Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:quant-ph/0610116 · Physical Review A

Electronic noise in optical homodyne tomography

J. Appel, Dallas Hoffman, Eden V. Figueroa, Alexander I. Lvovsky

Published Mar 29, 2007• 113 citations
arXivHTMLPDF

Abstract

The effect of the detector electronic noise in an optical homodyne tomography experiment is shown to be equivalent to optical loss if the detector is calibrated by measuring the quadrature noise of the vacuum state. An explicit relation between the electronic noise level and the equivalent optical efficiency is obtained and confirmed in an experiment with a narrow-band squeezed vacuum source operating at an atomic rubidium wavelength.

DOI
10.1103/physreva.75.035802

Related papers

Observation of Squeezed States Generated by Four-Wave Mixing in an Optical Cavity

R. E. Slusher, Leo W. Hollberg, Bernard Yurke +2 more

Squeezed states of the electromagnetic field have been generated by nondegenerate four-wave mixing due to Na atoms in an optical cavity. The optical noise in the cavity, comprised of primarily vacuum fluctuations and a small component of spontaneous emission from the pumped Na atoms, is amplified in one quadrature of the optical field and deamplified in the other quadrature. These quadrature components are measured with a balanced homodyne detector. The total noise level in the deamplified quadrature drops below the vacuum noise level.

Physical Review Letters•Nov 25, 1985•1,914 citations

Observation of Squeezed States Generated by Four-Wave Mixing in an Optical Cavity

R. E. Slusher, Leo W. Hollberg, Bernard Yurke +2 more

Squeezed states of the electromagnetic field have been generated by nondegenerate four-wave mixing due to Na atoms in an optical cavity. The optical noise in the cavity, comprised of primarily vacuum fluctuations and a small component of spontaneous emission from the pumped Na atoms, is amplified in one quadrature of the optical field and deamplified in the other quadrature. These quadrature components are measured with a balanced homodyne detector. The total noise level in the deamplified quadrature drops below the vacuum noise level.

Physical Review Letters•Feb 17, 1986•33 citations

Measurement of the Wigner distribution and the density matrix of a light mode using optical homodyne tomography: Application to squeezed states and the vacuum

D. T. Smithey, M. Beck, Michael G. Raymer +1 more

We have measured probability distributions of quadrature-field amplitude for both vacuum and quadrature-squeezed states of a mode of the electromagnetic field. From these measurements we demonstrate the technique of optical homodyne tomography to determine the Wigner distribution and the density matrix of the mode. This provides a complete quantum mechanical characterization of the measured mode.

Physical Review Letters•Mar 1, 1993•1,546 citations

Effect of imperfect homodyne visibility on multi-spatial-mode two-mode squeezing measurements

Prasoon Gupta, Rory W. Speirs, K. M. Jones +1 more

We study the effect of homodyne detector visibility on the measurement of quadrature squeezing for a spatially multi-mode source of two-mode squeezed light. Sources like optical parametric oscillators (OPO) typically produce squeezing in a single spatial mode because the nonlinear medium is within a mode-selective optical cavity. For such a source, imperfect interference visibility in the homodyne detector couples in additional vacuum noise, which can be accounted for by introducing an equivalent loss term. In a free-space multi-spatial-mode system imperfect homodyne detector visibility can couple in uncorrelated squeezed modes, and hence can cause faster degradation of the measured squeezing. We show experimentally the dependence of the measured squeezing level on the visibility of homodyne detectors used to probe two-mode squeezed states produced by a free space four-wave mixing process in 85 Rb vapor, and also demonstrate that a simple theoretical model agrees closely with the experimental data.

arXiv:2001.06031•Optics Express•Dec 12, 2019•17 citations

Robustness of homodyne tomography to phase-insensitive noise

Giacomo Mauro D’Ariano, Nicoletta Sterpi

We study the effects of phase-insensitive noise on homodyne measurements of a radiation density matrix. We prove that this noise has an effect equivalent to a non-unit quantum efficiency at detectors. The overall effective quantum efficiency η∗ of the measurement is evaluated in terms of the quantum efficiency at detectors and of the average number of noise photons added to the radiation field. For pure Gaussian-displacement noise, we show that half a photon of noise is enough to prevent the homodyne measurement of the density matrix.

Journal of Modern Optics•Nov 1, 1997•7 citations

Experimental quantum tomography of a homodyne detector

Samuele Grandi, Alessandro Zavatta, Marco Bellini +1 more

We suggest and demonstrate a tomographic method to characterise homodyne detectors at the quantum level.The positive operator measure associated with the detector is expanded in a quadrature basis and probed with a set of coherent states.The coefficients of the expansion are then retrieved using a least squares algorithm.Our model is general enough to describe different implementations of the homodyne setup, and it has proven capable of effectively describing the detector response to different tomographic sets.We validate the reconstructed operator measure on nonclassical states and exploit results to estimate the overall quantum efficiency of the detector.

arXiv:1505.03297•New Journal of Physics•Apr 25, 2017•50 citations
The effect of the detector electronic noise in an optical homodyne tomography experiment is shown to be equivalent to optical loss if the detector is calibrated by measuring the quadrature noise of the vacuum state. An explicit relation between the electronic noise level and the equivalent optical efficiency is obtained and confirmed in an experiment with a narrow-band squeezed vacuum source operating at an atomic rubidium wavelength.
Squeezed states of the electromagnetic field have been generated by nondegenerate four-wave mixing due to Na atoms in an optical cavity. The optical noise in the cavity, comprised of primarily vacuum fluctuations and a small component of spontaneous emission from the pumped Na atoms, is amplified in one quadrature of the optical field and deamplified in the other quadrature. These quadrature components are measured with a balanced homodyne detector. The total noise level in the deamplified quadrature drops below the vacuum noise level.
Squeezed states of the electromagnetic field have been generated by nondegenerate four-wave mixing due to Na atoms in an optical cavity. The optical noise in the cavity, comprised of primarily vacuum fluctuations and a small component of spontaneous emission from the pumped Na atoms, is amplified in one quadrature of the optical field and deamplified in the other quadrature. These quadrature components are measured with a balanced homodyne detector. The total noise level in the deamplified quadrature drops below the vacuum noise level.
We study the effect of homodyne detector visibility on the measurement of quadrature squeezing for a spatially multi-mode source of two-mode squeezed light. Sources like optical parametric oscillators (OPO) typically produce squeezing in a single spatial mode because the nonlinear medium is within a mode-selective optical cavity. For such a source, imperfect interference visibility in the homodyne detector couples in additional vacuum noise, which can be accounted for by introducing an equivalent loss term. In a free-space multi-spatial-mode system imperfect homodyne detector visibility can couple in uncorrelated squeezed modes, and hence can cause faster degradation of the measured squeezing. We show experimentally the dependence of the measured squeezing level on the visibility of homodyne detectors used to probe two-mode squeezed states produced by a free space four-wave mixing process in 85 Rb vapor, and also demonstrate that a simple theoretical model agrees closely with the experimental data.
We study the effects of phase-insensitive noise on homodyne measurements of a radiation density matrix. We prove that this noise has an effect equivalent to a non-unit quantum efficiency at detectors. The overall effective quantum efficiency η∗ of the measurement is evaluated in terms of the quantum efficiency at detectors and of the average number of noise photons added to the radiation field. For pure Gaussian-displacement noise, we show that half a photon of noise is enough to prevent the homodyne measurement of the density matrix.
We suggest and demonstrate a tomographic method to characterise homodyne detectors at the quantum level.The positive operator measure associated with the detector is expanded in a quadrature basis and probed with a set of coherent states.The coefficients of the expansion are then retrieved using a least squares algorithm.Our model is general enough to describe different implementations of the homodyne setup, and it has proven capable of effectively describing the detector response to different tomographic sets.We validate the reconstructed operator measure on nonclassical states and exploit results to estimate the overall quantum efficiency of the detector.