arXiv:quant-ph/0306116 · Physical Review A

Simultaneous near-field and far-field spatial quantum correlations in the high-gain regime of parametric down-conversion

E. Brambilla, A. Gatti, Morten Bache, Luigi A. Lugiato

Published Feb 9, 2004• 201 citations
arXivHTMLPDF

Abstract

We study the spatial correlations of quantum fluctuations that can be observed in multimode parametric down-conversion in the regime of high gain. We investigate both a type-I and a type-II phase-matching configuration: in the latter case spatial correlations at the quantum level are shown to exist both in the near-field and in the far-field zones of the down-converted light. In the stationary and plane-wave approximation we treat the problem analytically. A stochastic model is solved numerically to obtain quantitative results beyond this approximation. The finite transverse size and pulse duration of the pump beam and other features of the system, such as spatial walk-off and diffraction are taken into account, and we show that correlations beyond the standard quantum limit exist for values of parameters consistent with realistic experiments.

DOI
10.1103/physreva.69.023802

Related papers

Detection of Sub-Shot-Noise Spatial Correlation in High-Gain Parametric Down Conversion

Ottavia Jedrkiewicz, Yun-Kun Jiang, E. Brambilla +4 more

Using a 1 GW, 1 ps pump laser pulse in high-gain parametric down conversion allows us to detect sub-shot-noise spatial quantum correlation with up to 100 photoelectrons per mode by means of a high efficiency charge coupled device. The statistics is performed in single shot over independent spatial replica of the system. Evident quantum correlations were observed between symmetrical signal and idler spatial areas in the far field. In accordance with the predictions of numerical calculations, the observed transition from the quantum to the classical regime is interpreted as a consequence of the narrowing of the down-converted beams in the very high-gain regime.

arXiv:quant-ph/0407211•Physical Review Letters•Dec 6, 2004•206 citations

Spatial and temporal coherence in optical parametric devices pumped with multimode beams

Valdas Pašiškevičius, V. Smilgevičius, Rytis Butkus +2 more

We investigate the emergence of spatial and temporal coherence for the fields in the noncritical nondegenerate parametric second-order down-conversion process pumped with low spatial and temporal coherence beams. It is shown that in this scenario, which is of considerable practical importance, the parametric gain in the near field breaks down into an ensemble of mutually incoherent beamlets containing parametric waves. The field generated in a single beamlet is fully spatially coherent. The size of such coherent parametric gain regions is governed by the near-field spatial coherence radius of the pump, which also acts as a parameter, restraining the linear diffraction of the parametric waves generated in the nonlinear interaction. Furthermore, we experimentally demonstrate how the spatial and temporal coherence can be substantially enhanced by manipulating the spatial field correlation of the multilongitudinal and multi-transversal mode pump.

Lithuanian Journal of Physics•Mar 28, 2018•0 citations

Quantum spatial correlations in high-gain parametric down-conversion measured by means of a CCD camera

O. Jedrkiewicz, E. Brambilla, M. Bache +3 more

We consider travelling-wave parametric down-conversion in the high-gain regime and present the experimental demonstration of the quantum character of the spatial fluctuations in the system. In addition to showing the presence of sub-shot noise fluctuations in the intensity difference, we demonstrate that the peak value of the normalized spatial correlations between signal and idler lies well above the line marking the boundary between the classical and the quantum domain. This effect is equivalent to the apparent violation of the Cauchy–Schwartz inequality, predicted by some of us years ago, which represents a spatial analogue of photon antibunching in time. Finally, we analyse numerically the transition from the quantum to the classical regime when the gain is increased and we emphasize the role of the inaccuracy in the determination of the symmetry centre of the signal–idler pattern in the far-field plane.

arXiv:quant-ph/0502047•Journal of Modern Optics•Feb 21, 2006•23 citations

Quantifying the non-Gaussianity of the state of spatially correlated down-converted photons

E. S. Gómez, W. A. T. Nogueira, Carlos Henrique Monken +1 more

The state of spatially correlated down-converted photons is usually treated as a two-mode Gaussian entangled state. While intuitively this seems to be reasonable, it is known that new structures in the spatial distributions of these photons can be observed when the phase-matching conditions are properly taken into account. Here, we study how the variances of the near- and far-field conditional probabilities are affected by the phase-matching functions, and we analyze the role of the EPR-criterion regarding the non-Gaussianity and entanglement detection of the spatial two-photon state of spontaneous parametric down-conversion (SPDC). Then we introduce a statistical measure, based on the negentropy of the joint distributions at the near- and far-field planes, which allows for the quantification of the non-Gaussianity of this state. This measure of non-Gaussianity requires only the measurement of the diagonal covariance sub-matrices, and will be relevant for new applications of the spatial correlation of SPDC in CV quantum information processing.

arXiv:1111.4006•Optics Express•Jan 31, 2012•10 citations

Quantum correlation between optical and terahertz photons generated under multimode spontaneous parametric down-conversion

G. Kh. Kitaeva, A.A. Leontyev, Pavel A. Prudkovskii

We study conditions for the generation of strongly correlated photons of two extremely different frequency ranges, optical and terahertz, via the spontaneous parametric down-conversion effect in a nonlinear medium. Analytical expressions for the correlation function are derived using equations of the generalized Kirchhoff law for the second-order field moments with account of both classical thermal and quantum vacuum field fluctuations, possible inherent absorption of the medium at terahertz frequencies, and angular divergences of signal and idler radiation caused by a transverse limited spatial profile of the Gaussian pump beam. Associated with the current absence of terahertz photon counting detectors and coincidence schemes, the possible experimental limitations in measuring the second-order optical-terahertz field correlations are studied. Numerical calculations of noncollinear eee-geometry parametric down-conversion in a $\mathrm{Mg}:\mathrm{LiNb}{\mathrm{O}}_{3}$ crystal demonstrate angular characteristics, particular features of the temperature and spectral behavior of the second-order quantum correlation function of optical-terahertz biphotons.

Physical Review A•May 4, 2020•15 citations

Modeling the space-time correlation of pulsed twin beams

A. Gatti, Ottavia Jedrkiewicz, E. Brambilla

Entangled twin-beams generated by parametric down-conversion are among the favorite sources for imaging-oriented applications, due their multimodal nature in space and time. However, a satisfactory theoretical description is still lacking. In this work we propose a semi-analytic model which aims to bridge the gap between time-consuming numerical simulations and the unrealistic plane-wave pump theory. The model is used to study the quantum correlation and the coherence in the angle-frequency domain of the parametric emission, and demonstrates a [Formula: see text] growth of their size as the gain g increases, with a corresponding contraction of the space-time distribution. These predictions are systematically compared with the results of stochastic numerical simulations, performed in the Wigner representation, of the full model equations: an excellent agreement is shown even for parameters well outside the expected limit of validity of the model.

arXiv:2301.07441•Scientific Reports•Oct 5, 2023•11 citations
We study the spatial correlations of quantum fluctuations that can be observed in multimode parametric down-conversion in the regime of high gain. We investigate both a type-I and a type-II phase-matching configuration: in the latter case spatial correlations at the quantum level are shown to exist both in the near-field and in the far-field zones of the down-converted light. In the stationary and plane-wave approximation we treat the problem analytically. A stochastic model is solved numerically to obtain quantitative results beyond this approximation. The finite transverse size and pulse duration of the pump beam and other features of the system, such as spatial walk-off and diffraction are taken into account, and we show that correlations beyond the standard quantum limit exist for values of parameters consistent with realistic experiments.
Using a 1 GW, 1 ps pump laser pulse in high-gain parametric down conversion allows us to detect sub-shot-noise spatial quantum correlation with up to 100 photoelectrons per mode by means of a high efficiency charge coupled device. The statistics is performed in single shot over independent spatial replica of the system. Evident quantum correlations were observed between symmetrical signal and idler spatial areas in the far field. In accordance with the predictions of numerical calculations, the observed transition from the quantum to the classical regime is interpreted as a consequence of the narrowing of the down-converted beams in the very high-gain regime.
We investigate the emergence of spatial and temporal coherence for the fields in the noncritical nondegenerate parametric second-order down-conversion process pumped with low spatial and temporal coherence beams. It is shown that in this scenario, which is of considerable practical importance, the parametric gain in the near field breaks down into an ensemble of mutually incoherent beamlets containing parametric waves. The field generated in a single beamlet is fully spatially coherent. The size of such coherent parametric gain regions is governed by the near-field spatial coherence radius of the pump, which also acts as a parameter, restraining the linear diffraction of the parametric waves generated in the nonlinear interaction. Furthermore, we experimentally demonstrate how the spatial and temporal coherence can be substantially enhanced by manipulating the spatial field correlation of the multilongitudinal and multi-transversal mode pump.
We consider travelling-wave parametric down-conversion in the high-gain regime and present the experimental demonstration of the quantum character of the spatial fluctuations in the system. In addition to showing the presence of sub-shot noise fluctuations in the intensity difference, we demonstrate that the peak value of the normalized spatial correlations between signal and idler lies well above the line marking the boundary between the classical and the quantum domain. This effect is equivalent to the apparent violation of the Cauchy–Schwartz inequality, predicted by some of us years ago, which represents a spatial analogue of photon antibunching in time. Finally, we analyse numerically the transition from the quantum to the classical regime when the gain is increased and we emphasize the role of the inaccuracy in the determination of the symmetry centre of the signal–idler pattern in the far-field plane.
The state of spatially correlated down-converted photons is usually treated as a two-mode Gaussian entangled state. While intuitively this seems to be reasonable, it is known that new structures in the spatial distributions of these photons can be observed when the phase-matching conditions are properly taken into account. Here, we study how the variances of the near- and far-field conditional probabilities are affected by the phase-matching functions, and we analyze the role of the EPR-criterion regarding the non-Gaussianity and entanglement detection of the spatial two-photon state of spontaneous parametric down-conversion (SPDC). Then we introduce a statistical measure, based on the negentropy of the joint distributions at the near- and far-field planes, which allows for the quantification of the non-Gaussianity of this state. This measure of non-Gaussianity requires only the measurement of the diagonal covariance sub-matrices, and will be relevant for new applications of the spatial correlation of SPDC in CV quantum information processing.
We study conditions for the generation of strongly correlated photons of two extremely different frequency ranges, optical and terahertz, via the spontaneous parametric down-conversion effect in a nonlinear medium. Analytical expressions for the correlation function are derived using equations of the generalized Kirchhoff law for the second-order field moments with account of both classical thermal and quantum vacuum field fluctuations, possible inherent absorption of the medium at terahertz frequencies, and angular divergences of signal and idler radiation caused by a transverse limited spatial profile of the Gaussian pump beam. Associated with the current absence of terahertz photon counting detectors and coincidence schemes, the possible experimental limitations in measuring the second-order optical-terahertz field correlations are studied. Numerical calculations of noncollinear eee-geometry parametric down-conversion in a Mg:LiNbO3\mathrm{Mg}:\mathrm{LiNb}{\mathrm{O}}_{3}Mg:LiNbO3​ crystal demonstrate angular characteristics, particular features of the temperature and spectral behavior of the second-order quantum correlation function of optical-terahertz biphotons.
Entangled twin-beams generated by parametric down-conversion are among the favorite sources for imaging-oriented applications, due their multimodal nature in space and time. However, a satisfactory theoretical description is still lacking. In this work we propose a semi-analytic model which aims to bridge the gap between time-consuming numerical simulations and the unrealistic plane-wave pump theory. The model is used to study the quantum correlation and the coherence in the angle-frequency domain of the parametric emission, and demonstrates a [Formula: see text] growth of their size as the gain g increases, with a corresponding contraction of the space-time distribution. These predictions are systematically compared with the results of stochastic numerical simulations, performed in the Wigner representation, of the full model equations: an excellent agreement is shown even for parameters well outside the expected limit of validity of the model.