Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2303.09786 · Annalen der Physik

Optimal Settings for Amplification and Estimation Of Small Effects In Postselected Ensembles

A. M. Rostom

Published Dec 2, 2021• 5 citations
arXivHTMLPDF

Abstract

Abstract To describe the pre‐ and postselected quantum ensembles, a complex quantity called the weak value of an operator is used. The weak value is highly controversial due to the fact that it is not bounded by the possible eigenvalues of the corresponding operator. Nevertheless, the obtaining of the anomalous weak value is regarded as a powerful technique in the quantum interferometry nowadays. Here it is shown that the postselection of a quantum system recovers a completely hidden interference effect in the measurement apparatus. Studying the interference pattern shows the optimal settings for the amplification and the parameter estimation. It also proves that the weak value is not an element of reality. Using single photons, it is investigated how a postselected photon can impart a π phase shift (the peak of the amplification) to a photon interacting weakly with it in a nonlinear optical medium. The increasing of the degree of the entanglement lies behind the effectiveness of the postselection in the parameter estimation. In particular, arranging to postselect on pure entangled states can optimize the signal‐to‐noise ratio, allowing to achieve high‐sensitive measurements using low input power.

DOI
10.1002/andp.202100434

Related papers

Entanglement-Assisted Weak Value Amplification

Shengshi Pang, Justin Dressel, Todd A. Brun

Large weak values have been used to amplify the sensitivity of a linear response signal for detecting changes in a small parameter, which has also enabled a simple method for precise parameter estimation. However, producing a large weak value requires a low postselection probability for an ancilla degree of freedom, which limits the utility of the technique. We propose an improvement to this method that uses entanglement to increase the efficiency. We show that by entangling and postselecting n ancillas, the postselection probability can be increased by a factor of n while keeping the weak value fixed (compared to n uncorrelated attempts with one ancilla), which is the optimal scaling with n that is expected from quantum metrology. Furthermore, we show the surprising result that the quantum Fisher information about the detected parameter can be almost entirely preserved in the postselected state, which allows the sensitive estimation to approximately saturate the relevant quantum Cramér-Rao bound. To illustrate this protocol we provide simple quantum circuits that can be implemented using current experimental realizations of three entangled qubits.

arXiv:1401.5887•Physical Review Letters•Jul 15, 2014•109 citations

Weak Value Amplification is Suboptimal for Estimation and Detection

Christopher Ferrie, Joshua Combes

We show by using statistically rigorous arguments that the technique of weak value amplification does not perform better than standard statistical techniques for the tasks of single parameter estimation and signal detection. Specifically, we prove that postselection, a necessary ingredient for weak value amplification, decreases estimation accuracy and, moreover, arranging for anomalously large weak values is a suboptimal strategy. In doing so, we explicitly provide the optimal estimator, which in turn allows us to identify the optimal experimental arrangement to be the one in which all outcomes have equal weak values (all as small as possible) and the initial state of the meter is the maximal eigenvalue of the square of the system observable. Finally, we give precise quantitative conditions for when weak measurement (measurements without postselection or anomalously large weak values) can mitigate the effect of uncharacterized technical noise in estimation.

arXiv:1307.4016•Physical Review Letters•Jan 31, 2014•218 citations

Optimal Settings for Amplification and Estimation Of Small Effects In Postselected Ensembles (Ann. Phys. 1/2022)

A. M. Rostom

Quantum Ensembles As described by Aiham M. Rostom in article number 2100434, the cover image shows how a hidden interference pattern in A-interferometer can be recovered by the application of post-selection on the B-interferometer. Above the picture, a formula for a pure entangled state is written to point out that the pure entangled state is a key element in this phenomenon.

Annalen der Physik•Jan 1, 2022•1 citation

Weak Value Amplification of Photons in Optical Nonlinear Medium, Opto-Mechanical, and Spin-Mechanical Systems

Sergio Carrasco, Miguel Orszag

A measurement of an observable A performed on a quantum system that is initially prepared in a state ρi, followed by a probabilistic procedure that leaves the system in a final state ρf, a process often referred as state postselection (or filtering process), can yield, on average, anomalous measurement results, i.e., values that may exceed the eigenvalue range of the observable being measured or be complex numbers. There is, therefore, an amplification effect of the average measurement result, i.e., the effect of the system on the measurement device is increased. When the coupling between the system and the measurement device satisfies some weakness conditions, the amplification effect occurs due to the weak value of the operator A. In this article, the amplification effect due to the postselection process is reviewed, and theoretical proposals and experiments published in the recent literature on the field are commented on. The emphasis is made on interactions occurring in optical nonlinear media and opto-mechanical and spin-mechanical systems, in which the amplification of number operators takes place.

Photonics•Mar 23, 2024•2 citations

Can Anomalous Amplification be Attained without Postselection?

Julián Martínez-Rincón, Wei-Tao Liu, Gerardo I. Viza +1 more

We present a parameter estimation technique based on performing joint measurements of a weak interaction away from the weak-value-amplification approximation. Two detectors are used to collect full statistics of the correlations between two weakly entangled degrees of freedom. Without discarding of data, the protocol resembles the anomalous amplification of an imaginary-weak-value-like response. The amplification is induced in the difference signal of both detectors allowing robustness to different sources of technical noise, and offering in addition the advantages of balanced signals for precision metrology. All of the Fisher information about the parameter of interest is collected. A tunable phase controls the strength of the amplification response. We experimentally demonstrate the proposed technique by measuring polarization rotations in a linearly polarized laser pulse. We show that in the presence of technical noise the effective sensitivity and precision of a split detector is increased when compared to a conventional continuous-wave balanced detection technique.

arXiv:1509.04810•Physical Review Letters•Mar 9, 2016•42 citations

Weak-value amplification beyond the standard quantum limit in position measurements

A. Nishizawa

In a weak measurement with postselection, a measurement value, called the weak value, can be amplified beyond the eigenvalues of an observable. However, there are some controversies whether weak-value amplification is practically useful in increasing the sensitivity of the measurement, in which fundamental quantum noise dominates. In this paper, we investigate the sensitivity limit of an optical interferometer when weak-value amplification is implemented, properly accounting for quantum shot noise and radiation-pressure noise. To do so, we formulate weak-value amplification in the Heisenberg picture instead of in the Schr\"odinger picture, which is conventionally used. This formulation enables us to understand intuitively what happens when the measurement outcome is postselected and the weak value is amplified. As a result, we find that the sensitivity limit is given by the standard quantum limit that is the same as in a standard interferometry. We also discuss a way to circumvent the standard quantum limit.

arXiv:1504.04777•Physical Review A•Sep 21, 2015•11 citations
Abstract To describe the pre‐ and postselected quantum ensembles, a complex quantity called the weak value of an operator is used. The weak value is highly controversial due to the fact that it is not bounded by the possible eigenvalues of the corresponding operator. Nevertheless, the obtaining of the anomalous weak value is regarded as a powerful technique in the quantum interferometry nowadays. Here it is shown that the postselection of a quantum system recovers a completely hidden interference effect in the measurement apparatus. Studying the interference pattern shows the optimal settings for the amplification and the parameter estimation. It also proves that the weak value is not an element of reality. Using single photons, it is investigated how a postselected photon can impart a π phase shift (the peak of the amplification) to a photon interacting weakly with it in a nonlinear optical medium. The increasing of the degree of the entanglement lies behind the effectiveness of the postselection in the parameter estimation. In particular, arranging to postselect on pure entangled states can optimize the signal‐to‐noise ratio, allowing to achieve high‐sensitive measurements using low input power.
Large weak values have been used to amplify the sensitivity of a linear response signal for detecting changes in a small parameter, which has also enabled a simple method for precise parameter estimation. However, producing a large weak value requires a low postselection probability for an ancilla degree of freedom, which limits the utility of the technique. We propose an improvement to this method that uses entanglement to increase the efficiency. We show that by entangling and postselecting n ancillas, the postselection probability can be increased by a factor of n while keeping the weak value fixed (compared to n uncorrelated attempts with one ancilla), which is the optimal scaling with n that is expected from quantum metrology. Furthermore, we show the surprising result that the quantum Fisher information about the detected parameter can be almost entirely preserved in the postselected state, which allows the sensitive estimation to approximately saturate the relevant quantum Cramér-Rao bound. To illustrate this protocol we provide simple quantum circuits that can be implemented using current experimental realizations of three entangled qubits.
We show by using statistically rigorous arguments that the technique of weak value amplification does not perform better than standard statistical techniques for the tasks of single parameter estimation and signal detection. Specifically, we prove that postselection, a necessary ingredient for weak value amplification, decreases estimation accuracy and, moreover, arranging for anomalously large weak values is a suboptimal strategy. In doing so, we explicitly provide the optimal estimator, which in turn allows us to identify the optimal experimental arrangement to be the one in which all outcomes have equal weak values (all as small as possible) and the initial state of the meter is the maximal eigenvalue of the square of the system observable. Finally, we give precise quantitative conditions for when weak measurement (measurements without postselection or anomalously large weak values) can mitigate the effect of uncharacterized technical noise in estimation.
A measurement of an observable A performed on a quantum system that is initially prepared in a state ρi, followed by a probabilistic procedure that leaves the system in a final state ρf, a process often referred as state postselection (or filtering process), can yield, on average, anomalous measurement results, i.e., values that may exceed the eigenvalue range of the observable being measured or be complex numbers. There is, therefore, an amplification effect of the average measurement result, i.e., the effect of the system on the measurement device is increased. When the coupling between the system and the measurement device satisfies some weakness conditions, the amplification effect occurs due to the weak value of the operator A. In this article, the amplification effect due to the postselection process is reviewed, and theoretical proposals and experiments published in the recent literature on the field are commented on. The emphasis is made on interactions occurring in optical nonlinear media and opto-mechanical and spin-mechanical systems, in which the amplification of number operators takes place.
We present a parameter estimation technique based on performing joint measurements of a weak interaction away from the weak-value-amplification approximation. Two detectors are used to collect full statistics of the correlations between two weakly entangled degrees of freedom. Without discarding of data, the protocol resembles the anomalous amplification of an imaginary-weak-value-like response. The amplification is induced in the difference signal of both detectors allowing robustness to different sources of technical noise, and offering in addition the advantages of balanced signals for precision metrology. All of the Fisher information about the parameter of interest is collected. A tunable phase controls the strength of the amplification response. We experimentally demonstrate the proposed technique by measuring polarization rotations in a linearly polarized laser pulse. We show that in the presence of technical noise the effective sensitivity and precision of a split detector is increased when compared to a conventional continuous-wave balanced detection technique.
In a weak measurement with postselection, a measurement value, called the weak value, can be amplified beyond the eigenvalues of an observable. However, there are some controversies whether weak-value amplification is practically useful in increasing the sensitivity of the measurement, in which fundamental quantum noise dominates. In this paper, we investigate the sensitivity limit of an optical interferometer when weak-value amplification is implemented, properly accounting for quantum shot noise and radiation-pressure noise. To do so, we formulate weak-value amplification in the Heisenberg picture instead of in the Schr\"odinger picture, which is conventionally used. This formulation enables us to understand intuitively what happens when the measurement outcome is postselected and the weak value is amplified. As a result, we find that the sensitivity limit is given by the standard quantum limit that is the same as in a standard interferometry. We also discuss a way to circumvent the standard quantum limit.