Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:quant-ph/0408116 · Physical Review Letters

Quantum Calibration of Measurement Instrumentation

Giacomo Mauro D’Ariano, Lorenzo Maccone, Paoloplacido Lo Presti

Published Dec 16, 2004• 93 citations
arXivHTMLPDF

Abstract

By quantum calibration we name an experimental procedure apt to completely characterize an unknown measurement apparatus by comparing it with a few other calibrated apparatuses. Here we show how to achieve the calibration of an arbitrary measuring apparatus, by using it in combination with a tomographer in a correlation setup with an input bipartite system. The method is robust to imperfections of the tomographer, and works for practically any input state of the bipartite system.

DOI
10.1103/physrevlett.93.250407

Related papers

Blind calibration of a quantum computer

Liam Jeanette, Jadwiga Wilkens, Ingo Roth +4 more

The calibration of quantum measurements is limited by the ability to accurately prepare quantum states under unknown device errors. We develop an accurate calibration protocol for the measurement apparatus of a quantum computer that is `blind' to the state preparation. Blind calibration quantifies and corrects measurement errors from simple tomographic data on a noisy quantum state. Importantly, it calibrates multiple error mechanisms in a single experiment, eliminating the need for bespoke, separate calibration experiments. Using a trapped-ion quantum computer, we systematically demonstrate the accuracy of the method. We use blind calibration to estimate the native calibration parameters of the experimental system. The recovered calibrations are consistent with directly measured values and perform similarly in predicting the state properties.

arXiv:2501.05355•Jan 9, 2025•3 citations

A proposed testbed for detector tomography

Hendrik B. Coldenstrodt-Ronge, Jeff S. Lundeen, Kenny L. Pregnell +7 more

Measurement is the only part of a general quantum system that has yet to be characterised experimentally in a complete manner. Detector tomography provides a procedure for doing just this; an arbitrary measurement device can be fully characterised, and thus calibrated, in a systematic way without access to its components or its design. The result is a reconstructed POVM containing the measurement operators associated with each measurement outcome. We consider two detectors, a single-photon detector and a photon-number counter, and propose an easily realised experimental apparatus to perform detector tomography on them. We also present a method of visualising the resulting measurement operators.

arXiv:0902.4384•Journal of Modern Optics•Oct 31, 2008•41 citations

Quantum process estimation via generic two-body correlations

Masoud Mohseni, A. T. Rezakhani, Julio T. Barreiro +2 more

Performance of quantum process estimation is naturally limited by fundamental, random, and systematic imperfections of preparations and measurements. These imperfections may lead to considerable errors in the process reconstruction because standard data-analysis techniques usually presume ideal devices. Here, by utilizing generic auxiliary quantum or classical correlations, we provide a framework for the estimation of quantum dynamics via a single measurement apparatus. By construction, this approach can be applied to quantum tomography schemes with calibrated faulty-state generators and analyzers. Specifically, we present a generalization of the work begun by M. Mohseni and D. A. Lidar [Phys. Rev. Lett. 97, 170501 (2006)] with an imperfect Bell-state analyzer. We demonstrate that for several physically relevant noisy preparations and measurements, classical correlations and a small data-processing overhead suffice to accomplish the full system identification. Furthermore, we provide the optimal input states whereby the error amplification due to inversion of the measurement data is minimal.

arXiv:0906.3064•Physical Review A•Mar 3, 2010•15 citations

Characterizing Quantum Instruments: From Nondemolition Measurements to Quantum Error Correction

Roman Stricker, Davide Vodola, Alexander Erhard +7 more

A complete toolbox for the tomographic characterization of generic instruments is experimentally applied to detect qubit loss and leakage, offering in-depth information about the failure modes that degrade quantum error correction.

arXiv:2110.06954•PRX Quantum•Aug 3, 2022•13 citations

Measuring measurement: theory and practice

Alejandro Feito, Jeff S. Lundeen, Hendrik B. Coldenstrodt-Ronge +3 more

Recent efforts have applied quantum tomography techniques to the calibration and characterization of complex quantum detectors using minimal assumptions. In this work, we provide detail and insight concerning the formalism, the experimental and theoretical challenges and the scope of these tomographical tools. Our focus is on the detection of photons with avalanche photodiodes and photon-number resolving detectors and our approach is to fully characterize the quantum operators describing these detectors with a minimal set of well-specified assumptions. The formalism is completely general and can be applied to a wide range of detectors.

arXiv:0906.3440•New Journal of Physics•Sep 28, 2009•105 citations

Quantum parameter estimation

Howard M. Wiseman, Gerard J Milburn

Quantum limits to parameter estimation Introduction Many experiments can be thought of as comprising two steps: (i) a preparation procedure in which the system to be measured is isolated and prepared, and the apparatus is initialized; and (ii) a measurement step in which the system is coupled to an apparatus and the measurement result recorded. The preparation procedure can be specified by a set of classical parameters, or settings of a physical device. The measurement results are random classical variables that will be correlated with the preparation procedure. In this chapter we are concerned with the case in which the classical parameters specifying the preparation of the state are imperfectly known. Then, assuming that the physical system is well understood, these correlations allow the unknown parameters to be estimated from the measurement results. As we saw in the last chapter, in quantum mechanics the results of measurements are generally statistical, even when one has complete knowledge of the preparation procedure. A single preparation step and measurement step might not be sufficient to estimate a parameter well. Thus it is common to repeat the two steps of preparation and measurement on a large number of systems, either all at one time or sequentially. Whether measuring one quantum system or many, one is faced with a number of questions. How should one prepare the system state? What sort of measurement should one make on the system?

Cambridge University Press eBooks•Nov 12, 2009•0 citations
By quantum calibration we name an experimental procedure apt to completely characterize an unknown measurement apparatus by comparing it with a few other calibrated apparatuses. Here we show how to achieve the calibration of an arbitrary measuring apparatus, by using it in combination with a tomographer in a correlation setup with an input bipartite system. The method is robust to imperfections of the tomographer, and works for practically any input state of the bipartite system.
The calibration of quantum measurements is limited by the ability to accurately prepare quantum states under unknown device errors. We develop an accurate calibration protocol for the measurement apparatus of a quantum computer that is `blind' to the state preparation. Blind calibration quantifies and corrects measurement errors from simple tomographic data on a noisy quantum state. Importantly, it calibrates multiple error mechanisms in a single experiment, eliminating the need for bespoke, separate calibration experiments. Using a trapped-ion quantum computer, we systematically demonstrate the accuracy of the method. We use blind calibration to estimate the native calibration parameters of the experimental system. The recovered calibrations are consistent with directly measured values and perform similarly in predicting the state properties.
Measurement is the only part of a general quantum system that has yet to be characterised experimentally in a complete manner. Detector tomography provides a procedure for doing just this; an arbitrary measurement device can be fully characterised, and thus calibrated, in a systematic way without access to its components or its design. The result is a reconstructed POVM containing the measurement operators associated with each measurement outcome. We consider two detectors, a single-photon detector and a photon-number counter, and propose an easily realised experimental apparatus to perform detector tomography on them. We also present a method of visualising the resulting measurement operators.
Performance of quantum process estimation is naturally limited by fundamental, random, and systematic imperfections of preparations and measurements. These imperfections may lead to considerable errors in the process reconstruction because standard data-analysis techniques usually presume ideal devices. Here, by utilizing generic auxiliary quantum or classical correlations, we provide a framework for the estimation of quantum dynamics via a single measurement apparatus. By construction, this approach can be applied to quantum tomography schemes with calibrated faulty-state generators and analyzers. Specifically, we present a generalization of the work begun by M. Mohseni and D. A. Lidar [Phys. Rev. Lett. 97, 170501 (2006)] with an imperfect Bell-state analyzer. We demonstrate that for several physically relevant noisy preparations and measurements, classical correlations and a small data-processing overhead suffice to accomplish the full system identification. Furthermore, we provide the optimal input states whereby the error amplification due to inversion of the measurement data is minimal.
Recent efforts have applied quantum tomography techniques to the calibration and characterization of complex quantum detectors using minimal assumptions. In this work, we provide detail and insight concerning the formalism, the experimental and theoretical challenges and the scope of these tomographical tools. Our focus is on the detection of photons with avalanche photodiodes and photon-number resolving detectors and our approach is to fully characterize the quantum operators describing these detectors with a minimal set of well-specified assumptions. The formalism is completely general and can be applied to a wide range of detectors.
Quantum limits to parameter estimation Introduction Many experiments can be thought of as comprising two steps: (i) a preparation procedure in which the system to be measured is isolated and prepared, and the apparatus is initialized; and (ii) a measurement step in which the system is coupled to an apparatus and the measurement result recorded. The preparation procedure can be specified by a set of classical parameters, or settings of a physical device. The measurement results are random classical variables that will be correlated with the preparation procedure. In this chapter we are concerned with the case in which the classical parameters specifying the preparation of the state are imperfectly known. Then, assuming that the physical system is well understood, these correlations allow the unknown parameters to be estimated from the measurement results. As we saw in the last chapter, in quantum mechanics the results of measurements are generally statistical, even when one has complete knowledge of the preparation procedure. A single preparation step and measurement step might not be sufficient to estimate a parameter well. Thus it is common to repeat the two steps of preparation and measurement on a large number of systems, either all at one time or sequentially. Whether measuring one quantum system or many, one is faced with a number of questions. How should one prepare the system state? What sort of measurement should one make on the system?