Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Recirculation of Laser Power in an Atomic Fountain

Daphna G. Enzer, William M. Klipstein, James D P Moore

Published Mar 1, 2007• 0 citations
OpenAlex

Abstract

A new technique for laser-cooling atoms in a cesium atomic fountain frequency standard relies on recirculation of laser light through the atom-collection region of the fountain. The recirculation, accomplished by means of reflections from multiple fixed beam-splitter cubes, is such that each of two laser beams makes three passes. As described below, this recirculation scheme offers several advantages over prior designs, including simplification of the laser system, greater optical power throughput, fewer optical and electrical connections, and simplification of beam power balancing. A typical laser-cooled cesium fountain requires the use of six laser beams arranged as three orthogonal pairs of counter-propagating beams to decelerate the atoms and hold them in a three-dimensional optical trap in vacuum. Typically, these trapping/cooling beams are linearly polarized and are positioned and oriented so that (1) counter-propagating beams in each pair have opposite linear polarizations and (2) three of the six orthogonal beams have the sum of their propagation directions pointing up, while the other three have the sum of their propagation directions pointing down. In a typical prior design, two lasers are used - one to generate the three "up" beams, the other to generate the three "down" beams. For this purpose, the output of each laser is split three ways, then the resulting six beams are delivered to the vacuum system, independently of each other, via optical fibers. The present recirculating design also requires two lasers, but the beams are not split before delivery. Instead, only one "up" beam and one oppositely polarized "down" beam are delivered to the vacuum system, and each of these beams is sent through the collection region three times. The polarization of each beam on each pass through the collection region is set up to yield the same combination of polarization and propagation directions as described above. In comparison with the prior design, the present recirculating design utilizes the available laser light more efficiently, making it possible to trap more atoms at a given laser power or the same number of atoms at a lower laser power. The present design is also simpler in that it requires fewer optical fibers, fiber couplings, and collimators, and fewer photodiodes for monitoring beam powers. Additionally, the present design alleviates the difficulty of maintaining constant ratios among power levels of the beams within each "up" or "down" triplet.

Related papers

Laser cooling and trapping experiments for cesium atoms in NRLM

Takeshi Ikegami, Takayuki Kurosu, Shinichi Ohshima +1 more

Present status of laser cooling experiments in NRLM is presented. Laser cooling and trapping experiments for cesium atoms are continued in NRLM to develop an atomic fountain frequency standard. As a first step, we performed Cs atomic beam deceleration and trapping experiments. Atomic beam cesium atoms were decelerated by counterpropagating radiation from semiconductor laser diodes. The laser frequency was chirped to keep it in resonance with the decelerated atoms. The decelerated atoms were trapped by six mutually orthogonal laser beams in a magneto-optical trap configuration. The atoms could also be trapped directly from ambient cesium gas in a glass cell without using the deceleration laser beam. The characteristics of the trapped atoms are reported.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 30, 1993•0 citations

Laser-cooled cesium atomic fountain experiment for atomic frequency standard

Jun Umezu, Yasusada Ohta, K. Hukuda +2 more

A cesium frequency standard based on the atomic fountain configuration has the potential of improving the accuracy of primary frequency standard. For the first step toward a realization of slow vertical atomic beam (that is an atomic fountain), we have succeeded to decelerate the horizontal cesium atomic beam by laser cooling with the Zeeman tuning method. Then those slowed atoms are confined with a magneto-optical trap by four laser beams in the tetrahedral configuration. By using these trapped atoms, one can launch them upward with the upstream laser pulses.>

Conference proceedings - IEEE Instrumentation/Measurement Technology Conference•Dec 17, 2002•0 citations

A low velocity intense source of atoms

Zheng‐Tian Lu, Kristan L. Corwin, Michael J. Renn +3 more

The authors have demonstrated a new method of generating a slow, collimated atomic beam. In this experiment, 87Rb atoms were first collected into a standard MOT with six laser beams. One of the beams was blocked in the center by an opaque spot, causing an imbalance of light force in a column along the axis of this laser beam. Consequently, the atoms in the trap were pushed out along the axis and form a slow, collimated beam. This configuration uses atoms efficiently, because those atoms which leave the shadow of the opaque spot while inside the capture volume of the trap are recirculated. This scheme is a simple, cost-effective way of generating cold atomic beams for many experiments, fiber guiding of atoms, atomic interferometry, and transporting atoms in a double-MOT system.

Bulletin of the American Physical Society•May 1, 1996•0 citations

Optimization of laser collimator characteristics for enhanced performance in a rubidium atomic fountain clock

Yang Bai, Hui Zhang, Sichen Fan +2 more

The rubidium atomic fountain clock NTSC-RbF2 at the National Time Service Center (NTSC) operates in a (1,1,1) atomic fountain configuration, where six cooling laser beams are symmetrically arranged in pairs to form three orthogonal standing-wave fields in three-dimensional space. These fields are critical for efficient capture and laser cooling of ultracold atoms. Laser collimators convert the output beams from the laser system into parallel or quasi-parallel spatial profiles, which are essential for precise atom-light interactions. The collimators must meet stringent requirements for optical power, polarization, collimation, directionality, and spatial uniformity. These parameters significantly affect the spatial distribution and population of trapped atoms, directly influencing the signal-to-noise ratio (SNR) of the Ramsey interference signal. Moreover, the number of detected atoms determines the quantum projection noise limit, a key factor of the clock’s second-level frequency stability. To enhance the atom detection efficiency, the collimator tubes were meticulously designed and optimized to improve their collimation, directionality, and uniformity. Following precise alignment, the divergence angle of the output laser beam from each of the six collimators was reduced to below 0.1 mrad (collimation), the angular deviation between the output laser beam and the mechanical axis of the collimator was minimized to less than 0.1′ (directionality), and the spatial offset between the center of the output laser spot and the mechanical center of the collimator was confined to within 2 mm (uniformity). In comparison to its predecessor, NTSC-RbF1, the quantum projection noise contribution to the clock's second-level frequency stability was reduced from 1.39×10-13 to 8.26×10-14.

Applied Optics and Photonics China (AOPC)•Oct 28, 2025•0 citations

Laser cooling and trapping of Cs-133 neutral atoms at CENAM

M. Talavera-Ortega, J. M. López Romero, E. de Carlos López

At the moment the National Center of Metrology (CENAM) develops to the necessary technology for the creation of a frequency standard of high accuracy denominated CsF1 atomic fountain. The first stage of development of this clock consists of laser cooling and trapping neutral Cs-133 atoms. The mechanism of laser cooling and trapping of atoms requires of the accomplishment of a magneto-optical trap (MOT) in where is indispensable to maintain a strict control in its parameters of operation. In this experiment, the MOT operates with three set of red detuning |62s1/2, F=4|-> |62s3/2, F'=5| cyclical transition of Cs-133, mutually orthogonal, counterpropagating laser beams, with opposite circular polarization, intersecting at the center of a magnetic field which is generated by a pair of coil in anti-Helmholtz configuration. Additionally, a beam of light that comes from a repumping laser, tuned to the frequency of the |62s1/2, F=3|->|62s3/2, F'=4| transition of Cs-133, is injected to the MOT to maintain an atoms population in the |62s1/2, F=4| state. To cool and trap atoms to so low temperatures, of the order of the microkelvins on the zero absolute, by several seconds, minutes or even by several hours, provided the fundamentals tools to us to study the temporal and spatial behavior of the fluorescence of the atomic cloud and to make exact measurements in the count of such, in order to deduce the parameters of operation of the MOT that allows us to trap 1010 atoms or more. In this work the theoretical concepts as well as the experimental details of the parameters of operation of the MOT for the formation of the cold atom cloud are approached.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 13, 2006•0 citations

Progress on the construction of an atomic cesium fountain at NIM

Tianchu Li, Mingshou Li, Huang Bingying +2 more

An atomic cesium fountain has been designed for a new primary standard of frequency in China. Cold atomic clouds collected in the magneto-optical trap (MOT) were previously reported (1995). To further improve the performance of the MOT we have optimized the laser-optical system and operation of the MOT. Some optical elements were replaced with new ones with better quality; frequency stabilization of lasers and arrangement of the optical system was modified; and polarization maintaining (PM) optical fibers were adopted to transfer lights from the optical system to MOT. We also installed the fluorescence detecting - amplifying assembles to take the time of flight (TOF) measurement of the cold atoms.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 13, 2002•1 citation
A new technique for laser-cooling atoms in a cesium atomic fountain frequency standard relies on recirculation of laser light through the atom-collection region of the fountain. The recirculation, accomplished by means of reflections from multiple fixed beam-splitter cubes, is such that each of two laser beams makes three passes. As described below, this recirculation scheme offers several advantages over prior designs, including simplification of the laser system, greater optical power throughput, fewer optical and electrical connections, and simplification of beam power balancing. A typical laser-cooled cesium fountain requires the use of six laser beams arranged as three orthogonal pairs of counter-propagating beams to decelerate the atoms and hold them in a three-dimensional optical trap in vacuum. Typically, these trapping/cooling beams are linearly polarized and are positioned and oriented so that (1) counter-propagating beams in each pair have opposite linear polarizations and (2) three of the six orthogonal beams have the sum of their propagation directions pointing up, while the other three have the sum of their propagation directions pointing down. In a typical prior design, two lasers are used - one to generate the three "up" beams, the other to generate the three "down" beams. For this purpose, the output of each laser is split three ways, then the resulting six beams are delivered to the vacuum system, independently of each other, via optical fibers. The present recirculating design also requires two lasers, but the beams are not split before delivery. Instead, only one "up" beam and one oppositely polarized "down" beam are delivered to the vacuum system, and each of these beams is sent through the collection region three times. The polarization of each beam on each pass through the collection region is set up to yield the same combination of polarization and propagation directions as described above. In comparison with the prior design, the present recirculating design utilizes the available laser light more efficiently, making it possible to trap more atoms at a given laser power or the same number of atoms at a lower laser power. The present design is also simpler in that it requires fewer optical fibers, fiber couplings, and collimators, and fewer photodiodes for monitoring beam powers. Additionally, the present design alleviates the difficulty of maintaining constant ratios among power levels of the beams within each "up" or "down" triplet.
Present status of laser cooling experiments in NRLM is presented. Laser cooling and trapping experiments for cesium atoms are continued in NRLM to develop an atomic fountain frequency standard. As a first step, we performed Cs atomic beam deceleration and trapping experiments. Atomic beam cesium atoms were decelerated by counterpropagating radiation from semiconductor laser diodes. The laser frequency was chirped to keep it in resonance with the decelerated atoms. The decelerated atoms were trapped by six mutually orthogonal laser beams in a magneto-optical trap configuration. The atoms could also be trapped directly from ambient cesium gas in a glass cell without using the deceleration laser beam. The characteristics of the trapped atoms are reported.
A cesium frequency standard based on the atomic fountain configuration has the potential of improving the accuracy of primary frequency standard. For the first step toward a realization of slow vertical atomic beam (that is an atomic fountain), we have succeeded to decelerate the horizontal cesium atomic beam by laser cooling with the Zeeman tuning method. Then those slowed atoms are confined with a magneto-optical trap by four laser beams in the tetrahedral configuration. By using these trapped atoms, one can launch them upward with the upstream laser pulses.>
The authors have demonstrated a new method of generating a slow, collimated atomic beam. In this experiment, 87Rb atoms were first collected into a standard MOT with six laser beams. One of the beams was blocked in the center by an opaque spot, causing an imbalance of light force in a column along the axis of this laser beam. Consequently, the atoms in the trap were pushed out along the axis and form a slow, collimated beam. This configuration uses atoms efficiently, because those atoms which leave the shadow of the opaque spot while inside the capture volume of the trap are recirculated. This scheme is a simple, cost-effective way of generating cold atomic beams for many experiments, fiber guiding of atoms, atomic interferometry, and transporting atoms in a double-MOT system.
The rubidium atomic fountain clock NTSC-RbF2 at the National Time Service Center (NTSC) operates in a (1,1,1) atomic fountain configuration, where six cooling laser beams are symmetrically arranged in pairs to form three orthogonal standing-wave fields in three-dimensional space. These fields are critical for efficient capture and laser cooling of ultracold atoms. Laser collimators convert the output beams from the laser system into parallel or quasi-parallel spatial profiles, which are essential for precise atom-light interactions. The collimators must meet stringent requirements for optical power, polarization, collimation, directionality, and spatial uniformity. These parameters significantly affect the spatial distribution and population of trapped atoms, directly influencing the signal-to-noise ratio (SNR) of the Ramsey interference signal. Moreover, the number of detected atoms determines the quantum projection noise limit, a key factor of the clock’s second-level frequency stability. To enhance the atom detection efficiency, the collimator tubes were meticulously designed and optimized to improve their collimation, directionality, and uniformity. Following precise alignment, the divergence angle of the output laser beam from each of the six collimators was reduced to below 0.1 mrad (collimation), the angular deviation between the output laser beam and the mechanical axis of the collimator was minimized to less than 0.1′ (directionality), and the spatial offset between the center of the output laser spot and the mechanical center of the collimator was confined to within 2 mm (uniformity). In comparison to its predecessor, NTSC-RbF1, the quantum projection noise contribution to the clock's second-level frequency stability was reduced from 1.39×10-13 to 8.26×10-14.
At the moment the National Center of Metrology (CENAM) develops to the necessary technology for the creation of a frequency standard of high accuracy denominated CsF1 atomic fountain. The first stage of development of this clock consists of laser cooling and trapping neutral Cs-133 atoms. The mechanism of laser cooling and trapping of atoms requires of the accomplishment of a magneto-optical trap (MOT) in where is indispensable to maintain a strict control in its parameters of operation. In this experiment, the MOT operates with three set of red detuning |62s1/2, F=4|-> |62s3/2, F'=5| cyclical transition of Cs-133, mutually orthogonal, counterpropagating laser beams, with opposite circular polarization, intersecting at the center of a magnetic field which is generated by a pair of coil in anti-Helmholtz configuration. Additionally, a beam of light that comes from a repumping laser, tuned to the frequency of the |62s1/2, F=3|->|62s3/2, F'=4| transition of Cs-133, is injected to the MOT to maintain an atoms population in the |62s1/2, F=4| state. To cool and trap atoms to so low temperatures, of the order of the microkelvins on the zero absolute, by several seconds, minutes or even by several hours, provided the fundamentals tools to us to study the temporal and spatial behavior of the fluorescence of the atomic cloud and to make exact measurements in the count of such, in order to deduce the parameters of operation of the MOT that allows us to trap 1010 atoms or more. In this work the theoretical concepts as well as the experimental details of the parameters of operation of the MOT for the formation of the cold atom cloud are approached.
An atomic cesium fountain has been designed for a new primary standard of frequency in China. Cold atomic clouds collected in the magneto-optical trap (MOT) were previously reported (1995). To further improve the performance of the MOT we have optimized the laser-optical system and operation of the MOT. Some optical elements were replaced with new ones with better quality; frequency stabilization of lasers and arrangement of the optical system was modified; and polarization maintaining (PM) optical fibers were adopted to transfer lights from the optical system to MOT. We also installed the fluorescence detecting - amplifying assembles to take the time of flight (TOF) measurement of the cold atoms.