Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEICE Technical Report; IEICE Tech. Rep.

Multiplexing Techniques for Read-Out Superconductive Sensor System Based on Single Flux Quantum Circuits

一希 青木, 裕希 山梨, 信行 吉川

Published Jul 12, 2012• 0 citations
OpenAlex

Related papers

A Time-Domain SQUID Multiplexer System for Read-Out of Superconducting Transition-Edge-Sensor Arrays

C. D. Reintsema, James A. Beall, Steven W. Deiker +9 more

•Jul 7, 2003•1 citation

Multiplexing Techniques of Single Flux Quantum Circuit Based Readout Circuit for a Multi-Channel Sensing System

Kenta Aoki, Yuki Yamanashi, Nobuyuki Yoshikawa

Time division multiplexing (TDM) and code division multiplexing (CDM) have been investigated for multichannel superconductive sensing systems using single-flux-quantum (SFQ) readout circuits. Output data from a superconductive sensor array can be multiplexed using SFQ binary counters, which count the number of SFQ pulses from each sensor, and are transmitted from a low-temperature environment to a room-temperature equipment using a small number of lines. We have estimated and compared the performance of a multichannel superconductive sensing system that employs TDM and CDM on the basis of analog circuit simulation and circuit design results. TDM is useful for reducing the number of lines, but the slew rate of the sensing system decreases with an increase in the number of channels. On the other hand, in the case of CDM, the slew rate of the system does not decrease with an increase in the number of channels. We have designed and tested a 2-channel digital superconducting quantum interference device system that can perform TDM and CDM employing SFQ up/down binary counters. In both circuits, the 16 Φ0input waveforms were reconstructed from the measured data, with an error of less than the flux quantum Φ0.

IEEE Transactions on Applied Superconductivity•Nov 28, 2012•7 citations

Readout System for Frequency-Division Multiplexing Superconducting Detector Arrays

Xiaohui Yan, Fei Liu, Ran P. Duan +4 more

Journal of Low Temperature Physics•May 18, 2024•2 citations

Single-flux quantum multiplexer for multi-pixel superconducting single-photon detector arrays

M. Hofherr, K. Ilin, Dagmar Rall +9 more

•Jan 1, 2011•0 citations

Integrated Superconducting Transition-Edge-Sensor Energy Readout (ISTER)

S. W. Leman, Evan B. Golden, Matthew C. Guyton +2 more

We describe a million-pixel-scale multiplexed readout for superconducting Transition Edge Sensor (TES) microcalorimeters, using Rapid Single Flux Quantum (RSFQ) digital circuits. Depending on the application and the power dissipation requirements, the readout circuits may be either fabricated on the same wafer as the TES or integrated with the TES wafer using a multichip module, thereby integrating the TES and readout circuits. A data reduction scheme in the RSFQ circuits is described, using integrating counters to measure the TES pulse area. Power and clock requirements for measuring a large number of TES channels per readout line are discussed. Basic components of the ISTER readout circuit have been fabricated in the SFQ5ee process at MIT Lincoln Laboratory and operated at 4 K. The fabrication process has eight fully planarized Nb layers and one layer of Nb/Al-AlOx/Nb Josephson junctions with 100$\mu$A/$\mu$m$^{2}$critical current density. Simulations of a TES read out are performed to investigate possible limits on energy resolution using ISTER.

IEEE Transactions on Applied Superconductivity•May 3, 2023•3 citations

Multiplexing techniques for detector applications - basics and its realization in superconducting electronics

Sebastian Kempf

•Jan 1, 2018•0 citations
Time division multiplexing (TDM) and code division multiplexing (CDM) have been investigated for multichannel superconductive sensing systems using single-flux-quantum (SFQ) readout circuits. Output data from a superconductive sensor array can be multiplexed using SFQ binary counters, which count the number of SFQ pulses from each sensor, and are transmitted from a low-temperature environment to a room-temperature equipment using a small number of lines. We have estimated and compared the performance of a multichannel superconductive sensing system that employs TDM and CDM on the basis of analog circuit simulation and circuit design results. TDM is useful for reducing the number of lines, but the slew rate of the sensing system decreases with an increase in the number of channels. On the other hand, in the case of CDM, the slew rate of the system does not decrease with an increase in the number of channels. We have designed and tested a 2-channel digital superconducting quantum interference device system that can perform TDM and CDM employing SFQ up/down binary counters. In both circuits, the 16 Φ0input waveforms were reconstructed from the measured data, with an error of less than the flux quantum Φ0.
We describe a million-pixel-scale multiplexed readout for superconducting Transition Edge Sensor (TES) microcalorimeters, using Rapid Single Flux Quantum (RSFQ) digital circuits. Depending on the application and the power dissipation requirements, the readout circuits may be either fabricated on the same wafer as the TES or integrated with the TES wafer using a multichip module, thereby integrating the TES and readout circuits. A data reduction scheme in the RSFQ circuits is described, using integrating counters to measure the TES pulse area. Power and clock requirements for measuring a large number of TES channels per readout line are discussed. Basic components of the ISTER readout circuit have been fabricated in the SFQ5ee process at MIT Lincoln Laboratory and operated at 4 K. The fabrication process has eight fully planarized Nb layers and one layer of Nb/Al-AlOx/Nb Josephson junctions with 100μ\muμA/μ\muμm2^{2}2critical current density. Simulations of a TES read out are performed to investigate possible limits on energy resolution using ISTER.