Speed meter as a quantum nondemolition measuring device for force

Farid Ya Khalili, Yu. Levin

Published Oct 15, 1996• 20 citations
arXivHTMLPDF

Abstract

Braginsky has proposed a speed meter (a speed or momentum measuring device), consisting of a small Fabry-Perot cavity rigidly attached to a freely moving test mass. This work devises an optical readout strategy which enables the meter, when monitoring a classical force via speed changes, to beat the standard quantum limit---at least in principle.

DOI
10.1103/physrevd.54.4735

Related papers

Analysis of a quantum nondemolition speed-meter interferometer

Patricia Purdue

In the quest to develop viable designs for third-generation optical interferometric gravitational-wave detectors (e.g. LIGO-III and EURO), one strategy is to monitor the relative momentum or speed of the test-mass mirrors rather than monitoring their relative position. This paper describes and analyzes the most straightforward design for a speed meter interferometer that accomplishes this---a design (due to Braginsky, Gorodetsky, Khalili and Thorne) that is analogous to a microwave-cavity speed meter conceived by Braginsky and Khalili. A mathematical mapping between the microwave speed meter and the optical interferometric speed meter is developed and is used to show [in accord with the speed being a quantum nondemolition observable] that in principle the interferometric speed meter can beat the gravitational-wave standard quantum limit (SQL) by an arbitrarily large amount, over an arbitrarily wide range of frequencies, and can do so without the use of squeezed vacuum or any auxiliary filter cavities at the interferometer's input or output. However, in practice, to reach or beat the SQL, this specific speed meter requires exorbitantly high input light power. The physical reason for this is explored, along with other issues such as constraints on performance due to optical dissipation. This analysis forms a foundation for ongoing attempts to develop a more practical variant of an interferometric speed meter and to combine the speed meter concept with other ideas to yield a promising LIGO-III/EURO interferometer design that entails low laser power.

arXiv:gr-qc/0111042•Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields•Jun 25, 2002•57 citations

Quantum speed meter based on dissipative coupling

Sergey P. Vyatchanin, Andrey B. Matsko

We consider dissipative coupling Fabry-Perot cavity, i.e. its input mirror transmittance depends on position of probe mass. We show that dissipative coupling provide possibility to realize quantum speed meter by natural way, without additional setup for subtraction of position x(t) and delayed position x(t-τ). Quantum speed meter is a quantum non demolition (QND) meter which allow to overcome Standatd Quantum Limit — we show it for speed meter based on dissipative coupling.

Journal of Physics Conference Series•Jan 1, 2017•1 citation

Practical speed meter designs for quantum nondemolition gravitational-wave interferometers

Patricia Purdue, Yanbei Chen

In the quest to develop viable designs for third-generation optical interferometric gravitational-wave detectors (e.g., LIGO-III and EURO), one strategy is to monitor the relative momentum or speed of the test-mass mirrors, rather than monitoring their relative position. A previous paper analyzed a straightforward but impractical design for a speed-meter interferometer that accomplishes this. This paper describes some practical variants of speed-meter interferometers. Like the original interferometric speed meter, these designs in principle can beat the gravitational-wave standard quantum limit (SQL) by an arbitrarily large amount, over an arbitrarily wide range of frequencies. These variants essentially consist of a Michelson interferometer plus an extra ``sloshing'' cavity that sends the signal back into the interferometer with opposite phase shift, thereby cancelling the position information and leaving a net phase shift proportional to the relative velocity. In practice, the sensitivity of these variants will be limited by the maximum light power ${W}_{\mathrm{circ}}$ circulating in the arm cavities that the mirrors can support and by the leakage of vacuum into the optical train at dissipation points. In the absence of dissipation and with squeezed vacuum (power squeeze factor ${e}^{\ensuremath{-}2R}\ensuremath{\simeq}0.1)$ inserted into the output port so as to keep the circulating power down, the SQL can be beat by ${h/h}_{\mathrm{SQL}}\ensuremath{\sim}\sqrt{{W}_{\mathrm{circ}}^{\mathrm{SQL}}{e}^{\ensuremath{-}2R}{/W}_{\mathrm{circ}}}$ at all frequencies below some chosen ${f}_{\mathrm{opt}}\ensuremath{\simeq}100\mathrm{Hz}.$ Here ${W}_{\mathrm{circ}}^{\mathrm{SQL}}\ensuremath{\simeq}800\mathrm{kW}{(f}_{\mathrm{opt}}/100\mathrm{}\mathrm{Hz}{)}^{3}$ is the power required to reach the SQL in the absence of squeezing. (However, as the power increases in this expression, the speed meter becomes more narrow band; additional power and reoptimization of some parameters are required to maintain the wide band. See Sec. III B.) Estimates are given of the amount by which vacuum leakage at dissipation points will debilitate this sensitivity (see Fig. 12); these losses are 10% or less over most of the frequency range of interest $(f\ensuremath{\gtrsim}10\mathrm{Hz}).$ The sensitivity can be improved, particularly at high freqencies, by using frequency-dependent homodyne detection, which unfortunately requires two 4-km-long filter cavities (see Fig. 4).

arXiv:gr-qc/0208049•Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields•Dec 27, 2002•126 citations

Speedmeter scheme for gravitational-wave detectors based on EPR quantum entanglement

E. Knyazev, S. L. Danilishin, S. Hild +1 more

We propose a new implementation of a quantum speed meter QND measurement scheme. It employs two independent optical readouts of the interferometer test masses with different values of the bandwidths and of the optical circulating power, whose outputs have to be combined by an additional beamsplitter. Signals at the two outputs of the beamsplitter are proportional to the position and the velocity of the test masses, respectively. The influence of the position meter-like back action force associated with the position signal can be cancelled using the EPR approach by measuring the amplitude quadrature of the beamsplitter common output. • This is an article for the Special Issue in memory of V.B. Braginsky. • We propose a novel and arguably the simplest scheme of a speed meter interferometer. • Speed meters curb quantum noise at low frequencies, boosting the SNR for GW sources. • Combination of readouts of two detectors with distinct bandwidths yields speed signal. • No significant changes of the current GWD infrastructure is necessary for our scheme.

arXiv:1701.01694•Physics Letters A•Oct 18, 2017•21 citations

Quantum Measurement

Giacomo Mauro D’Ariano

In recent years advances in technology, especially in the field of quantum optics, have made possible repetitive quantum measurements on a single quantum object, an issue that remained an academic curiosity until 25 years ago. This book, first published in 1992, provides a tutorial introduction to this field. The book is coauthored by an experimentalist and a theorist: the former - Braginsky - was the first experimentalist after Weber to develop techniques for gravitational-wave detection; the latter - Khalili - contributed with Braginsky to develop the formal apparatus to describe the experimental devices for measurement schemes. After the first part, intended as a pedagogical appendix of a standard textbook, and devoted to the modern approach to quantum measurement, the second part is a review of some new methods of quantum measurements for macroscopic objects. The central problem is the detection of a small time-dependent classical force that acts on a quantum probe. This is the typical situation that occurs in gravitational-wave detection, where the probe is a macroscopic moving mass weakly coupled to a classical wave. The problem of gravitational-wave detection and the limitation to accuracy of measurement of position of a moving mass - the so-called standard quantum limit (SQL), which is a consequence of the random back-action of the measuring device on the mass - triggered the development of new quantum nondemolition (QND) measurements, i.e. measurements where the measured quantity is left unperturbed after the measurement. SQL and QND measurements (both Braginsky inventions) permeate the whole book as a transversal chapter. The aim is to give simple criteria and recipes to design a measuring device in order to optimize the accuracy of the measurement, and, at the same time, to minimize the perturbation that the device exerts on the measured object, so that it will not interfere with successive measurements on the same object. The continuous measurements are regarded as the limiting case of a sequence of repeated discrete measurements, when the interval between the measurements is much smaller than the characteristic time-scale on which the measured quantity changes. The analysis of continuous measurements give to the authors the opportunity to illustrate the watchdog effect and the quantum Zeno paradox (real effect), while deriving the master equation for the evolution of the object state. Then, an entire chapter is devoted to the analysis of devices for continuous measurement of small mechanical displacements. The book is easy to understand, and can serve as a complementary reading for graduate level courses in quantum mechanics. The material of the book can be useful for all scientists and engineers involved in researches related to high-sensitive quantum measurements, quantum information theory and quantum computation. The reader, however, should be aware that this book presents a very particular point of view, with no room left to very relevant concepts in quantum measurement theory, as, for example, squeezing, quantum amplification, joint-measurements of non-commuting observables and phase-measurements. More regrettably, the list of references is unsatisfactorily incomplete, with no mention of alternative developments, for example, regarding the SQL for measuring the position of a free mass. Here, schemes to breach the SQL have been proposed in the literature (Yuen H P 1983 Phys. Rev. Lett. 51 719, Ozawa M 1988 Phys. Rev. Lett. 60 385), whereas from the book one could conclude that such SQL would be unsurpassable. Also, a criticism is in order of the way of deriving some SQL's, based solely on the Heisenberg relation, even in consideration that the aim of such derivations is mostly pedagogical.

Measurement Science and Technology•Jul 1, 1997•0 citations

On the measurement of a weak classical force coupled to a quantum-mechanical oscillator. I. Issues of principle

Carlton M. Caves, Kip S. Thorne, Ronald W. P. Drever +2 more

The monitoring of a quantum-mechanical harmonic oscillator on which a classical force acts is important in a variety of high-precision experiments, such as the attempt to detect gravitational radiation. This paper reviews the standard techniques for monitoring the oscillator, and introduces a new technique which, in principle, can determine the details of the force with arbitrary accuracy, despite the quantum properties of the oscillator. The standard method for monitoring the oscillator is the "amplitude-and-phase" method (position or momentum transducer with output fed through a narrow-band amplifier). The accuracy obtainable by this method is limited by the uncertainty principle ("standard quantum limit"). To do better requires a measurement of the type which Braginsky has called "quantum nondemolition." A well known quantum nondemolition technique is "quantum counting," which can detect an arbitrarily weak classical force, but which cannot provide good accuracy in determining its precise time dependence. This paper considers extensively a new type of quantum nondemolition measurement---a "back-action-evading" measurement of the real part ${X}_{1}$ (or the imaginary part ${X}_{2}$) of the oscillator's complex amplitude. In principle ${X}_{1}$ can be measured "arbitrarily quickly and arbitrarily accurately," and a sequence of such measurements can lead to an arbitrarily accurate monitoring of the classical force. The authors describe explicit Gedanken experiments which demonstrate that ${X}_{1}$ can be measured arbitrarily quickly and arbitrarily accurately. In these experiments the measuring apparatus must be coupled to both the position (position transducer) and the momentum (momentum transducer) of the oscillator, and both couplings must be modulated sinusoidally. For a given measurement time the strength of the coupling determines the accuracy of the measurement; for arbitrarily strong coupling the measurement can be arbitrarily accurate. The "momentum transducer" is constructed by combining a "velocity transducer" with a "negative capacitor" or "negative spring." The modulated couplings are provided by an external, classical generator, which can be realized as a harmonic oscillator excited in an arbitrarily energetic, coherent state. One can avoid the use of two transducers by making "stroboscopic measurements" of ${X}_{1}$, in which one measures position (or momentum) at half-cycle intervals. Alternatively, one can make "continuous single-transducer" measurements of ${X}_{1}$ by modulating appropriately the output of a single transducer (position or momentum), and then filtering the output to pick out the information about ${X}_{1}$ and reject information about ${X}_{2}$. Continuous single-transducer measurements are useful in the case of weak coupling. In this case long measurement times are required to achieve good accuracy, and continuous single-transducer measurements are almost as good as perfectly coupled two-transducer measurements. Finally, the authors develop a theory of quantum nondemolition measurement for arbitrary systems. This paper (Paper I) concentrates on issues of principle; a sequel (Paper II) will consider issues of practice.

Reviews of Modern Physics•Apr 1, 1980•1,246 citations
Braginsky has proposed a speed meter (a speed or momentum measuring device), consisting of a small Fabry-Perot cavity rigidly attached to a freely moving test mass. This work devises an optical readout strategy which enables the meter, when monitoring a classical force via speed changes, to beat the standard quantum limit---at least in principle.
In the quest to develop viable designs for third-generation optical interferometric gravitational-wave detectors (e.g. LIGO-III and EURO), one strategy is to monitor the relative momentum or speed of the test-mass mirrors rather than monitoring their relative position. This paper describes and analyzes the most straightforward design for a speed meter interferometer that accomplishes this---a design (due to Braginsky, Gorodetsky, Khalili and Thorne) that is analogous to a microwave-cavity speed meter conceived by Braginsky and Khalili. A mathematical mapping between the microwave speed meter and the optical interferometric speed meter is developed and is used to show [in accord with the speed being a quantum nondemolition observable] that in principle the interferometric speed meter can beat the gravitational-wave standard quantum limit (SQL) by an arbitrarily large amount, over an arbitrarily wide range of frequencies, and can do so without the use of squeezed vacuum or any auxiliary filter cavities at the interferometer's input or output. However, in practice, to reach or beat the SQL, this specific speed meter requires exorbitantly high input light power. The physical reason for this is explored, along with other issues such as constraints on performance due to optical dissipation. This analysis forms a foundation for ongoing attempts to develop a more practical variant of an interferometric speed meter and to combine the speed meter concept with other ideas to yield a promising LIGO-III/EURO interferometer design that entails low laser power.
In the quest to develop viable designs for third-generation optical interferometric gravitational-wave detectors (e.g., LIGO-III and EURO), one strategy is to monitor the relative momentum or speed of the test-mass mirrors, rather than monitoring their relative position. A previous paper analyzed a straightforward but impractical design for a speed-meter interferometer that accomplishes this. This paper describes some practical variants of speed-meter interferometers. Like the original interferometric speed meter, these designs in principle can beat the gravitational-wave standard quantum limit (SQL) by an arbitrarily large amount, over an arbitrarily wide range of frequencies. These variants essentially consist of a Michelson interferometer plus an extra ``sloshing'' cavity that sends the signal back into the interferometer with opposite phase shift, thereby cancelling the position information and leaving a net phase shift proportional to the relative velocity. In practice, the sensitivity of these variants will be limited by the maximum light power Wcirc{W}_{\mathrm{circ}}Wcirc​ circulating in the arm cavities that the mirrors can support and by the leakage of vacuum into the optical train at dissipation points. In the absence of dissipation and with squeezed vacuum (power squeeze factor ${e}^{\ensuremath{-}2R}\ensuremath{\simeq}0.1)$ inserted into the output port so as to keep the circulating power down, the SQL can be beat by ${h/h}_{\mathrm{SQL}}\ensuremath{\sim}\sqrt{{W}_{\mathrm{circ}}^{\mathrm{SQL}}{e}^{\ensuremath{-}2R}{/W}_{\mathrm{circ}}}$ at all frequencies below some chosen ${f}_{\mathrm{opt}}\ensuremath{\simeq}100\mathrm{Hz}.$ Here ${W}_{\mathrm{circ}}^{\mathrm{SQL}}\ensuremath{\simeq}800\mathrm{kW}{(f}_{\mathrm{opt}}/100\mathrm{}\mathrm{Hz}{)}^{3}$ is the power required to reach the SQL in the absence of squeezing. (However, as the power increases in this expression, the speed meter becomes more narrow band; additional power and reoptimization of some parameters are required to maintain the wide band. See Sec. III B.) Estimates are given of the amount by which vacuum leakage at dissipation points will debilitate this sensitivity (see Fig. 12); these losses are 10% or less over most of the frequency range of interest $(f\ensuremath{\gtrsim}10\mathrm{Hz}).$ The sensitivity can be improved, particularly at high freqencies, by using frequency-dependent homodyne detection, which unfortunately requires two 4-km-long filter cavities (see Fig. 4).
We propose a new implementation of a quantum speed meter QND measurement scheme. It employs two independent optical readouts of the interferometer test masses with different values of the bandwidths and of the optical circulating power, whose outputs have to be combined by an additional beamsplitter. Signals at the two outputs of the beamsplitter are proportional to the position and the velocity of the test masses, respectively. The influence of the position meter-like back action force associated with the position signal can be cancelled using the EPR approach by measuring the amplitude quadrature of the beamsplitter common output. • This is an article for the Special Issue in memory of V.B. Braginsky. • We propose a novel and arguably the simplest scheme of a speed meter interferometer. • Speed meters curb quantum noise at low frequencies, boosting the SNR for GW sources. • Combination of readouts of two detectors with distinct bandwidths yields speed signal. • No significant changes of the current GWD infrastructure is necessary for our scheme.
In recent years advances in technology, especially in the field of quantum optics, have made possible repetitive quantum measurements on a single quantum object, an issue that remained an academic curiosity until 25 years ago. This book, first published in 1992, provides a tutorial introduction to this field. The book is coauthored by an experimentalist and a theorist: the former - Braginsky - was the first experimentalist after Weber to develop techniques for gravitational-wave detection; the latter - Khalili - contributed with Braginsky to develop the formal apparatus to describe the experimental devices for measurement schemes. After the first part, intended as a pedagogical appendix of a standard textbook, and devoted to the modern approach to quantum measurement, the second part is a review of some new methods of quantum measurements for macroscopic objects. The central problem is the detection of a small time-dependent classical force that acts on a quantum probe. This is the typical situation that occurs in gravitational-wave detection, where the probe is a macroscopic moving mass weakly coupled to a classical wave. The problem of gravitational-wave detection and the limitation to accuracy of measurement of position of a moving mass - the so-called standard quantum limit (SQL), which is a consequence of the random back-action of the measuring device on the mass - triggered the development of new quantum nondemolition (QND) measurements, i.e. measurements where the measured quantity is left unperturbed after the measurement. SQL and QND measurements (both Braginsky inventions) permeate the whole book as a transversal chapter. The aim is to give simple criteria and recipes to design a measuring device in order to optimize the accuracy of the measurement, and, at the same time, to minimize the perturbation that the device exerts on the measured object, so that it will not interfere with successive measurements on the same object. The continuous measurements are regarded as the limiting case of a sequence of repeated discrete measurements, when the interval between the measurements is much smaller than the characteristic time-scale on which the measured quantity changes. The analysis of continuous measurements give to the authors the opportunity to illustrate the watchdog effect and the quantum Zeno paradox (real effect), while deriving the master equation for the evolution of the object state. Then, an entire chapter is devoted to the analysis of devices for continuous measurement of small mechanical displacements. The book is easy to understand, and can serve as a complementary reading for graduate level courses in quantum mechanics. The material of the book can be useful for all scientists and engineers involved in researches related to high-sensitive quantum measurements, quantum information theory and quantum computation. The reader, however, should be aware that this book presents a very particular point of view, with no room left to very relevant concepts in quantum measurement theory, as, for example, squeezing, quantum amplification, joint-measurements of non-commuting observables and phase-measurements. More regrettably, the list of references is unsatisfactorily incomplete, with no mention of alternative developments, for example, regarding the SQL for measuring the position of a free mass. Here, schemes to breach the SQL have been proposed in the literature (Yuen H P 1983 Phys. Rev. Lett. 51 719, Ozawa M 1988 Phys. Rev. Lett. 60 385), whereas from the book one could conclude that such SQL would be unsurpassable. Also, a criticism is in order of the way of deriving some SQL's, based solely on the Heisenberg relation, even in consideration that the aim of such derivations is mostly pedagogical.
The monitoring of a quantum-mechanical harmonic oscillator on which a classical force acts is important in a variety of high-precision experiments, such as the attempt to detect gravitational radiation. This paper reviews the standard techniques for monitoring the oscillator, and introduces a new technique which, in principle, can determine the details of the force with arbitrary accuracy, despite the quantum properties of the oscillator. The standard method for monitoring the oscillator is the "amplitude-and-phase" method (position or momentum transducer with output fed through a narrow-band amplifier). The accuracy obtainable by this method is limited by the uncertainty principle ("standard quantum limit"). To do better requires a measurement of the type which Braginsky has called "quantum nondemolition." A well known quantum nondemolition technique is "quantum counting," which can detect an arbitrarily weak classical force, but which cannot provide good accuracy in determining its precise time dependence. This paper considers extensively a new type of quantum nondemolition measurement---a "back-action-evading" measurement of the real part X1{X}_{1}X1​ (or the imaginary part X2{X}_{2}X2​) of the oscillator's complex amplitude. In principle X1{X}_{1}X1​ can be measured "arbitrarily quickly and arbitrarily accurately," and a sequence of such measurements can lead to an arbitrarily accurate monitoring of the classical force. The authors describe explicit Gedanken experiments which demonstrate that X1{X}_{1}X1​ can be measured arbitrarily quickly and arbitrarily accurately. In these experiments the measuring apparatus must be coupled to both the position (position transducer) and the momentum (momentum transducer) of the oscillator, and both couplings must be modulated sinusoidally. For a given measurement time the strength of the coupling determines the accuracy of the measurement; for arbitrarily strong coupling the measurement can be arbitrarily accurate. The "momentum transducer" is constructed by combining a "velocity transducer" with a "negative capacitor" or "negative spring." The modulated couplings are provided by an external, classical generator, which can be realized as a harmonic oscillator excited in an arbitrarily energetic, coherent state. One can avoid the use of two transducers by making "stroboscopic measurements" of X1{X}_{1}X1​, in which one measures position (or momentum) at half-cycle intervals. Alternatively, one can make "continuous single-transducer" measurements of X1{X}_{1}X1​ by modulating appropriately the output of a single transducer (position or momentum), and then filtering the output to pick out the information about X1{X}_{1}X1​ and reject information about X2{X}_{2}X2​. Continuous single-transducer measurements are useful in the case of weak coupling. In this case long measurement times are required to achieve good accuracy, and continuous single-transducer measurements are almost as good as perfectly coupled two-transducer measurements. Finally, the authors develop a theory of quantum nondemolition measurement for arbitrary systems. This paper (Paper I) concentrates on issues of principle; a sequel (Paper II) will consider issues of practice.