arXiv:0902.1695 · Journal of Physics B Atomic Molecular and Optical Physics

How can a 22-pole ion trap exhibit ten local minima in the effective potential?

Rico Otto, P. Hlavenka, Sebastian H. Trippel, Jochen Mikosch, Kilian Singer, Matthias Weidemüller, Roland Wester

Published Jul 15, 2009• 38 citations
arXivHTMLPDF

Abstract

The column density distribution of trapped OH − ions in a 22-pole ion trap is measured for different trap parameters. The density is obtained from position-dependent photodetachment rate measurements. Overall, agreement is found with the effective potential of an ideal 22-pole. However, in addition, we observe ten distinct minima in the trapping potential, which indicate a breaking of the 22-fold symmetry. Numerical simulations show that a displacement of a subset of the radiofrequency electrodes can serve as an explanation for this symmetry breaking.

DOI
10.1088/0953-4075/42/15/154007

Related papers

Photodetachment of Cold OH− in a Multipole Ion Trap

Sebastian H. Trippel, Jochen Mikosch, R. Berhane +3 more

The absolute photodetachment cross section of OH- anions at a rotational and translational temperature of 170 K is determined by measuring the detachment-induced decay rate of the anions in a multipole radio-frequency ion trap. In comparison with previous results, the obtained cross section shows the importance of the initial rotational-state distribution. Using a tomography scan of the photodetachment laser through the trapped ion cloud, the derived cross section is model-independent and thus features a small systematic uncertainty. The tomography also yields the column density of the OH- anions in the 22-pole ion trap in good agreement with the expected trapping potential of a large field free region bound by steep potential walls.

arXiv:physics/0607248•Physical Review Letters•Nov 10, 2006•68 citations

Symmetry breaking in linear multipole traps

J. Pedregosa-Gutierrez, C. Champenois, Marius Romuald Kamsap +3 more

Radiofrequency multipole traps have been used for some decades in cold collision experiments and are gaining interest for precision spectroscopy due to their low micromotion contribution and the predicted unusual cold-ion structures. However, the experimental realisation is not yet fully controlled, and open questions in the operation of these devices remain. We present experimental observations of symmetry breaking of the trapping potential in a macroscopic octupole trap with laser-cooled ions. Numerical simulations have been performed in order to explain the appearance of additional local potential minima and be able to control them in a next step. We characterise these additional potential minima, in particular with respect to their position, their potential depth and their probability of population as a function of the radial and angular displacement of the trapping rods.

arXiv:1705.08133•Journal of Modern Optics•Dec 7, 2017•15 citations

An analytical approach to symmetry breaking in multipole RF-traps

Marylise Marchenay, J. Pedregosa-Gutierrez, Martina Knoop +2 more

Abstract Radio-frequency (RF) linear multipole traps have been shown to be very sensitive to mis-positioning of their electrodes, which results in a symmetry breaking and leads to extra local minima in the trapping potential as shown in Pedregosa-Gutierrez et al (2018 J. Mod. Opt. 65 529) disturbing the operation of the trap. In this work, we analytically describe the RF-potential of a realistic octupole trap by including lower order terms to the well-established equation for a perfectly symmetric octupole trap. We describe the geometry by a combination of identified defects, characterized by simple analytical expressions. A complete equation is proposed for a trap with any electrode deviation relying on a combination of the simple cases where the defects are taken individually. Our approach is validated by comparison between analytical and numerical results for defect sizes up to 4% of the trap radius. As described in Pedregosa-Gutierrez et al (2018 Rev. Sci. Instrum. 89 123101), an independent fine-tuning of the amplitude of the RF voltage applied on each electrode can be used to mitigate the geometrical defects of a realistic trap. In a different way than in Pedregosa-Gutierrez et al (2018 Rev. Sci. Instrum. 89 123101), the knowledge of an analytical equation for the potential allows to design the set of RF-voltages required for this compensation, based on the experimental measurement of the ion positions in the trap, without information concerning the exact position of each electrode, and with a small number of iterations. The requirements, performances and limitations of this protocol are discussed via comparison of numerical simulations and analytical results.

arXiv:2012.08198•Quantum Science and Technology•Mar 1, 2021•5 citations

Radiofrequency multipole traps: tools for spectroscopy and dynamics of cold molecular ions

Roland Wester

Multipole radiofrequency ion traps are a highly versatile tool to study molecular ions and their interactions in a well-controllable environment.In particular the cryogenic 22-pole ion trap configuration is used to study ion-molecule reactions and complex molecular spectroscopy at temperatures between a few kelvin and room temperatures.This paper presents a tutorial on radiofrequency ion trapping in multipole electrode configurations.Stable trapping conditions and buffer gas cooling, as well as important heating mechanisms, are discussed.In addition, selected experimental studies on cation and anion-molecule reactions and on spectroscopy of trapped ions are reviewed.Starting from these studies an outlook on the future of multipole ion trap research is given.

arXiv:0902.0475•Journal of Physics B Atomic Molecular and Optical Physics•Jul 15, 2009•160 citations

Internal state thermometry of cold trapped molecular anions

Rico Otto, Alexander von Zastrow, Thorsten Best +1 more

Photodetachment spectroscopy of OH(-) and H(3)O(2)(-) anions has been performed in a cryogenic 22-pole radiofrequency multipole trap. Measurements of the detachment cross section as a function of laser frequency near threshold have been analysed. Using this bound-free spectroscopy approach we could demonstrate rotational and vibrational cooling of the trapped anions by the buffer gas in the multipole trap. Below 50 K the OH(-) rotational temperature shows deviations from the buffer gas temperature, and possible causes for this are discussed. For H(3)O(2)(-) vibrational cooling of the lowest vibrational quantum states into the vibrational ground state is observed. Its photodetachment cross section near threshold is modelled with a Franck-Condon model, with a detachment threshold that is lower, but still in agreement with the expected threshold for this system.

arXiv:1408.4968•Physical Chemistry Chemical Physics•Nov 7, 2012•59 citations

Evaporation of trapped anions studied with a 22-pole ion trap in tandem time-of-flight configuration

Jochen Mikosch, Ulrike Frühling, Sebastian H. Trippel +5 more

We have recently shown [J. Mikosch et al., Phys. Rev. Lett. 98, 223001 (2007)] that the storage time of a thermal ensemble of ions in a multipole radiofrequency (rf) ion trap is ultimately limited by ion evaporation. An analysis of the evaporation rate was used to determine an effective trap depth as a function of the rf amplitude. This revealed that already for moderate rf amplitudes and low average stability parameter $\ensuremath{\eta}$ the loss of ions is driven by nonadiabatic motion of the fastest ions in the rf field. Here we present the details of the experimental procedure together with our experimental apparatus, which combines a 22-pole rf ion trap with tandem time-of-flight mass spectrometry for ion selection and product analysis. We furthermore describe in detail the numerical and analytical models used in the interpretation of our results, which allows one to predict the most favorable trapping conditions in multipole rf ion traps. From a fit to our data we obtain a maximal value of the multipole stability parameter of ${\ensuremath{\eta}}_{\mathit{max}}=0.36\ifmmode\pm\else\textpm\fi{}0.02$ for adiabatic ion motion.

Physical Review A•Aug 6, 2008•40 citations
The column density distribution of trapped OH − ions in a 22-pole ion trap is measured for different trap parameters. The density is obtained from position-dependent photodetachment rate measurements. Overall, agreement is found with the effective potential of an ideal 22-pole. However, in addition, we observe ten distinct minima in the trapping potential, which indicate a breaking of the 22-fold symmetry. Numerical simulations show that a displacement of a subset of the radiofrequency electrodes can serve as an explanation for this symmetry breaking.
The absolute photodetachment cross section of OH- anions at a rotational and translational temperature of 170 K is determined by measuring the detachment-induced decay rate of the anions in a multipole radio-frequency ion trap. In comparison with previous results, the obtained cross section shows the importance of the initial rotational-state distribution. Using a tomography scan of the photodetachment laser through the trapped ion cloud, the derived cross section is model-independent and thus features a small systematic uncertainty. The tomography also yields the column density of the OH- anions in the 22-pole ion trap in good agreement with the expected trapping potential of a large field free region bound by steep potential walls.
Radiofrequency multipole traps have been used for some decades in cold collision experiments and are gaining interest for precision spectroscopy due to their low micromotion contribution and the predicted unusual cold-ion structures. However, the experimental realisation is not yet fully controlled, and open questions in the operation of these devices remain. We present experimental observations of symmetry breaking of the trapping potential in a macroscopic octupole trap with laser-cooled ions. Numerical simulations have been performed in order to explain the appearance of additional local potential minima and be able to control them in a next step. We characterise these additional potential minima, in particular with respect to their position, their potential depth and their probability of population as a function of the radial and angular displacement of the trapping rods.
Abstract Radio-frequency (RF) linear multipole traps have been shown to be very sensitive to mis-positioning of their electrodes, which results in a symmetry breaking and leads to extra local minima in the trapping potential as shown in Pedregosa-Gutierrez et al (2018 J. Mod. Opt. 65 529) disturbing the operation of the trap. In this work, we analytically describe the RF-potential of a realistic octupole trap by including lower order terms to the well-established equation for a perfectly symmetric octupole trap. We describe the geometry by a combination of identified defects, characterized by simple analytical expressions. A complete equation is proposed for a trap with any electrode deviation relying on a combination of the simple cases where the defects are taken individually. Our approach is validated by comparison between analytical and numerical results for defect sizes up to 4% of the trap radius. As described in Pedregosa-Gutierrez et al (2018 Rev. Sci. Instrum. 89 123101), an independent fine-tuning of the amplitude of the RF voltage applied on each electrode can be used to mitigate the geometrical defects of a realistic trap. In a different way than in Pedregosa-Gutierrez et al (2018 Rev. Sci. Instrum. 89 123101), the knowledge of an analytical equation for the potential allows to design the set of RF-voltages required for this compensation, based on the experimental measurement of the ion positions in the trap, without information concerning the exact position of each electrode, and with a small number of iterations. The requirements, performances and limitations of this protocol are discussed via comparison of numerical simulations and analytical results.
Multipole radiofrequency ion traps are a highly versatile tool to study molecular ions and their interactions in a well-controllable environment.In particular the cryogenic 22-pole ion trap configuration is used to study ion-molecule reactions and complex molecular spectroscopy at temperatures between a few kelvin and room temperatures.This paper presents a tutorial on radiofrequency ion trapping in multipole electrode configurations.Stable trapping conditions and buffer gas cooling, as well as important heating mechanisms, are discussed.In addition, selected experimental studies on cation and anion-molecule reactions and on spectroscopy of trapped ions are reviewed.Starting from these studies an outlook on the future of multipole ion trap research is given.
Photodetachment spectroscopy of OH(-) and H(3)O(2)(-) anions has been performed in a cryogenic 22-pole radiofrequency multipole trap. Measurements of the detachment cross section as a function of laser frequency near threshold have been analysed. Using this bound-free spectroscopy approach we could demonstrate rotational and vibrational cooling of the trapped anions by the buffer gas in the multipole trap. Below 50 K the OH(-) rotational temperature shows deviations from the buffer gas temperature, and possible causes for this are discussed. For H(3)O(2)(-) vibrational cooling of the lowest vibrational quantum states into the vibrational ground state is observed. Its photodetachment cross section near threshold is modelled with a Franck-Condon model, with a detachment threshold that is lower, but still in agreement with the expected threshold for this system.
We have recently shown [J. Mikosch et al., Phys. Rev. Lett. 98, 223001 (2007)] that the storage time of a thermal ensemble of ions in a multipole radiofrequency (rf) ion trap is ultimately limited by ion evaporation. An analysis of the evaporation rate was used to determine an effective trap depth as a function of the rf amplitude. This revealed that already for moderate rf amplitudes and low average stability parameter $\ensuremath{\eta}$ the loss of ions is driven by nonadiabatic motion of the fastest ions in the rf field. Here we present the details of the experimental procedure together with our experimental apparatus, which combines a 22-pole rf ion trap with tandem time-of-flight mass spectrometry for ion selection and product analysis. We furthermore describe in detail the numerical and analytical models used in the interpretation of our results, which allows one to predict the most favorable trapping conditions in multipole rf ion traps. From a fit to our data we obtain a maximal value of the multipole stability parameter of ${\ensuremath{\eta}}_{\mathit{max}}=0.36\ifmmode\pm\else\textpm\fi{}0.02$ for adiabatic ion motion.