Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:0711.2663

Wide range and highly sensitive atomic magnetometry with Rb vapor

S. M. Iftiquar

Published Nov 16, 2007• 0 citations
arXivHTMLPDF

Abstract

We have developed a technique in which Rb atomic response to weak magnetic field is high and an efficient rotation of linearly polarized laser beam results in efficient magnetometry. 85Rb isotope has been used for the magnetometry in an ordinary vapor cell without any paraffin coating to its inner wall. A linear regime of Faraday rotation of about 25 microT has been observed with atomic number density within the vapor cell of about 10^9 cm-3.

DOI
10.48550/arxiv.0711.2663

Related papers

Sensitive magnetometry based on nonlinear magneto-optical rotation

Dmitry Budker, Derek F. Jackson Kimball, Simon Rochester +2 more

Application of nonlinear magneto-optical (Faraday) rotation to magnetometry is investigated. Our experimental setup consists of a modulation polarimeter that measures rotation of the polarization plane of a laser beam resonant with transitions in Rb. Rb vapor is contained in an evacuated cell with antirelaxation coating that enables atomic ground-state polarization to survive many thousand wall collisions. This leads to ultranarrow features $(\ensuremath{\sim}{10}^{\ensuremath{-}6} \mathrm{G})$ in the magnetic-field dependence of optical rotation. The potential sensitivity of this scheme to sub-$\ensuremath{\mu}\mathrm{G}$ magnetic fields as a function of atomic density, light intensity, and light frequency is investigated near the $D1$ and $D2$ lines of ${}^{85}\mathrm{Rb}.$ It is shown that through an appropriate choice of parameters the shot-noise-limited sensitivity to small magnetic fields can reach $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}12} \mathrm{G}/\sqrt{\mathrm{Hz}}.$

Physical Review A•Sep 11, 2000•338 citations

Spin-exchange relaxation-free magnetometry using elliptically polarized light

Vishal Shah, Michael V. Romalis

Spin-exchange relaxation free alkali-metal magnetometers typically operate in the regime of high optical density, presenting challenges for simple and efficient optical pumping and detection. We describe a high-sensitivity Rb magnetometer using a single elliptically polarized off-resonant laser beam. Circular component of the light creates relatively uniform spin polarization while the linear component is used to measure optical rotation generated by the atoms. Modulation of the atomic spin direction with an oscillating magnetic field shifts the detected signal to high frequencies. Using a fiber-coupled distributed feedback laser, we achieve magnetic field sensitivity of $7\text{ }\text{fT}/\sqrt{\text{Hz}}$ with a miniature $5\ifmmode\times\else\texttimes\fi{}5\ifmmode\times\else\texttimes\fi{}5\text{ }\text{mm}\text{ }\text{Rb}$ vapor cell.

arXiv:0903.2447•Physical Review A•Jul 24, 2009•278 citations

Magnetometry using hot atomic vapors

Martín Romero, Fernando

We demonstrate an ultra-high sensitivity rf optical magnetometer based on a compact 5×5×8 mm3 Rubidium-87 vapor cell in a mu-metal shielded environment. The rf field is detected via a Faraday rotation effect on the linear polarization of a probe beam, and the resonance frequency is tuned via Zeeman effect by applying a static bias magnetic field to the cell. Sensitivities down to 3 fT/√Hz are achieved between 10 kHz and 100 kHz, which is a performance comparable to that of prior larger cells. An increase in the sensitivity with frequency and temperature has been observed.

•Jul 19, 2022•0 citations

Atomic Magnetometer Based on Chip Scale Rb Atomic Vapour Cell

Giridhar M S, Giridhar M S, Ishan Gunjal +4 more

This paper reports the development and characterization of an atomic magnetometer with a microfabricatedRb atomic vapour cell as the sensing element. The measurement principle is based on the Faraday rotation of linearly polarized probe light, which interacts resonantly with atomic spin states in the presence of a magnetic field. In the chip-scale vapour cell (dimensions: 8.0 mm × 12.0 mm × 1.5 mm), the atomic vapour is confined to a micromachined optical cavity of 3.5 µL with an optical path length of 0.5 mm. Optical interrogation is performed using a single laser beam tuned to the D1 absorption resonance of ⁸⁵Rb. The rotation arises due to magnetically induced circular birefringence in the hot atomic vapour. A bench model of the magnetometer is demonstrated over a measurement range of ±50 µT with a maximum uncertainty of 800 nT in an unshielded environment. The magneto-optic rotation (MOR) response in the laboratory was investigated and is observed to vary from 5×10³ rad/T for near zero magnetic field to 3.2×10³ rad/T for ambient geomagnetic field.

Indian Journal of Pure & Applied Physics•Jan 1, 2025•0 citations

A high-sensitivity push-pull magnetometer

E. Breschi, Z. D. Grujić, P. Knowles +1 more

We describe our approach to atomic magnetometry based on the push-pull optical pumping technique. Cesium vapor is pumped and probed by a resonant laser beam whose circular polarization is modulated synchronously with the spin evolution dynamics induced by a static magnetic field. The magnetometer is operated in a phase-locked loop, and it has an intrinsic sensitivity below 20fT/Hz, using a room temperature paraffin-coated cell. We use the magnetometer to monitor magnetic field fluctuations with a sensitivity of 300fT/Hz.

arXiv:1312.3567•Applied Physics Letters•Jan 13, 2014•40 citations

Faraday effect on the Rb D 1 line in a cell with a thickness of half the wavelength of light

Armen D. Sargsyan, Y. Pashayan-Leroy, Claude Leroy +1 more

The rotation of the radiation polarization plane in a longitudinal magnetic field (Faraday effect) on the D 1 line in atomic Rb vapor has been studied with the use of a nanocell with the thickness L varying in the range of 100–900 nm. It has been shown that an important parameter is the ratio L/λ, where λ = 795 nm is the wavelength of laser radiation resonant with the D 1 line. The best parameters of the signal of rotation of the radiation polarization plane have been obtained at the thickness L = λ/2 = 397.5 nm. The fabricated nanocell had a large region with such a thickness. The spectral width of the signal reached at the thickness L = 397.5 nm is approximately 30 MHz, which is much smaller than the spectral width (≈ 500 MHz) reached with ordinary cells with a thickness in the range of 1–100 mm. The parameters of the Faraday rotation signal have been studied as functions of the temperature of the nanocell, the laser power, and the magnetic field strength. The signal has been reliably detected at the laser power P L ≥ 1 μW, magnetic field strength B ≥ 0.5 G, and the temperature of the nanocell T ≥ 100°C. It has been shown that the maximum rotation angle of the polarization plane in the longitudinal magnetic field is reached on the F g = 3 → F e = 2 transition of the 85Rb atom. The spectral profile of the Faraday rotation signal has a specific shape with a sharp peak, which promotes its applications. In particular, Rb atomic transitions in high magnetic fields about 1000 G are split into a large number of components, which are completely spectrally resolved and allow the study of the behavior of an individual transition.

Journal of Experimental and Theoretical Physics•Sep 1, 2016•6 citations
We have developed a technique in which Rb atomic response to weak magnetic field is high and an efficient rotation of linearly polarized laser beam results in efficient magnetometry. 85Rb isotope has been used for the magnetometry in an ordinary vapor cell without any paraffin coating to its inner wall. A linear regime of Faraday rotation of about 25 microT has been observed with atomic number density within the vapor cell of about 10^9 cm-3.
Application of nonlinear magneto-optical (Faraday) rotation to magnetometry is investigated. Our experimental setup consists of a modulation polarimeter that measures rotation of the polarization plane of a laser beam resonant with transitions in Rb. Rb vapor is contained in an evacuated cell with antirelaxation coating that enables atomic ground-state polarization to survive many thousand wall collisions. This leads to ultranarrow features $(\ensuremath{\sim}{10}^{\ensuremath{-}6} \mathrm{G})$ in the magnetic-field dependence of optical rotation. The potential sensitivity of this scheme to sub-$\ensuremath{\mu}\mathrm{G}$ magnetic fields as a function of atomic density, light intensity, and light frequency is investigated near the D1D1D1 and D2D2D2 lines of 85Rb.{}^{85}\mathrm{Rb}.85Rb. It is shown that through an appropriate choice of parameters the shot-noise-limited sensitivity to small magnetic fields can reach $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}12} \mathrm{G}/\sqrt{\mathrm{Hz}}.$
Spin-exchange relaxation free alkali-metal magnetometers typically operate in the regime of high optical density, presenting challenges for simple and efficient optical pumping and detection. We describe a high-sensitivity Rb magnetometer using a single elliptically polarized off-resonant laser beam. Circular component of the light creates relatively uniform spin polarization while the linear component is used to measure optical rotation generated by the atoms. Modulation of the atomic spin direction with an oscillating magnetic field shifts the detected signal to high frequencies. Using a fiber-coupled distributed feedback laser, we achieve magnetic field sensitivity of 7 fT/Hz7\text{ }\text{fT}/\sqrt{\text{Hz}}7 fT/Hz​ with a miniature $5\ifmmode\times\else\texttimes\fi{}5\ifmmode\times\else\texttimes\fi{}5\text{ }\text{mm}\text{ }\text{Rb}$ vapor cell.
We demonstrate an ultra-high sensitivity rf optical magnetometer based on a compact 5×5×8 mm3 Rubidium-87 vapor cell in a mu-metal shielded environment. The rf field is detected via a Faraday rotation effect on the linear polarization of a probe beam, and the resonance frequency is tuned via Zeeman effect by applying a static bias magnetic field to the cell. Sensitivities down to 3 fT/√Hz are achieved between 10 kHz and 100 kHz, which is a performance comparable to that of prior larger cells. An increase in the sensitivity with frequency and temperature has been observed.
This paper reports the development and characterization of an atomic magnetometer with a microfabricatedRb atomic vapour cell as the sensing element. The measurement principle is based on the Faraday rotation of linearly polarized probe light, which interacts resonantly with atomic spin states in the presence of a magnetic field. In the chip-scale vapour cell (dimensions: 8.0 mm × 12.0 mm × 1.5 mm), the atomic vapour is confined to a micromachined optical cavity of 3.5 µL with an optical path length of 0.5 mm. Optical interrogation is performed using a single laser beam tuned to the D1 absorption resonance of ⁸⁵Rb. The rotation arises due to magnetically induced circular birefringence in the hot atomic vapour. A bench model of the magnetometer is demonstrated over a measurement range of ±50 µT with a maximum uncertainty of 800 nT in an unshielded environment. The magneto-optic rotation (MOR) response in the laboratory was investigated and is observed to vary from 5×10³ rad/T for near zero magnetic field to 3.2×10³ rad/T for ambient geomagnetic field.
We describe our approach to atomic magnetometry based on the push-pull optical pumping technique. Cesium vapor is pumped and probed by a resonant laser beam whose circular polarization is modulated synchronously with the spin evolution dynamics induced by a static magnetic field. The magnetometer is operated in a phase-locked loop, and it has an intrinsic sensitivity below 20fT/Hz, using a room temperature paraffin-coated cell. We use the magnetometer to monitor magnetic field fluctuations with a sensitivity of 300fT/Hz.
The rotation of the radiation polarization plane in a longitudinal magnetic field (Faraday effect) on the D 1 line in atomic Rb vapor has been studied with the use of a nanocell with the thickness L varying in the range of 100–900 nm. It has been shown that an important parameter is the ratio L/λ, where λ = 795 nm is the wavelength of laser radiation resonant with the D 1 line. The best parameters of the signal of rotation of the radiation polarization plane have been obtained at the thickness L = λ/2 = 397.5 nm. The fabricated nanocell had a large region with such a thickness. The spectral width of the signal reached at the thickness L = 397.5 nm is approximately 30 MHz, which is much smaller than the spectral width (≈ 500 MHz) reached with ordinary cells with a thickness in the range of 1–100 mm. The parameters of the Faraday rotation signal have been studied as functions of the temperature of the nanocell, the laser power, and the magnetic field strength. The signal has been reliably detected at the laser power P L ≥ 1 μW, magnetic field strength B ≥ 0.5 G, and the temperature of the nanocell T ≥ 100°C. It has been shown that the maximum rotation angle of the polarization plane in the longitudinal magnetic field is reached on the F g = 3 → F e = 2 transition of the 85Rb atom. The spectral profile of the Faraday rotation signal has a specific shape with a sharp peak, which promotes its applications. In particular, Rb atomic transitions in high magnetic fields about 1000 G are split into a large number of components, which are completely spectrally resolved and allow the study of the behavior of an individual transition.