Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Physics Conference Series

Quantum speed meter based on dissipative coupling

Sergey P. Vyatchanin, Andrey B. Matsko

Published Jan 1, 2017• 1 citation
Publisher

Abstract

We consider dissipative coupling Fabry-Perot cavity, i.e. its input mirror transmittance depends on position of probe mass. We show that dissipative coupling provide possibility to realize quantum speed meter by natural way, without additional setup for subtraction of position x(t) and delayed position x(t-τ). Quantum speed meter is a quantum non demolition (QND) meter which allow to overcome Standatd Quantum Limit — we show it for speed meter based on dissipative coupling.

DOI
10.1088/1742-6596/793/1/012031

Related papers

Speed meter as a quantum nondemolition measuring device for force

Farid Ya Khalili, Yu. Levin

Braginsky has proposed a speed meter (a speed or momentum measuring device), consisting of a small Fabry-Perot cavity rigidly attached to a freely moving test mass. This work devises an optical readout strategy which enables the meter, when monitoring a classical force via speed changes, to beat the standard quantum limit---at least in principle.

arXiv:gr-qc/9603046•Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields•Oct 15, 1996•20 citations

Analysis of a quantum nondemolition speed-meter interferometer

Patricia Purdue

In the quest to develop viable designs for third-generation optical interferometric gravitational-wave detectors (e.g. LIGO-III and EURO), one strategy is to monitor the relative momentum or speed of the test-mass mirrors rather than monitoring their relative position. This paper describes and analyzes the most straightforward design for a speed meter interferometer that accomplishes this---a design (due to Braginsky, Gorodetsky, Khalili and Thorne) that is analogous to a microwave-cavity speed meter conceived by Braginsky and Khalili. A mathematical mapping between the microwave speed meter and the optical interferometric speed meter is developed and is used to show [in accord with the speed being a quantum nondemolition observable] that in principle the interferometric speed meter can beat the gravitational-wave standard quantum limit (SQL) by an arbitrarily large amount, over an arbitrarily wide range of frequencies, and can do so without the use of squeezed vacuum or any auxiliary filter cavities at the interferometer's input or output. However, in practice, to reach or beat the SQL, this specific speed meter requires exorbitantly high input light power. The physical reason for this is explored, along with other issues such as constraints on performance due to optical dissipation. This analysis forms a foundation for ongoing attempts to develop a more practical variant of an interferometric speed meter and to combine the speed meter concept with other ideas to yield a promising LIGO-III/EURO interferometer design that entails low laser power.

arXiv:gr-qc/0111042•Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields•Jun 25, 2002•57 citations

Practical speed meter designs for quantum nondemolition gravitational-wave interferometers

Patricia Purdue, Yanbei Chen

In the quest to develop viable designs for third-generation optical interferometric gravitational-wave detectors (e.g., LIGO-III and EURO), one strategy is to monitor the relative momentum or speed of the test-mass mirrors, rather than monitoring their relative position. A previous paper analyzed a straightforward but impractical design for a speed-meter interferometer that accomplishes this. This paper describes some practical variants of speed-meter interferometers. Like the original interferometric speed meter, these designs in principle can beat the gravitational-wave standard quantum limit (SQL) by an arbitrarily large amount, over an arbitrarily wide range of frequencies. These variants essentially consist of a Michelson interferometer plus an extra ``sloshing'' cavity that sends the signal back into the interferometer with opposite phase shift, thereby cancelling the position information and leaving a net phase shift proportional to the relative velocity. In practice, the sensitivity of these variants will be limited by the maximum light power ${W}_{\mathrm{circ}}$ circulating in the arm cavities that the mirrors can support and by the leakage of vacuum into the optical train at dissipation points. In the absence of dissipation and with squeezed vacuum (power squeeze factor ${e}^{\ensuremath{-}2R}\ensuremath{\simeq}0.1)$ inserted into the output port so as to keep the circulating power down, the SQL can be beat by ${h/h}_{\mathrm{SQL}}\ensuremath{\sim}\sqrt{{W}_{\mathrm{circ}}^{\mathrm{SQL}}{e}^{\ensuremath{-}2R}{/W}_{\mathrm{circ}}}$ at all frequencies below some chosen ${f}_{\mathrm{opt}}\ensuremath{\simeq}100\mathrm{Hz}.$ Here ${W}_{\mathrm{circ}}^{\mathrm{SQL}}\ensuremath{\simeq}800\mathrm{kW}{(f}_{\mathrm{opt}}/100\mathrm{}\mathrm{Hz}{)}^{3}$ is the power required to reach the SQL in the absence of squeezing. (However, as the power increases in this expression, the speed meter becomes more narrow band; additional power and reoptimization of some parameters are required to maintain the wide band. See Sec. III B.) Estimates are given of the amount by which vacuum leakage at dissipation points will debilitate this sensitivity (see Fig. 12); these losses are 10% or less over most of the frequency range of interest $(f\ensuremath{\gtrsim}10\mathrm{Hz}).$ The sensitivity can be improved, particularly at high freqencies, by using frequency-dependent homodyne detection, which unfortunately requires two 4-km-long filter cavities (see Fig. 4).

arXiv:gr-qc/0208049•Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields•Dec 27, 2002•126 citations

Shorcuts to adiabaticity with quantum non-demolition measurements.

Raphaël Menu, Giovanna Morigi

The realization of quantum adiabatic dynamics is at the core of implementations of adiabatic quantum computers. One major issue is to efficiently compromise between the long time scales required by the adiabatic protocol and the detrimental effects of the environment, which set an upper bound to the time scale of the operation. In this work we propose a protocol which achieves fast adiabatic dynamics by coupling the system to an external environment by the means of a quantum-non-demolition (QND) Hamiltonian. We analyse the infidelity of adiabatic transfer for a Landau-Zener problem in the presence of QND measurement, where the qubit couples to a meter which in turn quickly dissipates. We analyse the protocol's fidelity as a function of the strength of the QND coupling and of the relaxation time of the meter. In the limit where the decay rate of the ancilla is the largest frequency scale of the dynamics, the QND coupling induces an effective dephasing in the adiabatic basis. Optimal conditions for adiabaticity are found when the coupling with the meter induces dissipative dynamics which suppresses unwanted diabatic transitions.

•Jul 26, 2021•0 citations

Speedmeter scheme for gravitational-wave detectors based on EPR quantum entanglement

E. Knyazev, S. L. Danilishin, S. Hild +1 more

We propose a new implementation of a quantum speed meter QND measurement scheme. It employs two independent optical readouts of the interferometer test masses with different values of the bandwidths and of the optical circulating power, whose outputs have to be combined by an additional beamsplitter. Signals at the two outputs of the beamsplitter are proportional to the position and the velocity of the test masses, respectively. The influence of the position meter-like back action force associated with the position signal can be cancelled using the EPR approach by measuring the amplitude quadrature of the beamsplitter common output. • This is an article for the Special Issue in memory of V.B. Braginsky. • We propose a novel and arguably the simplest scheme of a speed meter interferometer. • Speed meters curb quantum noise at low frequencies, boosting the SNR for GW sources. • Combination of readouts of two detectors with distinct bandwidths yields speed signal. • No significant changes of the current GWD infrastructure is necessary for our scheme.

arXiv:1701.01694•Physics Letters A•Oct 18, 2017•21 citations

Teleportation-based speed meter for precision measurement

Yohei Nishino, James W. Gardner, Yanbei Chen +1 more

We propose a quantum teleportation-based speed meter for interferometric displacement sensing. The primary motivation is to transform a conventional position-sensing interferometer into a quantum non-demolition speed measurement device, without modifying its fundamental optical configuration. Two equivalent implementations are presented: an online approach that uses real-time displacement operation and an offline approach that relies on post-processing. Both implementations reduce quantum radiation pressure noise and surpass the standard quantum limit of measuring displacement, and they can be applied to a wide range of interferometer configurations. We discuss potential applications to gravitational-wave detectors, where our scheme enhances low-frequency sensitivity without requiring modifications to the core optics of a conventional Michelson interferometer (e.g., substrate or coating properties). This approach offers a new path to back-action evasion enabled by quantum entanglement.

arXiv:2504.18111•npj Quantum Information•Oct 22, 2025•7 citations
We consider dissipative coupling Fabry-Perot cavity, i.e. its input mirror transmittance depends on position of probe mass. We show that dissipative coupling provide possibility to realize quantum speed meter by natural way, without additional setup for subtraction of position x(t) and delayed position x(t-τ). Quantum speed meter is a quantum non demolition (QND) meter which allow to overcome Standatd Quantum Limit — we show it for speed meter based on dissipative coupling.
In the quest to develop viable designs for third-generation optical interferometric gravitational-wave detectors (e.g. LIGO-III and EURO), one strategy is to monitor the relative momentum or speed of the test-mass mirrors rather than monitoring their relative position. This paper describes and analyzes the most straightforward design for a speed meter interferometer that accomplishes this---a design (due to Braginsky, Gorodetsky, Khalili and Thorne) that is analogous to a microwave-cavity speed meter conceived by Braginsky and Khalili. A mathematical mapping between the microwave speed meter and the optical interferometric speed meter is developed and is used to show [in accord with the speed being a quantum nondemolition observable] that in principle the interferometric speed meter can beat the gravitational-wave standard quantum limit (SQL) by an arbitrarily large amount, over an arbitrarily wide range of frequencies, and can do so without the use of squeezed vacuum or any auxiliary filter cavities at the interferometer's input or output. However, in practice, to reach or beat the SQL, this specific speed meter requires exorbitantly high input light power. The physical reason for this is explored, along with other issues such as constraints on performance due to optical dissipation. This analysis forms a foundation for ongoing attempts to develop a more practical variant of an interferometric speed meter and to combine the speed meter concept with other ideas to yield a promising LIGO-III/EURO interferometer design that entails low laser power.
In the quest to develop viable designs for third-generation optical interferometric gravitational-wave detectors (e.g., LIGO-III and EURO), one strategy is to monitor the relative momentum or speed of the test-mass mirrors, rather than monitoring their relative position. A previous paper analyzed a straightforward but impractical design for a speed-meter interferometer that accomplishes this. This paper describes some practical variants of speed-meter interferometers. Like the original interferometric speed meter, these designs in principle can beat the gravitational-wave standard quantum limit (SQL) by an arbitrarily large amount, over an arbitrarily wide range of frequencies. These variants essentially consist of a Michelson interferometer plus an extra ``sloshing'' cavity that sends the signal back into the interferometer with opposite phase shift, thereby cancelling the position information and leaving a net phase shift proportional to the relative velocity. In practice, the sensitivity of these variants will be limited by the maximum light power Wcirc{W}_{\mathrm{circ}}Wcirc​ circulating in the arm cavities that the mirrors can support and by the leakage of vacuum into the optical train at dissipation points. In the absence of dissipation and with squeezed vacuum (power squeeze factor ${e}^{\ensuremath{-}2R}\ensuremath{\simeq}0.1)$ inserted into the output port so as to keep the circulating power down, the SQL can be beat by ${h/h}_{\mathrm{SQL}}\ensuremath{\sim}\sqrt{{W}_{\mathrm{circ}}^{\mathrm{SQL}}{e}^{\ensuremath{-}2R}{/W}_{\mathrm{circ}}}$ at all frequencies below some chosen ${f}_{\mathrm{opt}}\ensuremath{\simeq}100\mathrm{Hz}.$ Here ${W}_{\mathrm{circ}}^{\mathrm{SQL}}\ensuremath{\simeq}800\mathrm{kW}{(f}_{\mathrm{opt}}/100\mathrm{}\mathrm{Hz}{)}^{3}$ is the power required to reach the SQL in the absence of squeezing. (However, as the power increases in this expression, the speed meter becomes more narrow band; additional power and reoptimization of some parameters are required to maintain the wide band. See Sec. III B.) Estimates are given of the amount by which vacuum leakage at dissipation points will debilitate this sensitivity (see Fig. 12); these losses are 10% or less over most of the frequency range of interest $(f\ensuremath{\gtrsim}10\mathrm{Hz}).$ The sensitivity can be improved, particularly at high freqencies, by using frequency-dependent homodyne detection, which unfortunately requires two 4-km-long filter cavities (see Fig. 4).
The realization of quantum adiabatic dynamics is at the core of implementations of adiabatic quantum computers. One major issue is to efficiently compromise between the long time scales required by the adiabatic protocol and the detrimental effects of the environment, which set an upper bound to the time scale of the operation. In this work we propose a protocol which achieves fast adiabatic dynamics by coupling the system to an external environment by the means of a quantum-non-demolition (QND) Hamiltonian. We analyse the infidelity of adiabatic transfer for a Landau-Zener problem in the presence of QND measurement, where the qubit couples to a meter which in turn quickly dissipates. We analyse the protocol's fidelity as a function of the strength of the QND coupling and of the relaxation time of the meter. In the limit where the decay rate of the ancilla is the largest frequency scale of the dynamics, the QND coupling induces an effective dephasing in the adiabatic basis. Optimal conditions for adiabaticity are found when the coupling with the meter induces dissipative dynamics which suppresses unwanted diabatic transitions.
We propose a new implementation of a quantum speed meter QND measurement scheme. It employs two independent optical readouts of the interferometer test masses with different values of the bandwidths and of the optical circulating power, whose outputs have to be combined by an additional beamsplitter. Signals at the two outputs of the beamsplitter are proportional to the position and the velocity of the test masses, respectively. The influence of the position meter-like back action force associated with the position signal can be cancelled using the EPR approach by measuring the amplitude quadrature of the beamsplitter common output. • This is an article for the Special Issue in memory of V.B. Braginsky. • We propose a novel and arguably the simplest scheme of a speed meter interferometer. • Speed meters curb quantum noise at low frequencies, boosting the SNR for GW sources. • Combination of readouts of two detectors with distinct bandwidths yields speed signal. • No significant changes of the current GWD infrastructure is necessary for our scheme.
We propose a quantum teleportation-based speed meter for interferometric displacement sensing. The primary motivation is to transform a conventional position-sensing interferometer into a quantum non-demolition speed measurement device, without modifying its fundamental optical configuration. Two equivalent implementations are presented: an online approach that uses real-time displacement operation and an offline approach that relies on post-processing. Both implementations reduce quantum radiation pressure noise and surpass the standard quantum limit of measuring displacement, and they can be applied to a wide range of interferometer configurations. We discuss potential applications to gravitational-wave detectors, where our scheme enhances low-frequency sensitivity without requiring modifications to the core optics of a conventional Michelson interferometer (e.g., substrate or coating properties). This approach offers a new path to back-action evasion enabled by quantum entanglement.