Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Atomic References for Measuring Small Accelerations

Lute Maleki, Nan Yu

Published Mar 1, 2009• 3 citations
OpenAlex

Abstract

Accelerometer systems that would combine the best features of both conventional (e.g., mechanical) accelerometers and atom interferometer accelerometers (AIAs) have been proposed. These systems are intended mainly for use in scientific research aboard spacecraft but may also be useful on Earth in special military, geological, and civil-engineering applications. Conventional accelerometers can be sensitive, can have high dynamic range, and can have high frequency response, but they lack accuracy and long-term stability. AIAs have low frequency response, but they offer high sensitivity, and high accuracy for measuring small accelerations. In a system according to the proposal, a conventional accelerometer would be used to perform short-term measurements of higher-frequency components of acceleration, while an AIA would be used to provide consistent calibration of, and correction of errors in, the measurements of the conventional accelerometer in the lower-frequency range over the long term. A brief description of an AIA is prerequisite to a meaningful description of a system according to the proposal. An AIA includes a retroreflector next to one end of a cell that contains a cold cloud of atoms in an ultrahigh vacuum. The atoms in the cloud are in free fall. The retroreflector is mounted on the object, the acceleration of which is to be measured. Raman laser beams are directed through the cell from the end opposite the retroreflector, then pass back through the cell after striking the retroreflector. The Raman laser beams together with the cold atoms measure the relative acceleration, through the readout of the AIA, between the cold atoms and the retroreflector.

Related papers

Development of compact cold-atom sensors for inertial navigation

Baptiste Battelier, B. Barrett, Lauriane Fouché +7 more

Inertial sensors based on cold atom interferometry exhibit many interesting features for applications related to inertial navigation, particularly in terms of sensitivity and long-term stability. However, at present the typical atom interferometer is still very much an experiment—consisting of a bulky, static apparatus with a limited dynamic range and high sensitivity to environmental effects. To be compliant with mobile applications further development is needed. In this work, we present a compact and mobile experiment, which we recently used to achieve the first inertial measurements with an atomic accelerometer onboard an aircraft. By integrating classical inertial sensors into our apparatus, we are able to operate the atomic sensor well beyond its standard operating range, corresponding to half of an interference fringe. We report atom-based acceleration measurements along both the horizontal and vertical axes of the aircraft with one-shot sensitivities of 2.3 × 10−4 g over a range of ∼ 0.1 g. The same technology can be used to develop cold-atom gyroscopes, which could surpass the best optical gyroscopes in terms of long-term sensitivity. Our apparatus was also designed to study multi-axis atom interferometry with the goal of realizing a full inertial measurement unit comprised of the three axes of acceleration and rotation. Finally, we present a compact and tunable laser system, which constitutes an essential part of any cold-atom-based sensor. The architecture of the laser is based on phase modulating a single fiber-optic laser diode, and can be tuned over a range of 1 GHz in less than 200 μs.

arXiv:1605.02454•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 29, 2016•84 citations

Phase stabilization of laser beams in a cold atom accelerometer

Nicole Byrne

A cold atom accelerometer measures the displacement of a proof mass of laser cooled atoms with respect to an instrument reference frame. The cold atom interferometer's reference frame is defined by a pair of specially prepared, counter-propagating laser beams, that measure inertially induced atom displacements with nm scale resolution. This corresponds to acceleration sensitivities comparable to state of the art electro-mechanical accelerometers. In dynamic environments, sensitivity is limited by the stability of the relative laser phase of the two interrogation laser beams, which is adversely affected by vibrations and temperature fluctuations of the interrogation beam optics. Without an independent measurement, the cold atom interferometer cannot distinguish platform acceleration from laser phase fluctuations, which thus are a potentially serious source of error. In this thesis, a Michelson optical interferometer and an optical feedback loop were used to stabilize the relative phase of the interrogation laser beams in a cold atom accelerometer. A digital controller stabilized the relative phase via an electro-optic phase modulator. This control loop's bandwidth encompasses 98.8% of the noise power as determined from the power spectral density of the open loop 795nm Michelson signal. Increasing the controller bandwidth would gain the system marginal improvement in noise reduction. At an atom interferometer dwell time of 1 msec, active laser phase stabilization improved the atom interferometer sensitivity; at an atom interferometer dwell time of 8msec, an improvement was no longer evident. Improvements to the laser phase stabilization system are proposed to increase atom interferometer stability at longer dwell times.

•Jan 1, 2014•0 citations

Accelerometry via reflective atom interferometry

Fabian Spallek, Johannes Fiedler

Abstract We present a reflective atom-interferometric approach to acceleration sensing, in which matter waves are coherently split and recombined solely through diffraction from nanostructured surfaces. Unlike light-pulse atom interferometers, the method is completely laser-free and operates on millisecond time scales, enabling compact and robust sensor architectures. Two readout strategies are explored: (i) the shift of the diffracted output angles, and (ii) the interferometric phase modulation generated by three successive reflections within the device. Using analytical models for diffraction from a moving lattice, we compute the sensitivity to lateral and normal accelerations. The interferometric mode exhibits a pronounced amplification of small velocity changes, reaching sensitivities as low as $$10^{-10}\,{\text {g}}$$ 10 - 10 g for slow atoms and large incidence angles. The response is intrinsically stronger for lateral than for normal accelerations due to the asymmetry of the diffraction paths. Comparisons with existing technologies show that the reflective interferometer fills a gap between MEMS-based accelerometers and large light-pulse atom interferometers, offering high sensitivity, continuous readout, and a fully passive beam-splitting mechanism. These results identify reflective interferometry as a promising platform for next-generation quantum accelerometers.

The European Physical Journal D•Oct 1, 2026•0 citations

An atom interferometer for measuring horizontal accelerations

Jimmy Stammers

Matter-wave interferometry has enabled high precision measurements of inertial forces such as gravity and the Coriolis force. This is facilitated by the long-term stability of the physical properties of atoms and lasers. Recent experiments have demonstrated the operation of portable, robust sensors using atom interferometry. This has potential uses in the context of inertial navigation, where conventional devices suffer from long-term drifts due to bias instability. Furthermore, determining position via dead reckoning requires minimisation of dead time between measurements. This thesis presents the development of an atom interferometer for measuring horizontal accelerations. In this configuration, gravity induces motion across the laser wavefront, which constrains the tolerable level of wavefront distortions. Effective control of the experiment allows the interferometer to be operated at a rate of 4 Hz. A cold ensemble of 10^6 atoms in the same internal state is prepared in 150 ms. The interferometer operates using a sequence of three laser pulses separated by T= 25 ms to achieve sensitivity to horizontal accelerations. Combining this with a classical accelerometer provides a method of correcting for vibration-induced noise, as well as determining the interferometer fringe order. After an integration time of 40 s, the sensitivity to horizontal accelerations is better than 3^-6 m s^-2. Effects which limit this sensitivity are discussed.

•Nov 1, 2018•6 citations

Hybridizing matter-wave and classical accelerometers

J. Lautier, Laurent Volodimer, T. Hardin +4 more

We demonstrate a hybrid accelerometer that benefits from the advantages of both conventional and atomic sensors in terms of bandwidth (DC to 430 Hz) and long term stability. First, the use of a real time correction of the atom interferometer phase by the signal from the classical accelerometer enables to run it at best performance without any isolation platform. Second, a servo-lock of the DC component of the conventional sensor output signal by the atomic one realizes a hybrid sensor. This method paves the way for applications in geophysics and in inertial navigation as it overcomes the main limitation of atomic accelerometers, namely, the dead times between consecutive measurements.

arXiv:1410.0050•Applied Physics Letters•Oct 6, 2014•169 citations

High-Sensitivity Absolute Atomic Gravimeter

Christine Guerlin, Tristan Farah, Anne Louchet-Chauvet +2 more

Cold atom free-fall interferometers now realize state-of-the-art precision inertial sensors, opening perspectives towards embedded devices for applications and fundamental physics tests on earth and in space. The acceleration of gravity can be measured in a stimulated Raman transition interferometer where the acceleration under gravity of a cloud of freely falling atoms is sensed by three Raman pulses allowing to split, reflect and interfere atomic wave packets [1]. The gravimeter developped at SYRTE allows to measure the acceleration of gravity at state-of-the-art performances compared to the best classical absolute gravimeters, with a sensitivity of 2×10−8g over 1s and an exactitude of 5×10−9 g [2]. This exactitude is currently limited by wavefront aberrations of the lasers, sampled by residual transverse trajectories of the molasse-cooled cloud over the free fall. Unbalanced transverse trajectories will also bias the measurement due to Coriolis effect [3]. We will investigate the use of a colder atom source to reduce these systematic effects, by implementing Bose-Einstein condensation of the initial cloud, allowing both better position control and better focusing of our source.

Research in Optical Sciences•Jan 1, 2012•0 citations
Accelerometer systems that would combine the best features of both conventional (e.g., mechanical) accelerometers and atom interferometer accelerometers (AIAs) have been proposed. These systems are intended mainly for use in scientific research aboard spacecraft but may also be useful on Earth in special military, geological, and civil-engineering applications. Conventional accelerometers can be sensitive, can have high dynamic range, and can have high frequency response, but they lack accuracy and long-term stability. AIAs have low frequency response, but they offer high sensitivity, and high accuracy for measuring small accelerations. In a system according to the proposal, a conventional accelerometer would be used to perform short-term measurements of higher-frequency components of acceleration, while an AIA would be used to provide consistent calibration of, and correction of errors in, the measurements of the conventional accelerometer in the lower-frequency range over the long term. A brief description of an AIA is prerequisite to a meaningful description of a system according to the proposal. An AIA includes a retroreflector next to one end of a cell that contains a cold cloud of atoms in an ultrahigh vacuum. The atoms in the cloud are in free fall. The retroreflector is mounted on the object, the acceleration of which is to be measured. Raman laser beams are directed through the cell from the end opposite the retroreflector, then pass back through the cell after striking the retroreflector. The Raman laser beams together with the cold atoms measure the relative acceleration, through the readout of the AIA, between the cold atoms and the retroreflector.
Inertial sensors based on cold atom interferometry exhibit many interesting features for applications related to inertial navigation, particularly in terms of sensitivity and long-term stability. However, at present the typical atom interferometer is still very much an experiment—consisting of a bulky, static apparatus with a limited dynamic range and high sensitivity to environmental effects. To be compliant with mobile applications further development is needed. In this work, we present a compact and mobile experiment, which we recently used to achieve the first inertial measurements with an atomic accelerometer onboard an aircraft. By integrating classical inertial sensors into our apparatus, we are able to operate the atomic sensor well beyond its standard operating range, corresponding to half of an interference fringe. We report atom-based acceleration measurements along both the horizontal and vertical axes of the aircraft with one-shot sensitivities of 2.3 × 10−4 g over a range of ∼ 0.1 g. The same technology can be used to develop cold-atom gyroscopes, which could surpass the best optical gyroscopes in terms of long-term sensitivity. Our apparatus was also designed to study multi-axis atom interferometry with the goal of realizing a full inertial measurement unit comprised of the three axes of acceleration and rotation. Finally, we present a compact and tunable laser system, which constitutes an essential part of any cold-atom-based sensor. The architecture of the laser is based on phase modulating a single fiber-optic laser diode, and can be tuned over a range of 1 GHz in less than 200 μs.
A cold atom accelerometer measures the displacement of a proof mass of laser cooled atoms with respect to an instrument reference frame. The cold atom interferometer's reference frame is defined by a pair of specially prepared, counter-propagating laser beams, that measure inertially induced atom displacements with nm scale resolution. This corresponds to acceleration sensitivities comparable to state of the art electro-mechanical accelerometers. In dynamic environments, sensitivity is limited by the stability of the relative laser phase of the two interrogation laser beams, which is adversely affected by vibrations and temperature fluctuations of the interrogation beam optics. Without an independent measurement, the cold atom interferometer cannot distinguish platform acceleration from laser phase fluctuations, which thus are a potentially serious source of error. In this thesis, a Michelson optical interferometer and an optical feedback loop were used to stabilize the relative phase of the interrogation laser beams in a cold atom accelerometer. A digital controller stabilized the relative phase via an electro-optic phase modulator. This control loop's bandwidth encompasses 98.8% of the noise power as determined from the power spectral density of the open loop 795nm Michelson signal. Increasing the controller bandwidth would gain the system marginal improvement in noise reduction. At an atom interferometer dwell time of 1 msec, active laser phase stabilization improved the atom interferometer sensitivity; at an atom interferometer dwell time of 8msec, an improvement was no longer evident. Improvements to the laser phase stabilization system are proposed to increase atom interferometer stability at longer dwell times.
Abstract We present a reflective atom-interferometric approach to acceleration sensing, in which matter waves are coherently split and recombined solely through diffraction from nanostructured surfaces. Unlike light-pulse atom interferometers, the method is completely laser-free and operates on millisecond time scales, enabling compact and robust sensor architectures. Two readout strategies are explored: (i) the shift of the diffracted output angles, and (ii) the interferometric phase modulation generated by three successive reflections within the device. Using analytical models for diffraction from a moving lattice, we compute the sensitivity to lateral and normal accelerations. The interferometric mode exhibits a pronounced amplification of small velocity changes, reaching sensitivities as low as 10−10 g10^{-10}\,{\text {g}}10−10g 10 - 10 g for slow atoms and large incidence angles. The response is intrinsically stronger for lateral than for normal accelerations due to the asymmetry of the diffraction paths. Comparisons with existing technologies show that the reflective interferometer fills a gap between MEMS-based accelerometers and large light-pulse atom interferometers, offering high sensitivity, continuous readout, and a fully passive beam-splitting mechanism. These results identify reflective interferometry as a promising platform for next-generation quantum accelerometers.
Matter-wave interferometry has enabled high precision measurements of inertial forces such as gravity and the Coriolis force. This is facilitated by the long-term stability of the physical properties of atoms and lasers. Recent experiments have demonstrated the operation of portable, robust sensors using atom interferometry. This has potential uses in the context of inertial navigation, where conventional devices suffer from long-term drifts due to bias instability. Furthermore, determining position via dead reckoning requires minimisation of dead time between measurements. This thesis presents the development of an atom interferometer for measuring horizontal accelerations. In this configuration, gravity induces motion across the laser wavefront, which constrains the tolerable level of wavefront distortions. Effective control of the experiment allows the interferometer to be operated at a rate of 4 Hz. A cold ensemble of 10^6 atoms in the same internal state is prepared in 150 ms. The interferometer operates using a sequence of three laser pulses separated by T= 25 ms to achieve sensitivity to horizontal accelerations. Combining this with a classical accelerometer provides a method of correcting for vibration-induced noise, as well as determining the interferometer fringe order. After an integration time of 40 s, the sensitivity to horizontal accelerations is better than 3^-6 m s^-2. Effects which limit this sensitivity are discussed.
We demonstrate a hybrid accelerometer that benefits from the advantages of both conventional and atomic sensors in terms of bandwidth (DC to 430 Hz) and long term stability. First, the use of a real time correction of the atom interferometer phase by the signal from the classical accelerometer enables to run it at best performance without any isolation platform. Second, a servo-lock of the DC component of the conventional sensor output signal by the atomic one realizes a hybrid sensor. This method paves the way for applications in geophysics and in inertial navigation as it overcomes the main limitation of atomic accelerometers, namely, the dead times between consecutive measurements.
Cold atom free-fall interferometers now realize state-of-the-art precision inertial sensors, opening perspectives towards embedded devices for applications and fundamental physics tests on earth and in space. The acceleration of gravity can be measured in a stimulated Raman transition interferometer where the acceleration under gravity of a cloud of freely falling atoms is sensed by three Raman pulses allowing to split, reflect and interfere atomic wave packets [1]. The gravimeter developped at SYRTE allows to measure the acceleration of gravity at state-of-the-art performances compared to the best classical absolute gravimeters, with a sensitivity of 2×10−8g over 1s and an exactitude of 5×10−9 g [2]. This exactitude is currently limited by wavefront aberrations of the lasers, sampled by residual transverse trajectories of the molasse-cooled cloud over the free fall. Unbalanced transverse trajectories will also bias the measurement due to Coriolis effect [3]. We will investigate the use of a colder atom source to reduce these systematic effects, by implementing Bose-Einstein condensation of the initial cloud, allowing both better position control and better focusing of our source.