We report measurements on two superconducting flux qubits coupled to a readout superconducting quantum interference device (SQUID). Two on-chip flux bias lines allow independent flux control of any two of the three elements, as illustrated by a two-dimensional qubit flux map. The application of microwaves yields a frequency-flux dispersion curve for 1- and 2-photon driving of the single-qubit excited state, and coherent manipulation of the single-qubit state results in Rabi oscillations and Ramsey fringes. This architecture should be scalable to many qubits and SQUIDs on a single chip.
We report measurements on two superconducting flux qubits coupled to a readout superconducting quantum interference device (SQUID). Two on-chip flux bias lines allow independent flux control of any two of the three elements, as illustrated by a two-dimensional qubit flux map. The application of microwaves yields a frequency-flux dispersion curve for 1- and 2-photon driving of the single-qubit excited state, and coherent manipulation of the single-qubit state results in Rabi oscillations and Ramsey fringes. This architecture should be scalable to many qubits and SQUIDs on a single chip.
Measurements of three-junction flux qubits, both single flux qubits and coupled flux qubits, using a coupled direct current superconducting quantum interference device (dc-SQUID) for readout are reported. The measurement procedure is described in detail. We performed spectroscopy measurements and coherent manipulations of the qubit states on a single flux qubit, demonstrating quantum energy levels and Rabi oscillations, with Rabi oscillation decay time T Rabi = 78 ns and energy relaxation time T 1 = 315 ns. We found that the value of T Rabi depends strongly on the mutual inductance between the qubit and the magnetic coil. We also performed spectroscopy measurements on inductively coupled flux qubits.
A superconducting flux qubit is inductively coupled to a superconducting quantum interference device (SQUID) magnetometer, capacitively shunted to form a 1.294-GHz resonator. The qubit-state-dependent resonator frequency is weakly probed with a microwave signal and detected with a microstrip SQUID amplifier. At a mean resonator occupation n=1.5 photons, the readout visibility is increased by a factor of 4.5 over that using a cryogenic semiconductor amplifier. As n is increased from 0.008 to 0.1, no reduction in T1 is observed, potentially enabling continuous monitoring of the qubit state.
We present experimental results on a microwave scheme for reading out a Josephson phase qubit. A capacitively shunted superconducting quantum interference device (SQUID) is used as a nonlinear resonator which is inductively coupled to the qubit. The flux state of the qubit is detected by measuring the amplitude and phase of a microwave pulse reflected from the SQUID resonator. By this low-dissipative method, the qubit state measurement time is reduced to 25 μs, which is much faster than the conventional readout performed by switching the SQUID to its nonzero dc voltage state. The readout scheme presented here allows for reading out multiple qubits using a single microwave line by employing frequency-division multiplexing.
Though superconducting qubits offer the potential for a scalable quantum computing architecture, the high-fidelity readout necessary to execute practical algorithms has thus far remained elusive. Moreover, achievements toward high fidelity have been accompanied by either long measurement times or demolition of the quantum state. In this dissertation, we address these issues with the novel integration of two ultralow-noise, superconducting amplifiers into separate dispersive flux qubit measurements. We first demonstrate a flux qubit inductively coupled to a 1.294-GHz nonlinear oscillator formed by a capacitively shunted DC SQUID. The frequency of the oscillator is modulated by the state of the qubit and is detected via microwave reflectometry. A microstrip SQUID (Superconducting QUantum Interference Device) amplifier (MSA) is used to increase the sensitivity of the measurement over that of a semiconductor amplifier. In the second experiment, we report measurements of a flux qubit coupled via a shared inductance to a quasi-lumped element 5.78-GHz readout resonator formed by the parallel combination of an interdigitated capacitor and a meander line inductor. The system noise is substantially reduced by a near-quantum-limited Josephson parametric amplifier (paramp).We present measurements of increased fidelity and reduced measurement backaction using the MSA at readout excitation levels as low as one hundredth of a photon in the readout resonator, observing a 4.5-fold increase in the readout visibility. Furthermore, at low readout excitation levels below one tenth of a photon in the readout resonator, no reduction in T1 is observed, potentially enabling continuous monitoring of the qubit state. Using the paramp, we demonstrate a continuous, high-fidelity readout with sufficient bandwidth and signal-to-noise ratio to resolve quantum jumps in the flux qubit. This is enabled by a readout which discriminates between the readout pointer state distributions to an error below one part in 1000. This, along with the ability to make many successive readouts in a time T1, permits the use of heralding to ensure initialization to a fiducial state, such as the ground state. This method enables us to eliminate errors due to spurious thermal population, increasing the fidelity to 93.9%. Finally, we use heralding to introduce a simple, fast qubit reset protocol without changing the system parameters to induce Purcell relaxation.
Frequency-selective readout for superconducting qubits opens up the way towards scaling qubit circuits without increasing the number of measurement lines. Here we demonstrate the readout of an array of 7 flux qubits located on the same chip using a single measurement line. Each qubit is placed near an individual λ/4 resonator which, in turn, is coupled to a common microwave transmission line. We performed spectroscopy and coherent manipulation of all qubits and determined their parameters in a single measurement run.
Though superconducting qubits offer the potential for a scalable quantum computing architecture, the high-fidelity readout necessary to execute practical algorithms has thus far remained elusive. Moreover, achievements toward high fidelity have been accompanied by either long measurement times or demolition of the quantum state. In this dissertation, we address these issues with the novel integration of two ultralow-noise, superconducting amplifiers into separate dispersive flux qubit measurements. We first demonstrate a flux qubit inductively coupled to a 1.294-GHz nonlinear oscillator formed by a capacitively shunted DC SQUID. The frequency of the oscillator is modulated by the state of the qubit and is detected via microwave reflectometry. A microstrip SQUID (Superconducting QUantum Interference Device) amplifier (MSA) is used to increase the sensitivity of the measurement over that of a semiconductor amplifier. In the second experiment, we report measurements of a flux qubit coupled via a shared inductance to a quasi-lumped element 5.78-GHz readout resonator formed by the parallel combination of an interdigitated capacitor and a meander line inductor. The system noise is substantially reduced by a near-quantum-limited Josephson parametric amplifier (paramp).We present measurements of increased fidelity and reduced measurement backaction using the MSA at readout excitation levels as low as one hundredth of a photon in the readout resonator, observing a 4.5-fold increase in the readout visibility. Furthermore, at low readout excitation levels below one tenth of a photon in the readout resonator, no reduction in T1 is observed, potentially enabling continuous monitoring of the qubit state. Using the paramp, we demonstrate a continuous, high-fidelity readout with sufficient bandwidth and signal-to-noise ratio to resolve quantum jumps in the flux qubit. This is enabled by a readout which discriminates between the readout pointer state distributions to an error below one part in 1000. This, along with the ability to make many successive readouts in a time T1, permits the use of heralding to ensure initialization to a fiducial state, such as the ground state. This method enables us to eliminate errors due to spurious thermal population, increasing the fidelity to 93.9%. Finally, we use heralding to introduce a simple, fast qubit reset protocol without changing the system parameters to induce Purcell relaxation.