Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:physics/0407125

AC Stark shift noise in QND measurement arising from quantum fluctuations of light polarization

Marcis P. Auzinsh, Dmitry Budker, DF Kimball, S M Rochester, J. E. Stalnaker, Alexander O. Sushkov, VV Yashchuk

Published Jul 24, 2004• 1 citation
arXivHTMLPDF

Abstract

In a recent letter [Auzinsh {\it{et. al.}} (physics/0403097)] we have analyzed the noise properties of an idealized atomic magnetometer that utilizes spin squeezing induced by a continuous quantum nondemolition measurement. Such a magnetometer measures spin precession of $N$ atomic spins by detecting optical rotation of far-detuned probe light. Here we consider maximally squeezed probe light, and carry out a detailed derivation of the contribution to the noise in a magnetometric measurement due to the differential AC Stark shift between Zeeman sublevels arising from quantum fluctuations of the probe polarization.

DOI
10.48550/arxiv.physics/0407125

Related papers

Can a Quantum Nondemolition Measurement Improve the Sensitivity of an Atomic Magnetometer?

Marcis P. Auzinsh, Dmitry Budker, Derek F. Jackson Kimball +4 more

We consider the limitations due to noise (e.g., quantum projection noise and photon shot-noise) on the sensitivity of an idealized atomic magnetometer that utilizes spin squeezing induced by a continuous quantum nondemolition measurement. Such a magnetometer measures spin precession of $N$ atomic spins by detecting optical rotation of far-detuned light. We show that for very short measurement times, the optimal sensitivity scales as ${N}^{\ensuremath{-}3/4}$; if strongly squeezed probe light is used, the Heisenberg limit of ${N}^{\ensuremath{-}1}$ scaling can be achieved. However, if the measurement time exceeds ${\ensuremath{\tau}}_{\mathrm{r}\mathrm{e}\mathrm{l}}/{N}^{1/2}$ in the former case, or ${\ensuremath{\tau}}_{\mathrm{r}\mathrm{e}\mathrm{l}}/N$ in the latter, where ${\ensuremath{\tau}}_{\mathrm{r}\mathrm{e}\mathrm{l}}$ is the spin relaxation time, the scaling becomes ${N}^{\ensuremath{-}1/2}$, as for a standard shot-noise-limited magnetometer.

arXiv:physics/0403097•Physical Review Letters•Oct 19, 2004•153 citations

Quantum-noise-limited interferometric measurement of atomic noise: Towards spin squeezing on the Cs clock transition

Daniel Oblak, Plamen G. Petrov, Carlos L. Garrido Alzar +5 more

We investigate theoretically and experimentally a nondestructive interferometric measurement of the state population of an ensemble of laser-cooled and trapped atoms. This study is a step toward generation of (pseudo)spin squeezing of cold atoms targeted at the improvement of the cesium clock performance beyond the limit set by the quantum projection noise of atoms. We calculate the phase shift and the quantum noise of a near-resonant optical probe pulse propagating through a cloud of cold $^{133}\mathrm{Cs}$ atoms. We analyze the figure of merit for a quantum nondemolition (QND) measurement of the collective pseudospin and show that it can be expressed simply as a product of the ensemble optical density and the pulse-integrated rate of the spontaneous emission caused by the off-resonant probe light. Based on this, we propose a protocol for the sequence of operations required to generate and utilize spin squeezing for the improved atomic clock performance via a QND measurement on the probe light. In the experimental part we demonstrate that the interferometric measurement of the atomic population can reach a sensitivity of the order of $\sqrt{{N}_{\mathrm{at}}}$ in a cloud of ${N}_{\mathrm{at}}$ cold atoms, which is an important benchmark toward the experimental realization of the theoretically analyzed protocol.

arXiv:quant-ph/0312165•Physical Review A•Apr 11, 2005•80 citations

Quantum limit of optical magnetometry in the presence of ac Stark shifts

Michael Fleischhauer, Andrey B. Matsko, Marlan O. Scully

We analyze systematic (classical) and fundamental (quantum) limitations of the sensitivity of optical magnetometers resulting from ac Stark shifts. We show that in contrast to absorption-based techniques, the signal reduction associated with classical broadening can be compensated in magnetometers based on phase measurements using electromagnetically induced transparency (EIT). However due to ac Stark--associated quantum noise the signal-to-noise ratio of EIT-based magnetometers attains a maximum value at a certain laser intensity. This value is independent on the quantum statistics of the light and defines a standard quantum limit of sensitivity. We demonstrate that an EIT-based optical magnetometer in Faraday configuration is the best candidate to achieve the highest sensitivity of magnetic-field detection and give a detailed analysis of such a device.

arXiv:quant-ph/0001072•Physical Review A•Jun 14, 2000•129 citations

Diffusive suppression of AC-Stark shifts in atomic magnetometers

Ibrahim Sulai, R. Wyllie, Matt Kauer +3 more

In atomic magnetometers, the vector AC-Stark shift associated with circularly polarized light generates spatially varying effective magnetic fields, which limit the magnetometer response and serve as sources of noise. We describe a scheme whereby optically pumping a small subvolume of the magnetometer cell and relying on diffusion to transport polarized atoms allows a magnetometer to be operated with minimal sensitivity to the AC-Stark field.

arXiv:1212.5624•Optics Letters•Mar 13, 2013•55 citations

Ultrasensitive Optical Rotation Detection With Closed-Loop Suppression of Spin Polarization Error

Xing Heng, Kai Wei, Tian Zhao +6 more

Optical rotation detection system (ORDS) utilizing quantum nondemolition (QND) measurement methods is widely applied in the field of quantum metrology and quantum information. However, the sensitivity of ORDS is limited by the uncertainty from optical-couple noise during the measurement of the atomic spin ensemble. In this study, we specifically analyze the mechanism of optical-couple noise caused by the fluctuations of probe light’s polarization in the modulated ORDS with a new model established to describe atomic spin precession in this particular condition. It is discovered that transverse electron-spin polarization errors are generated by the residual probe photon spin polarization in the ORDS, which results in extra coupling magnetic noise. In order to suppress this noise, a novel in situ method is proposed that the resultant electron-spin errors are reduced by a specifically designed closed-loop system. The results are verified through the ORDS in a co-magnetometer. After zeroing the extra probe photon spin polarization, an angular sensitivity better than$1 \times 10 ^{\mathrm {-8}}$rad/Hz$^{\mathrm {1/2}}$is achieved for frequencies higher than 5 Hz, demonstrating a probe background noise of 0.26 fT/Hz$^{\mathrm {1/2}}$@14.5 Hz, approaching electronic noise and photon shot noise (PSN). With closed-loop control, the optical rotation bias instability is promoted by 4.2 times (from 107.9 to$25.7 \mu $rad/h), and the angular noise of the ORDS is reduced by 2.4 times at 1–100 Hz. The measurement uncertainty of the realized ORDS nears the standard quantum limit, paving the road for long-term ultrasensitive measurements for new physics explorations.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2023•19 citations

Squeezing of atomic quantum projection noise

Patrick Windpassinger, Daniel Oblak, Ulrich B. Hoff +4 more

We provide a framework for understanding recent experiments on squeezing of a collective atomic pseudo-spin, induced by a homodyne measurement on off-resonant probe light interrogating the atoms. The detection of light decimates the atomic state distribution and we discuss the conditions under which the resulting reduced quantum fluctuations are metrologically relevant. In particular, we consider a dual probe scheme which benefits from a cancelation of classical common mode noise sources such that quantum fluctuations from light and atoms are the main contributions to the detected signal.

arXiv:0906.2572•Journal of Modern Optics•Jun 26, 2009•8 citations
In a recent letter [Auzinsh {\it{et. al.}} (physics/0403097)] we have analyzed the noise properties of an idealized atomic magnetometer that utilizes spin squeezing induced by a continuous quantum nondemolition measurement. Such a magnetometer measures spin precession of NNN atomic spins by detecting optical rotation of far-detuned probe light. Here we consider maximally squeezed probe light, and carry out a detailed derivation of the contribution to the noise in a magnetometric measurement due to the differential AC Stark shift between Zeeman sublevels arising from quantum fluctuations of the probe polarization.
We consider the limitations due to noise (e.g., quantum projection noise and photon shot-noise) on the sensitivity of an idealized atomic magnetometer that utilizes spin squeezing induced by a continuous quantum nondemolition measurement. Such a magnetometer measures spin precession of NNN atomic spins by detecting optical rotation of far-detuned light. We show that for very short measurement times, the optimal sensitivity scales as ${N}^{\ensuremath{-}3/4}$; if strongly squeezed probe light is used, the Heisenberg limit of ${N}^{\ensuremath{-}1}$ scaling can be achieved. However, if the measurement time exceeds ${\ensuremath{\tau}}_{\mathrm{r}\mathrm{e}\mathrm{l}}/{N}^{1/2}$ in the former case, or ${\ensuremath{\tau}}_{\mathrm{r}\mathrm{e}\mathrm{l}}/N$ in the latter, where ${\ensuremath{\tau}}_{\mathrm{r}\mathrm{e}\mathrm{l}}$ is the spin relaxation time, the scaling becomes ${N}^{\ensuremath{-}1/2}$, as for a standard shot-noise-limited magnetometer.
We investigate theoretically and experimentally a nondestructive interferometric measurement of the state population of an ensemble of laser-cooled and trapped atoms. This study is a step toward generation of (pseudo)spin squeezing of cold atoms targeted at the improvement of the cesium clock performance beyond the limit set by the quantum projection noise of atoms. We calculate the phase shift and the quantum noise of a near-resonant optical probe pulse propagating through a cloud of cold 133Cs^{133}\mathrm{Cs}133Cs atoms. We analyze the figure of merit for a quantum nondemolition (QND) measurement of the collective pseudospin and show that it can be expressed simply as a product of the ensemble optical density and the pulse-integrated rate of the spontaneous emission caused by the off-resonant probe light. Based on this, we propose a protocol for the sequence of operations required to generate and utilize spin squeezing for the improved atomic clock performance via a QND measurement on the probe light. In the experimental part we demonstrate that the interferometric measurement of the atomic population can reach a sensitivity of the order of Nat\sqrt{{N}_{\mathrm{at}}}Nat​​ in a cloud of Nat{N}_{\mathrm{at}}Nat​ cold atoms, which is an important benchmark toward the experimental realization of the theoretically analyzed protocol.
We analyze systematic (classical) and fundamental (quantum) limitations of the sensitivity of optical magnetometers resulting from ac Stark shifts. We show that in contrast to absorption-based techniques, the signal reduction associated with classical broadening can be compensated in magnetometers based on phase measurements using electromagnetically induced transparency (EIT). However due to ac Stark--associated quantum noise the signal-to-noise ratio of EIT-based magnetometers attains a maximum value at a certain laser intensity. This value is independent on the quantum statistics of the light and defines a standard quantum limit of sensitivity. We demonstrate that an EIT-based optical magnetometer in Faraday configuration is the best candidate to achieve the highest sensitivity of magnetic-field detection and give a detailed analysis of such a device.
Optical rotation detection system (ORDS) utilizing quantum nondemolition (QND) measurement methods is widely applied in the field of quantum metrology and quantum information. However, the sensitivity of ORDS is limited by the uncertainty from optical-couple noise during the measurement of the atomic spin ensemble. In this study, we specifically analyze the mechanism of optical-couple noise caused by the fluctuations of probe light’s polarization in the modulated ORDS with a new model established to describe atomic spin precession in this particular condition. It is discovered that transverse electron-spin polarization errors are generated by the residual probe photon spin polarization in the ORDS, which results in extra coupling magnetic noise. In order to suppress this noise, a novel in situ method is proposed that the resultant electron-spin errors are reduced by a specifically designed closed-loop system. The results are verified through the ORDS in a co-magnetometer. After zeroing the extra probe photon spin polarization, an angular sensitivity better than1×10−81 \times 10 ^{\mathrm {-8}}1×10−8rad/Hz1/2^{\mathrm {1/2}}1/2is achieved for frequencies higher than 5 Hz, demonstrating a probe background noise of 0.26 fT/Hz1/2^{\mathrm {1/2}}1/2@14.5 Hz, approaching electronic noise and photon shot noise (PSN). With closed-loop control, the optical rotation bias instability is promoted by 4.2 times (from 107.9 to$25.7 \mu $rad/h), and the angular noise of the ORDS is reduced by 2.4 times at 1–100 Hz. The measurement uncertainty of the realized ORDS nears the standard quantum limit, paving the road for long-term ultrasensitive measurements for new physics explorations.
We provide a framework for understanding recent experiments on squeezing of a collective atomic pseudo-spin, induced by a homodyne measurement on off-resonant probe light interrogating the atoms. The detection of light decimates the atomic state distribution and we discuss the conditions under which the resulting reduced quantum fluctuations are metrologically relevant. In particular, we consider a dual probe scheme which benefits from a cancelation of classical common mode noise sources such that quantum fluctuations from light and atoms are the main contributions to the detected signal.