Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Physics Conference Series

Measurement for quantum shot noise in a quantum point contact at low temperatures

Masayuki Hashisaka, Y Yamauchi, Shuji Nakamura, Shinya Kasai, Kensuke Kobayashi, Teruo Ono

Published Mar 1, 2008• 26 citations
Publisher

Abstract

We report an experimental development for the high-frequency shot noise measurement system in the 3 He- 4 He dilution refrigerator. The target frequency of the measurement was set to a few MHz with the cross correlation scheme adopted for high accuracy. The system was calibrated by measuring Johnson-Nyquist noise of the quantum point contact (QPC). We prove that our system has enough accuracy for the quantitative evaluation of the quantum shot noise.

DOI
10.1088/1742-6596/109/1/012013

Related papers

System for measuring auto- and cross correlation of current noise at low temperatures

L. DiCarlo, Y. Zhang, Douglas McClure +3 more

We describe the construction and operation of a two-channel noise detection system for measuring power and cross spectral densities of current fluctuations near 2MHz in electronic devices at low temperatures. The system employs cryogenic amplification and fast Fourier transform based spectral measurement. The gain and electron temperature are calibrated using Johnson noise thermometry. Full shot noise of 100pA can be resolved with an integration time of 10s. We report a demonstration measurement of bias-dependent current noise in a gate defined GaAs∕AlGaAs quantum point contact.

arXiv:cond-mat/0604018•Review of Scientific Instruments•Jul 1, 2006•79 citations

Bolometric detection of quantum shot noise in coupled mesoscopic systems

Masayuki Hashisaka, Yoshiaki Yamauchi, Shuji Nakamura +3 more

We demonstrate a scheme to detect the quantum shot noise in coupled mesoscopic systems. By applying the noise thermometry to the capacitively coupled quantum point contacts (QPCs) we prove that the noise temperature of one QPC is in perfect proportion to that of the other QPC which is driven to nonequilibrium to generate quantum shot noise. The present mesoscopic bolometry, which is sensitive to the energy flow of $\ensuremath{\sim}1\text{ }\text{fW}$, allows us to detect the energy exchange between quantum systems at finite frequency and can also be applied for diverse precise measurements.

arXiv:0806.4805•Physical Review B•Dec 17, 2008•25 citations

Shot-Noise-Limited Operation of a Fast Quantum-Point-Contact Charge Sensor

Madhu Thalakulam, W. W. Xue, Pan, Feng +5 more

We have operated a quantum point contact (QPC) charge detector in a radio frequency (RF) mode that allows fast charge detection in a bandwidth of tens of megahertz. We find that the charge sensitivity of the RF-QPC is limited not by the noise of a secondary amplifier, but by non-equilibrium noise f the QPC itself. We have performed frequency-resolved measurements of the noise within a 10 MHz bandwidth around our carrier wave. When averaged over our bandwidth, we find that the noise is in good agreement with the theory of photon-assisted shot noise. Our measurements also reveal strong frequency dependence of the noise, asymmetry with respect to the carrier wave, the appearance of sharp local maxima that are correlated with mechanical degrees of freedom in the sample, and noise suppression indicative of many-body physics near the 0.7 structure.

arXiv:0708.0861•Aug 7, 2007•9 citations

Bolometric Shot Noise Detection in Coupled Quantum Point Contacts

Masayuki Hashisaka, Yoshiaki Yamauchi, Shuji Nakamura +5 more

We demonstrate the on‐chip bolometric detection of the quantum shot noise emitted from a biased quantum point contact (source QPC) by using another QPC (detector QPC). These QPCs are capacitively coupled to each other to exchange high‐frequency (∼GHz) fluctuation. By applying the noise thermometry to both QPCs at several temperatures, we prove that the excess noise temperature of detector QPC is perfectly proportional to that of source QPC.

AIP conference proceedings•Jan 1, 2010•0 citations

Using a Quantum Dot as a High-Frequency Shot Noise Detector

Eugen Onac, Franck Balestro, L. H. Willems van Beveren +3 more

We present the experimental realization of a quantum dot (QD) operating as a high-frequency noise detector. Current fluctuations produced in a nearby quantum point contact (QPC) ionize the QD and induce transport through excited states. The resulting transient current through the QD represents our detector signal. We investigate its dependence on the QPC transmission and voltage bias. We observe and explain a quantum threshold feature and a saturation in the detector signal. This experimental and theoretical study is relevant in understanding the backaction of a QPC used as a charge detector.

arXiv:cond-mat/0604608•Physical Review Letters•May 1, 2006•135 citations

Intrinsic Noise Properties of Atomic Point Contact Displacement Detectors

Nathan E. Flowers-Jacobs, Dan R. Schmidt, Konrad W. Lehnert

We measure the noise added by an atomic point contact operated as a displacement detector. With a microwave technique, we increase the measurement speed of atomic point contacts by a factor of 500. The measurement is then fast enough to detect the resonant motion of a nanomechanical beam at frequencies up to 60 MHz and sensitive enough to observe the random thermal motion of the beam at 250 mK. We demonstrate a shot-noise limited imprecision of 2.3 fm/square root[Hz] and observe a 78 aN/square root[Hz] backaction force, yielding a total uncertainty in the beam's displacement that is 42 times the standard-quantum limit.

arXiv:cond-mat/0701536•Physical Review Letters•Mar 1, 2007•83 citations
We report an experimental development for the high-frequency shot noise measurement system in the 3 He- 4 He dilution refrigerator. The target frequency of the measurement was set to a few MHz with the cross correlation scheme adopted for high accuracy. The system was calibrated by measuring Johnson-Nyquist noise of the quantum point contact (QPC). We prove that our system has enough accuracy for the quantitative evaluation of the quantum shot noise.
We describe the construction and operation of a two-channel noise detection system for measuring power and cross spectral densities of current fluctuations near 2MHz in electronic devices at low temperatures. The system employs cryogenic amplification and fast Fourier transform based spectral measurement. The gain and electron temperature are calibrated using Johnson noise thermometry. Full shot noise of 100pA can be resolved with an integration time of 10s. We report a demonstration measurement of bias-dependent current noise in a gate defined GaAs∕AlGaAs quantum point contact.
We demonstrate a scheme to detect the quantum shot noise in coupled mesoscopic systems. By applying the noise thermometry to the capacitively coupled quantum point contacts (QPCs) we prove that the noise temperature of one QPC is in perfect proportion to that of the other QPC which is driven to nonequilibrium to generate quantum shot noise. The present mesoscopic bolometry, which is sensitive to the energy flow of $\ensuremath{\sim}1\text{ }\text{fW}$, allows us to detect the energy exchange between quantum systems at finite frequency and can also be applied for diverse precise measurements.
We have operated a quantum point contact (QPC) charge detector in a radio frequency (RF) mode that allows fast charge detection in a bandwidth of tens of megahertz. We find that the charge sensitivity of the RF-QPC is limited not by the noise of a secondary amplifier, but by non-equilibrium noise f the QPC itself. We have performed frequency-resolved measurements of the noise within a 10 MHz bandwidth around our carrier wave. When averaged over our bandwidth, we find that the noise is in good agreement with the theory of photon-assisted shot noise. Our measurements also reveal strong frequency dependence of the noise, asymmetry with respect to the carrier wave, the appearance of sharp local maxima that are correlated with mechanical degrees of freedom in the sample, and noise suppression indicative of many-body physics near the 0.7 structure.
We present the experimental realization of a quantum dot (QD) operating as a high-frequency noise detector. Current fluctuations produced in a nearby quantum point contact (QPC) ionize the QD and induce transport through excited states. The resulting transient current through the QD represents our detector signal. We investigate its dependence on the QPC transmission and voltage bias. We observe and explain a quantum threshold feature and a saturation in the detector signal. This experimental and theoretical study is relevant in understanding the backaction of a QPC used as a charge detector.
We measure the noise added by an atomic point contact operated as a displacement detector. With a microwave technique, we increase the measurement speed of atomic point contacts by a factor of 500. The measurement is then fast enough to detect the resonant motion of a nanomechanical beam at frequencies up to 60 MHz and sensitive enough to observe the random thermal motion of the beam at 250 mK. We demonstrate a shot-noise limited imprecision of 2.3 fm/square root[Hz] and observe a 78 aN/square root[Hz] backaction force, yielding a total uncertainty in the beam's displacement that is 42 times the standard-quantum limit.