Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1807.00946 · Physical Review Applied

Influence of Dynamical Decoupling Sequences with Finite-Width Pulses on Quantum Sensing for AC Magnetometry

T. Ishikawa, Akio Yoshizawa, Yasunori Mawatari, Hideyuki Watanabe, Satoshi Kashiwaya

Published Nov 27, 2018• 18 citations
arXivHTMLPDF

Abstract

Dynamical decoupling sequences of multiple pulses offer filter functions for the time evolution of a qubit superposition state, and thus are indispensable tools for quantum sensing. The authors investigate the effects of sequences of finite-width pulses on ac magnetometry based on nitrogen-vacancy centers in isotopically controlled diamond. This experimental and theoretical study shows that finite pulse width alters the optimum acquisition time, and shows how to correct the resulting frequency shift, providing a guideline for accurate measurement of the frequency, linewidth, and amplitude of an ac field.

DOI
10.1103/physrevapplied.10.054059

Related papers

Finite-pulse-width effect on quantum sensing for an asynchronous alternating-current magnetic field to dynamical decoupling sequences

T. Ishikawa, Akio Yoshizawa, Yasunori Mawatari +2 more

Quantum sensors based on the electron spin states of nitrogen vacancy centers in diamond have found wide application in magnetometry and nuclear spin magnetic resonance measurements. Previously, we have theoretically and experimentally investigated the effect of finite pulse width on quantum sensing for synchronous alternating-current (AC) magnetic fields to dynamical decoupling sequences [T. Ishikawa et al., Phys. Rev. Appl. 10, 054059 (2018)]. However, many biological and condensed-matter systems exhibit fluctuating AC fields over time, and thus, our model needs modifications because of additional non-ideal conditions in practical measurements. Here, we investigate the effects of finite pulse width of multiple-pulse decoupling sequences on quantum sensing for asynchronous AC magnetic fields. For this purpose, we use a spin ensemble of nitrogen vacancy centers in an isotopically purified diamond film. We reveal through experiments that the finite-width pulse causes shifts in AC magnetometry signals in a free-precession-time plot. In addition, our results indicate that the finite-width pulse affects the amplitude of magnetometry signals, implying that the finite-pulse-width effect should be taken into account for realizing accurate measurement of the frequency and amplitude of asynchronous AC magnetic fields.

AIP Advances•Jul 1, 2019•3 citations

Sensitive measurement of phase shift of an AC magnetic field by quantum sensing with multiple-pulse decoupling sequences

T. Ishikawa, Akio Yoshizawa, Yasunori Mawatari +2 more

Magnetometry utilizing a spin qubit in a solid state possesses high sensitivity. In particular, a magnetic sensor with a high spatial resolution can be achieved with the electron-spin states of a nitrogen-vacancy (NV) center in the diamond. In this study, we demonstrated that NV quantum sensing based on multiple-pulse decoupling sequences can sensitively measure not only the amplitude but also the phase shift of an alternating-current (AC) magnetic field. In the AC magnetometry based on decoupling sequences, the maximum phase accumulation of the NV spin due to an AC-field can be generally obtained when the π-pulse period in the sequences matches the half time period of the field and the relative phase difference between the sequences and the field is zero. By contrast, the NV quantum sensor acquires no phase accumulation if the relative phase difference is π/2. Thus, this phase-accumulation condition does not have any advantage for the magnetometry. However, we revealed that the nonphase-accumulation condition is available for detecting a very small phase shift of an AC-field from its initial phase. Measurements of the real part and the imaginary part of AC impedance require the amplitude and the phase information of an AC-field, and thus, this finding is expected to provide a guide for realizing sensitive measurement of AC impedance in the micrometer and nanometer scales.

arXiv:1808.03784•Journal of Applied Physics•Aug 12, 2019•2 citations

Spin ensemble-based AC magnetometry using concatenated dynamical decoupling at low temperatures

Demitry Farfurnik, A Jarmola, D Budker +1 more

Abstract Ensembles of nitrogen-vacancy centers in diamond are widely used as AC magnetometers. While such measurements are usually performed using standard (XY) dynamical decoupling (DD) protocols at room temperature, we study the sensitivities achieved by utilizing various DD protocols, for measuring magnetic AC fields at frequencies in the 10–250 kHz range, at room temperature and 77 K. By performing measurements on an isotopically pure 12 C sample, we find that the Carr-Purcell–Meiboom-Gill protocol, which is not robust against pulse imperfections, is less efficient for magnetometry than robust XY-based sequences. The concatenation of a standard XY-based protocol may enhance the sensitivities only for measuring high-frequency fields, for which many ( > 500 ) DD pulses are necessary and the robustness against pulse imperfections is critical. Moreover, we show that cooling is effective only for measuring low-frequency fields (∼10 kHz), for which the experiment time approaches T 1 at a small number of applied DD pulses.

arXiv:1709.03368•Journal of Optics•Dec 14, 2017•15 citations

Continuous dynamical decoupling magnetometry

Masashi Hirose, Clarice D. Aiello, Paola Cappellaro

Solid-state qubits hold the promise to achieve an unmatched combination of sensitivity and spatial resolution. To achieve their potential, the qubits need, however, to be shielded from the deleterious effects of the environment. While dynamical decoupling techniques can improve the coherence time, they impose a compromise between sensitivity and the frequency range of the field to be measured. Moreover, the performance of pulse sequences is ultimately limited by control bounds and errors. Here we analyze a versatile alternative based on continuous driving. We find that continuous dynamical decoupling schemes can be used for ac magnetometry, providing similar frequency constraints on the ac field and improved sensitivity for some noise regimes. In addition, the flexibility of phase and amplitude modulation could yield superior robustness to driving errors and a better adaptability to external experimental scenarios.

arXiv:1207.5729•Physical Review A•Dec 20, 2012•69 citations

Robust control of an ensemble of NV centers in diamond under inhomogeneous fields for sensitive magnetometry

Takuya Kitamura

Quantum sensing with solid-state spins has attracted considerable attention following the development of single quantum systems. In particular, sub-picotesla level magnetometry has been demonstrated using negatively-charged nitrogen-vacancy (NV) centers in diamond by increasing the number of spins simultaneously employed for sensing. However, scaling up the number of spins inevitably introduces inhomogeneities in detuning and control field amplitudes across the ensemble system, which degrades the achievable sensitivity. Although several techniques, including pulsed dynamical decoupling and shaped pulses, have been studied to overcome such noises, they are not generally compatible with GHz-range AC magnetometry based on Rabi oscillations. This dissertation presents the development of an experimental platform and the demonstration of robust GHz-range AC magnetometry using a large ensemble of NV centers under inhomogeneous fields. Particular emphasis is placed on the effects of control-field amplitude inhomogeneity. To improve the homogeneity of the control field, barrel-shaped microwave forming systems are experimentally characterized, and their performance is compared with that of planar systems. Then, to mitigate detuning noise as well as control-field amplitude noise, concatenated continuous dynamical decoupling (CCDD) is applied to the inhomogeneous ensemble system, and the resulting dynamics are investigated with several initial states prepared with composite pulses. Finally, the CCDD sequence is applied for GHz-range AC magnetometry and compared with the conventional direct Rabi method. The results demonstrate that the robust dressed states generated by CCDD extend the lower bound of measurable amplitudes in GHz-range AC magnetometry.

•Jan 1, 2026•0 citations

Continuous-wave AC magnetometry up to hundreds of megahertz using nitrogen-vacancy centers under a strong transverse magnetic field

Ryusei Okaniwa, Rui Suzuki, Yuichiro Matsuzaki +2 more

Nitrogen-vacancy (NV) centers in diamond are promising quantum sensors for AC magnetic fields. However, conventional dynamical-decoupling-based magnetometry becomes technically demanding at high frequencies because of the requirement for increasingly short and high-power microwave pulses. This paper describes an AC magnetometry technique based on continuous-wave optically detected magnetic resonance (CW-ODMR) measurements, which enables the detection of signals in the hundred-MHz range. By applying a strong static magnetic field transverse to the NV axis, the energy separation between the relevant electron-spin states was tuned and resonantly coupled with the target radiofrequency (RF) magnetic field, thereby forming RF-dressed states. Unlike pulsed dynamical-decoupling schemes, this approach does not require high-power microwave pulse sequences. The key feature of our method is that the detectable frequency can be tuned by controlling the bias magnetic field strength. Using this methodology, we have experimentally achieved the frequency-tunable detection of AC magnetic fields from 14.4-632 MHz. The sensitivity was 0.558 uT/Hz^(0.5) at 14.4 MHz and 24.4 uT/Hz^(0.5) at 632 MHz. We characterized the field-dependent ODMR contrast and linewidth, and found that their degradation at large transverse fields is a important factor limiting the high-frequency sensitivity. These results establish a simple CW-ODMR approach for widely tunable RF magnetic-field sensing without high-power pulsed spin control.

quant-pharXiv:2610.13153•Oct 12, 2026•0 citations
Dynamical decoupling sequences of multiple pulses offer filter functions for the time evolution of a qubit superposition state, and thus are indispensable tools for quantum sensing. The authors investigate the effects of sequences of finite-width pulses on ac magnetometry based on nitrogen-vacancy centers in isotopically controlled diamond. This experimental and theoretical study shows that finite pulse width alters the optimum acquisition time, and shows how to correct the resulting frequency shift, providing a guideline for accurate measurement of the frequency, linewidth, and amplitude of an ac field.
Quantum sensors based on the electron spin states of nitrogen vacancy centers in diamond have found wide application in magnetometry and nuclear spin magnetic resonance measurements. Previously, we have theoretically and experimentally investigated the effect of finite pulse width on quantum sensing for synchronous alternating-current (AC) magnetic fields to dynamical decoupling sequences [T. Ishikawa et al., Phys. Rev. Appl. 10, 054059 (2018)]. However, many biological and condensed-matter systems exhibit fluctuating AC fields over time, and thus, our model needs modifications because of additional non-ideal conditions in practical measurements. Here, we investigate the effects of finite pulse width of multiple-pulse decoupling sequences on quantum sensing for asynchronous AC magnetic fields. For this purpose, we use a spin ensemble of nitrogen vacancy centers in an isotopically purified diamond film. We reveal through experiments that the finite-width pulse causes shifts in AC magnetometry signals in a free-precession-time plot. In addition, our results indicate that the finite-width pulse affects the amplitude of magnetometry signals, implying that the finite-pulse-width effect should be taken into account for realizing accurate measurement of the frequency and amplitude of asynchronous AC magnetic fields.
Magnetometry utilizing a spin qubit in a solid state possesses high sensitivity. In particular, a magnetic sensor with a high spatial resolution can be achieved with the electron-spin states of a nitrogen-vacancy (NV) center in the diamond. In this study, we demonstrated that NV quantum sensing based on multiple-pulse decoupling sequences can sensitively measure not only the amplitude but also the phase shift of an alternating-current (AC) magnetic field. In the AC magnetometry based on decoupling sequences, the maximum phase accumulation of the NV spin due to an AC-field can be generally obtained when the π-pulse period in the sequences matches the half time period of the field and the relative phase difference between the sequences and the field is zero. By contrast, the NV quantum sensor acquires no phase accumulation if the relative phase difference is π/2. Thus, this phase-accumulation condition does not have any advantage for the magnetometry. However, we revealed that the nonphase-accumulation condition is available for detecting a very small phase shift of an AC-field from its initial phase. Measurements of the real part and the imaginary part of AC impedance require the amplitude and the phase information of an AC-field, and thus, this finding is expected to provide a guide for realizing sensitive measurement of AC impedance in the micrometer and nanometer scales.
Abstract Ensembles of nitrogen-vacancy centers in diamond are widely used as AC magnetometers. While such measurements are usually performed using standard (XY) dynamical decoupling (DD) protocols at room temperature, we study the sensitivities achieved by utilizing various DD protocols, for measuring magnetic AC fields at frequencies in the 10–250 kHz range, at room temperature and 77 K. By performing measurements on an isotopically pure 12 C sample, we find that the Carr-Purcell–Meiboom-Gill protocol, which is not robust against pulse imperfections, is less efficient for magnetometry than robust XY-based sequences. The concatenation of a standard XY-based protocol may enhance the sensitivities only for measuring high-frequency fields, for which many ( > 500 ) DD pulses are necessary and the robustness against pulse imperfections is critical. Moreover, we show that cooling is effective only for measuring low-frequency fields (∼10 kHz), for which the experiment time approaches T 1 at a small number of applied DD pulses.
Solid-state qubits hold the promise to achieve an unmatched combination of sensitivity and spatial resolution. To achieve their potential, the qubits need, however, to be shielded from the deleterious effects of the environment. While dynamical decoupling techniques can improve the coherence time, they impose a compromise between sensitivity and the frequency range of the field to be measured. Moreover, the performance of pulse sequences is ultimately limited by control bounds and errors. Here we analyze a versatile alternative based on continuous driving. We find that continuous dynamical decoupling schemes can be used for ac magnetometry, providing similar frequency constraints on the ac field and improved sensitivity for some noise regimes. In addition, the flexibility of phase and amplitude modulation could yield superior robustness to driving errors and a better adaptability to external experimental scenarios.
Quantum sensing with solid-state spins has attracted considerable attention following the development of single quantum systems. In particular, sub-picotesla level magnetometry has been demonstrated using negatively-charged nitrogen-vacancy (NV) centers in diamond by increasing the number of spins simultaneously employed for sensing. However, scaling up the number of spins inevitably introduces inhomogeneities in detuning and control field amplitudes across the ensemble system, which degrades the achievable sensitivity. Although several techniques, including pulsed dynamical decoupling and shaped pulses, have been studied to overcome such noises, they are not generally compatible with GHz-range AC magnetometry based on Rabi oscillations. This dissertation presents the development of an experimental platform and the demonstration of robust GHz-range AC magnetometry using a large ensemble of NV centers under inhomogeneous fields. Particular emphasis is placed on the effects of control-field amplitude inhomogeneity. To improve the homogeneity of the control field, barrel-shaped microwave forming systems are experimentally characterized, and their performance is compared with that of planar systems. Then, to mitigate detuning noise as well as control-field amplitude noise, concatenated continuous dynamical decoupling (CCDD) is applied to the inhomogeneous ensemble system, and the resulting dynamics are investigated with several initial states prepared with composite pulses. Finally, the CCDD sequence is applied for GHz-range AC magnetometry and compared with the conventional direct Rabi method. The results demonstrate that the robust dressed states generated by CCDD extend the lower bound of measurable amplitudes in GHz-range AC magnetometry.
Nitrogen-vacancy (NV) centers in diamond are promising quantum sensors for AC magnetic fields. However, conventional dynamical-decoupling-based magnetometry becomes technically demanding at high frequencies because of the requirement for increasingly short and high-power microwave pulses. This paper describes an AC magnetometry technique based on continuous-wave optically detected magnetic resonance (CW-ODMR) measurements, which enables the detection of signals in the hundred-MHz range. By applying a strong static magnetic field transverse to the NV axis, the energy separation between the relevant electron-spin states was tuned and resonantly coupled with the target radiofrequency (RF) magnetic field, thereby forming RF-dressed states. Unlike pulsed dynamical-decoupling schemes, this approach does not require high-power microwave pulse sequences. The key feature of our method is that the detectable frequency can be tuned by controlling the bias magnetic field strength. Using this methodology, we have experimentally achieved the frequency-tunable detection of AC magnetic fields from 14.4-632 MHz. The sensitivity was 0.558 uT/Hz^(0.5) at 14.4 MHz and 24.4 uT/Hz^(0.5) at 632 MHz. We characterized the field-dependent ODMR contrast and linewidth, and found that their degradation at large transverse fields is a important factor limiting the high-frequency sensitivity. These results establish a simple CW-ODMR approach for widely tunable RF magnetic-field sensing without high-power pulsed spin control.