arXiv:1212.5624 · Optics Letters

Diffusive suppression of AC-Stark shifts in atomic magnetometers

Ibrahim Sulai, R. Wyllie, Matt Kauer, G. S. Smetana, Ronald T. Wakai, T. G. Walker

Published Mar 13, 2013• 55 citations
arXivHTMLPDF

Abstract

In atomic magnetometers, the vector AC-Stark shift associated with circularly polarized light generates spatially varying effective magnetic fields, which limit the magnetometer response and serve as sources of noise. We describe a scheme whereby optically pumping a small subvolume of the magnetometer cell and relying on diffusion to transport polarized atoms allows a magnetometer to be operated with minimal sensitivity to the AC-Stark field.

DOI
10.1364/ol.38.000974

Related papers

Suppression Method of AC-Stark Shift in SERF Atomic Magnetometer

Yang Li, Ming Ding, Xuejing Liu +3 more

In a spin-exchange-relaxation-free (SERF) atomic magnetometer with ultrahigh sensitivity, the ac-Stark shift generated by circularly polarized light results in the attenuation of the SERF atomic magnetometer response, and the virtual magnetic field gradient induced by the ac-Stark shift can reduce the sensitivity of the SERF atomic magnetometer. In this paper, we use a hybrid optical pumping method to address the ac-Stark shift problem. By switching between left-hand and right-hand circularly polarized lights and compensating the residual magnetic field of the magnetometer, the ac-Stark shift could be reduced and then suppressed effectively.

IEEE photonics journal•Sep 27, 2018•22 citations

All-Optical Vector Atomic Magnetometer

Brian Patton, E. Zhivun, D. C. Hovde +1 more

We demonstrate an all-optical magnetometer capable of measuring the magnitude and direction of a magnetic field using nonlinear magneto-optical rotation in cesium vapor. Vector capability is added by effective modulation of the field along orthogonal axes and subsequent demodulation of the magnetic-resonance frequency. This modulation is provided by the ac Stark shift induced by circularly polarized laser beams. The sensor exhibits a demonstrated rms noise floor of $\ensuremath{\sim}65\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}$ in measurement of the field magnitude and $0.5\text{ }\text{ }\mathrm{mrad}/\sqrt{\mathrm{Hz}}$ in the field direction; elimination of technical noise would improve these sensitivities to $12\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}$ and $10\text{ }\text{ }\ensuremath{\mu}\mathrm{rad}/\sqrt{\mathrm{Hz}}$, respectively. Applications for this all-optical vector magnetometer would include magnetically sensitive fundamental physics experiments, such as the search for a permanent electric dipole moment of the neutron.

arXiv:1403.7545•Physical Review Letters•Jul 1, 2014•190 citations

Suppressing virtual magnetic field noise and enhancing spin coherence in hybrid optical pumping atomic magnetometers

Faming Wang, Xiujie Fang, Yueyang Zhai +5 more

A hybrid optical pumping method employing a broad linewidth laser is proposed to enhance spin coherence and suppress virtual magnetic field noise in atomic magnetometers. The central frequency of broad linewidth laser is tuned to the resonance peak of the alkali-metal atoms D1 line. Its multiple frequency components suppress AC-Stark shift fluctuations caused by pumping laser frequency variations, thereby reducing virtual magnetic field noise. In addition, these components decrease the average optical absorption cross-section, improving the uniformity of atomic spin polarization, further enhancing spin coherence and extending transverse relaxation time. Experimental results show that, compared with narrow linewidth pumping, the proposed method suppresses virtual magnetic field noise by 17.95% to 34.50%, and increases the magnetometer response by 1.62% to 30.31% at 5 Hz. The average sensitivity within the frequency range of 1-20 Hz is improved to 0.158 fT/Hz 1/2 , representing a significant enhancement of 30.70% compared to narrow linewidth pumping.

EPJ Quantum Technology•Jun 2, 2026•0 citations

Light-shift suppression in an optically pumped magnetometer via dual-frequency optical pumping

Huanyu Zhou, J Q Li, Yi Zhang +5 more

The light shift represents a major source of measurement error and system noise in optically pumped atomic magnetometers (OPAMs). Tuning the laser frequency to a specific value is a common and effective approach to suppressing light shift in many optical-pumping systems. However, when this method is applied to OPAMs, a significant issue arises: at the zero-light-shift frequency, the magnetometer’s sensitivity decreases markedly. Consequently, it is not possible to optimize simultaneously both the measurement accuracy affected by the light shift and the overall sensitivity of the magnetometer. To address this contradiction, the underlying mechanism was analyzed using the theory of light absorption and the principles governing light–atom interactions, leading to the proposal of a dual-frequency optical-pumping scheme. Experimental results demonstrate that this approach can suppress the light shift by more than 95% while maintaining the optimal sensitivity of the OPAM. The proposed dual-frequency scheme can also be extended to other circularly polarized optical-pumping systems, thereby facilitating both the enhancement of OPAM performance and its practical deployment in real-world applications.

Advanced Photonics Nexus•Jun 19, 2026•0 citations

Quantum limit of optical magnetometry in the presence of ac Stark shifts

Michael Fleischhauer, Andrey B. Matsko, Marlan O. Scully

We analyze systematic (classical) and fundamental (quantum) limitations of the sensitivity of optical magnetometers resulting from ac Stark shifts. We show that in contrast to absorption-based techniques, the signal reduction associated with classical broadening can be compensated in magnetometers based on phase measurements using electromagnetically induced transparency (EIT). However due to ac Stark--associated quantum noise the signal-to-noise ratio of EIT-based magnetometers attains a maximum value at a certain laser intensity. This value is independent on the quantum statistics of the light and defines a standard quantum limit of sensitivity. We demonstrate that an EIT-based optical magnetometer in Faraday configuration is the best candidate to achieve the highest sensitivity of magnetic-field detection and give a detailed analysis of such a device.

arXiv:quant-ph/0001072•Physical Review A•Jun 14, 2000•129 citations

Measurement and cancellation of light shift in optically pumped magnetometers

Rujie Li, Wei Quan, Wenfeng Fan +1 more

Light shift arising from the circularly polarized pump beam in atomic magnetometers can induce an undesired magnetic response, and thus affect their accuracy. Here, the light shift and the corresponding cross-talk effect in the magnetometer have been investigated, and a scheme with an additional off-resonant pump beam with an appropriate polarization and intensity has been proposed to effectively reject the light shift. And the experimental results reproduce the expected behavior. This scheme provides a powerful tool to reject the light shift in optical pumping systems, in particular, the hybrid optically pumped systems.

Europhysics Letters (EPL)•Mar 1, 2018•13 citations
In atomic magnetometers, the vector AC-Stark shift associated with circularly polarized light generates spatially varying effective magnetic fields, which limit the magnetometer response and serve as sources of noise. We describe a scheme whereby optically pumping a small subvolume of the magnetometer cell and relying on diffusion to transport polarized atoms allows a magnetometer to be operated with minimal sensitivity to the AC-Stark field.
In a spin-exchange-relaxation-free (SERF) atomic magnetometer with ultrahigh sensitivity, the ac-Stark shift generated by circularly polarized light results in the attenuation of the SERF atomic magnetometer response, and the virtual magnetic field gradient induced by the ac-Stark shift can reduce the sensitivity of the SERF atomic magnetometer. In this paper, we use a hybrid optical pumping method to address the ac-Stark shift problem. By switching between left-hand and right-hand circularly polarized lights and compensating the residual magnetic field of the magnetometer, the ac-Stark shift could be reduced and then suppressed effectively.
We demonstrate an all-optical magnetometer capable of measuring the magnitude and direction of a magnetic field using nonlinear magneto-optical rotation in cesium vapor. Vector capability is added by effective modulation of the field along orthogonal axes and subsequent demodulation of the magnetic-resonance frequency. This modulation is provided by the ac Stark shift induced by circularly polarized laser beams. The sensor exhibits a demonstrated rms noise floor of $\ensuremath{\sim}65\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}$ in measurement of the field magnitude and 0.5  mrad/Hz0.5\text{ }\text{ }\mathrm{mrad}/\sqrt{\mathrm{Hz}}0.5  mrad/Hz​ in the field direction; elimination of technical noise would improve these sensitivities to 12  fT/Hz12\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}12  fT/Hz​ and $10\text{ }\text{ }\ensuremath{\mu}\mathrm{rad}/\sqrt{\mathrm{Hz}}$, respectively. Applications for this all-optical vector magnetometer would include magnetically sensitive fundamental physics experiments, such as the search for a permanent electric dipole moment of the neutron.
A hybrid optical pumping method employing a broad linewidth laser is proposed to enhance spin coherence and suppress virtual magnetic field noise in atomic magnetometers. The central frequency of broad linewidth laser is tuned to the resonance peak of the alkali-metal atoms D1 line. Its multiple frequency components suppress AC-Stark shift fluctuations caused by pumping laser frequency variations, thereby reducing virtual magnetic field noise. In addition, these components decrease the average optical absorption cross-section, improving the uniformity of atomic spin polarization, further enhancing spin coherence and extending transverse relaxation time. Experimental results show that, compared with narrow linewidth pumping, the proposed method suppresses virtual magnetic field noise by 17.95% to 34.50%, and increases the magnetometer response by 1.62% to 30.31% at 5 Hz. The average sensitivity within the frequency range of 1-20 Hz is improved to 0.158 fT/Hz 1/2 , representing a significant enhancement of 30.70% compared to narrow linewidth pumping.
The light shift represents a major source of measurement error and system noise in optically pumped atomic magnetometers (OPAMs). Tuning the laser frequency to a specific value is a common and effective approach to suppressing light shift in many optical-pumping systems. However, when this method is applied to OPAMs, a significant issue arises: at the zero-light-shift frequency, the magnetometer’s sensitivity decreases markedly. Consequently, it is not possible to optimize simultaneously both the measurement accuracy affected by the light shift and the overall sensitivity of the magnetometer. To address this contradiction, the underlying mechanism was analyzed using the theory of light absorption and the principles governing light–atom interactions, leading to the proposal of a dual-frequency optical-pumping scheme. Experimental results demonstrate that this approach can suppress the light shift by more than 95% while maintaining the optimal sensitivity of the OPAM. The proposed dual-frequency scheme can also be extended to other circularly polarized optical-pumping systems, thereby facilitating both the enhancement of OPAM performance and its practical deployment in real-world applications.
We analyze systematic (classical) and fundamental (quantum) limitations of the sensitivity of optical magnetometers resulting from ac Stark shifts. We show that in contrast to absorption-based techniques, the signal reduction associated with classical broadening can be compensated in magnetometers based on phase measurements using electromagnetically induced transparency (EIT). However due to ac Stark--associated quantum noise the signal-to-noise ratio of EIT-based magnetometers attains a maximum value at a certain laser intensity. This value is independent on the quantum statistics of the light and defines a standard quantum limit of sensitivity. We demonstrate that an EIT-based optical magnetometer in Faraday configuration is the best candidate to achieve the highest sensitivity of magnetic-field detection and give a detailed analysis of such a device.
Light shift arising from the circularly polarized pump beam in atomic magnetometers can induce an undesired magnetic response, and thus affect their accuracy. Here, the light shift and the corresponding cross-talk effect in the magnetometer have been investigated, and a scheme with an additional off-resonant pump beam with an appropriate polarization and intensity has been proposed to effectively reject the light shift. And the experimental results reproduce the expected behavior. This scheme provides a powerful tool to reject the light shift in optical pumping systems, in particular, the hybrid optically pumped systems.