arXiv:quant-ph/0111052 · Applied Physics B

High-contrast Mach–Zehnder lithium-atom interferometer in the Bragg regime

R. Delhuille, C. Champenois, M Büchner, Leszek Jozefowski, Carlo Rizzo, G. Trénec, J. Vigué

Published Apr 1, 2002• 29 citations
arXivHTMLPDF
DOI
10.1007/s003400200840

Related papers

Fringe Contrast in Mach--Zehnder Atom Interferometers

R. Delhuille, Alain Miffre, B. Viaris de Lesegno +4 more

Acta Physica Polonica B•Aug 1, 2002•2 citations

Mach-Zehnder Bragg interferometer for a Bose-Einstein condensate

上妻 幹男, Mikio Kozuma

•Jan 1, 2000•0 citations

Fringe contrast in three grating Mach-Zehnder atomic interferometers

C. Champenois, M Büchner, J. Vigué

The European Physical Journal D•Feb 1, 1999•22 citations

Some theoretical and experimental aspects of three-grating Mach–Zehnder atom interferometers

R. Delhuille, C. Champenois, M Büchner +8 more

Comptes Rendus de l Académie des Sciences - Series IV - Physics-Astrophysics•Jun 1, 2001•0 citations

An atom interferometer using thermal lithium atoms

Alain Miffre, Marion Jacquey, R. Delhuille +4 more

Abstract. We have built an atom interferometer of the Mach-Zehnder type, operating with thermal lithium atoms [1]. Its design is largely inspired by previous works done by the groups of D. Pritchard [2], A. Zeilinger [3] and S.A. Lee [4]. In our apparatus, the atomic wave is diffracted in the Bragg regime by three laser sanding waves to achieve a Mach-Zehnder configuration. This paper briefly recalls the diffraction process and shows the experimental results obtained in our group. Our apparatus is able to achieve a high fringe contrast of 74 % with a large mean detected atom flux of 1.5 × 104 s-1. Finally, the paper ends with the measurement of the velocity distribution of our lithium beam using a light induced fluorescence technique. 1. DIFFRACTION OF THE LITHIUM ATOMIC WAVE IN THE BRAGG REGIME Diffraction of an atomic wave by a laser standing wave in the Bragg regime is in complete analogy with diffraction of x-rays by a crystal. The laser standing wave acts as a thick phase grating for the atomic wave with a periodicity of half the laser wavelength λ r. The diffraction process is governed by conservation of momentum and energy. With a thick laser wave, momentum is transferred from the laser to the incident atomic wave only when the Bragg condition λr sin(θB) = pλdB is fulfilled, where θB is the Bragg angle and p is the diffraction order. For lithium, λr = 671 nm, and the first order diffraction angle is θ1 = 2θB = 170 µrad. Diffraction of the lithium atomic wave is seen by tuning the angle i between the mirror and the atomic beam axis as shown in figure 1a. Figure 1b presents the zero-order beam intensity measured with our detector. This signal is symmetrical around the beam axis and the Bragg condition is fulfilled for ±1 diffraction orders. Figure 1a. Experimental set-up for Bragg diffraction. Figure 1b. Zero-order beam intensity as a function of the angle i between the mirror and the beam axis.

Journal de Physique IV (Proceedings)•Nov 1, 2004•0 citations

Mach-Zehnder Bragg interferometer for a Bose-Einstein condensate

Yoshio Torii, Yoichi Suzuki, Mikio Kozuma +4 more

We construct a Mach-Zehnder interferometer using Bose-Einstein condensed rubidium atoms and optical Bragg diffraction. In contrast to interferometers based on normal diffraction, where only a small percentage of the atoms contribute to the signal, our Bragg diffraction interferometer uses all the condensate atoms. The condensate coherence properties and high phase-space density result in an interference pattern of nearly 100% contrast. The two arms of the interferometer may be completely separated in space, making it an ideal tool that can be used to detect vortices or other topological condensate phases.

arXiv:cond-mat/9908160•Physical Review A•Feb 28, 2000•140 citations
Abstract. We have built an atom interferometer of the Mach-Zehnder type, operating with thermal lithium atoms [1]. Its design is largely inspired by previous works done by the groups of D. Pritchard [2], A. Zeilinger [3] and S.A. Lee [4]. In our apparatus, the atomic wave is diffracted in the Bragg regime by three laser sanding waves to achieve a Mach-Zehnder configuration. This paper briefly recalls the diffraction process and shows the experimental results obtained in our group. Our apparatus is able to achieve a high fringe contrast of 74 % with a large mean detected atom flux of 1.5 × 104 s-1. Finally, the paper ends with the measurement of the velocity distribution of our lithium beam using a light induced fluorescence technique. 1. DIFFRACTION OF THE LITHIUM ATOMIC WAVE IN THE BRAGG REGIME Diffraction of an atomic wave by a laser standing wave in the Bragg regime is in complete analogy with diffraction of x-rays by a crystal. The laser standing wave acts as a thick phase grating for the atomic wave with a periodicity of half the laser wavelength λ r. The diffraction process is governed by conservation of momentum and energy. With a thick laser wave, momentum is transferred from the laser to the incident atomic wave only when the Bragg condition λr sin(θB) = pλdB is fulfilled, where θB is the Bragg angle and p is the diffraction order. For lithium, λr = 671 nm, and the first order diffraction angle is θ1 = 2θB = 170 µrad. Diffraction of the lithium atomic wave is seen by tuning the angle i between the mirror and the atomic beam axis as shown in figure 1a. Figure 1b presents the zero-order beam intensity measured with our detector. This signal is symmetrical around the beam axis and the Bragg condition is fulfilled for ±1 diffraction orders. Figure 1a. Experimental set-up for Bragg diffraction. Figure 1b. Zero-order beam intensity as a function of the angle i between the mirror and the beam axis.
We construct a Mach-Zehnder interferometer using Bose-Einstein condensed rubidium atoms and optical Bragg diffraction. In contrast to interferometers based on normal diffraction, where only a small percentage of the atoms contribute to the signal, our Bragg diffraction interferometer uses all the condensate atoms. The condensate coherence properties and high phase-space density result in an interference pattern of nearly 100% contrast. The two arms of the interferometer may be completely separated in space, making it an ideal tool that can be used to detect vortices or other topological condensate phases.