arXiv:gr-qc/0508022 · Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields

Practical design of the optical lever intracavity topology of gravitational-wave detectors

S. L. Danilishin, F. Ya. Khalili

Published Jan 19, 2006• 19 citations
arXivHTMLPDF

Abstract

The quantum nondemolition (QND) intracavity topologies of gravitational-wave detectors proposed several years ago allow us, in principle, to obtain sensitivity significantly better than the standard quantum limit using relatively small amount of optical pumping power. In this article we consider an improved more practical version of the optical lever intracavity scheme. It differs from the original version by the symmetry which allows to suppress influence of the input light amplitude fluctuation. In addition, it provides the means to inject optical pumping inside the scheme without increase of optical losses. We consider also sensitivity limitations imposed by the local meter which is the key element of the intracavity topologies. Two variants of the local meter are analyzed, which are based on the spectral variation measurement and on the discrete sampling variation measurement, correspondingly. The former one, while can not be considered as a candidate for a practical implementation, allows, in principle, to obtain the best sensitivity and thus can be considered as an ideal ``asymptotic case'' for all other schemes. The DSVM-based local meter can be considered as a realistic scheme but its sensitivity, unfortunately, is by far not so good just due to a couple of peculiar numeric factors specific for this scheme. From our point of view search of new methods of mechanical QND measurements probably based on improved DSVM scheme or which combine the local meter with the pondermotive squeezing technique, is necessary.

DOI
10.1103/physrevd.73.022002

Related papers

Quantum variational measurement and the optical lever intracavity topology of gravitational-wave detectors

Farit Ya. Khalili

The intracavity topologies of laser gravitational-wave detectors proposed several years ago are the promising way to obtain sensitivity of these devices significantly better than the Standard Quantum Limit (SQL). In essence, the intracavity detector is a two-stage device where the end mirrors displacement created by the gravitational wave is transferred to the displacement of an additional local mirror by means of the optical rigidity. The local mirror positions have to be monitored by an additional local meter. It is evident that the local meter precision defines the sensitivity of the detector. To overcome the SQL, the quantum variational measurement can be used in the local meter. In this method a frequency-dependent correlation between the meter backaction noise and measurement noise is introduced, which allows us to eliminate the backaction noise component from the meter output signal. This correlation is created by means of an additional filter cavity. In this article the sensitivity limitations of this scheme imposed by the optical losses both in the local meter itself and in the filter cavity are estimated. It is shown that the main sensitivity limitation stems from the filter cavity losses. In order to overcome it, it is necessary to increase the filter cavity length. In a preliminary prototype experiment, an approximate 10 m long filter cavity can be used to obtain sensitivity approximately 2--3 times better than the SQL. For future Quantum Non-Demolition (QND) gravitational-wave detectors with sensitivity about 10 times better than the SQL, the filter cavity length should be within kilometer range.

arXiv:gr-qc/0607028•Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields•Apr 19, 2007•6 citations

Optical quantuma non-demolition meter for gravitational wave detection

S. L. Danilishin, Farid Ya Khalili

We propose new gravitational wave detector design and new method of measurement that is based on principle of quantum non-demolition (QND) measurement. New design implies the so called "intracavity" measurement of the optical field parameters inside the cavity of interferometer without disturbing light quantum state. It is shown that using a technique called discrete sampling variation measurement (DSVM) in a local meter it is possible to overcome the standard quantum limit by an arbitrary amount limited only by the amount of optical energy circulating in the cavity of local meter and optical losses in the local meter mirrors. This technique being implemented will also be a demonstration of QND measurement and therefore can be used to demonstrate the detector moveable mirrors quantum behaviour.

CAOL . International Conference on Advanced Optoelectronics and Lasers•Jan 5, 2006•0 citations

Intracavity squeezing for a Kerr quantum nondemolition measurement scheme

Dariya Salykina, Stepan N. Balybin, Farid Ya Khalili

In the work by Balybin et al. [Phys. Rev. A 108, 053708 (2023)], the scheme of quantum nondemolition measurement of optical quanta that uses a resonantly enhanced Kerr nonlinearity in the optical microresonator, presqueezing of the probe beam, and its parametric amplification before the detection was analyzed theoretically. It was shown that the main factor that limits the sensitivity of the considered scheme is the interplay of optical losses and the nonlinear self-phase modulation (SPM) effect. Here we show that using the intracavity squeezing of the probe beam in this scheme, it is possible to cancel out the SPM effect. In this case, the sensitivity will be limited only by the available power in the pump beam and by the input/output losses in the signal beam. Our estimates show that using the best optical microresonators currently available, the sensitivity for the intracavity photon number approaching the single-photon one can be achieved. Therefore, this scheme could be of interest for optical quantum information processing tasks.

arXiv:2409.10222•Physical Review A•Jan 23, 2025•2 citations

Advanced quantum techniques for future gravitational-wave detectors

S. L. Danilishin, Farid Ya. Khalili, Haixing Miao

Quantum fluctuation of light limits the sensitivity of advanced laser interferometric gravitational-wave detectors. It is one of the principal obstacles on the way towards the next-generation gravitational-wave observatories. The envisioned significant improvement of the detector sensitivity requires using quantum non-demolition measurement and back-action evasion techniques, which allow us to circumvent the sensitivity limit imposed by the Heisenberg uncertainty principle. In our previous review article (Danilishin and Khalili in Living Rev Relativ 15:5, 2012 ), we laid down the basic principles of quantum measurement theory and provided the framework for analysing the quantum noise of interferometers. The scope of this paper is to review novel techniques for quantum noise suppression proposed in the recent years and put them in the same framework. Our delineation of interferometry schemes and topologies is intended as an aid in the process of selecting the design for the next-generation gravitational-wave observatories.

arXiv:1903.05223•Living Reviews in Relativity•Apr 29, 2019•84 citations

Quantum nondemolition and higher order effects for a nonlinear meter in an interferometric gravitational wave antenna

Yu. Levin

A new optical topology and signal readout strategy for a laser interferometer gravitational wave detector were proposed recently by Braginsky and Khalili. Their method is based on using a nonlinear medium inside a microwave oscillator to detect the gravitational-wave-induced spatial shift of the interferometer's standing optical wave. This paper proposes a quantum nondemolition scheme that could be realistically used for such a readout device and discusses a ``fundamental'' sensitivity limit imposed by a higher order optical effect.

arXiv:gr-qc/9703005•Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields•Feb 15, 1998•1 citation

Practical speed meter designs for quantum nondemolition gravitational-wave interferometers

Patricia Purdue, Yanbei Chen

In the quest to develop viable designs for third-generation optical interferometric gravitational-wave detectors (e.g., LIGO-III and EURO), one strategy is to monitor the relative momentum or speed of the test-mass mirrors, rather than monitoring their relative position. A previous paper analyzed a straightforward but impractical design for a speed-meter interferometer that accomplishes this. This paper describes some practical variants of speed-meter interferometers. Like the original interferometric speed meter, these designs in principle can beat the gravitational-wave standard quantum limit (SQL) by an arbitrarily large amount, over an arbitrarily wide range of frequencies. These variants essentially consist of a Michelson interferometer plus an extra ``sloshing'' cavity that sends the signal back into the interferometer with opposite phase shift, thereby cancelling the position information and leaving a net phase shift proportional to the relative velocity. In practice, the sensitivity of these variants will be limited by the maximum light power ${W}_{\mathrm{circ}}$ circulating in the arm cavities that the mirrors can support and by the leakage of vacuum into the optical train at dissipation points. In the absence of dissipation and with squeezed vacuum (power squeeze factor ${e}^{\ensuremath{-}2R}\ensuremath{\simeq}0.1)$ inserted into the output port so as to keep the circulating power down, the SQL can be beat by ${h/h}_{\mathrm{SQL}}\ensuremath{\sim}\sqrt{{W}_{\mathrm{circ}}^{\mathrm{SQL}}{e}^{\ensuremath{-}2R}{/W}_{\mathrm{circ}}}$ at all frequencies below some chosen ${f}_{\mathrm{opt}}\ensuremath{\simeq}100\mathrm{Hz}.$ Here ${W}_{\mathrm{circ}}^{\mathrm{SQL}}\ensuremath{\simeq}800\mathrm{kW}{(f}_{\mathrm{opt}}/100\mathrm{}\mathrm{Hz}{)}^{3}$ is the power required to reach the SQL in the absence of squeezing. (However, as the power increases in this expression, the speed meter becomes more narrow band; additional power and reoptimization of some parameters are required to maintain the wide band. See Sec. III B.) Estimates are given of the amount by which vacuum leakage at dissipation points will debilitate this sensitivity (see Fig. 12); these losses are 10% or less over most of the frequency range of interest $(f\ensuremath{\gtrsim}10\mathrm{Hz}).$ The sensitivity can be improved, particularly at high freqencies, by using frequency-dependent homodyne detection, which unfortunately requires two 4-km-long filter cavities (see Fig. 4).

arXiv:gr-qc/0208049•Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields•Dec 27, 2002•126 citations
The quantum nondemolition (QND) intracavity topologies of gravitational-wave detectors proposed several years ago allow us, in principle, to obtain sensitivity significantly better than the standard quantum limit using relatively small amount of optical pumping power. In this article we consider an improved more practical version of the optical lever intracavity scheme. It differs from the original version by the symmetry which allows to suppress influence of the input light amplitude fluctuation. In addition, it provides the means to inject optical pumping inside the scheme without increase of optical losses. We consider also sensitivity limitations imposed by the local meter which is the key element of the intracavity topologies. Two variants of the local meter are analyzed, which are based on the spectral variation measurement and on the discrete sampling variation measurement, correspondingly. The former one, while can not be considered as a candidate for a practical implementation, allows, in principle, to obtain the best sensitivity and thus can be considered as an ideal ``asymptotic case'' for all other schemes. The DSVM-based local meter can be considered as a realistic scheme but its sensitivity, unfortunately, is by far not so good just due to a couple of peculiar numeric factors specific for this scheme. From our point of view search of new methods of mechanical QND measurements probably based on improved DSVM scheme or which combine the local meter with the pondermotive squeezing technique, is necessary.
The intracavity topologies of laser gravitational-wave detectors proposed several years ago are the promising way to obtain sensitivity of these devices significantly better than the Standard Quantum Limit (SQL). In essence, the intracavity detector is a two-stage device where the end mirrors displacement created by the gravitational wave is transferred to the displacement of an additional local mirror by means of the optical rigidity. The local mirror positions have to be monitored by an additional local meter. It is evident that the local meter precision defines the sensitivity of the detector. To overcome the SQL, the quantum variational measurement can be used in the local meter. In this method a frequency-dependent correlation between the meter backaction noise and measurement noise is introduced, which allows us to eliminate the backaction noise component from the meter output signal. This correlation is created by means of an additional filter cavity. In this article the sensitivity limitations of this scheme imposed by the optical losses both in the local meter itself and in the filter cavity are estimated. It is shown that the main sensitivity limitation stems from the filter cavity losses. In order to overcome it, it is necessary to increase the filter cavity length. In a preliminary prototype experiment, an approximate 10 m long filter cavity can be used to obtain sensitivity approximately 2--3 times better than the SQL. For future Quantum Non-Demolition (QND) gravitational-wave detectors with sensitivity about 10 times better than the SQL, the filter cavity length should be within kilometer range.
We propose new gravitational wave detector design and new method of measurement that is based on principle of quantum non-demolition (QND) measurement. New design implies the so called "intracavity" measurement of the optical field parameters inside the cavity of interferometer without disturbing light quantum state. It is shown that using a technique called discrete sampling variation measurement (DSVM) in a local meter it is possible to overcome the standard quantum limit by an arbitrary amount limited only by the amount of optical energy circulating in the cavity of local meter and optical losses in the local meter mirrors. This technique being implemented will also be a demonstration of QND measurement and therefore can be used to demonstrate the detector moveable mirrors quantum behaviour.
In the work by Balybin et al. [Phys. Rev. A 108, 053708 (2023)], the scheme of quantum nondemolition measurement of optical quanta that uses a resonantly enhanced Kerr nonlinearity in the optical microresonator, presqueezing of the probe beam, and its parametric amplification before the detection was analyzed theoretically. It was shown that the main factor that limits the sensitivity of the considered scheme is the interplay of optical losses and the nonlinear self-phase modulation (SPM) effect. Here we show that using the intracavity squeezing of the probe beam in this scheme, it is possible to cancel out the SPM effect. In this case, the sensitivity will be limited only by the available power in the pump beam and by the input/output losses in the signal beam. Our estimates show that using the best optical microresonators currently available, the sensitivity for the intracavity photon number approaching the single-photon one can be achieved. Therefore, this scheme could be of interest for optical quantum information processing tasks.
Quantum fluctuation of light limits the sensitivity of advanced laser interferometric gravitational-wave detectors. It is one of the principal obstacles on the way towards the next-generation gravitational-wave observatories. The envisioned significant improvement of the detector sensitivity requires using quantum non-demolition measurement and back-action evasion techniques, which allow us to circumvent the sensitivity limit imposed by the Heisenberg uncertainty principle. In our previous review article (Danilishin and Khalili in Living Rev Relativ 15:5, 2012 ), we laid down the basic principles of quantum measurement theory and provided the framework for analysing the quantum noise of interferometers. The scope of this paper is to review novel techniques for quantum noise suppression proposed in the recent years and put them in the same framework. Our delineation of interferometry schemes and topologies is intended as an aid in the process of selecting the design for the next-generation gravitational-wave observatories.
A new optical topology and signal readout strategy for a laser interferometer gravitational wave detector were proposed recently by Braginsky and Khalili. Their method is based on using a nonlinear medium inside a microwave oscillator to detect the gravitational-wave-induced spatial shift of the interferometer's standing optical wave. This paper proposes a quantum nondemolition scheme that could be realistically used for such a readout device and discusses a ``fundamental'' sensitivity limit imposed by a higher order optical effect.
In the quest to develop viable designs for third-generation optical interferometric gravitational-wave detectors (e.g., LIGO-III and EURO), one strategy is to monitor the relative momentum or speed of the test-mass mirrors, rather than monitoring their relative position. A previous paper analyzed a straightforward but impractical design for a speed-meter interferometer that accomplishes this. This paper describes some practical variants of speed-meter interferometers. Like the original interferometric speed meter, these designs in principle can beat the gravitational-wave standard quantum limit (SQL) by an arbitrarily large amount, over an arbitrarily wide range of frequencies. These variants essentially consist of a Michelson interferometer plus an extra ``sloshing'' cavity that sends the signal back into the interferometer with opposite phase shift, thereby cancelling the position information and leaving a net phase shift proportional to the relative velocity. In practice, the sensitivity of these variants will be limited by the maximum light power Wcirc{W}_{\mathrm{circ}}Wcirc​ circulating in the arm cavities that the mirrors can support and by the leakage of vacuum into the optical train at dissipation points. In the absence of dissipation and with squeezed vacuum (power squeeze factor ${e}^{\ensuremath{-}2R}\ensuremath{\simeq}0.1)$ inserted into the output port so as to keep the circulating power down, the SQL can be beat by ${h/h}_{\mathrm{SQL}}\ensuremath{\sim}\sqrt{{W}_{\mathrm{circ}}^{\mathrm{SQL}}{e}^{\ensuremath{-}2R}{/W}_{\mathrm{circ}}}$ at all frequencies below some chosen ${f}_{\mathrm{opt}}\ensuremath{\simeq}100\mathrm{Hz}.$ Here ${W}_{\mathrm{circ}}^{\mathrm{SQL}}\ensuremath{\simeq}800\mathrm{kW}{(f}_{\mathrm{opt}}/100\mathrm{}\mathrm{Hz}{)}^{3}$ is the power required to reach the SQL in the absence of squeezing. (However, as the power increases in this expression, the speed meter becomes more narrow band; additional power and reoptimization of some parameters are required to maintain the wide band. See Sec. III B.) Estimates are given of the amount by which vacuum leakage at dissipation points will debilitate this sensitivity (see Fig. 12); these losses are 10% or less over most of the frequency range of interest $(f\ensuremath{\gtrsim}10\mathrm{Hz}).$ The sensitivity can be improved, particularly at high freqencies, by using frequency-dependent homodyne detection, which unfortunately requires two 4-km-long filter cavities (see Fig. 4).