I present the construction of a low-velocity intense source (LVIS) of laser-cooled neutral strontium using permanent ring magnets. The LVIS consists of a magneto-optical trap from which cold strontium is extracted in a well-collimated beam. I also present the development and implementation of a full suite of low-noise, high-bandwidth laser control electronics including a microcontroller unit. This microcontroller remotely controls and monitors the current driver, temperature controller, and PID lock circuit for each diode laser simultaneously. The current driver output is accurate to within 2 micro-amps and repeatable to with a few nano-amps. The noise spectral density of the current driver hits a floor of 10^(-10) amps per root Hz at ~50 Hz and has a modulation bandwidth of ~50 MHz. The PID lock-circuit includes a scan-balancing option that we have used to scan an AR coated laser diode ~30 GHz mode-hop free. I describe the construction of an 80 mW frequency doubled 461 nm laser system using PPKTP for cooling and trapping neutral strontium in the LVIS. The LVIS, the electronics systems, and the 461 nm laser system represent major milestones on the way to producing a matter-wave interferometer using Sr-87 ions. The interferometer is based on an optical Raman transition between the hyperfine ground states of the Sr-87 ion. The ions will be produced by exciting the strontium LVIS beam to an auto-ionizing state in the continuum. In the interferometer two half-pi pulses of light and one pi pulse will be delivered to the ions to split and recombine their wave functions. I present calculations of the predicted sensitivity and a discussion of the possible applications. I present a method for locking a 407.8 nm laser to the 5s doublet S J=1/2 to 5p doublet P J=3/2 strontium ion transition in a neutral vapor. I present calculations for the necessary vacuum levels for the experiment and describe the preparation and assembly of the vacuum apparatus. The major vacuum system consists of two connected elastomer sealed chambers: one at 10^(-7) Torr and the other at 10^(-10) Torr separated by a region of low conductance. I present a Sr vapor cell constructed from standard CF fittings that allows the strontium to be heated to ~730 C, which can also be run as a thermal beam. I present a method for protecting the viewports on small-form alkali-earth vapor cells using lead or indium foil during the evaporation of oxide layers. Finally, I report on the current status of the experiment as well as detail future work on the apparatus.
I present the construction of a low-velocity intense source (LVIS) of laser-cooled neutral strontium using permanent ring magnets. The LVIS consists of a magneto-optical trap from which cold strontium is extracted in a well-collimated beam. I also present the development and implementation of a full suite of low-noise, high-bandwidth laser control electronics including a microcontroller unit. This microcontroller remotely controls and monitors the current driver, temperature controller, and PID lock circuit for each diode laser simultaneously. The current driver output is accurate to within 2 micro-amps and repeatable to with a few nano-amps. The noise spectral density of the current driver hits a floor of 10^(-10) amps per root Hz at ~50 Hz and has a modulation bandwidth of ~50 MHz. The PID lock-circuit includes a scan-balancing option that we have used to scan an AR coated laser diode ~30 GHz mode-hop free. I describe the construction of an 80 mW frequency doubled 461 nm laser system using PPKTP for cooling and trapping neutral strontium in the LVIS. The LVIS, the electronics systems, and the 461 nm laser system represent major milestones on the way to producing a matter-wave interferometer using Sr-87 ions. The interferometer is based on an optical Raman transition between the hyperfine ground states of the Sr-87 ion. The ions will be produced by exciting the strontium LVIS beam to an auto-ionizing state in the continuum. In the interferometer two half-pi pulses of light and one pi pulse will be delivered to the ions to split and recombine their wave functions. I present calculations of the predicted sensitivity and a discussion of the possible applications. I present a method for locking a 407.8 nm laser to the 5s doublet S J=1/2 to 5p doublet P J=3/2 strontium ion transition in a neutral vapor. I present calculations for the necessary vacuum levels for the experiment and describe the preparation and assembly of the vacuum apparatus. The major vacuum system consists of two connected elastomer sealed chambers: one at 10^(-7) Torr and the other at 10^(-10) Torr separated by a region of low conductance. I present a Sr vapor cell constructed from standard CF fittings that allows the strontium to be heated to ~730 C, which can also be run as a thermal beam. I present a method for protecting the viewports on small-form alkali-earth vapor cells using lead or indium foil during the evaporation of oxide layers. Finally, I report on the current status of the experiment as well as detail future work on the apparatus.
The development of an all-solid-state systems of lasers is described for the cooling and probing of strontium ions in a radio-frequency (rf) trap. The Sr+ ions created within the rf trap are laser cooled by repeated cycling on the 422 nm 2S1/2 - 2P1/2 resonance transition. The 422 nm light was generated from a single mode 70 mW 844 nm diode laser, whose output was frequency doubled to 422 nm in a KNbO3 crystal inside a resonant enhancement cavity. Decays from the Sr+ upper resonance level into the 2D3/2 metastable state remove ions from the cooling cycle. This loss was prevented by driving the 1092 nm 2D3/2 - 2P1/2 transition using a Nd3+-doped fiber laser, diode-pumped at 826 nm. The 2S1/2 - 2D5/2 optical 'clock' transition at 674 nm has a natural linewidth of 0.4 Hz and may be probed with an AlGaInP laser diode. The laser diodes at 844 nm and 674 nm are both collimated using a piezo-mounted GRIN rod which also provides longitudinal mode selection. The spectral output is optically narrowed using resonant optical feedback.
A high-flux compact source of strontium atoms has been designed and built. We have investigated the feasibility of direct trapping of cold atoms from the atomic flux out of a hot oven. Our design uses a two-dimensional magneto-optical trap (MOT) with an additional laser beam that exerts a radiation force that is not counterbalanced to eject atoms (so-called ‘push’ beam), which is known as a 2D+ MOT configuration. This approach has been previously used for sodium, and has been extended to strontium in this work. Laser cooling of strontium typically requires multiple stages: effusion of atoms from an oven to produce an atomic beam, transverse collimation, a Zeeman slower and deflection before finally collecting atoms in a 3D MOT. A 2D+ MOT combines the Zeeman slowing, transverse collimation, and deflection into a single compact stage to provide a high-flux source suitable for applications such as matter-wave interferometry, atomic clocks and experimental studies of degenerate quantum gases. This thesis reports experimental work that has been carried out to develop and test an oven and the associated laser cooling apparatus for producing a source of cold strontium atoms which is straightforward to manufacture. We test the oven up to a temperature of To = 642 °C and measure a peak intensity of 6.8 × 1016 s−1 sr−1 and a flux of 2.9 × 1016 s−1. We typically operate the oven at To = 502 °C, for which the peak intensity and flux are 2.2 × 1015 s−1 sr−1 and 7.5 × 1014 s−1. A multi-channel nozzle made of graphite gives an angular divergence of 0.17 rad (10°) for the atomic beam. Trapping atoms directly from the thermal atomic beam into the MOT gives a maximum loading rate of 7.1 × 1010 s−1, without any laser light to repump atoms into the cooling cycle. We demonstrated a novel frequency stabilising technique for the laser by developing Zeeman-tunable modulation transfer spectroscopy in strontium with an inaccuracy of ±3.5 MHz and a frequency tuning range of 160 MHz. The initial aim of this thesis was to make a compact, high-flux strontium source suitable for quantum technology applications. During the course of this research, we participated in the preparation of a proposal for the construction of a large-scale atom interferometer based on the clock transition in strontium (87Sr) for the exploration of dark matter and gravitational waves (a project known as the Atom Interferometer Observatory and Network, AION). This changed the design requirements towards producing a higher flux (in particular of the isotope 87Sr), with compactness of the source being less important in ∼10 m scale apparatus.
We present the implementation and characterization of a slow, intense, and collimated rubidium atomic source for atom interferometry. The continuous87Rb cold atomic beam is produced by a new compact two-dimensional magneto-optical trap. And it is based on the 2D+MOT design but a much smaller size and a higher flux compared to our original LVIS system. The on-line detecting system developed over a combination of time-of-flight and fluorescence methods is used to optimize the beam parameters. The dependence of the beam flux on detuning and power are investigated in detail respectively, for cooling and pushing laser. The re-pumping laser power influence is also considered. With aError! Reference source not found.10 G/cm magnetic gradient, 3ΓError! Reference source not found. red detuning from resonance for cooling laser and 5ΓError! Reference source not found. red detuning for pushing laser, the obtained cold atomic beam has a high flux of 4.7×109atoms/s Error! Reference source not found. Error! Reference source not found. It has a narrow longitudinal velocity distribution with mean velocity 10 m/s and full width at half maximum (FWHM)Error! Reference source not found.2 m/sError! Reference source not found. The two-photo stimulated Raman transitions both in Doppler-free and Doppler-sensitive modes are first proceeded, and stable Raman-Ramsey fringes are achieved with twon/2 Error! Reference source not found. Raman pulses.
ABSTRACT In a ceramic vapor cell we have created a robust Sr magneto-optical trap that stores about 108 atoms with lifetimes>200 ms. We eliminate the 5p 1P14d 1D2*5p 3P2 leak and achieve a 10-fold improvement in trap lifetime byrepumping the 5p 3Po,2 dark states with 679 nm and 707 nm light. The observed lifetime is now limited by coldcollision losses, and we have preliminary measurements of the 2-body loss rate. Direct readout of the trap velocity distribution is possible using the narrow (7 kHz) 52 'S0----5p 3P1 intercombination line at 689 nm. We can also cool with this narrow transition and have achieved a 40-fold 1-D velocity compression for about 5% of the trapped atoms by applying this second-stage cooling. Keywords: Laser cooling, laser trapping, alkaline earths, cold collisions, frequency metrology 1. INTRODUCTION Laser cooling and trapping techniques have advanced to become an important tool of the atomic physics community, and in recent years there has been considerable interest in expanding the range of trapped elements. The alkalineearths, in particular, possess unique characteristics which make them interesting to trap. Studies of long-rangeatom-atom interactions are simplified because they have no hyperfine structure, and their narrow intercombinationtransitions make them excellent candidates for optical frequency standards. Furthermore, Doppler cooling with thesenarrow transitions can reduce temperatures to near the recoil limit.The most abundant alkaline earth isotopes have I =
This thesis describes experimental work towards developing a trapped ion quantum information processor. An existing ion trap apparatus was capable of trapping and laser-cooling single ions or small ion strings of 40 Ca+, and had been used for studies of quantum jumps and natural lifetime measurements in Ca. This thesis describes improvements in this apparatus, which have allowed the stability and the flexibility of experimental control of the ions to be greatly increased. This enabled experiments to read out the spin state of a single trapped ion, and to load ions with isotope selectivity through photoionization. The optical systems were improved by installation of new lasers, optical reference cavities, and a system of acousto-optic modulators for laser intensity switching and frequency control. The photon counting for fluorescence detection was improved, and a new photon time-of-arrival correlation circuit developed. This has permitted rapid and more sensitive detection of micromotion, and hence cancellation of stray fields in the trap. A study of resonant circuits in the low RF, high voltage (10 MHz, 1 kV) regime was carried out with a view to developing a new RF supply for the Paul trap with reduced noise and increased power. A new supply based on a helical resonator was built and used to trap ions. This technique has reduced noise and will permit higher secular frequencies to be attained in the future. A magnetic field B in the ion trap is used to define a quantization axis, and in one series of experiments was required to be of order 100 G to provide a substantial Zeeman splitting. A set of magnetic field coils to control the size and direction of B is described. The design of these posed some problems owing to an unforseen issue with the vacuum chamber. In short, it is magnetizable and acts to first approximation like a magnetic shield. The field coils had to be sufficiently substantial to produce the desired field at the ion even in the presence of this shielding effect, and dark resonance (and other) spectra with Zeeman splitting were obtained to calibrate the field using the ion as a probe. Finally, the thesis describes the successful loading of the ion trap by laser photoionization from a weak atomic beam. This involved two new lasers at 423 nm and 389 nm. Saturated absorption spectroscopy of neutral calcium is first described, then transverse excitation of an atomic beam in our vacuum chamber is used to identify all the main isotopes of calcium and confirm their abundances in our source (a heated sample of natural calcium). Finally, photoionization is used to load the trap. This has three advantages over electron-impact ionization. By avoiding an electron gun, we avoid charging of insulating patches and subsequent electric field drift as they discharge; the flux in the atomic beam and hence calcium (and other) deposits on the electrodes can be greatly reduced; and most importantly, the photoionization is isotope selective. Evidence is presented which suggests that even with an non-enriched source, the rare isotope 43 Ca can be loaded with reasonable efficiency. This isotope is advantageous for quantum information experiments for several reasons, but chiefly because its ground state hyperfine structure can act as a stable qubit.