Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1312.3567 · Applied Physics Letters

A high-sensitivity push-pull magnetometer

E. Breschi, Z. D. Grujić, P. Knowles, Antoine Weis

Published Jan 13, 2014• 40 citations
arXivHTMLPDF

Abstract

We describe our approach to atomic magnetometry based on the push-pull optical pumping technique. Cesium vapor is pumped and probed by a resonant laser beam whose circular polarization is modulated synchronously with the spin evolution dynamics induced by a static magnetic field. The magnetometer is operated in a phase-locked loop, and it has an intrinsic sensitivity below 20fT/Hz, using a room temperature paraffin-coated cell. We use the magnetometer to monitor magnetic field fluctuations with a sensitivity of 300fT/Hz.

DOI
10.1063/1.4861458

Related papers

A Design of Cesium Atomic Magnetometer Based on Circular Dichroism

Xian Jin Zeng, Mo Si Hao, Qing Meng Li +3 more

Recently, atomic magnetometers have been reported as the most sensitive magnetometers by completely eliminating the spin exchange relaxation. In this paper, we described a design of highly sensitive cesium atomic magnetometer based on circular dichroism, which had the advantage of easily locking the probing laser to the necessary frequency compared with those based on circular birefringence. In order to polarize the cesium atoms uniformly, the pumping laser light was separated into two counter-propagating and counter-circular polarization beams through the atomic vapor cell. We employed a circular analyzer optical configuration to measure the ellipticity of the probing light, which indicated the amplitude of the magnetic field. The external magnetic field was tracked by a digital auto frequency tracking system.

Applied Mechanics and Materials•Oct 1, 2012•3 citations

Spin-exchange relaxation-free magnetometry using elliptically polarized light

Vishal Shah, Michael V. Romalis

Spin-exchange relaxation free alkali-metal magnetometers typically operate in the regime of high optical density, presenting challenges for simple and efficient optical pumping and detection. We describe a high-sensitivity Rb magnetometer using a single elliptically polarized off-resonant laser beam. Circular component of the light creates relatively uniform spin polarization while the linear component is used to measure optical rotation generated by the atoms. Modulation of the atomic spin direction with an oscillating magnetic field shifts the detected signal to high frequencies. Using a fiber-coupled distributed feedback laser, we achieve magnetic field sensitivity of $7\text{ }\text{fT}/\sqrt{\text{Hz}}$ with a miniature $5\ifmmode\times\else\texttimes\fi{}5\ifmmode\times\else\texttimes\fi{}5\text{ }\text{mm}\text{ }\text{Rb}$ vapor cell.

arXiv:0903.2447•Physical Review A•Jul 24, 2009•278 citations

A highly drift-stable atomic magnetometer for fundamental physics experiments

Martin Rosner, BECK Douglas howard, P. Fierlinger +7 more

We report the design and performance of a nonmagnetic drift stable optically pumped cesium magnetometer with a measured sensitivity of 35 fT at 200 s integration time and stability below 50 fT between 70 and 600 s. The sensor is based on the nonlinear magneto-optical rotation effect: in a Bell–Bloom configuration, a higher order polarization moment (alignment) of Cs atoms is created with a pump laser beam in an anti-relaxation coated Pyrex cell under vacuum, filled with Cs vapor at room temperature. The polarization plane of light passing through the cell is modulated due the precession of the atoms in an external magnetic field of 2.1 μT, used to optically determine the Larmor precession frequency. Operation is based on a sequence of optical pumping and observation of freely precessing spins at a repetition rate of 8 Hz. This free precession decay readout scheme separates optical pumping and probing and, thus, ensures a systematically highly clean measurement. Due to the residual offset of the sensor of <15 pT together with negligible crosstalk of adjacent sensors, this device is uniquely suitable for a variety of experiments in low-energy particle physics with extreme precision, here as a highly stable and systematically clean reference probe in search for time-reversal symmetry violating electric dipole moments.

arXiv:2201.06936•Applied Physics Letters•Apr 18, 2022•31 citations

Subpicotesla scalar atomic magnetometer with a microfabricated cell

Rui Zhang, Terry Dyer, Nathan Brockie +2 more

We demonstrated a scalar atomic magnetometer using a microfabricated Cs vapor cell. The atomic spin precession is driven by an amplitude-modulated circularly-polarized pump laser resonant on the D1 transition of Cs atoms and detected by an off-resonant linearly-polarized probe laser using a balanced polarimeter setup. Under a magnetic field with amplitude in the Earth's magnetic field range, the magnetometer in the gradiometer mode can reach sensitivities below 150fT/Hz, which shows that the magnetometer by itself can achieve sub-100fT/Hz sensitivities. In addition to its high sensitivity, the magnetometer has a bandwidth close to 1 kHz due to the broad magnetic resonance inside the small vapor cell. Our experiment suggests the feasibility of a portable low-power and high-performance magnetometer which can be operated in the Earth's magnetic field. Such a device will greatly reduce the restrictions on the operating environment and expand the range of applications for atomic magnetometers, such as detection of nuclear magnetic resonance in low magnetic fields.

arXiv:1910.01768•Journal of Applied Physics•Sep 26, 2019•17 citations

Pulsed operation of a miniature scalar optically pumped magnetometer

Vladislav P. Gerginov, Sean Krzyzewski, Svenja A. Knappe

A scalar magnetic field sensor based on a millimeter-size Rb87 vapor cell is described. The magnetometer uses nearly copropagating pump and probe laser beams, amplitude modulation of the pump beam, and detection through monitoring the polarization rotation of the detuned probe beam. The circularly polarized pump laser resonantly drives a spin precession in the alkali atoms at the Larmor frequency. A modulation signal on the probe laser polarization is detected with a lock-in amplifier. Since the Larmor precession is driven all-optically, potential cross talk between sensors is minimized. And since the pump light is turned off during most of the precession cycle, large offsets of the resonance, typically present in a single-beam Bell–Bloom scheme, are avoided. At the same time, relatively high sensitivities can be reached even in millimeter-size vapor cells: The magnetometer achieves a sensitivity of 1 pT/Hz1/2 in a sensitive volume of 16 mm3, limited by environmental noise. When a gradiometer configuration is used to cancel the environmental noise, the magnetometer sensitivity reaches 300 fT/Hz1/2. We systematically study the dependence of the magnetometer performance on the optical duty cycles of the pump light and find that better performance is achieved with shorter duty cycles, with the highest values measured at 1.25% duty cycle.

Journal of the Optical Society of America B•Jun 15, 2017•58 citations

Study on the sensitivity of laser-pumped cesium atomic magnetometer

Nan Li, Huang Kai-Kai, Xuanhui Lu

A cesium atomic magnetometer based on laser-pumped rf resonance has been investigated and demonstrated experimentally. Atoms are polarized and pumped to dark states by circularly polarized light. When there exists a magnetic field, the corresponding magnetization will be precessing around the magnetic field at Larmor frequency. By means of adding a resonant rf magnetic field, the atoms will be depolarized and absorb photons again. By detecting the spectrum of the transmitted light, one can obtain the information about the external magnetic field. We build an 894nm external cavity diode laser with a frequency stabilization device, and a low noise magnetic field measurement environment. After the optimization of the magnetometer parameter and closed-loop measurement, an ultimate sensitivity of 19 fT/Hz1/2 and an intrinsic sensitivity of 1.8 pT/Hz1/2 have been achieved with the spatial resolution smaller than 2 cm.

Acta Physica Sinica•Jan 1, 2013•4 citations
We describe our approach to atomic magnetometry based on the push-pull optical pumping technique. Cesium vapor is pumped and probed by a resonant laser beam whose circular polarization is modulated synchronously with the spin evolution dynamics induced by a static magnetic field. The magnetometer is operated in a phase-locked loop, and it has an intrinsic sensitivity below 20fT/Hz, using a room temperature paraffin-coated cell. We use the magnetometer to monitor magnetic field fluctuations with a sensitivity of 300fT/Hz.
Recently, atomic magnetometers have been reported as the most sensitive magnetometers by completely eliminating the spin exchange relaxation. In this paper, we described a design of highly sensitive cesium atomic magnetometer based on circular dichroism, which had the advantage of easily locking the probing laser to the necessary frequency compared with those based on circular birefringence. In order to polarize the cesium atoms uniformly, the pumping laser light was separated into two counter-propagating and counter-circular polarization beams through the atomic vapor cell. We employed a circular analyzer optical configuration to measure the ellipticity of the probing light, which indicated the amplitude of the magnetic field. The external magnetic field was tracked by a digital auto frequency tracking system.
Spin-exchange relaxation free alkali-metal magnetometers typically operate in the regime of high optical density, presenting challenges for simple and efficient optical pumping and detection. We describe a high-sensitivity Rb magnetometer using a single elliptically polarized off-resonant laser beam. Circular component of the light creates relatively uniform spin polarization while the linear component is used to measure optical rotation generated by the atoms. Modulation of the atomic spin direction with an oscillating magnetic field shifts the detected signal to high frequencies. Using a fiber-coupled distributed feedback laser, we achieve magnetic field sensitivity of 7 fT/Hz7\text{ }\text{fT}/\sqrt{\text{Hz}}7 fT/Hz​ with a miniature $5\ifmmode\times\else\texttimes\fi{}5\ifmmode\times\else\texttimes\fi{}5\text{ }\text{mm}\text{ }\text{Rb}$ vapor cell.
We report the design and performance of a nonmagnetic drift stable optically pumped cesium magnetometer with a measured sensitivity of 35 fT at 200 s integration time and stability below 50 fT between 70 and 600 s. The sensor is based on the nonlinear magneto-optical rotation effect: in a Bell–Bloom configuration, a higher order polarization moment (alignment) of Cs atoms is created with a pump laser beam in an anti-relaxation coated Pyrex cell under vacuum, filled with Cs vapor at room temperature. The polarization plane of light passing through the cell is modulated due the precession of the atoms in an external magnetic field of 2.1 μT, used to optically determine the Larmor precession frequency. Operation is based on a sequence of optical pumping and observation of freely precessing spins at a repetition rate of 8 Hz. This free precession decay readout scheme separates optical pumping and probing and, thus, ensures a systematically highly clean measurement. Due to the residual offset of the sensor of <15 pT together with negligible crosstalk of adjacent sensors, this device is uniquely suitable for a variety of experiments in low-energy particle physics with extreme precision, here as a highly stable and systematically clean reference probe in search for time-reversal symmetry violating electric dipole moments.
We demonstrated a scalar atomic magnetometer using a microfabricated Cs vapor cell. The atomic spin precession is driven by an amplitude-modulated circularly-polarized pump laser resonant on the D1 transition of Cs atoms and detected by an off-resonant linearly-polarized probe laser using a balanced polarimeter setup. Under a magnetic field with amplitude in the Earth's magnetic field range, the magnetometer in the gradiometer mode can reach sensitivities below 150fT/Hz, which shows that the magnetometer by itself can achieve sub-100fT/Hz sensitivities. In addition to its high sensitivity, the magnetometer has a bandwidth close to 1 kHz due to the broad magnetic resonance inside the small vapor cell. Our experiment suggests the feasibility of a portable low-power and high-performance magnetometer which can be operated in the Earth's magnetic field. Such a device will greatly reduce the restrictions on the operating environment and expand the range of applications for atomic magnetometers, such as detection of nuclear magnetic resonance in low magnetic fields.
A scalar magnetic field sensor based on a millimeter-size Rb87 vapor cell is described. The magnetometer uses nearly copropagating pump and probe laser beams, amplitude modulation of the pump beam, and detection through monitoring the polarization rotation of the detuned probe beam. The circularly polarized pump laser resonantly drives a spin precession in the alkali atoms at the Larmor frequency. A modulation signal on the probe laser polarization is detected with a lock-in amplifier. Since the Larmor precession is driven all-optically, potential cross talk between sensors is minimized. And since the pump light is turned off during most of the precession cycle, large offsets of the resonance, typically present in a single-beam Bell–Bloom scheme, are avoided. At the same time, relatively high sensitivities can be reached even in millimeter-size vapor cells: The magnetometer achieves a sensitivity of 1 pT/Hz1/2 in a sensitive volume of 16 mm3, limited by environmental noise. When a gradiometer configuration is used to cancel the environmental noise, the magnetometer sensitivity reaches 300 fT/Hz1/2. We systematically study the dependence of the magnetometer performance on the optical duty cycles of the pump light and find that better performance is achieved with shorter duty cycles, with the highest values measured at 1.25% duty cycle.
A cesium atomic magnetometer based on laser-pumped rf resonance has been investigated and demonstrated experimentally. Atoms are polarized and pumped to dark states by circularly polarized light. When there exists a magnetic field, the corresponding magnetization will be precessing around the magnetic field at Larmor frequency. By means of adding a resonant rf magnetic field, the atoms will be depolarized and absorb photons again. By detecting the spectrum of the transmitted light, one can obtain the information about the external magnetic field. We build an 894nm external cavity diode laser with a frequency stabilization device, and a low noise magnetic field measurement environment. After the optimization of the magnetometer parameter and closed-loop measurement, an ultimate sensitivity of 19 fT/Hz1/2 and an intrinsic sensitivity of 1.8 pT/Hz1/2 have been achieved with the spatial resolution smaller than 2 cm.