arXiv:1408.4968 · Physical Chemistry Chemical Physics

Internal state thermometry of cold trapped molecular anions

Rico Otto, Alexander von Zastrow, Thorsten Best, Roland Wester

Published Nov 7, 2012• 59 citations
arXivHTMLPDF

Abstract

Photodetachment spectroscopy of OH(-) and H(3)O(2)(-) anions has been performed in a cryogenic 22-pole radiofrequency multipole trap. Measurements of the detachment cross section as a function of laser frequency near threshold have been analysed. Using this bound-free spectroscopy approach we could demonstrate rotational and vibrational cooling of the trapped anions by the buffer gas in the multipole trap. Below 50 K the OH(-) rotational temperature shows deviations from the buffer gas temperature, and possible causes for this are discussed. For H(3)O(2)(-) vibrational cooling of the lowest vibrational quantum states into the vibrational ground state is observed. Its photodetachment cross section near threshold is modelled with a Franck-Condon model, with a detachment threshold that is lower, but still in agreement with the expected threshold for this system.

DOI
10.1039/c2cp43186f

Related papers

Photodetachment of Cold OH− in a Multipole Ion Trap

Sebastian H. Trippel, Jochen Mikosch, R. Berhane +3 more

The absolute photodetachment cross section of OH- anions at a rotational and translational temperature of 170 K is determined by measuring the detachment-induced decay rate of the anions in a multipole radio-frequency ion trap. In comparison with previous results, the obtained cross section shows the importance of the initial rotational-state distribution. Using a tomography scan of the photodetachment laser through the trapped ion cloud, the derived cross section is model-independent and thus features a small systematic uncertainty. The tomography also yields the column density of the OH- anions in the 22-pole ion trap in good agreement with the expected trapping potential of a large field free region bound by steep potential walls.

arXiv:physics/0607248•Physical Review Letters•Nov 10, 2006•68 citations

Radiative Rotational Lifetimes and State-Resolved Relative Detachment Cross Sections from Photodetachment Thermometry of Molecular Anions in a Cryogenic Storage Ring

Christian Meyer, Andreas Becker, K. Blaum +23 more

Photodetachment thermometry on a beam of OH^{-} in a cryogenic storage ring cooled to below 10 K is carried out using two-dimensional frequency- and time-dependent photodetachment spectroscopy over 20 min of ion storage. In equilibrium with the low-level blackbody field, we find an effective radiative temperature near 15 K with about 90% of all ions in the rotational ground state. We measure the J=1 natural lifetime (about 193 s) and determine the OH^{-} rotational transition dipole moment with 1.5% uncertainty. We also measure rotationally dependent relative near-threshold photodetachment cross sections for photodetachment thermometry.

arXiv:1707.04889•Physical Review Letters•Jul 14, 2017•58 citations

Modeling state-selective photodetachment in cold ion traps: Rotational state “crowding” in small anions

Franco Antonio Gianturco, Lola González‐Sánchez, Barry P. Mant +1 more

Using accurate ab initio calculations of the interaction forces, we employ a quantum mechanical description of the collisional state-changing processes that occur in a cold ion trap with He as a buffer gas. We generate the corresponding inelastic rates for rotational transitions involving three simple molecular anions OH−(1Σ), MgH−(1Σ), and C2H−(1Σ) colliding with the helium atoms of the trap. We show that the rotational constants of these molecular anions are such that within the low-temperature regimes of a cold ion trap (up to about 50 K), a different proportion of molecular states are significantly populated when loading helium as a buffer gas in the trap. By varying the trap operating conditions, population equilibrium at the relevant range of temperatures is reached within different time scales. In the modeling of the photodetachment experiments, we analyze the effects of varying the chosen values for photodetachment rates as well as the laser photon fluxes. Additionally, the changing of the collision dynamics under different buffer gas densities is examined and the best operating conditions, for the different anions, for yielding higher populations of specific rotational states within the ion traps are extracted. The present modeling thus illustrates possible preparation of the trap conditions for carrying out more efficiently state-selected experiments with the trapped anions.

The Journal of Chemical Physics•Oct 10, 2019•18 citations

Inline cryogenically cooled radio-frequency ion trap as a universal injector for cold ions into an electrostatic ion-beam storage ring: Probing and modeling the dynamics of rotational cooling of OH −

Henrik B. Pedersen, Henrik Juul, Frank K Mikkelsen +2 more

We describe the setup and characterization of a cryogenic multipole radio-frequency (RF) ion trap that enables the accumulation and cooling of mass-selected ions before injection into the SAPHIRA storage ring. To characterize the RF trap setup, we use ${\mathrm{OH}}^{\ensuremath{-}}$ anions and explore the threshold photodetachment cross section measured after storage in SAPHIRA as a probe of the rotational temperature. Beyond the temperature of the ion trap assembly, cooled to 6 K, the final rotational temperature of the ${\mathrm{OH}}^{\ensuremath{-}}$ ions is strongly influenced by the density of cooled He and the actual number of trapped ions while much less affected (possibly unaffected) by the time-varying field of the trap. To obtain rotationally cold ${\mathrm{OH}}^{\ensuremath{-}}$ ions, the RF trap must be operated with low He density and a low number of ions. High He densities, corresponding to a strong coupling of the trapped ions and He gas, lead to a significant rotational heating of the trapped ion ensemble, and the He density seems to limit the actual reachable rotational temperature. We demonstrate that cold ions in the RF trap remain cold for at least 30 ms in the SAPHIRA (300 K) storage ring at a base pressure of $\ensuremath{\sim}8\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}9}\phantom{\rule{0.16em}{0ex}}\mathrm{mbar}$.

Physical Review A•Nov 18, 2022•16 citations

Sympathetic cooling and rotational quenching of molecular anions in a hybrid atom ion trap

Henry López-Carrera

This dissertation reports sympathetic cooling of the molecular hydroxyl anion (OH– ) via collisions with ultra cold rubidium (Rb) atoms. The anion’s translational and rotational degrees of freedom were cooled simultaneously. A new generation hybrid atom-ion trap (HAITrap) has been set up, combining an octupole radio frequency (rf) trap for ion storage and a dark-spontaneous force optical trap (darkSPOT) for Rb atoms. While the octupole rf-trap provides a large rf-field-free region decreasing rf-induced collisional heating, the darkSPOT reinforces this effect by locating the atom cloud in the center of the ion trap. The darkSPOT also enables to generate large dark state fractions, suppressing associative detachment and thus ion losses. Evidence on translational sympathetic cooling in the HAITrap was provided using two methods of kinetic thermometry: photodetachment tomography (PD) and measurements of the time of flight (ToF) distribution. The ToF analysis has shown to be more conclusive and numerical simulations validated the experimental findings qualitatively. Based on a one dimensional ToF-temperature mapping, the narrowest measured energy spread would correspond to a temperature of 35 ± 5K. Deviations from thermal distributions were observed, as predicted from a theoretical model developed by our group. Rotational sympathetic cooling was observed via state selective photodetachment (SSPD). This was performed by pre-cooling the atoms with helium buffer gas at 295K and further cooling the ions with Rb at 300 μK. SSPD thermometry yielded a 70% decrease of the anions rotational temperature after interaction with Rb. These experimental findings could have direct applications in cold collision studies, quantum control of chemical reactions or sympathetic cooling of anti-protons.

•Jan 1, 2018•0 citations

Rotationally cold (> 99% J = 0) OH − molecular ions in a cryogenic storage ring

Gustav Eklund, K. C. Chartkunchand, E. K. Anderson +14 more

We store a 10 keV OH − ion-beam at 13.5 ± 0.5 K in one of the DESIREE storage rings. Using photodetachment thermometry we measure the effective relative photodetachment cross section at different storage times and determine the rotational temperature of the ions to be 13.4 ± 0.2 K in agreement with the macroscopic temperature. A model cross section in the threshold range taking into account the formation of excited neutral OH molecules is calculated as a function of rotational temperature in order to justify the use of the rotational thermometry method developed earlier by the group of Roland Wester at Innsbruck University in the present case. In addition, we apply a selective photodetachment technique to produce an ion beam with more than 99% of the ions in the rotational ground state. The intrinsic lifetime of the J = 1 rotational level is measured to be 145 ± 28 s.

Journal of Physics Conference Series•Nov 1, 2017•1 citation
Photodetachment spectroscopy of OH(-) and H(3)O(2)(-) anions has been performed in a cryogenic 22-pole radiofrequency multipole trap. Measurements of the detachment cross section as a function of laser frequency near threshold have been analysed. Using this bound-free spectroscopy approach we could demonstrate rotational and vibrational cooling of the trapped anions by the buffer gas in the multipole trap. Below 50 K the OH(-) rotational temperature shows deviations from the buffer gas temperature, and possible causes for this are discussed. For H(3)O(2)(-) vibrational cooling of the lowest vibrational quantum states into the vibrational ground state is observed. Its photodetachment cross section near threshold is modelled with a Franck-Condon model, with a detachment threshold that is lower, but still in agreement with the expected threshold for this system.
The absolute photodetachment cross section of OH- anions at a rotational and translational temperature of 170 K is determined by measuring the detachment-induced decay rate of the anions in a multipole radio-frequency ion trap. In comparison with previous results, the obtained cross section shows the importance of the initial rotational-state distribution. Using a tomography scan of the photodetachment laser through the trapped ion cloud, the derived cross section is model-independent and thus features a small systematic uncertainty. The tomography also yields the column density of the OH- anions in the 22-pole ion trap in good agreement with the expected trapping potential of a large field free region bound by steep potential walls.
Photodetachment thermometry on a beam of OH^{-} in a cryogenic storage ring cooled to below 10 K is carried out using two-dimensional frequency- and time-dependent photodetachment spectroscopy over 20 min of ion storage. In equilibrium with the low-level blackbody field, we find an effective radiative temperature near 15 K with about 90% of all ions in the rotational ground state. We measure the J=1 natural lifetime (about 193 s) and determine the OH^{-} rotational transition dipole moment with 1.5% uncertainty. We also measure rotationally dependent relative near-threshold photodetachment cross sections for photodetachment thermometry.
Using accurate ab initio calculations of the interaction forces, we employ a quantum mechanical description of the collisional state-changing processes that occur in a cold ion trap with He as a buffer gas. We generate the corresponding inelastic rates for rotational transitions involving three simple molecular anions OH−(1Σ), MgH−(1Σ), and C2H−(1Σ) colliding with the helium atoms of the trap. We show that the rotational constants of these molecular anions are such that within the low-temperature regimes of a cold ion trap (up to about 50 K), a different proportion of molecular states are significantly populated when loading helium as a buffer gas in the trap. By varying the trap operating conditions, population equilibrium at the relevant range of temperatures is reached within different time scales. In the modeling of the photodetachment experiments, we analyze the effects of varying the chosen values for photodetachment rates as well as the laser photon fluxes. Additionally, the changing of the collision dynamics under different buffer gas densities is examined and the best operating conditions, for the different anions, for yielding higher populations of specific rotational states within the ion traps are extracted. The present modeling thus illustrates possible preparation of the trap conditions for carrying out more efficiently state-selected experiments with the trapped anions.
We describe the setup and characterization of a cryogenic multipole radio-frequency (RF) ion trap that enables the accumulation and cooling of mass-selected ions before injection into the SAPHIRA storage ring. To characterize the RF trap setup, we use ${\mathrm{OH}}^{\ensuremath{-}}$ anions and explore the threshold photodetachment cross section measured after storage in SAPHIRA as a probe of the rotational temperature. Beyond the temperature of the ion trap assembly, cooled to 6 K, the final rotational temperature of the ${\mathrm{OH}}^{\ensuremath{-}}$ ions is strongly influenced by the density of cooled He and the actual number of trapped ions while much less affected (possibly unaffected) by the time-varying field of the trap. To obtain rotationally cold ${\mathrm{OH}}^{\ensuremath{-}}$ ions, the RF trap must be operated with low He density and a low number of ions. High He densities, corresponding to a strong coupling of the trapped ions and He gas, lead to a significant rotational heating of the trapped ion ensemble, and the He density seems to limit the actual reachable rotational temperature. We demonstrate that cold ions in the RF trap remain cold for at least 30 ms in the SAPHIRA (300 K) storage ring at a base pressure of $\ensuremath{\sim}8\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}9}\phantom{\rule{0.16em}{0ex}}\mathrm{mbar}$.
This dissertation reports sympathetic cooling of the molecular hydroxyl anion (OH– ) via collisions with ultra cold rubidium (Rb) atoms. The anion’s translational and rotational degrees of freedom were cooled simultaneously. A new generation hybrid atom-ion trap (HAITrap) has been set up, combining an octupole radio frequency (rf) trap for ion storage and a dark-spontaneous force optical trap (darkSPOT) for Rb atoms. While the octupole rf-trap provides a large rf-field-free region decreasing rf-induced collisional heating, the darkSPOT reinforces this effect by locating the atom cloud in the center of the ion trap. The darkSPOT also enables to generate large dark state fractions, suppressing associative detachment and thus ion losses. Evidence on translational sympathetic cooling in the HAITrap was provided using two methods of kinetic thermometry: photodetachment tomography (PD) and measurements of the time of flight (ToF) distribution. The ToF analysis has shown to be more conclusive and numerical simulations validated the experimental findings qualitatively. Based on a one dimensional ToF-temperature mapping, the narrowest measured energy spread would correspond to a temperature of 35 ± 5K. Deviations from thermal distributions were observed, as predicted from a theoretical model developed by our group. Rotational sympathetic cooling was observed via state selective photodetachment (SSPD). This was performed by pre-cooling the atoms with helium buffer gas at 295K and further cooling the ions with Rb at 300 μK. SSPD thermometry yielded a 70% decrease of the anions rotational temperature after interaction with Rb. These experimental findings could have direct applications in cold collision studies, quantum control of chemical reactions or sympathetic cooling of anti-protons.
We store a 10 keV OH − ion-beam at 13.5 ± 0.5 K in one of the DESIREE storage rings. Using photodetachment thermometry we measure the effective relative photodetachment cross section at different storage times and determine the rotational temperature of the ions to be 13.4 ± 0.2 K in agreement with the macroscopic temperature. A model cross section in the threshold range taking into account the formation of excited neutral OH molecules is calculated as a function of rotational temperature in order to justify the use of the rotational thermometry method developed earlier by the group of Roland Wester at Innsbruck University in the present case. In addition, we apply a selective photodetachment technique to produce an ion beam with more than 99% of the ions in the rotational ground state. The intrinsic lifetime of the J = 1 rotational level is measured to be 145 ± 28 s.