Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1504.04777 · Physical Review A

Weak-value amplification beyond the standard quantum limit in position measurements

A. Nishizawa

Published Sep 21, 2015• 11 citations
arXivHTMLPDF

Abstract

In a weak measurement with postselection, a measurement value, called the weak value, can be amplified beyond the eigenvalues of an observable. However, there are some controversies whether weak-value amplification is practically useful in increasing the sensitivity of the measurement, in which fundamental quantum noise dominates. In this paper, we investigate the sensitivity limit of an optical interferometer when weak-value amplification is implemented, properly accounting for quantum shot noise and radiation-pressure noise. To do so, we formulate weak-value amplification in the Heisenberg picture instead of in the Schr\"odinger picture, which is conventionally used. This formulation enables us to understand intuitively what happens when the measurement outcome is postselected and the weak value is amplified. As a result, we find that the sensitivity limit is given by the standard quantum limit that is the same as in a standard interferometry. We also discuss a way to circumvent the standard quantum limit.

DOI
10.1103/physreva.92.032123

Related papers

Weak-value amplification in a shot-noise-limited interferometer

A. Nishizawa, Kouji Nakamura, Masa‐Katsu Fujimoto

We study the weak-value amplification (WVA) in a phase measurement with an optical interferometer in which shot noise limits the sensitivity. We compute the signal and the shot noise including the full-order interaction terms of the WVA, and show that the shot-noise contribution to a phase shift in a pointer variable is always larger than the final variance of the pointer variable. This yields the difference in estimating the noise level up to a factor of 1.5. To clarify an advantage for practical uses of the WVA, we discuss the signal-to-noise ratio and its optimization in the presence of the shot noise.

arXiv:1201.6039•Physical Review A•Jun 11, 2012•51 citations

Enhanced Weak-Value Amplification via Photon Recycling

Courtney Krafczyk, Andrew N. Jordan, M. E. Goggin +1 more

In a quantum-noise limited system, weak-value amplification using postselection normally does not produce more sensitive measurements than standard methods for ideal detectors: the increased weak value is compensated by the reduced power due to the small postselection probability. Here, we experimentally demonstrate recycled weak-value measurements using a pulsed light source and optical switch to enable nearly deterministic weak-value amplification of a mirror tilt. Using photon counting detectors, we demonstrate a signal improvement by a factor of 4.4±0.2 and a signal-to-noise ratio improvement of 2.10±0.06, compared to a single-pass weak-value experiment, and also compared to a conventional direct measurement of the tilt. The signal-to-noise ratio improvement could reach around six for the parameters of this experiment, assuming lower loss elements.

arXiv:2104.14393•Physical Review Letters•Jun 1, 2021•43 citations

Implementation of weak measurement amplification with the weak coherent light and optomechanical system

Gang Li, Wen Yang

Abstract Most studies for postselected weak measurement in optomechanical system focus on using a single photon as a measured system. However, we find that using weak coherent light instead of a single photon can also amplify the mirror’s position displacement of one photon. In the weak value amplification (WVA) regime, the weak value of one photon can lie outside the eigenvalue spectrum, proportional to the difference of the mirror’s position displacement between the successful and failed postselection and its successful postselection probability is dependent of the mean photon number of the coherent light and improved by adjusting it accordingly. Outside the WVA regime, the amplification limit can reach the level of the vacuum fluctuations, and when the mean photon number and the optomechanical coupling parameter are selected appropriately, its successful postselection probability becomes higher, which is beneficial to observe the maximum amplification value under the current experimental conditions. This result breaks the constraint that it is difficult to detect outside the WVA regime. This opens up a new regime for the study of a single photon nonlinearity in optomechanical system.

arXiv:2104.03561•Journal of Physics B Atomic Molecular and Optical Physics•Jun 9, 2021•2 citations

Uncertainty control and precision enhancement of weak measurements in the quadratic regime

Bertúlio de Lima Bernardo, Weliton Soares Martins, Sérgio Azevedo +1 more

Weak-value amplification has been successfully used to amplify the sensitivity of small detector signals, which paved the way towards new developments for precise parameter estimation methods. In general, the scheme is based on the idea that, between pre- and postselection, the measured system and the pointer are coupled in such a way that the interaction depends linearly on the coupling constant, the so-called linear regime. In this article, we propose an improvement to this technique that is based on the quadratic regime of interaction to increase the precision of such measurements. We demonstrate that by employing a purely real (imaginary) weak value in this regime, it is possible to decrease considerably the standard deviation of the final pointer observable in the position (momentum) space, when compared to the traditional linear regime, rendering a precision enhancement. By using an all-optical implementation, we obtained experimental data that confirm our theoretical predictions.

Physical Review A•Jul 13, 2015•7 citations

Optimal Settings for Amplification and Estimation Of Small Effects In Postselected Ensembles

A. M. Rostom

Abstract To describe the pre‐ and postselected quantum ensembles, a complex quantity called the weak value of an operator is used. The weak value is highly controversial due to the fact that it is not bounded by the possible eigenvalues of the corresponding operator. Nevertheless, the obtaining of the anomalous weak value is regarded as a powerful technique in the quantum interferometry nowadays. Here it is shown that the postselection of a quantum system recovers a completely hidden interference effect in the measurement apparatus. Studying the interference pattern shows the optimal settings for the amplification and the parameter estimation. It also proves that the weak value is not an element of reality. Using single photons, it is investigated how a postselected photon can impart a π phase shift (the peak of the amplification) to a photon interacting weakly with it in a nonlinear optical medium. The increasing of the degree of the entanglement lies behind the effectiveness of the postselection in the parameter estimation. In particular, arranging to postselect on pure entangled states can optimize the signal‐to‐noise ratio, allowing to achieve high‐sensitive measurements using low input power.

arXiv:2303.09786•Annalen der Physik•Dec 2, 2021•5 citations

Transfer of Fisher information in quantum postselection metrology

Zi-Rui Zhong, Ke-Xuan Chen, Xia-Lin Su +4 more

Abstract Postselected weak measurement has shown significant potential for detecting small physical effects due to its unique weak-value-amplification phenomenon. Previous works suggest that Heisenberg-limit precision can be attained using optical coherent states. However, the observed Heisenberg scaling requires a measurement of the distribution of postselection probability, exhibiting no implementation pathway through conventional measurement paradigms. Here, we demonstrate that the output photons can also reach the Heisenberg scale by utilizing the Fisher information transfer effect, while this scenario exhibits enhanced robustness against dephasing noise. In addition, we consider the insertion of a power-recycling cavity and demonstrate its positive impact on the distribution of postselection. Our results enhance the quantum metrological advantages of the postselection strategy and broaden its application scope.

arXiv:2412.04838•Chinese Physics B•Oct 30, 2025•2 citations
In a weak measurement with postselection, a measurement value, called the weak value, can be amplified beyond the eigenvalues of an observable. However, there are some controversies whether weak-value amplification is practically useful in increasing the sensitivity of the measurement, in which fundamental quantum noise dominates. In this paper, we investigate the sensitivity limit of an optical interferometer when weak-value amplification is implemented, properly accounting for quantum shot noise and radiation-pressure noise. To do so, we formulate weak-value amplification in the Heisenberg picture instead of in the Schr"odinger picture, which is conventionally used. This formulation enables us to understand intuitively what happens when the measurement outcome is postselected and the weak value is amplified. As a result, we find that the sensitivity limit is given by the standard quantum limit that is the same as in a standard interferometry. We also discuss a way to circumvent the standard quantum limit.
We study the weak-value amplification (WVA) in a phase measurement with an optical interferometer in which shot noise limits the sensitivity. We compute the signal and the shot noise including the full-order interaction terms of the WVA, and show that the shot-noise contribution to a phase shift in a pointer variable is always larger than the final variance of the pointer variable. This yields the difference in estimating the noise level up to a factor of 1.5. To clarify an advantage for practical uses of the WVA, we discuss the signal-to-noise ratio and its optimization in the presence of the shot noise.
In a quantum-noise limited system, weak-value amplification using postselection normally does not produce more sensitive measurements than standard methods for ideal detectors: the increased weak value is compensated by the reduced power due to the small postselection probability. Here, we experimentally demonstrate recycled weak-value measurements using a pulsed light source and optical switch to enable nearly deterministic weak-value amplification of a mirror tilt. Using photon counting detectors, we demonstrate a signal improvement by a factor of 4.4±0.2 and a signal-to-noise ratio improvement of 2.10±0.06, compared to a single-pass weak-value experiment, and also compared to a conventional direct measurement of the tilt. The signal-to-noise ratio improvement could reach around six for the parameters of this experiment, assuming lower loss elements.
Abstract Most studies for postselected weak measurement in optomechanical system focus on using a single photon as a measured system. However, we find that using weak coherent light instead of a single photon can also amplify the mirror’s position displacement of one photon. In the weak value amplification (WVA) regime, the weak value of one photon can lie outside the eigenvalue spectrum, proportional to the difference of the mirror’s position displacement between the successful and failed postselection and its successful postselection probability is dependent of the mean photon number of the coherent light and improved by adjusting it accordingly. Outside the WVA regime, the amplification limit can reach the level of the vacuum fluctuations, and when the mean photon number and the optomechanical coupling parameter are selected appropriately, its successful postselection probability becomes higher, which is beneficial to observe the maximum amplification value under the current experimental conditions. This result breaks the constraint that it is difficult to detect outside the WVA regime. This opens up a new regime for the study of a single photon nonlinearity in optomechanical system.
Weak-value amplification has been successfully used to amplify the sensitivity of small detector signals, which paved the way towards new developments for precise parameter estimation methods. In general, the scheme is based on the idea that, between pre- and postselection, the measured system and the pointer are coupled in such a way that the interaction depends linearly on the coupling constant, the so-called linear regime. In this article, we propose an improvement to this technique that is based on the quadratic regime of interaction to increase the precision of such measurements. We demonstrate that by employing a purely real (imaginary) weak value in this regime, it is possible to decrease considerably the standard deviation of the final pointer observable in the position (momentum) space, when compared to the traditional linear regime, rendering a precision enhancement. By using an all-optical implementation, we obtained experimental data that confirm our theoretical predictions.
Abstract To describe the pre‐ and postselected quantum ensembles, a complex quantity called the weak value of an operator is used. The weak value is highly controversial due to the fact that it is not bounded by the possible eigenvalues of the corresponding operator. Nevertheless, the obtaining of the anomalous weak value is regarded as a powerful technique in the quantum interferometry nowadays. Here it is shown that the postselection of a quantum system recovers a completely hidden interference effect in the measurement apparatus. Studying the interference pattern shows the optimal settings for the amplification and the parameter estimation. It also proves that the weak value is not an element of reality. Using single photons, it is investigated how a postselected photon can impart a π phase shift (the peak of the amplification) to a photon interacting weakly with it in a nonlinear optical medium. The increasing of the degree of the entanglement lies behind the effectiveness of the postselection in the parameter estimation. In particular, arranging to postselect on pure entangled states can optimize the signal‐to‐noise ratio, allowing to achieve high‐sensitive measurements using low input power.
Abstract Postselected weak measurement has shown significant potential for detecting small physical effects due to its unique weak-value-amplification phenomenon. Previous works suggest that Heisenberg-limit precision can be attained using optical coherent states. However, the observed Heisenberg scaling requires a measurement of the distribution of postselection probability, exhibiting no implementation pathway through conventional measurement paradigms. Here, we demonstrate that the output photons can also reach the Heisenberg scale by utilizing the Fisher information transfer effect, while this scenario exhibits enhanced robustness against dephasing noise. In addition, we consider the insertion of a power-recycling cavity and demonstrate its positive impact on the distribution of postselection. Our results enhance the quantum metrological advantages of the postselection strategy and broaden its application scope.