arXiv:1601.07379 · Optics Letters

Absolute calibration of an EMCCD camera by quantum correlation, linking photon counting to the analog regime

Alessio Avella, Ivano Ruo Berchera, Ivo Pietro Degiovanni, G. Brida, Marco Genovese

Published Apr 12, 2016• 58 citations
arXivHTMLPDF

Abstract

We show how the same setup and procedure, exploiting spatially multimode quantum correlations, allows the absolute calibration of an electron-multiplying charge-coupled (EMCCD) camera from the analog regime down to the single-photon-counting level, just by adjusting the brightness of the quantum source. At the single-photon level, an EMCCD can be operated as an on-off detector, where quantum efficiency depends on the discriminating threshold. We develop a simple model to explain the connection of the two different regimes demonstrating that the efficiency estimated in the analog (bright) regime allows us to accurately predict the detector behavior in the photocounting regime and vice versa. This work establishes a bridge between two regions of the optical measurements that up to now have been based on completely different standards, detectors, and measurement techniques.

DOI
10.1364/ol.41.001841

Related papers

Imaging with Electron Multiplying Charge Coupled Devices (EMCCDs) in photon-counting regime : a proven tool for measurement of quantum features of light

F. Devaux

In the field of quantum optics, imaging started with single-point detectors scanning image planes to reconstruct quantumspatial features of light. At the early 2000's the emergence of commercially available Electron Multiplying Charge-CoupledDevices (EMCCD) detectors arrays, that are sensitive to single photons, have tremendously enlarged the perspective ofquantum imaging. From the first use of EMCCD for quantum imaging up to now, this device has become a proven andessential tool for future applications of quantum imaging to massive parallel processing of quantum information. Based onhis experience and activities, regarding the use of EMCCD cameras in quantum imaging, the author will presentthe method and advantages of using EMCCD cameras in single-photon counting mode.

•Sep 20, 2019•0 citations

Examining the effectiveness of increasing EMCCD EM gain beyond standard manufacturer limits in determining photon pair correlations

Kieran A. Roberts, Thomas Gregory, Miles J. Padgett

Electron multiplying charge coupled device (EMCCD) cameras are widely used for single-photon detection in various quantum optics applications. For example, these EMCCD cameras have been extensively used to measure the position and momentum correlations between photon pairs produced by parametric down-conversion in the image and far-field planes of the down-conversion crystal, respectively. The camera's operating parameters are typically set to balance a high quantum efficiency while simultaneously maintaining a low number of erroneous photon detections, the latter being mainly attributable to clock-induced charge (CIC) events in the readout register. The visibility of the measured correlations is an indication of the quantum efficiency of detecting the photon pairs versus the prevalence of the unwanted CIC. In this work, we show that this correlation visibility can be enhanced by operating the EMCCD camera with the electron multiplying (EM) gain set well in excess of its standard operating conditions. This enhancement will be of interest to those using EMCCD detectors in quantum imaging, sensing and processing applications.

Optics Express•Jul 22, 2025•0 citations

Absolute calibration of an analog InSb detector based on multimode spatial correlation of correlated photons

Xia Maopeng, Jianjun Li, Gao Dongyang +4 more

Absolute calibration can be realized by means of correlation photon which is generated by the parametric down conversion. The main difficulty lies in obtaining correlation information about photon flux when this method is applied to analog detector calibration process. A novel method of processing the photocurrent on the basis of detecting multimode spatial correlation is proposed. By converting the charge quantity contained in the photocurrent detected in a certain time interval into the photon counting, and by using double channels balance detection and measuring mean photon counts of each model to correct the dual channels fluctuations, the high accuracy calibration of quantum efficiency can be achieved. The photon fluxes of two channels are balanced by inserting an adjustable attenuator in one optical path. The cross section of pumping beam is comparable to the detection area to ensure three-wave colinearity, and the coherent area of the correlation photons is obtained by measuring pump beam waist and lens focus length. With the known detection area, coherence time and coherence area, the average photon number of each mode is computed. This process should be performed under the average photon number of each mode as a reference which could be used for the proportional scaling of equivalent photons of two channels. Based on this new approach, the absolute power responsivity of an InSb detector is calibrated at 3390 nm with correlated photon pairs at 631 and 3390 nm. The calibration procedure and experiments are described and the uncertainty of this method is analyzed. The results show a relative combination uncertainty of about 7.785% for this calibration method, which agrees well with the result independently obtained in the national photoelectronic metrology laboratory within a relative difference of about 3.6%. This result verifies that the quantum efficiency of an analog detector can be calibrated by the correlated photon method, which has potential applications in highly accurate radiometric calibration without external standards.

Acta Physica Sinica•Jan 1, 2015•1 citation

General Model of Photon-Pair Detection with an Image Sensor

Hugo Defienne, Matthew C. Reichert, Jason W. Fleischer

We develop an analytic model that relates intensity correlation measurements performed by an image sensor to the properties of photon pairs illuminating it. Experiments using an effective single-photon counting camera, a linear electron-multiplying charge-coupled device camera, and a standard CCD camera confirm the model. The results open the field of quantum optical sensing using conventional detectors.

arXiv:1801.09019•Physical Review Letters•May 17, 2018•85 citations

Absolute calibration of a charge-coupled device camera with twin beams

Alice Meda, Ivano Ruo Berchera, Ivo Pietro Degiovanni +3 more

We report on the absolute calibration of a Charge-Coupled Device (CCD) camera by exploiting quantum correlation. This method exploits a certain number of spatial pairwise quantum correlated modes produced by spontaneous parametric-down-conversion. We develop a measurement model accounting for all the uncertainty contributions, and we reach the relative uncertainty of 0.3% in low photon flux regime. This represents a significant step forward for the characterization of (scientific) CCDs used in mesoscopic light regime.

arXiv:1405.1526•Applied Physics Letters•Sep 8, 2014•30 citations

Full field measurement of spatial correlated photon pairs with an EMCCD camera

M. Edgar, D. S. Tasca, Frauke Izdebski +5 more

The spatial correlations between the photon pairs produced by spontaneous parametric down conversion (SPDC) have been investigated in a number of different configurations over the last two decades (1). The high dimensionality of the transverse spatial degrees of freedom (DOF) of the photon pairs can be explored either by projections onto a discrete (infinite) basis, such as the LG modes, or by using a continuous basis defined by the transverse position or momentum of the photons. For instance, it has been shown that their transverse position and momentum display EPR-type correlations (2). Despite the continuous and unbounded nature of both these bases, the most common measurements to date have relied upon the scanning of a single avalanche photodiode or a very small number of individual detectors. This sequential scanning or small number of detectors negates any information capacity advantage in the use of spatial states. Recent years have seen a rapid advance in imaging technologies, particularly for low light levels. Of these technologies the highest quantum efficiency is achieved using electron multiplying CCDs (EMCCD). Developments in low noise EMCCD cameras suggest they are capable of greater than 80% quantum efficiencies and if operated in an ultra-low light environment whilst being maintained at low temperatures, can provide single photon sensitivity (3). EMCCDs have been used in measurements of sub-shot-noise correlations of intensity fluctuations (4, 5) as well as in intensity correlations measurements (6) in the far field of the photon pairs from SPDC. Here we report the observation of spatial correlations from SPDC using an EMCCD camera in both the image and far-field planes of the down conversion crystal. We pump a BBO crystal at 355nm with a few milli-Watts of optical power and use a simple lens system to relay the down-converted light to an EMCCD array which can be positioned in either the image plane or the far-field of the crystal. Our photon flux is around 1/100 per pixel, which approximately doubles the signal obtained when the light is blocked. We typically record 100,000 individual frames and then sum the auto-correlation of the individual frames. We observed intensity correlation and anti-correlation in the image and far-field planes, respectively. In both cases we make the correlations more visible by subtracting a background which is obtained as the average correlation obtained between successive frames. Using this approach we are able to visualize the strength of the correlations in both position and momentum, showing a variance product nearly one order of magnitude below the classical limit in both x and y directions.

•Jan 1, 2012•0 citations
We show how the same setup and procedure, exploiting spatially multimode quantum correlations, allows the absolute calibration of an electron-multiplying charge-coupled (EMCCD) camera from the analog regime down to the single-photon-counting level, just by adjusting the brightness of the quantum source. At the single-photon level, an EMCCD can be operated as an on-off detector, where quantum efficiency depends on the discriminating threshold. We develop a simple model to explain the connection of the two different regimes demonstrating that the efficiency estimated in the analog (bright) regime allows us to accurately predict the detector behavior in the photocounting regime and vice versa. This work establishes a bridge between two regions of the optical measurements that up to now have been based on completely different standards, detectors, and measurement techniques.
In the field of quantum optics, imaging started with single-point detectors scanning image planes to reconstruct quantumspatial features of light. At the early 2000's the emergence of commercially available Electron Multiplying Charge-CoupledDevices (EMCCD) detectors arrays, that are sensitive to single photons, have tremendously enlarged the perspective ofquantum imaging. From the first use of EMCCD for quantum imaging up to now, this device has become a proven andessential tool for future applications of quantum imaging to massive parallel processing of quantum information. Based onhis experience and activities, regarding the use of EMCCD cameras in quantum imaging, the author will presentthe method and advantages of using EMCCD cameras in single-photon counting mode.
Electron multiplying charge coupled device (EMCCD) cameras are widely used for single-photon detection in various quantum optics applications. For example, these EMCCD cameras have been extensively used to measure the position and momentum correlations between photon pairs produced by parametric down-conversion in the image and far-field planes of the down-conversion crystal, respectively. The camera's operating parameters are typically set to balance a high quantum efficiency while simultaneously maintaining a low number of erroneous photon detections, the latter being mainly attributable to clock-induced charge (CIC) events in the readout register. The visibility of the measured correlations is an indication of the quantum efficiency of detecting the photon pairs versus the prevalence of the unwanted CIC. In this work, we show that this correlation visibility can be enhanced by operating the EMCCD camera with the electron multiplying (EM) gain set well in excess of its standard operating conditions. This enhancement will be of interest to those using EMCCD detectors in quantum imaging, sensing and processing applications.
Absolute calibration can be realized by means of correlation photon which is generated by the parametric down conversion. The main difficulty lies in obtaining correlation information about photon flux when this method is applied to analog detector calibration process. A novel method of processing the photocurrent on the basis of detecting multimode spatial correlation is proposed. By converting the charge quantity contained in the photocurrent detected in a certain time interval into the photon counting, and by using double channels balance detection and measuring mean photon counts of each model to correct the dual channels fluctuations, the high accuracy calibration of quantum efficiency can be achieved. The photon fluxes of two channels are balanced by inserting an adjustable attenuator in one optical path. The cross section of pumping beam is comparable to the detection area to ensure three-wave colinearity, and the coherent area of the correlation photons is obtained by measuring pump beam waist and lens focus length. With the known detection area, coherence time and coherence area, the average photon number of each mode is computed. This process should be performed under the average photon number of each mode as a reference which could be used for the proportional scaling of equivalent photons of two channels. Based on this new approach, the absolute power responsivity of an InSb detector is calibrated at 3390 nm with correlated photon pairs at 631 and 3390 nm. The calibration procedure and experiments are described and the uncertainty of this method is analyzed. The results show a relative combination uncertainty of about 7.785% for this calibration method, which agrees well with the result independently obtained in the national photoelectronic metrology laboratory within a relative difference of about 3.6%. This result verifies that the quantum efficiency of an analog detector can be calibrated by the correlated photon method, which has potential applications in highly accurate radiometric calibration without external standards.
We report on the absolute calibration of a Charge-Coupled Device (CCD) camera by exploiting quantum correlation. This method exploits a certain number of spatial pairwise quantum correlated modes produced by spontaneous parametric-down-conversion. We develop a measurement model accounting for all the uncertainty contributions, and we reach the relative uncertainty of 0.3% in low photon flux regime. This represents a significant step forward for the characterization of (scientific) CCDs used in mesoscopic light regime.
The spatial correlations between the photon pairs produced by spontaneous parametric down conversion (SPDC) have been investigated in a number of different configurations over the last two decades (1). The high dimensionality of the transverse spatial degrees of freedom (DOF) of the photon pairs can be explored either by projections onto a discrete (infinite) basis, such as the LG modes, or by using a continuous basis defined by the transverse position or momentum of the photons. For instance, it has been shown that their transverse position and momentum display EPR-type correlations (2). Despite the continuous and unbounded nature of both these bases, the most common measurements to date have relied upon the scanning of a single avalanche photodiode or a very small number of individual detectors. This sequential scanning or small number of detectors negates any information capacity advantage in the use of spatial states. Recent years have seen a rapid advance in imaging technologies, particularly for low light levels. Of these technologies the highest quantum efficiency is achieved using electron multiplying CCDs (EMCCD). Developments in low noise EMCCD cameras suggest they are capable of greater than 80% quantum efficiencies and if operated in an ultra-low light environment whilst being maintained at low temperatures, can provide single photon sensitivity (3). EMCCDs have been used in measurements of sub-shot-noise correlations of intensity fluctuations (4, 5) as well as in intensity correlations measurements (6) in the far field of the photon pairs from SPDC. Here we report the observation of spatial correlations from SPDC using an EMCCD camera in both the image and far-field planes of the down conversion crystal. We pump a BBO crystal at 355nm with a few milli-Watts of optical power and use a simple lens system to relay the down-converted light to an EMCCD array which can be positioned in either the image plane or the far-field of the crystal. Our photon flux is around 1/100 per pixel, which approximately doubles the signal obtained when the light is blocked. We typically record 100,000 individual frames and then sum the auto-correlation of the individual frames. We observed intensity correlation and anti-correlation in the image and far-field planes, respectively. In both cases we make the correlations more visible by subtracting a background which is obtained as the average correlation obtained between successive frames. Using this approach we are able to visualize the strength of the correlations in both position and momentum, showing a variance product nearly one order of magnitude below the classical limit in both x and y directions.