Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:cond-mat/0604018 · Review of Scientific Instruments

System for measuring auto- and cross correlation of current noise at low temperatures

L. DiCarlo, Y. Zhang, Douglas McClure, Charles M. Marcus, Loren N. Pfeiffer, K. W. West

Published Jul 1, 2006• 79 citations
arXivHTMLPDF

Abstract

We describe the construction and operation of a two-channel noise detection system for measuring power and cross spectral densities of current fluctuations near 2MHz in electronic devices at low temperatures. The system employs cryogenic amplification and fast Fourier transform based spectral measurement. The gain and electron temperature are calibrated using Johnson noise thermometry. Full shot noise of 100pA can be resolved with an integration time of 10s. We report a demonstration measurement of bias-dependent current noise in a gate defined GaAs∕AlGaAs quantum point contact.

DOI
10.1063/1.2221541

Related papers

Measurement for quantum shot noise in a quantum point contact at low temperatures

Masayuki Hashisaka, Y Yamauchi, Shuji Nakamura +3 more

We report an experimental development for the high-frequency shot noise measurement system in the 3 He- 4 He dilution refrigerator. The target frequency of the measurement was set to a few MHz with the cross correlation scheme adopted for high accuracy. The system was calibrated by measuring Johnson-Nyquist noise of the quantum point contact (QPC). We prove that our system has enough accuracy for the quantitative evaluation of the quantum shot noise.

Journal of Physics Conference Series•Mar 1, 2008•26 citations

An AC Josephson source for Johnson noise thermometry

Samuel P. Benz, John M. Martinis, Paul D. Dresselhaus +1 more

We have adapted the Josephson arbitrary waveform synthesizer to create a quantized voltage noise source suitable for calibrating the cross-correlation electronics of a Johnson noise thermometer system. The requirements of long term stability and low voltage amplitude allow dramatic simplification of the bias electronics compared to previous circuits. We describe the bias technique and the superconducting integrated circuit used to generate the pseudo-noise waveforms.

Conference on Precision Electromagnetic Measurements•Jun 25, 2003•3 citations

Characterization of programmable integrated quantum voltage noise source with variable power spectral density

Tomoya Irimatsugawa, Chiharu Urano, Takahiro Yamada

A quantum voltage noise source (QVNS) based on the Josephson effect as a reference signal is indispensable in precise Johnson noise thermometry (JNT) because it provides quantum accurate power spectral density (PSD) represented by some physical constants and design parameters. An integrated QVNS (IQVNS) device that integrates the circuit elements required for generation of a QVNS signal into one chip has been developed at AIST. The PSD of IQVNS should be variable for precise JNT measurement over a wide temperature range. Here, a new IQVNS device with variable PSD—programmable IQVNS—was developed and the values of the PSD were experimentally confirmed to be consistent with the theoretical values for various design parameters. Thus, JNT measurement over a wide temperature range can be realized with the IQVNS.

IEICE Electronics Express•Dec 20, 2021•0 citations

In situ calibration of microwave attenuation and gain using a cryogenic on-chip attenuator

Thomas Descamps, Linus Andersson, Vittorio Buccheri +3 more

Accurate in situ calibration of microwave attenuation and amplification-chain noise is essential for superconducting quantum circuits. We demonstrate a compact, self-calibrating cryogenic noise source based on an on-chip chromium attenuator that can be resistively heated with nanowatt-level power and directly integrated into a coaxial microwave line at the mixing-chamber stage. By comparing Johnson-Nyquist noise generated by Joule and microwave heating, measured through the amplification chain, the attenuation of the input line, and hence the gain of the chain, is determined without requiring knowledge of the attenuator temperature. The device exhibits millisecond-scale response times and negligible heating of the cryostat base plate. Using this approach, we determine the gain and added noise of a cryogenic amplification chain over the 4-8 GHz band. Our results provide a simple and accurate method to characterize near-quantum-limited parametric amplifiers used in superconducting-qubit readout.

quant-pharXiv:2602.16889•Feb 20, 2026•1 citation

Measurement of cross-correlated charge noise spectrum from transport currents through series-coupled silicon quantum dots

R. Matsuoka, T. Matsuda, R. Tsuchiya +6 more

Cross-correlated charge noise in silicon quantum dots has emerged as an important issue for fault-tolerant quantum computation, as it has been suggested to both limit quantum error correction performance and reveal unique information about noise sources. We develop a method to characterize charge noise cross-correlations in a semiconductor qubit device based solely on quantum-dot transport current. By dynamically switching the site-selective sensitivity of transport current through a double quantum dot to charge noise, we extract potential fluctuations at individual dots without requiring additional sensing devices or spin operations. Based on the obtained power spectral densities, we discuss the coupling of a dominant two-level fluctuator to individual dots. We furthermore verify the consistency of the measurement protocol by applying artificial noise via gate electrodes and investigate the temperature dependence of charge noise correlations. The method offers a convenient and versatile alternative approach that substantially facilitates the assessment of charge noise correlations in diverse semiconductor qubit devices.

Applied Physics Letters•Jun 1, 2026•0 citations

Calibration of cryogenic amplification chains using normal-metal–insulator–superconductor junctions

E. Hyyppä, M. Jenei, S. Masuda +8 more

Various applications of quantum devices call for an accurate calibration of cryogenic amplification chains. To this end, we present an experimentally feasible calibration scheme and use it to accurately measure the total gain and noise temperature of an amplification chain by employing normal-metal–insulator–superconductor (NIS) junctions. Our method is based on the radiation emitted by inelastic electron tunneling across voltage-biased NIS junctions. We derive an analytical expression that relates the generated power to the applied bias voltage which is the only control parameter of the device. After the setup has been characterized using a standard voltage reflection measurement, the total gain and the noise temperature are extracted by fitting the analytical expression to the microwave power measured at the output of the amplification chain. The 1σ uncertainty of the total gain of 51.84 dB appears to be of the order of 0.10 dB.

arXiv:1904.00794•Applied Physics Letters•May 13, 2019•13 citations
We describe the construction and operation of a two-channel noise detection system for measuring power and cross spectral densities of current fluctuations near 2MHz in electronic devices at low temperatures. The system employs cryogenic amplification and fast Fourier transform based spectral measurement. The gain and electron temperature are calibrated using Johnson noise thermometry. Full shot noise of 100pA can be resolved with an integration time of 10s. We report a demonstration measurement of bias-dependent current noise in a gate defined GaAs∕AlGaAs quantum point contact.
A quantum voltage noise source (QVNS) based on the Josephson effect as a reference signal is indispensable in precise Johnson noise thermometry (JNT) because it provides quantum accurate power spectral density (PSD) represented by some physical constants and design parameters. An integrated QVNS (IQVNS) device that integrates the circuit elements required for generation of a QVNS signal into one chip has been developed at AIST. The PSD of IQVNS should be variable for precise JNT measurement over a wide temperature range. Here, a new IQVNS device with variable PSD—programmable IQVNS—was developed and the values of the PSD were experimentally confirmed to be consistent with the theoretical values for various design parameters. Thus, JNT measurement over a wide temperature range can be realized with the IQVNS.
Accurate in situ calibration of microwave attenuation and amplification-chain noise is essential for superconducting quantum circuits. We demonstrate a compact, self-calibrating cryogenic noise source based on an on-chip chromium attenuator that can be resistively heated with nanowatt-level power and directly integrated into a coaxial microwave line at the mixing-chamber stage. By comparing Johnson-Nyquist noise generated by Joule and microwave heating, measured through the amplification chain, the attenuation of the input line, and hence the gain of the chain, is determined without requiring knowledge of the attenuator temperature. The device exhibits millisecond-scale response times and negligible heating of the cryostat base plate. Using this approach, we determine the gain and added noise of a cryogenic amplification chain over the 4-8 GHz band. Our results provide a simple and accurate method to characterize near-quantum-limited parametric amplifiers used in superconducting-qubit readout.
Cross-correlated charge noise in silicon quantum dots has emerged as an important issue for fault-tolerant quantum computation, as it has been suggested to both limit quantum error correction performance and reveal unique information about noise sources. We develop a method to characterize charge noise cross-correlations in a semiconductor qubit device based solely on quantum-dot transport current. By dynamically switching the site-selective sensitivity of transport current through a double quantum dot to charge noise, we extract potential fluctuations at individual dots without requiring additional sensing devices or spin operations. Based on the obtained power spectral densities, we discuss the coupling of a dominant two-level fluctuator to individual dots. We furthermore verify the consistency of the measurement protocol by applying artificial noise via gate electrodes and investigate the temperature dependence of charge noise correlations. The method offers a convenient and versatile alternative approach that substantially facilitates the assessment of charge noise correlations in diverse semiconductor qubit devices.
Various applications of quantum devices call for an accurate calibration of cryogenic amplification chains. To this end, we present an experimentally feasible calibration scheme and use it to accurately measure the total gain and noise temperature of an amplification chain by employing normal-metal–insulator–superconductor (NIS) junctions. Our method is based on the radiation emitted by inelastic electron tunneling across voltage-biased NIS junctions. We derive an analytical expression that relates the generated power to the applied bias voltage which is the only control parameter of the device. After the setup has been characterized using a standard voltage reflection measurement, the total gain and the noise temperature are extracted by fitting the analytical expression to the microwave power measured at the output of the amplification chain. The 1σ uncertainty of the total gain of 51.84 dB appears to be of the order of 0.10 dB.