Intrinsic Vectorial Gradiometry via Quantum Control of a Spin-based Sensor — E8 Intelligence Research

Andrew Stewart Caldin

Published Nov 9, 2026• 0 citations
Publisher

Abstract

Gradiometry provides a versatile alternative to passive environmental shielding in quasi-static magnetometry, effectively suppressing background noise through differential signal extraction. Nevertheless, traditional implementations rely on multi-sensor architectures restricted to spatial gradients, where subtracting signals from independent detectors involves imperfect suppression of common-mode noise and artifacts, limiting their sensitivity. To overcome these limitations, we introduce a quantum control sequence that enables intrinsic temporal and spatial vectorial gradiometry of magnetic fields using a single quantum sensor. Our method provides direct access to first and higher-order derivatives of the magnetic field and extended applicability via auxiliary nuclear spin memory. We showcase this protocol on an ensemble of nitrogen-vacancy (NV) centers in diamond and combine it with mechanical control to realize high-precision differential sensing. Through detailed numerical simulatio Author: Andrew Stewart Caldin, Independent Researcher, UK. Part of the E8 Intelligence Research series. Platform: e8intelligence.com

DOI
10.5281/zenodo.24075566

Related papers

Intrinsic Vectorial Gradiometry via Quantum Control of a Spin-based Sensor

Jaime García Oliván, Pablo Acedo, Oliver T. Whaites +1 more

Gradiometry provides a versatile alternative to passive environmental shielding in quasi-static magnetometry, effectively suppressing background noise through differential signal extraction. Nevertheless, traditional implementations rely on multi-sensor architectures restricted to spatial gradients, where subtracting signals from independent detectors involves imperfect suppression of common-mode noise and artifacts, limiting their sensitivity. To overcome these limitations, we introduce a quantum control sequence that enables intrinsic temporal and spatial vectorial gradiometry of magnetic fields using a single quantum sensor. Our method provides direct access to first and higher-order derivatives of the magnetic field and extended applicability via auxiliary nuclear spin memory. We showcase this protocol on an ensemble of nitrogen-vacancy (NV) centers in diamond and combine it with mechanical control to realize high-precision differential sensing. Through detailed numerical simulations, we demonstrate the performance of our scheme in two critical DC magnetometry applications: (i) vector magnetic anomaly detection and (ii) non-invasive gradiometry of neuronal action potentials.

quant-pharXiv:2609.21776•Sep 21, 2026•0 citations

Nanoscale Vector dc Magnetometry via Ancilla-Assisted Frequency Up-Conversion

Yi-Xiang Liu, Ashok Ajoy, Paola Cappellaro

Sensing static magnetic fields with high sensitivity and spatial resolution is critical to many applications in fundamental physics, bioimaging, and materials science. Even more beneficial would be full vector magnetometry with nanoscale spatial resolution. Several versatile magnetometry platforms have emerged over the past decade, such as electronic spins associated with nitrogen vacancy (NV) centers in diamond. Achieving vector magnetometry has, however, often required using an ensemble of sensors or degrading the sensitivity. Here we introduce a hybrid magnetometry platform, consisting of a sensor and an ancillary qubit, that allows vector magnetometry of static fields. While more generally applicable, we demonstrate the method for an electronic NV sensor and a nuclear spin qubit. In particular, sensing transverse fields relies on frequency up-conversion of the dc fields through the ancillary qubit, allowing quantum lock-in detection with low-frequency noise rejection. In combination with the Ramsey detection of longitudinal fields, our frequency up-conversion scheme delivers a sensitive technique for vector dc magnetometry at the nanoscale.

arXiv:1611.04691•Physical Review Letters•Mar 13, 2019•64 citations

Nanoscale covariance magnetometry with diamond quantum sensors

Jared Rovny, Zhiyang Yuan, Mattias Fitzpatrick +6 more

Nitrogen vacancy (NV) centers in diamond are atom-scale defects that can be used to sense magnetic fields with high sensitivity and spatial resolution. Typically, the magnetic field is measured by averaging sequential measurements of single NV centers, or by spatial averaging over ensembles of many NV centers, which provides mean values that contain no nonlocal information about the relationship between two points separated in space or time. Here, we propose and implement a sensing modality whereby two or more NV centers are measured simultaneously, and we extract temporal and spatial correlations in their signals that would otherwise be inaccessible. We demonstrate measurements of correlated applied noise using spin-to-charge readout of two NV centers and implement a spectral reconstruction protocol for disentangling local and nonlocal noise sources.

arXiv:2209.08703•Science•Dec 22, 2022•81 citations

New Quantum Sensing Modalities of Nitrogen-Vacancy Centers

Qiu, Ziwei

The recent decade has witnessed exciting developments in quantum science and technology. Quantum sensing is a rapidly growing branch, which exploits the fragility of quantum systems to detect small external signals. The extreme control at the single-atom level and the remarkably long coherence time of engineered quantum systems enable unprecedented sensitivity and precision, beating the performance of classical techniques. The nitrogen-vacancy (NV) center in diamond is one of the most promising quantum sensors. Its unique advantages have attracted considerable attention, including a long spin coherence time throughout a broad temperature range, nanoscale resolution limited by the sensor-sample distance, convenient optical control of its spin states and remarkably versatile sensing capabilities. Its properties are well studied under a bias magnetic field oriented along its quantization axis. However, its sensing capabilities in the presence of an off-axis magnetic field are much less explored. My research aims to unlock the full potential of NV quantum sensor by developing new sensing modalities under a magnetic field acting perpendicular to the NV axis, and furthermore, integrating them into a scanning probe microscope. In this dissertation, I will report our progress toward building a scanning NV multimodal quantum imaging platform, which will open up exciting opportunities in measuring nanoscale phenomena. The first chapter provides an introduction to the background of quantum sensing with NV centers, followed by a discussion on its basic properties and established sensing techniques. The second and third chapters are dedicated to two experiments performed under a perpendicular magnetic field where traditional NV magnetometry based on the Zeeman effect fails. In the second chapter, I will introduce a new sensing strategy that uses the entanglement between the electron and nuclear spins to restore the magnetic field sensitivity under this unfavored condition. This allows us to sense small changes in the magnetic field angle relative to the NV axis, and to detect anisotropic magnetic noise in the local environment. In the third chapter, I will present our latest development of scanning NV electrometry, where a single NV at the apex of a diamond scanning probe images external alternating (AC) and direct (DC) electric fields with sub-100 nm resolution. In the last chapter, I will discuss our efforts on four experiments that were left unfinished. I will present the results we have achieved, analyze the challenges that we faced and propose potential solutions to overcome them.

•Jan 1, 2022•0 citations

Tailoring of measurement protocols for biomagnetic signals using quantum optimal control on NV centers in diamond

Isabell Jauch, Thomas Strohm, Tino Fuchs +1 more

Nitrogen-vacancy (NV) centers in diamond are a promising platform for ambient, high-spatial resolution magnetometry relevant to biological signals such as cardiac and muscle activity. One of the challenges is the development of pulse sequences tailored to biological signals in the near DC-range. The spatial environment of NV centers within the diamond lattice is highly complex, e.g. due to magnetic field inhomogeneities, limiting the sensors performance. To overcome these experimental constraints, quantum optimal control (QOC) aims at a precise manipulation of the systems dynamics via optimally shaped microwave pulses increasing the overall robustness of spin-based quantum sensors.

Optical and Quantum Sensing and Precision Metrology II•Mar 5, 2026•0 citations

Human Cardiac Measurements with Diamond Magnetometers

Muhib Omar, Magnus Benke, Shaowen Zhang +27 more

We demonstrate direct, non-invasive and non-contact detection of human cardiac magnetic signals using quantum sensors based on nitrogen-vacancy (NV) centers in diamond. Three configurations were employed recording magnetocardiography (MCG) signals in various shielded and unshielded environments. The signals were averaged over a few hundreds up to several thousands of heart beats to detect the MCG traces. The compact room-temperature NV sensors exhibit sensitivities of 6-26 pT/Hz^(1/2) with active sensing volumes below 0.5 mm^3, defining the performance level of the demonstrated MCG measurements. While the present signals are obtained by averaging, this performance already indicates a clear path toward single-shot MCG sensing. To move beyond shielded environments toward practical clinical use, strong noise suppression is required. To this end, we implement NV-based gradiometry and achieve efficient common-mode noise rejection, enabled by the intrinsically small sensing volume of NV sensors. Together, these multi-platform results obtained across diverse magnetic environments provide a solid foundation for translating quantum sensors into human medical diagnostics such as MCG and magnetoencephalography (MEG).

physics.med-phCross-listedarXiv:2601.18843•Jan 27, 2026
Gradiometry provides a versatile alternative to passive environmental shielding in quasi-static magnetometry, effectively suppressing background noise through differential signal extraction. Nevertheless, traditional implementations rely on multi-sensor architectures restricted to spatial gradients, where subtracting signals from independent detectors involves imperfect suppression of common-mode noise and artifacts, limiting their sensitivity. To overcome these limitations, we introduce a quantum control sequence that enables intrinsic temporal and spatial vectorial gradiometry of magnetic fields using a single quantum sensor. Our method provides direct access to first and higher-order derivatives of the magnetic field and extended applicability via auxiliary nuclear spin memory. We showcase this protocol on an ensemble of nitrogen-vacancy (NV) centers in diamond and combine it with mechanical control to realize high-precision differential sensing. Through detailed numerical simulatio Author: Andrew Stewart Caldin, Independent Researcher, UK. Part of the E8 Intelligence Research series. Platform: e8intelligence.com
Gradiometry provides a versatile alternative to passive environmental shielding in quasi-static magnetometry, effectively suppressing background noise through differential signal extraction. Nevertheless, traditional implementations rely on multi-sensor architectures restricted to spatial gradients, where subtracting signals from independent detectors involves imperfect suppression of common-mode noise and artifacts, limiting their sensitivity. To overcome these limitations, we introduce a quantum control sequence that enables intrinsic temporal and spatial vectorial gradiometry of magnetic fields using a single quantum sensor. Our method provides direct access to first and higher-order derivatives of the magnetic field and extended applicability via auxiliary nuclear spin memory. We showcase this protocol on an ensemble of nitrogen-vacancy (NV) centers in diamond and combine it with mechanical control to realize high-precision differential sensing. Through detailed numerical simulations, we demonstrate the performance of our scheme in two critical DC magnetometry applications: (i) vector magnetic anomaly detection and (ii) non-invasive gradiometry of neuronal action potentials.
Sensing static magnetic fields with high sensitivity and spatial resolution is critical to many applications in fundamental physics, bioimaging, and materials science. Even more beneficial would be full vector magnetometry with nanoscale spatial resolution. Several versatile magnetometry platforms have emerged over the past decade, such as electronic spins associated with nitrogen vacancy (NV) centers in diamond. Achieving vector magnetometry has, however, often required using an ensemble of sensors or degrading the sensitivity. Here we introduce a hybrid magnetometry platform, consisting of a sensor and an ancillary qubit, that allows vector magnetometry of static fields. While more generally applicable, we demonstrate the method for an electronic NV sensor and a nuclear spin qubit. In particular, sensing transverse fields relies on frequency up-conversion of the dc fields through the ancillary qubit, allowing quantum lock-in detection with low-frequency noise rejection. In combination with the Ramsey detection of longitudinal fields, our frequency up-conversion scheme delivers a sensitive technique for vector dc magnetometry at the nanoscale.
Nitrogen vacancy (NV) centers in diamond are atom-scale defects that can be used to sense magnetic fields with high sensitivity and spatial resolution. Typically, the magnetic field is measured by averaging sequential measurements of single NV centers, or by spatial averaging over ensembles of many NV centers, which provides mean values that contain no nonlocal information about the relationship between two points separated in space or time. Here, we propose and implement a sensing modality whereby two or more NV centers are measured simultaneously, and we extract temporal and spatial correlations in their signals that would otherwise be inaccessible. We demonstrate measurements of correlated applied noise using spin-to-charge readout of two NV centers and implement a spectral reconstruction protocol for disentangling local and nonlocal noise sources.
The recent decade has witnessed exciting developments in quantum science and technology. Quantum sensing is a rapidly growing branch, which exploits the fragility of quantum systems to detect small external signals. The extreme control at the single-atom level and the remarkably long coherence time of engineered quantum systems enable unprecedented sensitivity and precision, beating the performance of classical techniques. The nitrogen-vacancy (NV) center in diamond is one of the most promising quantum sensors. Its unique advantages have attracted considerable attention, including a long spin coherence time throughout a broad temperature range, nanoscale resolution limited by the sensor-sample distance, convenient optical control of its spin states and remarkably versatile sensing capabilities. Its properties are well studied under a bias magnetic field oriented along its quantization axis. However, its sensing capabilities in the presence of an off-axis magnetic field are much less explored. My research aims to unlock the full potential of NV quantum sensor by developing new sensing modalities under a magnetic field acting perpendicular to the NV axis, and furthermore, integrating them into a scanning probe microscope. In this dissertation, I will report our progress toward building a scanning NV multimodal quantum imaging platform, which will open up exciting opportunities in measuring nanoscale phenomena. The first chapter provides an introduction to the background of quantum sensing with NV centers, followed by a discussion on its basic properties and established sensing techniques. The second and third chapters are dedicated to two experiments performed under a perpendicular magnetic field where traditional NV magnetometry based on the Zeeman effect fails. In the second chapter, I will introduce a new sensing strategy that uses the entanglement between the electron and nuclear spins to restore the magnetic field sensitivity under this unfavored condition. This allows us to sense small changes in the magnetic field angle relative to the NV axis, and to detect anisotropic magnetic noise in the local environment. In the third chapter, I will present our latest development of scanning NV electrometry, where a single NV at the apex of a diamond scanning probe images external alternating (AC) and direct (DC) electric fields with sub-100 nm resolution. In the last chapter, I will discuss our efforts on four experiments that were left unfinished. I will present the results we have achieved, analyze the challenges that we faced and propose potential solutions to overcome them.
Nitrogen-vacancy (NV) centers in diamond are a promising platform for ambient, high-spatial resolution magnetometry relevant to biological signals such as cardiac and muscle activity. One of the challenges is the development of pulse sequences tailored to biological signals in the near DC-range. The spatial environment of NV centers within the diamond lattice is highly complex, e.g. due to magnetic field inhomogeneities, limiting the sensors performance. To overcome these experimental constraints, quantum optimal control (QOC) aims at a precise manipulation of the systems dynamics via optimally shaped microwave pulses increasing the overall robustness of spin-based quantum sensors.
We demonstrate direct, non-invasive and non-contact detection of human cardiac magnetic signals using quantum sensors based on nitrogen-vacancy (NV) centers in diamond. Three configurations were employed recording magnetocardiography (MCG) signals in various shielded and unshielded environments. The signals were averaged over a few hundreds up to several thousands of heart beats to detect the MCG traces. The compact room-temperature NV sensors exhibit sensitivities of 6-26 pT/Hz^(1/2) with active sensing volumes below 0.5 mm^3, defining the performance level of the demonstrated MCG measurements. While the present signals are obtained by averaging, this performance already indicates a clear path toward single-shot MCG sensing. To move beyond shielded environments toward practical clinical use, strong noise suppression is required. To this end, we implement NV-based gradiometry and achieve efficient common-mode noise rejection, enabled by the intrinsically small sensing volume of NV sensors. Together, these multi-platform results obtained across diverse magnetic environments provide a solid foundation for translating quantum sensors into human medical diagnostics such as MCG and magnetoencephalography (MEG).