rotation measurements [2,3], and are foreseen as promising candidates for navigation, geophysics, geo-prospecting and tests of fundamental physics such as the Universality of Free Fall (UFF). In order to carry out a test of the UFF with atoms as test masses, one needs to compare precisely the accelerations of two atoms with different masses as they fall in the Earth’s gravitational field. The sensitivity of atom interferometers scales like the square of the time during which the atoms are in free fall, and on ground this interrogation time is limited by the size of the experimental setup to a fraction of a second. Sending an atom interferometer in space would allow for several seconds of excellent free-fall conditions, and tests of the UFF could be carried out with precisions as low as 10-15 [4]. However, cold atoms experiments rely on complex laser systems, which are needed to cool down and manipulate the atoms, and these systems are usually very sensitive to temperature fluctuations and vibrations. In addition, when operating an inertial sensor, vibrations are a major issue, as they deteriorate the performances of the instrument. This is why cold atom interferometers are usually used in ground based facilities, which provide stable enough environments. In order to carry out airborne or space-borne measurements, one has to design an instrument which is both compact and stable, and such that vibrations induced by the platform will not deteriorate the sensitivity of the sensor. We report on the operation of an atom interferometer on board a plane carrying out parabolic flights (Airbus A300 Zero-G, operated by Novespace). We have constructed a compact and stable laser setup, which is well suited for onboard applications. Our goal is to implement a dual-species Rb-K atom interferometer in order to carry out a test of the UFF in the plane. In this perspective, we are designing a dual-wavelength laser source, which will enable us to cool down and coherently manipulate the quantum states of both atoms. We have successfully tested a preliminary version of the source and obtained a double species magneto-optical trap (MOT).

International Conference on Space Optics (ICSO)•Nov 20, 2017•3 citations

SIMULTANEOUS DUAL LASER STABILIZATION FOR STRONTIUM ATOM INTERFEROMETRY

Spakowski, Matthew D.

The use of strontium in an atom interferometer presents the opportunity to perform detailed measurements of gravitational fields, rotation rates, and clock transitions as well as other natural phenomena. Strontium can be particularly effective in atom interferometry experiments for two reasons. The first is that the intrinsic magnetic properties of strontium result in less sensitivity of the transition frequencies to magnetic noise, allowing for better measurements. Second, strontium atoms can be cooled to a lower temperature just through ordinary Doppler cooling than other atoms typically used in interferometry (e.g., rubidium). A lower temperature means less initial kinetic energy and hence lower spatial dispersion over the course of an experiment. A magneto-optical trap consisting of two primary cooling lasers and two repump lasers cools and confines strontium atoms for use in the interferometer. This thesis focuses on the repump lasers and includes the design and performance of the optical system that frequency stabilizes each laser. The system demonstrated the ability to simultaneously frequency lock the two repump lasers to the degree necessary to form a strontium magneto-optical trap.

•Sep 1, 2022•0 citations

Closed-loop dual-atom-interferometer inertial sensor with continuous cold atomic beams

Zhi-Xin Meng, Pei-Qiang Yan, Shengzhe Wang +3 more

We demonstrate a closed-loop light-pulse atom-interferometer inertial sensor that can realize continuous decoupled measurements of acceleration and rotation rate. The sensor operates with double-loop atom interferometers, which share the same Raman light pulses in a spatially separated Mach-Zehnder configuration and use continuous cold atomic beams propagating in opposite directions from two ${\text{2D}}^{+}$ magneto-optical trappings. Acceleration and the rotation rate are decoupled and simultaneously measured by the sum and difference of dual-atom-interferometer signals, respectively. The sensitivities of inertial measurements are also increased to be approximately 1.86 times higher than that of a single atom interferometer. The acceleration phase shift is compensated in real time by phase locking these interferometers via the Raman laser phases from the sum-interferometer signal, and the gyroscope performance is improved. We achieve long-term stabilities of $6.1\phantom{\rule{0.2em}{0ex}}\text{\ensuremath{\mu}}\text{g}$ and 840 nrad/s for the acceleration and the rotation rate, respectively, using a short interrogation time of 0.87 ms (interference area $A=0.097\phantom{\rule{0.2em}{0ex}}{\text{mm}}^{2}$). This work provides a building block for an atomic interferometer-based inertial measurement unit for use in field applications that require a high data rate and high stability.

arXiv:2210.15346•Physical Review Applied•Mar 22, 2024•23 citations

Versatile optical potentials and their applications in atom interferometry

Knut Stolzenberg

Inertial navigation systems are vital for modern society, be it on airplanes or in the context of autonomous mobility. On the other hand atom interferometers are exquisite measurement devices for inertia in fundamental physics and field applications, but are mostly limited to measuring one inertial observable. By utilizing time averaged optical potentials, the ultra-cold atomic ensemble input to the interferometer can be prepared in nearly arbitrary fashion. This results in a boost of preparation speed and number of atoms in the interferometer by increasing the size of the trap to match the size of the pre-cooled ensemble for optimal loading. Successive fast reduction of the extend of the trap leads to optimal evaporation efficiency and leads to increased sensitivity of the device, due to reduced cycle time of the experiment and increased atom number. Beyond this, the technique allows for new sensor geometries via the creation of multiple single wells, allowing for differential atom interferometry with numerous simultaneous interferometers. In this thesis, the first matter-wave analogue of a classical accelerometer array is implemented via the creation of a 3 × 3 array of Bose-Einstein condensates, consisting of 3 × 105 atoms and spanning a total area of 1.6 mm2 . Successive manipulation of the matter-waves with atom optics, coherently addressing the momentum states of the ensembles, allows for splitting, redirecting and readout pulses, realizing Mach-Zehnder type atom interferometers. Correlation of the nine 1D-acceleration measurements output by the interferometers yields measurements of linear acceleration, Euler- and centrifugal acceleration. The estimated sensitivity limits per shot are 6 × 10−5m s−2 for linear acceleration, 0.19 rad s − 2 for rotational acceleration and 203 mrad s−1 for rotation rate and are mainly limited due to the short free fall time of the ensembles, constrained by the atom optics light field. The correlation also allowed to determine the rotation center, being close to the retro reflection mirror of the atom optics light field. Crucial for the realization of this measurement was the implementation of time averaged potentials as stated above, facilitated through two 2D acousto-optical deflectors and a software defined radio, allowing for generating the required RF-signals. The techniques to simultaneously load and evaporate multiple ensembles into distinct traps from a single cloud of cold atoms and subsequently enlarge the spacing between the ensembles with adiabatic transport ramps are of highest interest for e.g. the Very Long Baseline Atom Interferometer facility in Hannover. Due to the correlated outputs systematic errors, such as wave front abberations, can be nullified. Furthermore the scheme can be extended to 3D matter-wave arrays, fulfilling all requirements necessary for an autonomous inertial measurement unit.

•Jan 1, 2026•0 citations
The utilization of light-pulse atom interferometry presents a valuable technique that has found application in both fundamental scientific inquiries, such as investigating constants such as measurements of fine structure constant α and gravitational constant G, and practical endeavors including acceleration sensing and rotation measurements. This thesis delves into our implementation of a dual atom interferometer design involving the clock transition 1S0 → 3P0 in strontium, concurrently conducting the interferometric sequence on atoms in both ground and excited states. To facilitate the dual atom interferometer’s operation, we have firstly established a compact experimental setup with a transversely loaded bi-dimensional magneto-optical-trap (2D-MOT) to create a high flux source of cold strontium atoms. Introducing a novel cross-polarized bi-color atomic beam slower, we simultaneously addresses two excited Zeeman substates of the transition 1S0 → 1P1 in strontium-88, significantly enhancing the number of atoms prepared in the 461 nm MOT by around 10-fold. Following the 461 nm MOT, the atomic ensemble undergoes cooling in a 689 nm MOT, achieving atomic temperatures below 1 µK. We also install a network of eight magnetic field probes arranged around the cold atomic sample, enabling precise three-axis active control of magnetic fields down to the milligauss level. With the atoms confined in a 2D lattice at the magic-wavelength of 813.427 nm after the initial preparation phase, we conduct the magnetically-induced clock transition to create a statistical mixture state of ground and excited states. After a velocity selection stage, implementing a Mach-Zehnder interferometer with Bragg pulses operating at the magic-wavelength along the vertical axis, we conduct tests of the weak equivalence principle (WEP). The Eötvös ratio we found in our system stood at (1.8 ± 3.1) × 10−4, mainly limited by the finite temperature of the atomic cloud constraining the interrogation time. Furthermore, the dual atom interferometer scheme enables the measurement of state-dependent force and eventually polarizability difference via the phase shift between the atoms in different states, and we experimentally demonstrate this by introducing an additional light field gradient.
Optical clocks and atom interferometers provide complementary ways to measure time, motion and gravity. Combining these capabilities requires matter-wave beam splitters that manipulate different clock states in the same way, so that optical internal energy becomes a controlled degree of freedom rather than a source of systematic phase shifts. Here we realized a dual matter-wave interferometer operating simultaneously on the two states of the 88^{88}88Sr optical clock transition, 1S0^1S_01S0​ and 3P0^3P_03P0​. The interferometer is driven by Bragg pulses at the 813 nm magic wavelength, for which the two clock states experience the same optical coupling strength. This realizes a common matter-wave beam splitter for atoms whose internal energies differ by an optical excitation. With a sensitivity of 30 mrad, our measurement is consistent with a zero differential phase shift between the two clock-state Mach-Zehnder interferometers, translating to an absence of state-dependent acceleration in free fall at the level of 10−510^{-5}10−5. We further used the same interferometer to measure state-dependent optical dipole forces and determine a tune-out wavelength of the metastable 3P0^3P_03P0​ state to be 478.95(8) nm. These results establish magic-wavelength clock-state interferometry as a platform for differential force sensing, excited-state polarizability metrology and future quantum-clock tests of gravity.
Atom interferometry experiments measuring gravitational redshift require access to long-lived internal states, such as the 1S0-3P0 optical transition in group II atoms. An E1-M1 two-photon excitation directly access the clock state from the ground state by coupling to a far detuned intermediate state through a pair of electric and magnetic dipole allowed transitions [1]. This avoids state mixing, enhancing the excited state’s lifetime. Moreover, using counter-propagating photons with degenerate frequencies eliminates first-order Doppler effects. We report the progress of our experimental setup to drive the clock transition. We prepare an ultra-cold atomic ensemble of 174Yb through a dual-stage magneto-optical trap sequence, followed by evaporative cooling in a crossed optical dipole trap [2]. To excite the transition, we utilize a high power (10 W), narrow-linewidth l1156 nm laser system referenced to a high-finesse cavity and a frequency comb. We discuss further applications of the two-photon Doppler-free excitation as a beam splliting method for quantum clock interferometry experiments. [1]PRA 90, 012523 (2014). [2]J.Phys.B 54, 035302 (2021)
Atom interferometry has hugely benefitted from advances made in cold atom physics over the past twenty years, and ultra-precise quantum sensors are now available for a wide range of applications [1]. In particular, cold atom interferometers have shown excellent performances in the field of acceleration and rotation measurements [2,3], and are foreseen as promising candidates for navigation, geophysics, geo-prospecting and tests of fundamental physics such as the Universality of Free Fall (UFF). In order to carry out a test of the UFF with atoms as test masses, one needs to compare precisely the accelerations of two atoms with different masses as they fall in the Earth’s gravitational field. The sensitivity of atom interferometers scales like the square of the time during which the atoms are in free fall, and on ground this interrogation time is limited by the size of the experimental setup to a fraction of a second. Sending an atom interferometer in space would allow for several seconds of excellent free-fall conditions, and tests of the UFF could be carried out with precisions as low as 10-15 [4]. However, cold atoms experiments rely on complex laser systems, which are needed to cool down and manipulate the atoms, and these systems are usually very sensitive to temperature fluctuations and vibrations. In addition, when operating an inertial sensor, vibrations are a major issue, as they deteriorate the performances of the instrument. This is why cold atom interferometers are usually used in ground based facilities, which provide stable enough environments. In order to carry out airborne or space-borne measurements, one has to design an instrument which is both compact and stable, and such that vibrations induced by the platform will not deteriorate the sensitivity of the sensor. We report on the operation of an atom interferometer on board a plane carrying out parabolic flights (Airbus A300 Zero-G, operated by Novespace). We have constructed a compact and stable laser setup, which is well suited for onboard applications. Our goal is to implement a dual-species Rb-K atom interferometer in order to carry out a test of the UFF in the plane. In this perspective, we are designing a dual-wavelength laser source, which will enable us to cool down and coherently manipulate the quantum states of both atoms. We have successfully tested a preliminary version of the source and obtained a double species magneto-optical trap (MOT).
The use of strontium in an atom interferometer presents the opportunity to perform detailed measurements of gravitational fields, rotation rates, and clock transitions as well as other natural phenomena. Strontium can be particularly effective in atom interferometry experiments for two reasons. The first is that the intrinsic magnetic properties of strontium result in less sensitivity of the transition frequencies to magnetic noise, allowing for better measurements. Second, strontium atoms can be cooled to a lower temperature just through ordinary Doppler cooling than other atoms typically used in interferometry (e.g., rubidium). A lower temperature means less initial kinetic energy and hence lower spatial dispersion over the course of an experiment. A magneto-optical trap consisting of two primary cooling lasers and two repump lasers cools and confines strontium atoms for use in the interferometer. This thesis focuses on the repump lasers and includes the design and performance of the optical system that frequency stabilizes each laser. The system demonstrated the ability to simultaneously frequency lock the two repump lasers to the degree necessary to form a strontium magneto-optical trap.
We demonstrate a closed-loop light-pulse atom-interferometer inertial sensor that can realize continuous decoupled measurements of acceleration and rotation rate. The sensor operates with double-loop atom interferometers, which share the same Raman light pulses in a spatially separated Mach-Zehnder configuration and use continuous cold atomic beams propagating in opposite directions from two 2D+{\text{2D}}^{+}2D+ magneto-optical trappings. Acceleration and the rotation rate are decoupled and simultaneously measured by the sum and difference of dual-atom-interferometer signals, respectively. The sensitivities of inertial measurements are also increased to be approximately 1.86 times higher than that of a single atom interferometer. The acceleration phase shift is compensated in real time by phase locking these interferometers via the Raman laser phases from the sum-interferometer signal, and the gyroscope performance is improved. We achieve long-term stabilities of $6.1\phantom{\rule{0.2em}{0ex}}\text{\ensuremath{\mu}}\text{g}$ and 840 nrad/s for the acceleration and the rotation rate, respectively, using a short interrogation time of 0.87 ms (interference area A=0.097mm2A=0.097\phantom{\rule{0.2em}{0ex}}{\text{mm}}^{2}A=0.097mm2). This work provides a building block for an atomic interferometer-based inertial measurement unit for use in field applications that require a high data rate and high stability.
Inertial navigation systems are vital for modern society, be it on airplanes or in the context of autonomous mobility. On the other hand atom interferometers are exquisite measurement devices for inertia in fundamental physics and field applications, but are mostly limited to measuring one inertial observable. By utilizing time averaged optical potentials, the ultra-cold atomic ensemble input to the interferometer can be prepared in nearly arbitrary fashion. This results in a boost of preparation speed and number of atoms in the interferometer by increasing the size of the trap to match the size of the pre-cooled ensemble for optimal loading. Successive fast reduction of the extend of the trap leads to optimal evaporation efficiency and leads to increased sensitivity of the device, due to reduced cycle time of the experiment and increased atom number. Beyond this, the technique allows for new sensor geometries via the creation of multiple single wells, allowing for differential atom interferometry with numerous simultaneous interferometers. In this thesis, the first matter-wave analogue of a classical accelerometer array is implemented via the creation of a 3 × 3 array of Bose-Einstein condensates, consisting of 3 × 105 atoms and spanning a total area of 1.6 mm2 . Successive manipulation of the matter-waves with atom optics, coherently addressing the momentum states of the ensembles, allows for splitting, redirecting and readout pulses, realizing Mach-Zehnder type atom interferometers. Correlation of the nine 1D-acceleration measurements output by the interferometers yields measurements of linear acceleration, Euler- and centrifugal acceleration. The estimated sensitivity limits per shot are 6 × 10−5m s−2 for linear acceleration, 0.19 rad s − 2 for rotational acceleration and 203 mrad s−1 for rotation rate and are mainly limited due to the short free fall time of the ensembles, constrained by the atom optics light field. The correlation also allowed to determine the rotation center, being close to the retro reflection mirror of the atom optics light field. Crucial for the realization of this measurement was the implementation of time averaged potentials as stated above, facilitated through two 2D acousto-optical deflectors and a software defined radio, allowing for generating the required RF-signals. The techniques to simultaneously load and evaporate multiple ensembles into distinct traps from a single cloud of cold atoms and subsequently enlarge the spacing between the ensembles with adiabatic transport ramps are of highest interest for e.g. the Very Long Baseline Atom Interferometer facility in Hannover. Due to the correlated outputs systematic errors, such as wave front abberations, can be nullified. Furthermore the scheme can be extended to 3D matter-wave arrays, fulfilling all requirements necessary for an autonomous inertial measurement unit.