We study the effect of homodyne detector visibility on the measurement of quadrature squeezing for a spatially multi-mode source of two-mode squeezed light. Sources like optical parametric oscillators (OPO) typically produce squeezing in a single spatial mode because the nonlinear medium is within a mode-selective optical cavity. For such a source, imperfect interference visibility in the homodyne detector couples in additional vacuum noise, which can be accounted for by introducing an equivalent loss term. In a free-space multi-spatial-mode system imperfect homodyne detector visibility can couple in uncorrelated squeezed modes, and hence can cause faster degradation of the measured squeezing. We show experimentally the dependence of the measured squeezing level on the visibility of homodyne detectors used to probe two-mode squeezed states produced by a free space four-wave mixing process in 85 Rb vapor, and also demonstrate that a simple theoretical model agrees closely with the experimental data.
We study the effect of homodyne detector visibility on the measurement of quadrature squeezing for a spatially multi-mode source of two-mode squeezed light. Sources like optical parametric oscillators (OPO) typically produce squeezing in a single spatial mode because the nonlinear medium is within a mode-selective optical cavity. For such a source, imperfect interference visibility in the homodyne detector couples in additional vacuum noise, which can be accounted for by introducing an equivalent loss term. In a free-space multi-spatial-mode system imperfect homodyne detector visibility can couple in uncorrelated squeezed modes, and hence can cause faster degradation of the measured squeezing. We show experimentally the dependence of the measured squeezing level on the visibility of homodyne detectors used to probe two-mode squeezed states produced by a free space four-wave mixing process in 85 Rb vapor, and also demonstrate that a simple theoretical model agrees closely with the experimental data.
The spatial character of the noise on a light field affects its usefulness for imaging. Multi-spatial-mode (MSM) squeezed light has noise below the quantum noise limit in multiple spatial modes, and can be used for super resolution imaging. The generation of such light has long been an experimental goal within the field of quantum optics. \n \nThis work introduces the theory behind the generation of squeezed light, and its measurement using a homodyne detector. A four-wave mixing process in a rubidium 85 vapour is used to experimentally generate squeezed light. The properties of this squeezed light are investigated, through the use of homodyne detection with a bichromatic LO. \n \nThis thesis further investigates how the squeezed quadrature changes from amplitude to phase over a range of 40 MHz. The MSM nature of a squeezed light field is directly investigated. The field is shown to contain at least 75 squeezed spatial modes in the frequency domain, each squeezed at a level of up to -2.5 dB. This thesis develops techniques to measure the spatial character of noise on a light field in the time domain. These are promising techniques for the analysis of the MSM nature of a squeezed light in the time domain.
Multimode squeezed light is a key resource for quantum technologies, enabling applications in boson sampling, quantum networks, and optical quantum computation [1],[2]. Parametric down-conversion in synchronously pumped optical parametric oscillators (SPOPOs) offers a versatile platform for generating multimode squeezed states across the time-frequency domain. In these systems, supermodes manifest as independent quantum states in the temporal domain and as frequency combs in the spectral domain [3]. Precise control of these states is crucial for quantum applications and requires an experimental setup capable of fine-tuning multiple parameters to optimize squeezing properties. In this work, we present an experimental setup for generating and characterizing multimode vacuum squeezed states using a SPOPO and a balanced homodyne detection scheme. Two spatial light modulators (SLMs) placed on the pump and local oscillator (LO) beams provide full control over their spectral properties, including amplitude and phase shaping. This flexibility allows us to optimize the experimental conditions and investigate squeezing dependence on key parameters such as the LO spectral detuning and bandwidth. By introducing a programmableπ-phase shift to the LO via the SLM, we selectively probe the multimode structure, distinguishing between even and odd supermodes. Additionally, the SLM on the pump can introduce an arbitrary chirp, further enhancing control over the system. Our setup, schematized in Figure 1a, is based on a commercial mode-locked Yb-fiber laser operating at 93MHz, emitting pulses centered at 1035nm with a 10nm bandwidth. A portion of the radiation is frequency-doubled to 517.5nm via an LBO crystal to serve as the pump for the SPOPO, while the remaining part is used as the LO for homodyne detection after transmission through the SPOPO cavity, ensuring high beam quality. The SPOPO cavity is frequency-locked to the laser via a Pound-Drever-Hall technique, ensuring stable and optimized operation. Figure 1b presents representative measurements of squeezing levels as a function of the LO spectral bandwidth, showing how its symmetric or antisymmetric phase influences the detection of different supermodes and, consequently, the squeezing level depending on their structure. The measurements were performed using lithium niobate (LNB) nonlinear crystals of 3.0mm and 1.5mm lengths. Our setup allows for future investigations of dispersion effects on squeezing, thus far only theoretically predicted [4], by introducing chirped mirrors for dispersion compensation. Moreover, different nonlinear crystals, such as lithium niobate, beta barium borate (BBO), and lithium triborate (LBO) of various lengths, will be tested to explore the multimode properties of the squeezed states. These investigations will provide insights into the experimental conditions required to achieve single-mode squeezing, crucial for applications such as Gaussian Boson Sampling, with results to be presented at the conference.
The four-wave-mixing interactions produced by pumping at two well-separated frequencies can couple four different radiation modes to generate a new kind of squeezed state of light. A dual-frequency homodyne detection scheme is described and is used to observe this type of nonclassical correlation. Initial experimental results in an optical fiber show a noise level 20% below the vacuum noise level for the output of the dual-frequency detector, even though the noise at each individual detector remains above the vacuum level.
We observe -9.01+/-0.14 dB of squeezing and +15.12+/-0.14 dB of antisqueezing with a local oscillator phase locked in homodyne measurement. Suzuki et al. have pointed out two main factors in [Appl. Phys. Lett. 89, 061116 (2006)], which degrade the observed squeezing level:phase fluctuation in homodyne measurement and intracavity losses of an optical parametric oscillator for squeezing. We have improved the phase stability of homodyne measurement and have reduced the intracavity losses. We measure pump power dependences of the squeezing and antisqueezing levels, which show good agreement with theoretical calculations taking account of the phase fluctuation.
The quantum statistics of a laser result in noise when measurements of the beam are made. This noise sets a classical limit beyond which a laser cannot be used with increasing sensitivity. This quantum noise limit is imposed on many of the uses of lasers currently, especially in power limited devices such as optical communications. The statistics of the laser photon field can be modified to produce a non-classical state resulting in lower noise than the quantum noise limit when detected appropriately. This state, called a squeezed state, has been measured previously from a cavity enhanced optical parametric oscillator (OPO) only at frequency sidebands within the linewidth of the cavity. ¶ This thesis reports measurements of squeezing at microwave frequency sidebands on an optical beam produced by an optical parametric oscillator. This is the first reported measurement of squeezing at frequency sidebands at higher longitudinal modes of the cavity from an OPO. Noise reduction below the quantum noise limit is measured at sideband frequencies of 5 MHz, 1.7 GHz, 3.4 GHz and 5.1 GHz, corresponding to the zeroth, first, second and third longitudinal modes from the squeezed beam. These results are the highest frequency sideband measurements of squeezing to date. In addition to measuring squeezing at different longitudinal modes for the fundamental Gaussian spatial mode, non-classical noise reduction is measured at the same frequencies for a squeezed higher order spatial mode, TEM10. ¶ A single mode theoretical model of the OPO is presented, based on the work of ref. [1]. Computer simulations of the squeezing predicted by this model are developed and compared to the experimental results, showing excellent agreement between the different longitudinal modes for each of the two spatial modes measured.
Squeezed states are important sources in quantum physics, which have potential applications in fields such as quantum teleportation, quantum information networks, quantum memory, and quantum metrology and precise measurements. For our interest, the squeezed vacuum will be used in the quantum-enhanced optical atomic magnetometers, filling the vacuum port of the probe beam to improve measurement sensitivity. Based on the sub-threshold optical parametric oscillator (OPO) with PPKTP crystal, the squeezed vacuum at rubidium D1 line of 795 nm is obtained. In our work, we investigate the noise sources in an OPO system. By carefully controlling the classical noise source, the squeezing band extends to the analysis frequency of 2.6 kHz. The flat squeezing trace is 2.8 dB below the shot noise limit. In our work, we focus on the difference between the squeezing results at the analysis frequency of kilohertz regime at two different wavelengths, 1064 nm and 795 nm. The difference mainly comes from the absorption of 795 nm laser and its second harmonic at 397.5 nm in crystal (397.5 nm laser is at the edge of transparent window of PPKTP crystal that has an absorption index much higher than at other wavelength). The absorption induced nonlinear loss and thermal instability greatly affect the squeezing results, which is discussed in our work. Squeezing level at 795 nm is worse than at 1064 nm due to the above-mentioned factors. Noise coupling to the detection system limits the squeezing band. In the audio frequency band, squeezing is easily submerged in roll-up noises and the measured squeezing level is limited. Two factors limit the obtained squeezing:the technical noise induced in the detection and the squeezing degradation by the noise coupling of the control beams. In experiment, we carefully control the classical noise at analytical frequency of kilohertz by means of a vacuum-injected OPO, a counter-propagating cavity locking beam with orthogonal polarization, low noise homodyne detector, stable experimental system and quantum noise locking method for squeezing phase locking. Firstly, to preclude the classical noise from coupling the laser source, we use the vacuum injected OPO. A signal beam helps optimize the parametric gain and is blocked in the squeezing measurement process. In order to maintain the OPO, a counter-propagating beam with orthogonal polarization is used for locking the cavity. Then, a low noise balanced homodyne detector with a common-mode rejection ratio of 45 dB helps improve the audio frequency detection. Finally, the quantum noise locking provides a method to lock the relative phase between the coherent beam and the squeezed vacuum field. With the combination of these technical improvements, a squeezed vacuum of 2.8 dB is obtained at the analysis frequency of 2.6-100 kHz. The obtained squeezing level is mainly limited by the relatively large loss in OPO, which is induced by ultra-violet absorption in PPKTP crystal. The generated squeezed field is used to reduce the polarization noise of probe beam in an optical magnetometer, in order to increase detection sensitivity.