Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1203.0827 · Physical Review A

Optimal probe wave function of weak-value amplification

Yuki Susa, Yutaka Shikano, Akio Hosoya

Published May 11, 2012• 61 citations
arXivHTMLPDF

Abstract

The weak measurement proposed by Aharonov and his colleagues extracts information about a physical quantity of the system by the postselection as shifts of the argument of the probe wave function. The more the postselected state is orthogonal to the preselected state, the larger the shift determined by the weak value becomes. Recently, the signal amplification by the weak measurement has been extensively studied. In the present work, we explicitly obtain the optimal probe wave function and the amplification factor for a given weak value, which is calculated from the experimental setup. It is shown that the amplification factor has no upper bound, in contrast to the Gaussian probe wave function, and that the amplified signal is sharp.

DOI
10.1103/physreva.85.052110

Related papers

Weak measurements beyond the Aharonov-Albert-Vaidman formalism

Shengjun Wu, Yang Li

We extend the idea of weak measurements to the general case, provide a complete treatment, and obtain results for both the regime when the preselected and postselected states (PPS) are almost orthogonal and the regime when they are exactly orthogonal. We surprisingly find that for a fixed interaction strength, there may exist a maximum signal amplification and a corresponding optimum overlap of PPS to achieve it. For weak measurements in the orthogonal regime, we find interesting quantities that play the same role that weak values play in the nonorthogonal regime.

arXiv:1010.1155•Physical Review A•May 5, 2011•106 citations

On signal amplification via weak measurement

Yutaka Shikano

One of the practical applications of the weak measurement proposed by Aharonov and his colleague is the signal amplification, which is called the weak-value amplification. We show the probe wavefunction to maximize the shift basically derived in [Y. Susa, Y. Shikano and A. Hosoya, Phys. Rev. A 85, 052110 (2012).] while this mode is not the propagation mode in light.

AIP conference proceedings•Jan 1, 2014•2 citations

Weak-value amplification as an optimal metrological protocol

G. B. Alves, Bruno M. Escher, R. L. de Matos Filho +2 more

The implementation of weak-value amplification requires the pre- and postselection of states of a quantum system, followed by the observation of the response of the meter, which interacts weakly with the system. Data acquisition from the meter is conditioned to successful postselection events. Here we derive an optimal postselection procedure for estimating the coupling constant between system and meter and show that it leads both to weak-value amplification and to the saturation of the quantum Fisher information, under conditions fulfilled by all previously reported experiments on the amplification of weak signals. For most of the preselected states, full information on the coupling constant can be extracted from the meter data set alone, while for a small fraction of the space of preselected states, it must be obtained from the postselection statistics.

arXiv:1410.7415•Physical Review A•Jun 8, 2015•56 citations

Weak Value Amplification is Suboptimal for Estimation and Detection

Christopher Ferrie, Joshua Combes

We show by using statistically rigorous arguments that the technique of weak value amplification does not perform better than standard statistical techniques for the tasks of single parameter estimation and signal detection. Specifically, we prove that postselection, a necessary ingredient for weak value amplification, decreases estimation accuracy and, moreover, arranging for anomalously large weak values is a suboptimal strategy. In doing so, we explicitly provide the optimal estimator, which in turn allows us to identify the optimal experimental arrangement to be the one in which all outcomes have equal weak values (all as small as possible) and the initial state of the meter is the maximal eigenvalue of the square of the system observable. Finally, we give precise quantitative conditions for when weak measurement (measurements without postselection or anomalously large weak values) can mitigate the effect of uncharacterized technical noise in estimation.

arXiv:1307.4016•Physical Review Letters•Jan 31, 2014•218 citations

Limits on amplification by Aharonov-Albert-Vaidman weak measurement

Tatsuhiko Koike, Saki Tanaka

We analyze the amplification by the Aharonov-Albert-Vaidman weak quantum measurement on a Sagnac interferometer [Dixon et al., Phys. Rev. Lett. 102, 173601 (2009)] up to all orders of the coupling strength between the measured system and the measuring device. The amplifier transforms a small tilt of a mirror into a large transverse displacement of the laser beam. The conventional analysis has shown that the measured value is proportional to the weak value, so that the amplification can be made arbitrarily large in the cost of decreasing output laser intensity. It is shown that the measured displacement and the amplification factor are in fact not proportional to the weak value and rather vanish in the limit of infinitesimal output intensity. We derive the optimal overlap of the pre- and postselected states with which the amplification become maximum. We also show that the nonlinear effects begin to arise in the performed experiments so that any improvements in the experiment, typically with an amplification greater than 100, should require the nonlinear theory in translating the observed value to the original displacement.

arXiv:1108.2050•Physical Review A•Dec 5, 2011•60 citations

Autocorrelative weak-value amplification and simulating the protocol under strong Gaussian noise

Jing-Hui Huang, Xiangyun Hu, Adetunmise C. Dada +4 more

By choosing more orthogonality between preselection and postselection states, one can significantly improve the sensitivity in general optical quantum metrology based on the weak-value amplification (WVA) approach. However, increasing the orthogonality decreases the probability of detecting photons and makes the weak measurement difficult, especially when the weak measurement is disturbed by strong noise and the pointer is drowned in noise with a negative-decibel signal-to-noise ratio (SNR). In this article we introduce and numerically evaluate a modified weak-measurement protocol with a temporal pointer, namely, the autocorrelative weak-value amplification (AWVA) approach. Specifically, a small longitudinal time delay (tiny phase shift) $\ensuremath{\tau}$ of a Gaussian pulse is measured by implementing two simultaneous autocorrelative weak measurements under Gaussian white noise with different SNRs. The small quantities $\ensuremath{\tau}$ are obtained by measuring the autocorrelation coefficient of the pulses instead of fitting the shift of the mean value of the probe in the standard WVA technique. Simulation results show that the AWVA approach outperforms the standard WVA technique in the time domain with smaller statistical errors, remarkably increasing the precision of weak measurement under a strong noise background.

arXiv:2203.15231•Physical Review A•Nov 3, 2022•9 citations
The weak measurement proposed by Aharonov and his colleagues extracts information about a physical quantity of the system by the postselection as shifts of the argument of the probe wave function. The more the postselected state is orthogonal to the preselected state, the larger the shift determined by the weak value becomes. Recently, the signal amplification by the weak measurement has been extensively studied. In the present work, we explicitly obtain the optimal probe wave function and the amplification factor for a given weak value, which is calculated from the experimental setup. It is shown that the amplification factor has no upper bound, in contrast to the Gaussian probe wave function, and that the amplified signal is sharp.
We extend the idea of weak measurements to the general case, provide a complete treatment, and obtain results for both the regime when the preselected and postselected states (PPS) are almost orthogonal and the regime when they are exactly orthogonal. We surprisingly find that for a fixed interaction strength, there may exist a maximum signal amplification and a corresponding optimum overlap of PPS to achieve it. For weak measurements in the orthogonal regime, we find interesting quantities that play the same role that weak values play in the nonorthogonal regime.
The implementation of weak-value amplification requires the pre- and postselection of states of a quantum system, followed by the observation of the response of the meter, which interacts weakly with the system. Data acquisition from the meter is conditioned to successful postselection events. Here we derive an optimal postselection procedure for estimating the coupling constant between system and meter and show that it leads both to weak-value amplification and to the saturation of the quantum Fisher information, under conditions fulfilled by all previously reported experiments on the amplification of weak signals. For most of the preselected states, full information on the coupling constant can be extracted from the meter data set alone, while for a small fraction of the space of preselected states, it must be obtained from the postselection statistics.
We show by using statistically rigorous arguments that the technique of weak value amplification does not perform better than standard statistical techniques for the tasks of single parameter estimation and signal detection. Specifically, we prove that postselection, a necessary ingredient for weak value amplification, decreases estimation accuracy and, moreover, arranging for anomalously large weak values is a suboptimal strategy. In doing so, we explicitly provide the optimal estimator, which in turn allows us to identify the optimal experimental arrangement to be the one in which all outcomes have equal weak values (all as small as possible) and the initial state of the meter is the maximal eigenvalue of the square of the system observable. Finally, we give precise quantitative conditions for when weak measurement (measurements without postselection or anomalously large weak values) can mitigate the effect of uncharacterized technical noise in estimation.
We analyze the amplification by the Aharonov-Albert-Vaidman weak quantum measurement on a Sagnac interferometer [Dixon et al., Phys. Rev. Lett. 102, 173601 (2009)] up to all orders of the coupling strength between the measured system and the measuring device. The amplifier transforms a small tilt of a mirror into a large transverse displacement of the laser beam. The conventional analysis has shown that the measured value is proportional to the weak value, so that the amplification can be made arbitrarily large in the cost of decreasing output laser intensity. It is shown that the measured displacement and the amplification factor are in fact not proportional to the weak value and rather vanish in the limit of infinitesimal output intensity. We derive the optimal overlap of the pre- and postselected states with which the amplification become maximum. We also show that the nonlinear effects begin to arise in the performed experiments so that any improvements in the experiment, typically with an amplification greater than 100, should require the nonlinear theory in translating the observed value to the original displacement.
By choosing more orthogonality between preselection and postselection states, one can significantly improve the sensitivity in general optical quantum metrology based on the weak-value amplification (WVA) approach. However, increasing the orthogonality decreases the probability of detecting photons and makes the weak measurement difficult, especially when the weak measurement is disturbed by strong noise and the pointer is drowned in noise with a negative-decibel signal-to-noise ratio (SNR). In this article we introduce and numerically evaluate a modified weak-measurement protocol with a temporal pointer, namely, the autocorrelative weak-value amplification (AWVA) approach. Specifically, a small longitudinal time delay (tiny phase shift) $\ensuremath{\tau}$ of a Gaussian pulse is measured by implementing two simultaneous autocorrelative weak measurements under Gaussian white noise with different SNRs. The small quantities $\ensuremath{\tau}$ are obtained by measuring the autocorrelation coefficient of the pulses instead of fitting the shift of the mean value of the probe in the standard WVA technique. Simulation results show that the AWVA approach outperforms the standard WVA technique in the time domain with smaller statistical errors, remarkably increasing the precision of weak measurement under a strong noise background.