Spin-exchange relaxation free alkali-metal magnetometers typically operate in the regime of high optical density, presenting challenges for simple and efficient optical pumping and detection. We describe a high-sensitivity Rb magnetometer using a single elliptically polarized off-resonant laser beam. Circular component of the light creates relatively uniform spin polarization while the linear component is used to measure optical rotation generated by the atoms. Modulation of the atomic spin direction with an oscillating magnetic field shifts the detected signal to high frequencies. Using a fiber-coupled distributed feedback laser, we achieve magnetic field sensitivity of $7\text{ }\text{fT}/\sqrt{\text{Hz}}$ with a miniature $5\ifmmode\times\else\texttimes\fi{}5\ifmmode\times\else\texttimes\fi{}5\text{ }\text{mm}\text{ }\text{Rb}$ vapor cell.
Spin-exchange relaxation free alkali-metal magnetometers typically operate in the regime of high optical density, presenting challenges for simple and efficient optical pumping and detection. We describe a high-sensitivity Rb magnetometer using a single elliptically polarized off-resonant laser beam. Circular component of the light creates relatively uniform spin polarization while the linear component is used to measure optical rotation generated by the atoms. Modulation of the atomic spin direction with an oscillating magnetic field shifts the detected signal to high frequencies. Using a fiber-coupled distributed feedback laser, we achieve magnetic field sensitivity of 7fT/Hz with a miniature 5\ifmmode×\else\texttimes\fi5\ifmmode×\else\texttimes\fi5mmRb vapor cell.
The electronic spin polarization of alkali-metal-vapor atoms is a pivotal parameter for atomic magnetometers. Herein, a novel method is presented for determining the spin polarization with a miniaturized single-beam spin-exchange-relaxation-free (SERF) magnetometer on the basis of zero-field cross-over resonance. Two separate laser beams are utilized to heat the cell and interrogate the vapor atoms, respectively. Spin polarization can be extracted by measuring the resonance response signal of the magnetometer to the transverse magnetic field under different irradiances. Results of these experiments are consistent well with the theoretical predictions with the maximum deviation less than 4%. The proposed method has the integrated advantages of possessing a simple configuration and in-situ measurement. Furthermore, combined with a homemade optical differential detection system with a factor of approximately three of the power noise suppression, the developed single-beam SERF atomic magnetometer with a measuring sensitivity of 32 fT/Hz 1/2 has been achieved. This demonstrated approach can help guide the development of chip-scale atomic magnetometers for bio-magnetic field imaging applications.
We demonstrate a single-beam atomic magnetometer (AM) capable of measuring a three-axis magnetic field with high-sensitivity, achieved by applying a small DC offset field and a high frequency modulation field. To satisfy the miniaturization demand of AMs, an elliptically polarized light detuned by 50 GHz from the resonance transition center is employed. The circularly polarized component is used to polarize the alkali-metal atoms, while the linearly polarized light is used to detect the dynamics of the polarized spin under a magnetic field. Based on theoretical analysis, parameters that significantly affect the performance are optimized, and a sensitivity of 20 fT/Hz 1/2 in x -axis, 25 fT/Hz 1/2 in y -axis, 30 fT/Hz 1/2 in z -axis is achieved with a miniature 4 × 4 × 4 mm 87 Rb vapor cell. Moreover, we also verify that the operation principle of AMs can be used to null background magnetic fields in-situ with isotropic compensation resolution of 6.7 pT, which provides an effectively precise method for zeroing ambient magnetic field. The high-sensitivity operating of an elliptically-polarized-laser-based magnetometer provides prospective futures for constructing a compact, low-cost AM, which is particularly applicable for non-invasive bio-magnetic imaging such as array-based magnetoencephalography (MEG) and magnetocardiography (MCG).
We investigate the ground-state Hanle effect in alkali-metal vapor irradiating by a resonant elliptically polarized light wave. The magneto-optical resonances are observed as a change in the ellipticity parameter of the light wave polarization when scanning the transverse magnetic field near zero. We use a miniature (≈0.125 cm3) glass cesium vapor cell heated to a relatively low temperature of ≈85∘C. Under the current experimental conditions, the sensitivity of magnetic field measurements is limited by a technical noise, reaching 180 fT/√Hz in a 200 Hz bandwidth. The ultimate photon-shot-noise-limited sensitivity of the method is estimated to be ≈5 fT/√Hz. The proposed scheme is promising for the development of a zero-field atomic magnetometer with reduced heat dissipation of the sensor head and relaxed requirements for magnetic shielding compared to counterparts operating in the spin-exchange relaxation-free regime. These features are of particular value for biomedical applications.
We investigate an all-optical scheme for high-sensitivity measurements of the Earth's scale magnetic field (B). The scheme is based on the Bell-Bloom technique with frequency-modulated light. A single elliptically polarized light beam is used both for pumping the alkali-metal atoms and probing Larmor precession of their spins under the external magnetic field. In contrast to many other high-sensitivity magnetometry schemes based on nonlinear polarization rotation of the light, the proposed approach enables the observation of magnetic resonance via changes in the light-beam ellipticity parameter. The approach has been validated in experiments with a vertical-cavity surface-emitting laser, irradiating a 0.125 cm3 cesium vapor cell filled with a buffer gas. In the current experimental conditions, the achieved sensitivity is estimated at 220 fT/√Hz under B≈50μT, while the shot-noise floor corresponds to ≈20 fT/√Hz. The bandwidth is estimated at ≈1 kHz. The proposed simple and robust single-beam scheme is well suited for miniaturization and is therefore particularly promising for the development of compact, highly sensitive, low-power-consumption atomic magnetometers for a wide range of applications in the geomagnetic field.
The ultra-sensitivity magnetometer plays an important role in fundamental physics and applications, including magnetoencephalography (MEG) and magnetocardiography (MCG). The spin-exchange relaxation-free (SERF) atomic magnetometer (AM) has great sensitivity but is limited by the relatively complicated dual-beam structure for application, leading to the development of the compact AM based on one single laser beam. Compared with the single-beam optically pumped magnetometer (OPM) detecting the absorption of the circularly polarized beam, the SERF AM based on an elliptically polarized single beam detecting the optical rotation angle of polarization has a better response, lower laser power, and no need for signal modulation or demodulation. Here, we would like to report an elliptically-polarized single-beam SERF AM enhanced by reflecting the probe beam, increasing the light-atom interaction. Moreover, unlike the previous reflecting AM using the beam splitter, we used a D-shape mirror to extract the reflected beam, avoiding power losses of both incident and reflected beam and destruction of polarization. The sensitivity of our device in the reflecting scheme reaches 5 fT/Hz1/2 at 9–60 Hz, satisfying the need to measure the human MEG/MCG or search for the fifth force. Our research paves the way for developing the compact SERF AM for multiple future applications.
A scalar magnetic field sensor based on a millimeter-size Rb87 vapor cell is described. The magnetometer uses nearly copropagating pump and probe laser beams, amplitude modulation of the pump beam, and detection through monitoring the polarization rotation of the detuned probe beam. The circularly polarized pump laser resonantly drives a spin precession in the alkali atoms at the Larmor frequency. A modulation signal on the probe laser polarization is detected with a lock-in amplifier. Since the Larmor precession is driven all-optically, potential cross talk between sensors is minimized. And since the pump light is turned off during most of the precession cycle, large offsets of the resonance, typically present in a single-beam Bell–Bloom scheme, are avoided. At the same time, relatively high sensitivities can be reached even in millimeter-size vapor cells: The magnetometer achieves a sensitivity of 1 pT/Hz1/2 in a sensitive volume of 16 mm3, limited by environmental noise. When a gradiometer configuration is used to cancel the environmental noise, the magnetometer sensitivity reaches 300 fT/Hz1/2. We systematically study the dependence of the magnetometer performance on the optical duty cycles of the pump light and find that better performance is achieved with shorter duty cycles, with the highest values measured at 1.25% duty cycle.