Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

AIP Advances

Finite-pulse-width effect on quantum sensing for an asynchronous alternating-current magnetic field to dynamical decoupling sequences

T. Ishikawa, Akio Yoshizawa, Yasunori Mawatari, Satoshi Kashiwaya, Hideyuki Watanabe

Published Jul 1, 2019• 3 citations
Publisher

Abstract

Quantum sensors based on the electron spin states of nitrogen vacancy centers in diamond have found wide application in magnetometry and nuclear spin magnetic resonance measurements. Previously, we have theoretically and experimentally investigated the effect of finite pulse width on quantum sensing for synchronous alternating-current (AC) magnetic fields to dynamical decoupling sequences [T. Ishikawa et al., Phys. Rev. Appl. 10, 054059 (2018)]. However, many biological and condensed-matter systems exhibit fluctuating AC fields over time, and thus, our model needs modifications because of additional non-ideal conditions in practical measurements. Here, we investigate the effects of finite pulse width of multiple-pulse decoupling sequences on quantum sensing for asynchronous AC magnetic fields. For this purpose, we use a spin ensemble of nitrogen vacancy centers in an isotopically purified diamond film. We reveal through experiments that the finite-width pulse causes shifts in AC magnetometry signals in a free-precession-time plot. In addition, our results indicate that the finite-width pulse affects the amplitude of magnetometry signals, implying that the finite-pulse-width effect should be taken into account for realizing accurate measurement of the frequency and amplitude of asynchronous AC magnetic fields.

DOI
10.1063/1.5097872

Related papers

Influence of Dynamical Decoupling Sequences with Finite-Width Pulses on Quantum Sensing for AC Magnetometry

T. Ishikawa, Akio Yoshizawa, Yasunori Mawatari +2 more

Dynamical decoupling sequences of multiple pulses offer filter functions for the time evolution of a qubit superposition state, and thus are indispensable tools for quantum sensing. The authors investigate the effects of sequences of finite-width pulses on ac magnetometry based on nitrogen-vacancy centers in isotopically controlled diamond. This experimental and theoretical study shows that finite pulse width alters the optimum acquisition time, and shows how to correct the resulting frequency shift, providing a guideline for accurate measurement of the frequency, linewidth, and amplitude of an ac field.

arXiv:1807.00946•Physical Review Applied•Nov 27, 2018•18 citations

Sensitive measurement of phase shift of an AC magnetic field by quantum sensing with multiple-pulse decoupling sequences

T. Ishikawa, Akio Yoshizawa, Yasunori Mawatari +2 more

Magnetometry utilizing a spin qubit in a solid state possesses high sensitivity. In particular, a magnetic sensor with a high spatial resolution can be achieved with the electron-spin states of a nitrogen-vacancy (NV) center in the diamond. In this study, we demonstrated that NV quantum sensing based on multiple-pulse decoupling sequences can sensitively measure not only the amplitude but also the phase shift of an alternating-current (AC) magnetic field. In the AC magnetometry based on decoupling sequences, the maximum phase accumulation of the NV spin due to an AC-field can be generally obtained when the π-pulse period in the sequences matches the half time period of the field and the relative phase difference between the sequences and the field is zero. By contrast, the NV quantum sensor acquires no phase accumulation if the relative phase difference is π/2. Thus, this phase-accumulation condition does not have any advantage for the magnetometry. However, we revealed that the nonphase-accumulation condition is available for detecting a very small phase shift of an AC-field from its initial phase. Measurements of the real part and the imaginary part of AC impedance require the amplitude and the phase information of an AC-field, and thus, this finding is expected to provide a guide for realizing sensitive measurement of AC impedance in the micrometer and nanometer scales.

arXiv:1808.03784•Journal of Applied Physics•Aug 12, 2019•2 citations

Ambiguous resonances in multipulse quantum sensing with nitrogen-vacancy centers

Lucas Tsunaki, Anmol Singh, Kseniia Volkova +4 more

Dynamical decoupling multipulse sequences can be applied to solid-state spins for sensing weak oscillating fields from nearby single nuclear spins. By periodically reversing the probing system's evolution, other noises are counteracted and filtered out over the total evolution. However, the technique is subject to intricate interactions resulting in additional resonant responses, which can be misinterpreted with the actual signal intended to be measured. We experimentally characterize three of these effects present in single nitrogen-vacancy centers in diamond, where we also develop a numerical simulation model without rotating-wave approximation, showing robust correlation to the experimental data. Regarding centers with the N 15 nitrogen isotope, we observe that a small misalignment in the bias magnetic field causes the precession of the nitrogen nuclear spin to be sensed by the electronic spin of the center. Another studied case of ambiguous resonances comes from the coupling with lattice C 13 nuclei, where we use the echo modulation frequencies to obtain the interaction Hamiltonian and then utilize the latter to simulate multipulse sequences. Finally, we also measure and simulate the effects from the free evolution of the quantum system during finite pulse durations. Due to the large data volume and the strong dependence of these ambiguous resonances with specific experimental parameters, we provide a simulations data set with a user-friendly graphical interface, where users can compare simulations with their own experimental data for spectral disambiguation. Although focused on nitrogen-vacancy centers and dynamical decoupling sequences, these results and the developed model can potentially be applied to other solid-state spins and quantum sensing techniques.

arXiv:2407.09411•Physical Review A•Feb 7, 2025•12 citations

Spin ensemble-based AC magnetometry using concatenated dynamical decoupling at low temperatures

Demitry Farfurnik, A Jarmola, D Budker +1 more

Abstract Ensembles of nitrogen-vacancy centers in diamond are widely used as AC magnetometers. While such measurements are usually performed using standard (XY) dynamical decoupling (DD) protocols at room temperature, we study the sensitivities achieved by utilizing various DD protocols, for measuring magnetic AC fields at frequencies in the 10–250 kHz range, at room temperature and 77 K. By performing measurements on an isotopically pure 12 C sample, we find that the Carr-Purcell–Meiboom-Gill protocol, which is not robust against pulse imperfections, is less efficient for magnetometry than robust XY-based sequences. The concatenation of a standard XY-based protocol may enhance the sensitivities only for measuring high-frequency fields, for which many ( > 500 ) DD pulses are necessary and the robustness against pulse imperfections is critical. Moreover, we show that cooling is effective only for measuring low-frequency fields (∼10 kHz), for which the experiment time approaches T 1 at a small number of applied DD pulses.

arXiv:1709.03368•Journal of Optics•Dec 14, 2017•15 citations

Phase sensitive quantum magnetometry imaging using ensemble NV center in diamond on wide field optics

Mizuno, Kosuke, Hitoshi Ishiwata, Y. MASUYAMA +2 more

Nitrogen—Vacancy (NV) center in diamond can detect tiny magnetic field due to relative long coherence time even at room temperature. Its optical accessibility and capability of thin-film formation provide us an interesting sensing modality such as wide field imaging. We have reported phase sensitive protocol for ac magnetic field designed for wide field setup.[1] In this study we demonstrate an application of phase sensitive protocol; measuring distribution of ac magnetic field strength by phase sensing. Previous methods of multi-pulse quantum sensing such as XY8 realize quite high sensitivity of ac magnetic field. Since XY8 has dependencies on strength and phase of ac magnetic field, it is necessary to adjust ac phase to an optimal point in order to obtain a best sensitivity, and we cannot distinguish the effect of amplitude and phase. Recent studies have showed utilizing time-domain information is effective for improving frequency resolution of quantum sensing,[2,3] and we found same technique is also effective for simultaneous measurement of strength and phase. Here we propose a robust method for amplitude estimation by phase sensing. We added another signal for reference, then sensing phase difference between target signal and reference can be converted into amplitude. Conventional XY8 sensing is based upon fluorescence measurement which can be affected easily by many obstacles such as stray light, autofluorescence, and fringes of excitation laser. In the other hand, our method can be more robust because it is based on phase measurement. Nothing can change the phase except absorption of ac signal. This work was supported by MEXT Q-LEAP, CAO PRISM, Japan. [1] Mizuno et al., AIP advances 2018 [2][3] Boss, Schmitt

•Jun 4, 2019•0 citations

Quantum Sensing of Non-Repeatable Events Enhanced by In-Sensor Quantum Reservoir Computing

Daiki Sasaki, Hideaki Kawaguchi, Yuichiro Matsuzaki

High-density nitrogen-vacancy (NV) ensembles in diamond enable sensitive magnetometry. Many quantum-sensing protocols rely on reproducible target fields, allowing repeated measurements under different sensing conditions. In dynamical decoupling (DD) magnetometry, sweeping the interval between $π$ pulses across repeated measurements enables estimation of the frequency and amplitude of an unknown alternating field. For non-repeatable events, however, the same field waveform cannot be reproduced for measurements under different settings. Here we propose NV-based in-sensor quantum reservoir computing (NV-QRC) for sensing such events. Field-driven many-body dynamics and simultaneous fluorescence readout from multiple spatial regions provide a classical classifier with multiple features from a single event. For binary phase classification, we benchmark NV-QRC against DD magnetometry using a single pulse sequence fixed in advance. We show that NV-QRC can retain class-dependent information in regimes where the fixed-DD protocol fails to capture it. These results identify non-repeatable-event sensing as a promising application of quantum reservoir computing.

quant-pharXiv:2609.06292•Sep 8, 2026•0 citations
Quantum sensors based on the electron spin states of nitrogen vacancy centers in diamond have found wide application in magnetometry and nuclear spin magnetic resonance measurements. Previously, we have theoretically and experimentally investigated the effect of finite pulse width on quantum sensing for synchronous alternating-current (AC) magnetic fields to dynamical decoupling sequences [T. Ishikawa et al., Phys. Rev. Appl. 10, 054059 (2018)]. However, many biological and condensed-matter systems exhibit fluctuating AC fields over time, and thus, our model needs modifications because of additional non-ideal conditions in practical measurements. Here, we investigate the effects of finite pulse width of multiple-pulse decoupling sequences on quantum sensing for asynchronous AC magnetic fields. For this purpose, we use a spin ensemble of nitrogen vacancy centers in an isotopically purified diamond film. We reveal through experiments that the finite-width pulse causes shifts in AC magnetometry signals in a free-precession-time plot. In addition, our results indicate that the finite-width pulse affects the amplitude of magnetometry signals, implying that the finite-pulse-width effect should be taken into account for realizing accurate measurement of the frequency and amplitude of asynchronous AC magnetic fields.
Dynamical decoupling sequences of multiple pulses offer filter functions for the time evolution of a qubit superposition state, and thus are indispensable tools for quantum sensing. The authors investigate the effects of sequences of finite-width pulses on ac magnetometry based on nitrogen-vacancy centers in isotopically controlled diamond. This experimental and theoretical study shows that finite pulse width alters the optimum acquisition time, and shows how to correct the resulting frequency shift, providing a guideline for accurate measurement of the frequency, linewidth, and amplitude of an ac field.
Magnetometry utilizing a spin qubit in a solid state possesses high sensitivity. In particular, a magnetic sensor with a high spatial resolution can be achieved with the electron-spin states of a nitrogen-vacancy (NV) center in the diamond. In this study, we demonstrated that NV quantum sensing based on multiple-pulse decoupling sequences can sensitively measure not only the amplitude but also the phase shift of an alternating-current (AC) magnetic field. In the AC magnetometry based on decoupling sequences, the maximum phase accumulation of the NV spin due to an AC-field can be generally obtained when the π-pulse period in the sequences matches the half time period of the field and the relative phase difference between the sequences and the field is zero. By contrast, the NV quantum sensor acquires no phase accumulation if the relative phase difference is π/2. Thus, this phase-accumulation condition does not have any advantage for the magnetometry. However, we revealed that the nonphase-accumulation condition is available for detecting a very small phase shift of an AC-field from its initial phase. Measurements of the real part and the imaginary part of AC impedance require the amplitude and the phase information of an AC-field, and thus, this finding is expected to provide a guide for realizing sensitive measurement of AC impedance in the micrometer and nanometer scales.
Dynamical decoupling multipulse sequences can be applied to solid-state spins for sensing weak oscillating fields from nearby single nuclear spins. By periodically reversing the probing system's evolution, other noises are counteracted and filtered out over the total evolution. However, the technique is subject to intricate interactions resulting in additional resonant responses, which can be misinterpreted with the actual signal intended to be measured. We experimentally characterize three of these effects present in single nitrogen-vacancy centers in diamond, where we also develop a numerical simulation model without rotating-wave approximation, showing robust correlation to the experimental data. Regarding centers with the N 15 nitrogen isotope, we observe that a small misalignment in the bias magnetic field causes the precession of the nitrogen nuclear spin to be sensed by the electronic spin of the center. Another studied case of ambiguous resonances comes from the coupling with lattice C 13 nuclei, where we use the echo modulation frequencies to obtain the interaction Hamiltonian and then utilize the latter to simulate multipulse sequences. Finally, we also measure and simulate the effects from the free evolution of the quantum system during finite pulse durations. Due to the large data volume and the strong dependence of these ambiguous resonances with specific experimental parameters, we provide a simulations data set with a user-friendly graphical interface, where users can compare simulations with their own experimental data for spectral disambiguation. Although focused on nitrogen-vacancy centers and dynamical decoupling sequences, these results and the developed model can potentially be applied to other solid-state spins and quantum sensing techniques.
Abstract Ensembles of nitrogen-vacancy centers in diamond are widely used as AC magnetometers. While such measurements are usually performed using standard (XY) dynamical decoupling (DD) protocols at room temperature, we study the sensitivities achieved by utilizing various DD protocols, for measuring magnetic AC fields at frequencies in the 10–250 kHz range, at room temperature and 77 K. By performing measurements on an isotopically pure 12 C sample, we find that the Carr-Purcell–Meiboom-Gill protocol, which is not robust against pulse imperfections, is less efficient for magnetometry than robust XY-based sequences. The concatenation of a standard XY-based protocol may enhance the sensitivities only for measuring high-frequency fields, for which many ( > 500 ) DD pulses are necessary and the robustness against pulse imperfections is critical. Moreover, we show that cooling is effective only for measuring low-frequency fields (∼10 kHz), for which the experiment time approaches T 1 at a small number of applied DD pulses.
Nitrogen—Vacancy (NV) center in diamond can detect tiny magnetic field due to relative long coherence time even at room temperature. Its optical accessibility and capability of thin-film formation provide us an interesting sensing modality such as wide field imaging. We have reported phase sensitive protocol for ac magnetic field designed for wide field setup.[1] In this study we demonstrate an application of phase sensitive protocol; measuring distribution of ac magnetic field strength by phase sensing. Previous methods of multi-pulse quantum sensing such as XY8 realize quite high sensitivity of ac magnetic field. Since XY8 has dependencies on strength and phase of ac magnetic field, it is necessary to adjust ac phase to an optimal point in order to obtain a best sensitivity, and we cannot distinguish the effect of amplitude and phase. Recent studies have showed utilizing time-domain information is effective for improving frequency resolution of quantum sensing,[2,3] and we found same technique is also effective for simultaneous measurement of strength and phase. Here we propose a robust method for amplitude estimation by phase sensing. We added another signal for reference, then sensing phase difference between target signal and reference can be converted into amplitude. Conventional XY8 sensing is based upon fluorescence measurement which can be affected easily by many obstacles such as stray light, autofluorescence, and fringes of excitation laser. In the other hand, our method can be more robust because it is based on phase measurement. Nothing can change the phase except absorption of ac signal. This work was supported by MEXT Q-LEAP, CAO PRISM, Japan. [1] Mizuno et al., AIP advances 2018 [2][3] Boss, Schmitt
High-density nitrogen-vacancy (NV) ensembles in diamond enable sensitive magnetometry. Many quantum-sensing protocols rely on reproducible target fields, allowing repeated measurements under different sensing conditions. In dynamical decoupling (DD) magnetometry, sweeping the interval between πππ pulses across repeated measurements enables estimation of the frequency and amplitude of an unknown alternating field. For non-repeatable events, however, the same field waveform cannot be reproduced for measurements under different settings. Here we propose NV-based in-sensor quantum reservoir computing (NV-QRC) for sensing such events. Field-driven many-body dynamics and simultaneous fluorescence readout from multiple spatial regions provide a classical classifier with multiple features from a single event. For binary phase classification, we benchmark NV-QRC against DD magnetometry using a single pulse sequence fixed in advance. We show that NV-QRC can retain class-dependent information in regimes where the fixed-DD protocol fails to capture it. These results identify non-repeatable-event sensing as a promising application of quantum reservoir computing.