arXiv:2610.13153
Continuous-wave AC magnetometry up to hundreds of megahertz using nitrogen-vacancy centers under a strong transverse magnetic field
Ryusei Okaniwa, Rui Suzuki, Yuichiro Matsuzaki, Norio Tokuda, Junko Ishi-Hayase
Abstract
Nitrogen-vacancy (NV) centers in diamond are promising quantum sensors for AC magnetic fields. However, conventional dynamical-decoupling-based magnetometry becomes technically demanding at high frequencies because of the requirement for increasingly short and high-power microwave pulses. This paper describes an AC magnetometry technique based on continuous-wave optically detected magnetic resonance (CW-ODMR) measurements, which enables the detection of signals in the hundred-MHz range. By applying a strong static magnetic field transverse to the NV axis, the energy separation between the relevant electron-spin states was tuned and resonantly coupled with the target radiofrequency (RF) magnetic field, thereby forming RF-dressed states. Unlike pulsed dynamical-decoupling schemes, this approach does not require high-power microwave pulse sequences. The key feature of our method is that the detectable frequency can be tuned by controlling the bias magnetic field strength. Using this methodology, we have experimentally achieved the frequency-tunable detection of AC magnetic fields from 14.4-632 MHz. The sensitivity was 0.558 uT/Hz^(0.5) at 14.4 MHz and 24.4 uT/Hz^(0.5) at 632 MHz. We characterized the field-dependent ODMR contrast and linewidth, and found that their degradation at large transverse fields is a important factor limiting the high-frequency sensitivity. These results establish a simple CW-ODMR approach for widely tunable RF magnetic-field sensing without high-power pulsed spin control.
AI Summary
Conventional dynamical-decoupling NV magnetometry requires increasingly short, high-power microwave pulses at high signal frequencies. This paper investigates whether continuous-wave optically detected magnetic resonance (CW-ODMR) can instead detect axial RF magnetic fields over a broadly tunable frequency range. A static magnetic field transverse to the NV axis mixes the ground-state spin levels and tunes the splitting between two RF-coupled states. A resonant target RF field produces dressed states, whose microwave resonance splitting depends on the RF amplitude. Experiments use a preferentially aligned NV ensemble, permanent-magnet bias control, and confocal fluorescence readout. ODMR transition frequencies establish tuning from $14.4$ to $632\,\mathrm{MHz}$; RF-amplitude-dependent spectra show dressed-state splitting, including a demonstration near $237\,\mathrm{MHz}$. Sensitivity is estimated from fluorescence noise and the slope of fluorescence versus RF amplitude at a fixed microwave frequency. Reported values range from $0.558\,\mu\mathrm{T}/\sqrt{\mathrm{Hz}}$ at $14.4\,\mathrm{MHz}$ to $24.4\,\mu\mathrm{T}/\sqrt{\mathrm{Hz}}$ at $632\,\mathrm{MHz}$. The approximately 44-fold sensitivity degradation accompanies reduced ODMR contrast and broader linewidths at stronger transverse bias. For the sensing transition, contrast decreases roughly sixfold and linewidth increases roughly 3.5-fold. Spin mixing and increased susceptibility to transverse magnetic noise are discussed as contributing mechanisms, but no complete quantitative noise decomposition is provided. The nonmonotonic fluorescence response at weak RF amplitudes is explained only qualitatively. Available bias fields limit the demonstrated range; diminishing contrast is expected to constrain further extension. Wide-field imaging compatibility and proposed sensitivity improvements are not demonstrated.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.
- Comments
- 15 pages, 6 figures, submit to Applied Physics Letters