arXiv:1009.4738 · Physical Review Letters

Charge Sensing Amplification via Weak Values Measurement

Oded Zilberberg, Alessandro Romito, Yuval Gefen

Published Feb 24, 2011• 75 citations
arXivHTMLPDF

Abstract

A protocol employing weak values (WVs) to obtain ultrasensitive amplification of weak signals in the context of a solid-state setup is proposed. We consider an Aharonov-Bohm interferometer where both the orbital and the spin degrees of freedom are weakly affected by the presence of an external charge to be detected. The interplay between the spin and the orbital WVs leads to a significant amplification even in the presence of finite temperature, voltage, and external noise.

DOI
10.1103/physrevlett.106.080405

Related papers

Amplification of Angular Rotations Using Weak Measurements

Omar S. Magaña‐Loaiza, Mohammad Mirhosseini, Brandon Rodenburg +1 more

We present a weak measurement protocol that permits a sensitive estimation of angular rotations based on the concept of weak-value amplification. The shift in the state of a pointer, in both angular position and the conjugate orbital angular momentum bases, is used to estimate angular rotations. This is done by an amplification of both the real and imaginary parts of the weak-value of a polarization operator that has been coupled to the pointer, which is a spatial mode, via a spin-orbit coupling. Our experiment demonstrates the first realization of weak-value amplification in the azimuthal degree of freedom. We have achieved effective amplification factors as large as 100, providing a sensitivity that is on par with more complicated methods that employ quantum states of light or extremely large values of orbital angular momentum.

arXiv:1312.2981•Physical Review Letters•May 21, 2014•223 citations

Tomography of Many-Body Weak Values: Mach-Zehnder Interferometry

Vadim Shpitalnik, Yuval Gefen, Alessandro Romito

We propose and study a weak value (WV) protocol in the context of a solid state setup, specifically, an electronic Mach-Zehnder interferometer. This is the first specific proposal to measure both the real and imaginary part (i.e., complete tomography) of a WV. We also analyze the manifestation of many-body physics in the WV to be measured, including finite temperature and shot-noise-like contributions.

arXiv:0805.2737•Physical Review Letters•Nov 24, 2008•36 citations

Weak-Values Metrological Techniques for Parameter Estimation

Julián Martínez-Rincón

Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.

•Jan 1, 2017•0 citations

Weak values in an electronic mach-zehnder interferometer

Alessandro Romito

In the Demonstration it is possible to choose whether to plot the charge's weak value, D2<Q2>S1(in units of the electron charge), as a function of the voltage bias (measured in μV), the phase difference, or the temperature (measured in mK). (The phase difference includes the Aharonov–Bohm flux and the phases of the transmission coefficients of both the quantum point contacts.) In all cases it is possible to control the other parameters, including the transparencies of both the quantum point contacts and the duration of the measurement (measured in nsec). In the upper panel of the Demonstration we also plot the upper bound for standard quantum average of the charge in arm 2 (the lower bound is obviously 0): the weak value is clearly beyond the marked bounds

•Oct 26, 2016•0 citations

Enhanced on-chip phase measurement by inverse weak value amplification

Meiting Song, John Steinmetz, Yi Zhang +4 more

Optical interferometry plays an essential role in precision metrology such as in gravitational wave detection, gyroscopes, and environmental sensing. Weak value amplification enables reaching the shot-noise-limit of sensitivity, which is difficult for most optical sensors, by amplifying the interferometric signal without amplifying certain technical noises. We implement a generalized form of weak value amplification on an integrated photonic platform with a multi-mode interferometer. Our results pave the way for a more sensitive, robust, and compact platform for measuring phase, which can be adapted to fields such as coherent communications and the quantum domain. In this work, we show a 7 dB signal enhancement in our weak value device over a standard Mach-Zehnder interferometer with equal detected optical power, as well as frequency measurements with 2 kHz sensitivity by adding a ring resonator.

Nature Communications•Oct 29, 2021•32 citations

Optimal probe wave function of weak-value amplification

Yuki Susa, Yutaka Shikano, Akio Hosoya

The weak measurement proposed by Aharonov and his colleagues extracts information about a physical quantity of the system by the postselection as shifts of the argument of the probe wave function. The more the postselected state is orthogonal to the preselected state, the larger the shift determined by the weak value becomes. Recently, the signal amplification by the weak measurement has been extensively studied. In the present work, we explicitly obtain the optimal probe wave function and the amplification factor for a given weak value, which is calculated from the experimental setup. It is shown that the amplification factor has no upper bound, in contrast to the Gaussian probe wave function, and that the amplified signal is sharp.

arXiv:1203.0827•Physical Review A•May 11, 2012•61 citations
A protocol employing weak values (WVs) to obtain ultrasensitive amplification of weak signals in the context of a solid-state setup is proposed. We consider an Aharonov-Bohm interferometer where both the orbital and the spin degrees of freedom are weakly affected by the presence of an external charge to be detected. The interplay between the spin and the orbital WVs leads to a significant amplification even in the presence of finite temperature, voltage, and external noise.
We present a weak measurement protocol that permits a sensitive estimation of angular rotations based on the concept of weak-value amplification. The shift in the state of a pointer, in both angular position and the conjugate orbital angular momentum bases, is used to estimate angular rotations. This is done by an amplification of both the real and imaginary parts of the weak-value of a polarization operator that has been coupled to the pointer, which is a spatial mode, via a spin-orbit coupling. Our experiment demonstrates the first realization of weak-value amplification in the azimuthal degree of freedom. We have achieved effective amplification factors as large as 100, providing a sensitivity that is on par with more complicated methods that employ quantum states of light or extremely large values of orbital angular momentum.
Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.
In the Demonstration it is possible to choose whether to plot the charge's weak value, D2<Q2>S1(in units of the electron charge), as a function of the voltage bias (measured in μV), the phase difference, or the temperature (measured in mK). (The phase difference includes the Aharonov–Bohm flux and the phases of the transmission coefficients of both the quantum point contacts.) In all cases it is possible to control the other parameters, including the transparencies of both the quantum point contacts and the duration of the measurement (measured in nsec). In the upper panel of the Demonstration we also plot the upper bound for standard quantum average of the charge in arm 2 (the lower bound is obviously 0): the weak value is clearly beyond the marked bounds
Optical interferometry plays an essential role in precision metrology such as in gravitational wave detection, gyroscopes, and environmental sensing. Weak value amplification enables reaching the shot-noise-limit of sensitivity, which is difficult for most optical sensors, by amplifying the interferometric signal without amplifying certain technical noises. We implement a generalized form of weak value amplification on an integrated photonic platform with a multi-mode interferometer. Our results pave the way for a more sensitive, robust, and compact platform for measuring phase, which can be adapted to fields such as coherent communications and the quantum domain. In this work, we show a 7 dB signal enhancement in our weak value device over a standard Mach-Zehnder interferometer with equal detected optical power, as well as frequency measurements with 2 kHz sensitivity by adding a ring resonator.
The weak measurement proposed by Aharonov and his colleagues extracts information about a physical quantity of the system by the postselection as shifts of the argument of the probe wave function. The more the postselected state is orthogonal to the preselected state, the larger the shift determined by the weak value becomes. Recently, the signal amplification by the weak measurement has been extensively studied. In the present work, we explicitly obtain the optimal probe wave function and the amplification factor for a given weak value, which is calculated from the experimental setup. It is shown that the amplification factor has no upper bound, in contrast to the Gaussian probe wave function, and that the amplified signal is sharp.