Applied Optics and Photonics China (AOPC)

Optimization of laser collimator characteristics for enhanced performance in a rubidium atomic fountain clock

Yang Bai, Hui Zhang, Sichen Fan, Fan Liu, Jun Ruan

Published Oct 28, 2025• 0 citations
Publisher

Abstract

The rubidium atomic fountain clock NTSC-RbF2 at the National Time Service Center (NTSC) operates in a (1,1,1) atomic fountain configuration, where six cooling laser beams are symmetrically arranged in pairs to form three orthogonal standing-wave fields in three-dimensional space. These fields are critical for efficient capture and laser cooling of ultracold atoms. Laser collimators convert the output beams from the laser system into parallel or quasi-parallel spatial profiles, which are essential for precise atom-light interactions. The collimators must meet stringent requirements for optical power, polarization, collimation, directionality, and spatial uniformity. These parameters significantly affect the spatial distribution and population of trapped atoms, directly influencing the signal-to-noise ratio (SNR) of the Ramsey interference signal. Moreover, the number of detected atoms determines the quantum projection noise limit, a key factor of the clock’s second-level frequency stability. To enhance the atom detection efficiency, the collimator tubes were meticulously designed and optimized to improve their collimation, directionality, and uniformity. Following precise alignment, the divergence angle of the output laser beam from each of the six collimators was reduced to below 0.1 mrad (collimation), the angular deviation between the output laser beam and the mechanical axis of the collimator was minimized to less than 0.1′ (directionality), and the spatial offset between the center of the output laser spot and the mechanical center of the collimator was confined to within 2 mm (uniformity). In comparison to its predecessor, NTSC-RbF1, the quantum projection noise contribution to the clock's second-level frequency stability was reduced from 1.39×10-13 to 8.26×10-14.

DOI
10.1117/12.3083171

Related papers

An intense, highly collimated continuous Cesium fountain

N. Castagna

The realisation of cold and slow atomic beams has opened the way to a series of precision measurements of high scientific interest, as atom interferometry, Bose-Einstein Condensation and atomic fountain clocks. The latter are used since several years as reference clocks, given the high performance that they can reach both in accuracy and stability. The common philosophy in the construction of atomic fountains has been the pulsed technique, where an atoms sample is launched vertically and then falls down under the effect of the gravity. The Observatoire de Neuchâtel had a different approach and has built a fountain clock (FOCS1) operating in a continuous mode. This technique offers two main advantages: the diminution of the undesirable effects due to the atomic density (e.g. collisions between the atoms and cavity pulling) and to the noise of the local oscillator (intermodulation effect). To take full advantage of the continuous fountain approach however, we need to increase the atomic flux. The techniques chosen to reach this goal are an efficient transverse collimation together with more atoms to begin with. Here we report on a study of different transverse collimation techniques performed in a two-dimensional phase stable optical lattice (namely gray molasses and magnetically induced laser cooling) as well as the development and characterisation of a 2D-magneto-optical trap used to load the fountain. Best performances are reached in a 2D+-MOT configuration of such a pre-source, for which we detect an atomic flux 20 times greater than the one measured when the fountain is loaded by a Cs vapour. This gain could improve the atomic clock stability by a factor 6. An even better stability is expected after introducing a pre-cooling stage before performing the transverse collimation. This new configuration is currently under investigation and will be implemented in a second continuous fountain (FOCS2).

•Jan 1, 2006•0 citations

An intense, highly collimated continous cesium fountain

N. Castagna

The realisation of cold and slow atomic beams has opened the way to a series of precision measurements of high scientific interest, as atom interferometry, Bose-Einstein Condensation and atomic fountain clocks. The latter are used since several years as reference clocks, given the high performance that they can reach both in accuracy and stability. The common philosophy in the construction of atomic fountains has been the pulsed technique, where an atoms sample is launched vertically and then falls down under the effect of the gravity. The Observatoire de Neuchâtel had a different approach and has built a fountain clock (FOCS1) operating in a continuous mode. This technique offers two main advantages: the diminution of the undesirable effects due to the atomic density (e.g. collisions between the atoms and cavity pulling) and to the noise of the local oscillator (intermodulation effect). To take full advantage of the continuous fountain approach however, we need to increase the atomic flux. The techniques chosen to reach this goal are an efficient transverse collimation together with more atoms to begin with. Here we report on a study of different transverse collimation techniques performed in a two-dimensional phase stable optical lattice (namely gray molasses and magnetically induced laser cooling) as well as the development and characterisation of a 2D-magneto-optical trap used to load the fountain. Best performances are reached in a 2D+-MOT configuration of such a pre-source, for which we detect an atomic flux 20 times greater than the one measured when the fountain is loaded by a Cs vapour. This gain could improve the atomic clock stability by a factor 6. An even better stability is expected after introducing a pre-cooling stage before performing the transverse collimation. This new configuration is currently under investigation and will be implemented in a second continuous fountain (FOCS2).

•Jan 1, 2006•0 citations

Recirculation of Laser Power in an Atomic Fountain

Daphna G. Enzer, William M. Klipstein, James D P Moore

A new technique for laser-cooling atoms in a cesium atomic fountain frequency standard relies on recirculation of laser light through the atom-collection region of the fountain. The recirculation, accomplished by means of reflections from multiple fixed beam-splitter cubes, is such that each of two laser beams makes three passes. As described below, this recirculation scheme offers several advantages over prior designs, including simplification of the laser system, greater optical power throughput, fewer optical and electrical connections, and simplification of beam power balancing. A typical laser-cooled cesium fountain requires the use of six laser beams arranged as three orthogonal pairs of counter-propagating beams to decelerate the atoms and hold them in a three-dimensional optical trap in vacuum. Typically, these trapping/cooling beams are linearly polarized and are positioned and oriented so that (1) counter-propagating beams in each pair have opposite linear polarizations and (2) three of the six orthogonal beams have the sum of their propagation directions pointing up, while the other three have the sum of their propagation directions pointing down. In a typical prior design, two lasers are used - one to generate the three "up" beams, the other to generate the three "down" beams. For this purpose, the output of each laser is split three ways, then the resulting six beams are delivered to the vacuum system, independently of each other, via optical fibers. The present recirculating design also requires two lasers, but the beams are not split before delivery. Instead, only one "up" beam and one oppositely polarized "down" beam are delivered to the vacuum system, and each of these beams is sent through the collection region three times. The polarization of each beam on each pass through the collection region is set up to yield the same combination of polarization and propagation directions as described above. In comparison with the prior design, the present recirculating design utilizes the available laser light more efficiently, making it possible to trap more atoms at a given laser power or the same number of atoms at a lower laser power. The present design is also simpler in that it requires fewer optical fibers, fiber couplings, and collimators, and fewer photodiodes for monitoring beam powers. Additionally, the present design alleviates the difficulty of maintaining constant ratios among power levels of the beams within each "up" or "down" triplet.

•Mar 1, 2007•0 citations

Improvement of the short-term stability of atomic fountain clock with state preparation by two-laser optical pumping*

Lei Han, Fang Fang, Weiliang Chen +4 more

To improve the signal to noise ratio (SNR) and the short-term stability of cesium atomic fountain clocks, the work of two-laser optical pumping is presented theoretically and experimentally. The short-term stability of the NIM6 fountain clock has been improved by preparing more cold atoms in the | F = 4, mF = 0〉 clock state with a shortened cycle time. Two π-polarized laser beams overlapped in the horizontal plane have been applied after launching, one is resonant with | F = 4〉 → | F′ = 4〉 transition and the other is resonant with | F = 3〉 → | F′ = 4〉 transition. With optical pumping, the population accumulated in the | mF = 0〉 clock state is improved from 11% to 63%, and the detection signal is increased by a factor of 4.2, the SNR of the clock transition probability and the short-term stability are also improved accordingly.

Chinese Physics B•Feb 2, 2021•4 citations

Proposal of a truncated atomic beam fountain for reduction of collisional frequency shift

Akifumi Takamizawa, Y. Shirakawa, Shinya Yanagimachi +1 more

We propose an atomic fountain clock with a truncated cold atomic beam to achieve both a low collisional frequency shift and high frequency stability. In this clock, the launching velocity of a cold atomic beam can be swept to reduce the atomic density in the interrogation region for the Ramsey resonance and to increase the atomic density in the detection region. Before the top of the beam arrives at the interrogation region, the cold atomic beam is truncated by turning off the cooling laser beams to remove the unnecessary light shift. The atomic density in the interrogation region is theoretically evaluated to be 0.04 times that in an ordinary atomic fountain with optical molasses for the same number of detected atoms. The frequency stability limit due to quantum projection noise is calculated to reach $6.4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$ in 1 s from the number of detected atoms while the fractional collisional shift is estimated to be $~\ensuremath{-}2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$.

Physical Review A•Jul 26, 2010•1 citation

Article

Marie-Claude Gagné, J.-S. Boulanger, R.J. Douglas

The accelerated development of laser methods for manipulating the internal state and motion of atoms, and the recent primary evaluation in France of a cesium frequency standard using cold atoms in an atomic fountain configuration, allow the frontiers of time metrology, accuracy, and stability to be pushed near parts in the 1016 level, a factor of 100 over the present primary laboratory clocks. These positive results revived the development of more accurate cesium atomic clocks, and the Institute of National Measurement Standards (INMS), of the National Research Council of Canada (NRC) is undertaking a cesium-fountain project aimed at reaching these new levels of accuracy and stability. This paper reviews its present status. To appreciate the considerable impact of cold atoms in time and frequency metrology, we begin by recalling the background principles of traditional cesium frequency standards, their typical performance and main limitations. After introducing the important theoretical results essential to understanding the techniques of laser cooling and magneto-optical trapping, we focus on describing the characterization and control of our magneto-optical trap (MOT) and report the parameters that allow us to fill the trap with a few million atoms in less than a second and cool them to a temperature lower than 5 muK using optical molasses. We will describe the specifics of our cesium-fountain prototype, which operates with a 2-dimensional moving molasses. This special configuration is applicable for multipulse operation of the fountain, which can greatly relax the local oscillator requirements for time keeping. Finally, progress toward our objective of launching cooled atoms, at a rate of one ensemble per second, at speeds of 7 m/s, for a fountain with an interrogation time of about 1 s, will be analysed.PACS Nos.: 06.20, 06.30, and 32.80P

Canadian Journal of Physics•Jan 1, 1998•1 citation
The rubidium atomic fountain clock NTSC-RbF2 at the National Time Service Center (NTSC) operates in a (1,1,1) atomic fountain configuration, where six cooling laser beams are symmetrically arranged in pairs to form three orthogonal standing-wave fields in three-dimensional space. These fields are critical for efficient capture and laser cooling of ultracold atoms. Laser collimators convert the output beams from the laser system into parallel or quasi-parallel spatial profiles, which are essential for precise atom-light interactions. The collimators must meet stringent requirements for optical power, polarization, collimation, directionality, and spatial uniformity. These parameters significantly affect the spatial distribution and population of trapped atoms, directly influencing the signal-to-noise ratio (SNR) of the Ramsey interference signal. Moreover, the number of detected atoms determines the quantum projection noise limit, a key factor of the clock’s second-level frequency stability. To enhance the atom detection efficiency, the collimator tubes were meticulously designed and optimized to improve their collimation, directionality, and uniformity. Following precise alignment, the divergence angle of the output laser beam from each of the six collimators was reduced to below 0.1 mrad (collimation), the angular deviation between the output laser beam and the mechanical axis of the collimator was minimized to less than 0.1′ (directionality), and the spatial offset between the center of the output laser spot and the mechanical center of the collimator was confined to within 2 mm (uniformity). In comparison to its predecessor, NTSC-RbF1, the quantum projection noise contribution to the clock's second-level frequency stability was reduced from 1.39×10-13 to 8.26×10-14.
The realisation of cold and slow atomic beams has opened the way to a series of precision measurements of high scientific interest, as atom interferometry, Bose-Einstein Condensation and atomic fountain clocks. The latter are used since several years as reference clocks, given the high performance that they can reach both in accuracy and stability. The common philosophy in the construction of atomic fountains has been the pulsed technique, where an atoms sample is launched vertically and then falls down under the effect of the gravity. The Observatoire de Neuchâtel had a different approach and has built a fountain clock (FOCS1) operating in a continuous mode. This technique offers two main advantages: the diminution of the undesirable effects due to the atomic density (e.g. collisions between the atoms and cavity pulling) and to the noise of the local oscillator (intermodulation effect). To take full advantage of the continuous fountain approach however, we need to increase the atomic flux. The techniques chosen to reach this goal are an efficient transverse collimation together with more atoms to begin with. Here we report on a study of different transverse collimation techniques performed in a two-dimensional phase stable optical lattice (namely gray molasses and magnetically induced laser cooling) as well as the development and characterisation of a 2D-magneto-optical trap used to load the fountain. Best performances are reached in a 2D+-MOT configuration of such a pre-source, for which we detect an atomic flux 20 times greater than the one measured when the fountain is loaded by a Cs vapour. This gain could improve the atomic clock stability by a factor 6. An even better stability is expected after introducing a pre-cooling stage before performing the transverse collimation. This new configuration is currently under investigation and will be implemented in a second continuous fountain (FOCS2).
The realisation of cold and slow atomic beams has opened the way to a series of precision measurements of high scientific interest, as atom interferometry, Bose-Einstein Condensation and atomic fountain clocks. The latter are used since several years as reference clocks, given the high performance that they can reach both in accuracy and stability. The common philosophy in the construction of atomic fountains has been the pulsed technique, where an atoms sample is launched vertically and then falls down under the effect of the gravity. The Observatoire de Neuchâtel had a different approach and has built a fountain clock (FOCS1) operating in a continuous mode. This technique offers two main advantages: the diminution of the undesirable effects due to the atomic density (e.g. collisions between the atoms and cavity pulling) and to the noise of the local oscillator (intermodulation effect). To take full advantage of the continuous fountain approach however, we need to increase the atomic flux. The techniques chosen to reach this goal are an efficient transverse collimation together with more atoms to begin with. Here we report on a study of different transverse collimation techniques performed in a two-dimensional phase stable optical lattice (namely gray molasses and magnetically induced laser cooling) as well as the development and characterisation of a 2D-magneto-optical trap used to load the fountain. Best performances are reached in a 2D+-MOT configuration of such a pre-source, for which we detect an atomic flux 20 times greater than the one measured when the fountain is loaded by a Cs vapour. This gain could improve the atomic clock stability by a factor 6. An even better stability is expected after introducing a pre-cooling stage before performing the transverse collimation. This new configuration is currently under investigation and will be implemented in a second continuous fountain (FOCS2).
A new technique for laser-cooling atoms in a cesium atomic fountain frequency standard relies on recirculation of laser light through the atom-collection region of the fountain. The recirculation, accomplished by means of reflections from multiple fixed beam-splitter cubes, is such that each of two laser beams makes three passes. As described below, this recirculation scheme offers several advantages over prior designs, including simplification of the laser system, greater optical power throughput, fewer optical and electrical connections, and simplification of beam power balancing. A typical laser-cooled cesium fountain requires the use of six laser beams arranged as three orthogonal pairs of counter-propagating beams to decelerate the atoms and hold them in a three-dimensional optical trap in vacuum. Typically, these trapping/cooling beams are linearly polarized and are positioned and oriented so that (1) counter-propagating beams in each pair have opposite linear polarizations and (2) three of the six orthogonal beams have the sum of their propagation directions pointing up, while the other three have the sum of their propagation directions pointing down. In a typical prior design, two lasers are used - one to generate the three "up" beams, the other to generate the three "down" beams. For this purpose, the output of each laser is split three ways, then the resulting six beams are delivered to the vacuum system, independently of each other, via optical fibers. The present recirculating design also requires two lasers, but the beams are not split before delivery. Instead, only one "up" beam and one oppositely polarized "down" beam are delivered to the vacuum system, and each of these beams is sent through the collection region three times. The polarization of each beam on each pass through the collection region is set up to yield the same combination of polarization and propagation directions as described above. In comparison with the prior design, the present recirculating design utilizes the available laser light more efficiently, making it possible to trap more atoms at a given laser power or the same number of atoms at a lower laser power. The present design is also simpler in that it requires fewer optical fibers, fiber couplings, and collimators, and fewer photodiodes for monitoring beam powers. Additionally, the present design alleviates the difficulty of maintaining constant ratios among power levels of the beams within each "up" or "down" triplet.
To improve the signal to noise ratio (SNR) and the short-term stability of cesium atomic fountain clocks, the work of two-laser optical pumping is presented theoretically and experimentally. The short-term stability of the NIM6 fountain clock has been improved by preparing more cold atoms in the | F = 4, mF = 0〉 clock state with a shortened cycle time. Two π-polarized laser beams overlapped in the horizontal plane have been applied after launching, one is resonant with | F = 4〉 → | F′ = 4〉 transition and the other is resonant with | F = 3〉 → | F′ = 4〉 transition. With optical pumping, the population accumulated in the | mF = 0〉 clock state is improved from 11% to 63%, and the detection signal is increased by a factor of 4.2, the SNR of the clock transition probability and the short-term stability are also improved accordingly.
We propose an atomic fountain clock with a truncated cold atomic beam to achieve both a low collisional frequency shift and high frequency stability. In this clock, the launching velocity of a cold atomic beam can be swept to reduce the atomic density in the interrogation region for the Ramsey resonance and to increase the atomic density in the detection region. Before the top of the beam arrives at the interrogation region, the cold atomic beam is truncated by turning off the cooling laser beams to remove the unnecessary light shift. The atomic density in the interrogation region is theoretically evaluated to be 0.04 times that in an ordinary atomic fountain with optical molasses for the same number of detected atoms. The frequency stability limit due to quantum projection noise is calculated to reach $6.4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$ in 1 s from the number of detected atoms while the fractional collisional shift is estimated to be $~\ensuremath{-}2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$.
The accelerated development of laser methods for manipulating the internal state and motion of atoms, and the recent primary evaluation in France of a cesium frequency standard using cold atoms in an atomic fountain configuration, allow the frontiers of time metrology, accuracy, and stability to be pushed near parts in the 1016 level, a factor of 100 over the present primary laboratory clocks. These positive results revived the development of more accurate cesium atomic clocks, and the Institute of National Measurement Standards (INMS), of the National Research Council of Canada (NRC) is undertaking a cesium-fountain project aimed at reaching these new levels of accuracy and stability. This paper reviews its present status. To appreciate the considerable impact of cold atoms in time and frequency metrology, we begin by recalling the background principles of traditional cesium frequency standards, their typical performance and main limitations. After introducing the important theoretical results essential to understanding the techniques of laser cooling and magneto-optical trapping, we focus on describing the characterization and control of our magneto-optical trap (MOT) and report the parameters that allow us to fill the trap with a few million atoms in less than a second and cool them to a temperature lower than 5 muK using optical molasses. We will describe the specifics of our cesium-fountain prototype, which operates with a 2-dimensional moving molasses. This special configuration is applicable for multipulse operation of the fountain, which can greatly relax the local oscillator requirements for time keeping. Finally, progress toward our objective of launching cooled atoms, at a rate of one ensemble per second, at speeds of 7 m/s, for a fountain with an interrogation time of about 1 s, will be analysed.PACS Nos.: 06.20, 06.30, and 32.80P