arXiv:1111.4006 · Optics Express

Quantifying the non-Gaussianity of the state of spatially correlated down-converted photons

E. S. Gómez, W. A. T. Nogueira, Carlos Henrique Monken, G. Lima

Published Jan 31, 2012• 10 citations
arXivHTMLPDF

Abstract

The state of spatially correlated down-converted photons is usually treated as a two-mode Gaussian entangled state. While intuitively this seems to be reasonable, it is known that new structures in the spatial distributions of these photons can be observed when the phase-matching conditions are properly taken into account. Here, we study how the variances of the near- and far-field conditional probabilities are affected by the phase-matching functions, and we analyze the role of the EPR-criterion regarding the non-Gaussianity and entanglement detection of the spatial two-photon state of spontaneous parametric down-conversion (SPDC). Then we introduce a statistical measure, based on the negentropy of the joint distributions at the near- and far-field planes, which allows for the quantification of the non-Gaussianity of this state. This measure of non-Gaussianity requires only the measurement of the diagonal covariance sub-matrices, and will be relevant for new applications of the spatial correlation of SPDC in CV quantum information processing.

DOI
10.1364/oe.20.003753

Related papers

Unveiling quantum correlations of SPDC biphoton spatial modes using spatial light modulator

Omshankar, Vivek Venkataraman, Joyee Ghosh

Abstract We experimentally demonstrate the quantum entanglement in various spatial modes of the correlated photons generated via spontaneous parametric down-conversion in a type-II phase-matched periodically-poled KTP crystal. The two-fold coincidence measurement reveals the spatial entanglement between the photon pairs by projecting one of the correlated photons onto a Gaussian mode while scanning the spatial mode of its partner photon through selective projection (Gaussian, Laguerre–Gaussian (LG), Bessel-Gaussian (BG), and Airy–Gaussian (AG)) using a spatial light modulator (SLM). We also show the spatially resolved measurement of the non-conservation of orbital angular momentum via modal decomposition of the correlated photon in LG and BG bases.

Journal of Optics•Oct 22, 2024•3 citations

Photon statistics and spatial properties of photon pairs generated by spontaneous parametric down-conversion

Martin Hamar, Jan Peřina, Ondřej Haderka

Measurement of photon-number statistics of fields composed of photon pairs generated in spontaneous parametric down-conversion pumped by strong ultrashort pulses is described. Finite detection quantum efficiencies, noises as well as possible loss of one or both photons from a pair are taken into account. Measured data provided by an intensified CCD camera are analyzed along the developed model. The joint signal-idler photon-number distribution is obtained using the expectation maximization algorithm. Covariance of the signal and idler photon-numbers exceeds 98%. Entanglement area of the correlated photon pairs is determined.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 15, 2005•0 citations

Full field measurement of spatial correlated photon pairs with an EMCCD camera

M. Edgar, D. S. Tasca, Frauke Izdebski +5 more

The spatial correlations between the photon pairs produced by spontaneous parametric down conversion (SPDC) have been investigated in a number of different configurations over the last two decades (1). The high dimensionality of the transverse spatial degrees of freedom (DOF) of the photon pairs can be explored either by projections onto a discrete (infinite) basis, such as the LG modes, or by using a continuous basis defined by the transverse position or momentum of the photons. For instance, it has been shown that their transverse position and momentum display EPR-type correlations (2). Despite the continuous and unbounded nature of both these bases, the most common measurements to date have relied upon the scanning of a single avalanche photodiode or a very small number of individual detectors. This sequential scanning or small number of detectors negates any information capacity advantage in the use of spatial states. Recent years have seen a rapid advance in imaging technologies, particularly for low light levels. Of these technologies the highest quantum efficiency is achieved using electron multiplying CCDs (EMCCD). Developments in low noise EMCCD cameras suggest they are capable of greater than 80% quantum efficiencies and if operated in an ultra-low light environment whilst being maintained at low temperatures, can provide single photon sensitivity (3). EMCCDs have been used in measurements of sub-shot-noise correlations of intensity fluctuations (4, 5) as well as in intensity correlations measurements (6) in the far field of the photon pairs from SPDC. Here we report the observation of spatial correlations from SPDC using an EMCCD camera in both the image and far-field planes of the down conversion crystal. We pump a BBO crystal at 355nm with a few milli-Watts of optical power and use a simple lens system to relay the down-converted light to an EMCCD array which can be positioned in either the image plane or the far-field of the crystal. Our photon flux is around 1/100 per pixel, which approximately doubles the signal obtained when the light is blocked. We typically record 100,000 individual frames and then sum the auto-correlation of the individual frames. We observed intensity correlation and anti-correlation in the image and far-field planes, respectively. In both cases we make the correlations more visible by subtracting a background which is obtained as the average correlation obtained between successive frames. Using this approach we are able to visualize the strength of the correlations in both position and momentum, showing a variance product nearly one order of magnitude below the classical limit in both x and y directions.

•Jan 1, 2012•0 citations

Transverse distinguishability of entangled photons with arbitrarily shaped spatial near- and far-field distributions

Robert Elsner, Dirk Puhlmann, Gregor Pieplow +2 more

Entangled photons generated by spontaneous parametric downconversion are ubiquitous in quantum optics. In general, they exhibit a complex spatial photon count distribution. This spatial structure is responsible for seemingly surprising results concerning, e.g., complementarity such as the apparent simultaneous observation of interference fringes V and which-way information D at a double slit, as recently reported by Menzel et al. [Proc. Natl. Acad. Sci. USA109, 9314 (2012)10.1073/pnas.1201271109PNASA60027-8424]. We implement a complete quantitative model of the SPDC interaction that fully incorporates the effects of crystal anisotropies, phase matching, and the pump beam structure and allows for arbitrary manipulations of the SPDC light in the near and far fields. This enables us to establish an upper bound D2+V2≤1.47 for the experimental parameters reported by Menzel et al. We report new experimental results that agree excellently with these theoretical predictions. The new model enables a detailed quantitative analysis of this surprising result and the fair sampling interpretation of biphotons passing a double slit.

arXiv:1409.6990•Journal of the Optical Society of America B•Aug 17, 2015•3 citations

Image-Plane Detection of Spatially Entangled Photon Pairs with a CMOS Camera

David McFadden, Rainer Heintzmann

Spatially entangled photon pairs (biphotons) generated by spontaneous parametric down-conversion offer unique opportunities for quantum imaging, but image-plane biphoton correlations are difficult to observe with camera-based detectors. Previous camera-based biphoton imaging experiments have relied on photon-counting detection, which necessitates operation deep in the photon-sparse regime and requires extremely low dark rates. Here, we demonstrate the detection of spatial biphoton joint probability distributions in both the image plane and the pupil plane (also termed "near-field plane" and "far-field plane" respectively) using a conventional scientific CMOS camera operated in linear mode. We work at mesoscopic intensity levels, corresponding to a photon flux approximately four orders of magnitude higher than typical photon-counting approaches. From the measured image- and pupil plane correlations, we observe position and momentum correlations consistent with an EPR-type entanglement witness. A tailored correlation analysis suited for image plane imaging suppresses detector artifacts and intensity fluctuations, enabling acquisition with significantly fewer frames. Our results demonstrate that spatially entangled-light imaging can be performed efficiently with standard imaging hardware, extending quantum imaging techniques beyond the photon-counting regime.

quant-pharXiv:2512.24878•Jan 1, 2026•0 citations

Tunable entanglement distillation of spatially correlated down-converted photons

Esteban S. Gómez, P. Riquelme, M. A. Solís-Prosser +4 more

We report on a new technique for entanglement distillation of the bipartite continuous variable state of spatially correlated photons generated in the spontaneous parametric down-conversion process (SPDC), where tunable non-Gaussian operations are implemented and the post-processed entanglement is certified in real-time using a single-photon sensitive electron multiplying CCD (EMCCD) camera. The local operations are performed using non-Gaussian filters modulated into a programmable spatial light modulator and, by using the EMCCD camera for actively recording the probability distributions of the twin-photons, one has fine control of the Schmidt number of the distilled state. We show that even simple non-Gaussian filters can be finely tuned to a ∼67% net gain of the initial entanglement generated in the SPDC process.

arXiv:1805.06577•Optics Express•May 16, 2018•1 citation
The state of spatially correlated down-converted photons is usually treated as a two-mode Gaussian entangled state. While intuitively this seems to be reasonable, it is known that new structures in the spatial distributions of these photons can be observed when the phase-matching conditions are properly taken into account. Here, we study how the variances of the near- and far-field conditional probabilities are affected by the phase-matching functions, and we analyze the role of the EPR-criterion regarding the non-Gaussianity and entanglement detection of the spatial two-photon state of spontaneous parametric down-conversion (SPDC). Then we introduce a statistical measure, based on the negentropy of the joint distributions at the near- and far-field planes, which allows for the quantification of the non-Gaussianity of this state. This measure of non-Gaussianity requires only the measurement of the diagonal covariance sub-matrices, and will be relevant for new applications of the spatial correlation of SPDC in CV quantum information processing.
Abstract We experimentally demonstrate the quantum entanglement in various spatial modes of the correlated photons generated via spontaneous parametric down-conversion in a type-II phase-matched periodically-poled KTP crystal. The two-fold coincidence measurement reveals the spatial entanglement between the photon pairs by projecting one of the correlated photons onto a Gaussian mode while scanning the spatial mode of its partner photon through selective projection (Gaussian, Laguerre–Gaussian (LG), Bessel-Gaussian (BG), and Airy–Gaussian (AG)) using a spatial light modulator (SLM). We also show the spatially resolved measurement of the non-conservation of orbital angular momentum via modal decomposition of the correlated photon in LG and BG bases.
Measurement of photon-number statistics of fields composed of photon pairs generated in spontaneous parametric down-conversion pumped by strong ultrashort pulses is described. Finite detection quantum efficiencies, noises as well as possible loss of one or both photons from a pair are taken into account. Measured data provided by an intensified CCD camera are analyzed along the developed model. The joint signal-idler photon-number distribution is obtained using the expectation maximization algorithm. Covariance of the signal and idler photon-numbers exceeds 98%. Entanglement area of the correlated photon pairs is determined.
The spatial correlations between the photon pairs produced by spontaneous parametric down conversion (SPDC) have been investigated in a number of different configurations over the last two decades (1). The high dimensionality of the transverse spatial degrees of freedom (DOF) of the photon pairs can be explored either by projections onto a discrete (infinite) basis, such as the LG modes, or by using a continuous basis defined by the transverse position or momentum of the photons. For instance, it has been shown that their transverse position and momentum display EPR-type correlations (2). Despite the continuous and unbounded nature of both these bases, the most common measurements to date have relied upon the scanning of a single avalanche photodiode or a very small number of individual detectors. This sequential scanning or small number of detectors negates any information capacity advantage in the use of spatial states. Recent years have seen a rapid advance in imaging technologies, particularly for low light levels. Of these technologies the highest quantum efficiency is achieved using electron multiplying CCDs (EMCCD). Developments in low noise EMCCD cameras suggest they are capable of greater than 80% quantum efficiencies and if operated in an ultra-low light environment whilst being maintained at low temperatures, can provide single photon sensitivity (3). EMCCDs have been used in measurements of sub-shot-noise correlations of intensity fluctuations (4, 5) as well as in intensity correlations measurements (6) in the far field of the photon pairs from SPDC. Here we report the observation of spatial correlations from SPDC using an EMCCD camera in both the image and far-field planes of the down conversion crystal. We pump a BBO crystal at 355nm with a few milli-Watts of optical power and use a simple lens system to relay the down-converted light to an EMCCD array which can be positioned in either the image plane or the far-field of the crystal. Our photon flux is around 1/100 per pixel, which approximately doubles the signal obtained when the light is blocked. We typically record 100,000 individual frames and then sum the auto-correlation of the individual frames. We observed intensity correlation and anti-correlation in the image and far-field planes, respectively. In both cases we make the correlations more visible by subtracting a background which is obtained as the average correlation obtained between successive frames. Using this approach we are able to visualize the strength of the correlations in both position and momentum, showing a variance product nearly one order of magnitude below the classical limit in both x and y directions.
Entangled photons generated by spontaneous parametric downconversion are ubiquitous in quantum optics. In general, they exhibit a complex spatial photon count distribution. This spatial structure is responsible for seemingly surprising results concerning, e.g., complementarity such as the apparent simultaneous observation of interference fringes V and which-way information D at a double slit, as recently reported by Menzel et al. [Proc. Natl. Acad. Sci. USA109, 9314 (2012)10.1073/pnas.1201271109PNASA60027-8424]. We implement a complete quantitative model of the SPDC interaction that fully incorporates the effects of crystal anisotropies, phase matching, and the pump beam structure and allows for arbitrary manipulations of the SPDC light in the near and far fields. This enables us to establish an upper bound D2+V2≤1.47 for the experimental parameters reported by Menzel et al. We report new experimental results that agree excellently with these theoretical predictions. The new model enables a detailed quantitative analysis of this surprising result and the fair sampling interpretation of biphotons passing a double slit.
Spatially entangled photon pairs (biphotons) generated by spontaneous parametric down-conversion offer unique opportunities for quantum imaging, but image-plane biphoton correlations are difficult to observe with camera-based detectors. Previous camera-based biphoton imaging experiments have relied on photon-counting detection, which necessitates operation deep in the photon-sparse regime and requires extremely low dark rates. Here, we demonstrate the detection of spatial biphoton joint probability distributions in both the image plane and the pupil plane (also termed "near-field plane" and "far-field plane" respectively) using a conventional scientific CMOS camera operated in linear mode. We work at mesoscopic intensity levels, corresponding to a photon flux approximately four orders of magnitude higher than typical photon-counting approaches. From the measured image- and pupil plane correlations, we observe position and momentum correlations consistent with an EPR-type entanglement witness. A tailored correlation analysis suited for image plane imaging suppresses detector artifacts and intensity fluctuations, enabling acquisition with significantly fewer frames. Our results demonstrate that spatially entangled-light imaging can be performed efficiently with standard imaging hardware, extending quantum imaging techniques beyond the photon-counting regime.
We report on a new technique for entanglement distillation of the bipartite continuous variable state of spatially correlated photons generated in the spontaneous parametric down-conversion process (SPDC), where tunable non-Gaussian operations are implemented and the post-processed entanglement is certified in real-time using a single-photon sensitive electron multiplying CCD (EMCCD) camera. The local operations are performed using non-Gaussian filters modulated into a programmable spatial light modulator and, by using the EMCCD camera for actively recording the probability distributions of the twin-photons, one has fine control of the Schmidt number of the distilled state. We show that even simple non-Gaussian filters can be finely tuned to a ∼67% net gain of the initial entanglement generated in the SPDC process.