Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Josephson Junctions: Fabrication and Applications for the Axion Dark Matter eXperiment

Jonah Sachs

Published Jan 1, 2025• 0 citations
Publisher

Abstract

The observation of axions could revolutionize the world of physics. Through microwave frequency cavity readout of the photons associated with these axions, the ADMX project at WashU utilizes multiple different forms of the Josephson junction (JJ), a superconductive circuit element. The physics behind the JJ are essential to understanding its operation for resonant cavity readout in addition to parametric amplification. Parametric amplifiers produced using JJs can approach the signal-to-noise ratio set by quantum mechanics, and prove essential for the amplification chain used by the ADMX experiment for axionic detection. The limits of these amplifiers are set by the noise tuning source used for calibration. This tuning device can be used to solve for the intrinsic gain and added noise present within the amplifier, which defines the effectiveness of the amplifier. Multiple models for a tuning device, based upon different models of noise, will be analyzed. Also discussed is the fabrication behind the tunnel junction-based noise source, in addition to the Dolan bridge procedure and corresponding physics used for design of experiment and parameter manipulation.

DOI
10.7936/9ydm-vw24

Related papers

Optimising the design of a broadband Josephson junction TWPA for axion dark matter search experiments

Javier Navarro Montilla, Boon-Kok Tan

Broadband ultra-low noise amplification is important for many fundamental physics experiments. In our case, we aim to develop a quantum limited Josephson Travelling Wave Parametric Amplifier (JTWPA) for dark matter search experiments. In this paper, we focus on the development of the JTWPA, in particular to optimise the performance of the amplifier with a simplified fabrication prospect. We present our methodology for the optimisation process, focusing on three important aspects, namely utilising the minimal number of tunnel junction required, maximising the operational bandwidth and achieving a 50 Ω characteristic impedance. We first explore the relations between the important circuit parameters of the JTWPA and its performance indicators. Using the information obtained, we perform our optimisation process to search for the optimal design parameters. We then compare the gain bandwidth performance of the different optimised models, and present our findings with further analyses. We demonstrate that our optimised model requires 4 less tunnel junctions compared to the conventional model, and we are able to improve the operational bandwidth by 68% while maintaining the characteristic impedance of the device at 50 Ω.

Quantum Technology: Driving Commercialisation of an Enabling Science•Oct 6, 2021•5 citations

Wideband SQUID Amplifiers for Axion Search Experiments

Andrei N. Matlashov, Yannis Kyriakos Semertzidis

The microwave cavity experiment for the dark matter axion search is based on the theoretical prediction that axions could convert into microwave photons inside a High-Q cavity immersed in a strong magnetic field. In such experiments a weak, of order 10-22 W, quasi-monochromatic microwave signal should be detected by scanning it in a very wide frequency range. The best cryogenic semiconductor amplifiers have the lowest noise temperature plateau of about 1.0 K even at significantly lower ambient temperature. Superconducting quantum interference devices, or SQUIDs, can work as microwave amplifiers with temperature noise close to the standard quantum limit that is about 50 mK at 1 GHz [1]. Previously designed SQUID-based high frequency amplifiers have narrow bandwidth due to a microstrip resonant input coil. It requires serial replacements of SQUID preamplifiers in order to scan wide frequency range. This procedure is complex and time consuming because of a large mass of hardware should be cooled down below 100 mK. For suitable amplification at high frequency a SQUID should be designed with the smallest possible Josephson junction capacitance, reasonably low SQUID loop inductance, and maximal steepness of the transfer function. Sub-micron size cross-type Josephson junctions have a very low capacitance of about 0.04 pF that is one order smaller than a capacitance of Josephson junctions fabricated using conventional window-type technology. Such junctions initially were designed and used at IPHT for low-frequency SQUID current sensors [2]. Slightly modified current sensors were tested as amplifiers at frequency range 0.5 – 5 GHz. They showed high gain and both wideband and resonant performance. In this paper we describe wideband SQUID microwave amplifiers fabricated at IPHT using sub-micron size Josephson junctions with very low capacitance.

International Conference on High Energy Physics (ICHEP)•Aug 2, 2019•0 citations

Fabrication of Josephson parameter amplifier and its application in squeezing vacuum fluctuations*

Pengtao Song, Xueyi Guo, Kai Xu +7 more

Josephson parameter amplifier (JPA) is a microwave signal amplifier device with near-quantum-limit-noise performance. It has important applications in scientific research fields such as quantum computing and dark matter detection. This work reports the fabrication and characterization of broadband JPA devices and their applications in multi-qubit readout and squeezing of vacuum state. We use a process in which transmission lines and electrodes are made of niobium thin film and aluminum Josephson junctions are made by Dolan bridge technique. We believe this process is more convenient than the process we used previously. The whole production process adopts electron beam lithography technology to ensure high structural resolution. The test result shows that the gain value of the manufactured JPA can exceed 15 dB, and the amplification bandwidth is about 400 MHz. The noise temperature is about 400 mK at the working frequency of 6.2 GHz. The devices have been successfully used in experiments involving superconducting multi-qubit quantum processors. Furthermore, the device is applied to squeeze vacuum fluctuations and a squeezing level of 1.635 dB is achieved.

Chinese Physics B•Jun 3, 2021•1 citation

Parameter Optimization of Josephson Parametric Amplifiers Using a Heuristic Search Algorithm for Axion Haloscope Search

Young-Geun Kim, Junu Jeong, SungWoo Youn +5 more

The cavity haloscope is among the most widely adopted experimental platforms designed to detect dark matter axions with its principle relying on the conversion of axions into microwave photons in the presence of a strong magnetic field. The Josephson parametric amplifier (JPA), known for its quantum-limited noise characteristics, has been incorporated into the detection system to capture the weakly interacting axion signals. However, the performance of the JPA can be influenced by its environment, leading to the potential unreliability of a predefined parameter set obtained in a specific laboratory setting. Furthermore, conducting a broadband search requires the consecutive characterization of the amplifier across different tuning frequencies. To ensure more reliable measurements, we utilize the Nelder–Mead technique as a numerical search method to dynamically determine the optimal operating conditions. This heuristic search algorithm explores the multidimensional parameter space of the JPA, optimizing critical characteristics such as gain and noise temperature to maximize signal-to-noise ratios for a given experimental setup. Our study presents a comprehensive analysis of the properties of a flux-driven JPA to demonstrate the effectiveness of the algorithm. This approach contributes to ongoing efforts in axion dark matter research by offering an efficient method to enhance axion detection sensitivity through the optimized utilization of JPAs.

arXiv:2404.18345•Electronics•May 29, 2024•3 citations

Improving Amplification Bandwidth by Combining Josephson Parametric Amplifiers for Active Axion Search Experiments at IBS/CAPP

Sergey V. Uchaikin, Jinmyeong Kim, Boris I. Ivanov +8 more

Abstract The Center for Axion and Precision Physics Research at the Institute for Basic Science in Republic of Korea is home to multiple active axion search experiments using cavity haloscopes that operate within the frequency range of 1–6 GHz. The haloscopes convert axions to photons, resulting in an output power of about 10 $${^{-24}}$$ - 24 –10 $${^{-22}}$$ - 22 W. To detect such a small signal amidst noise, quantum-limited noise amplifiers and ultra-low-temperature environment (a few tenths of mK) are required for all critical readout components to minimize noise from all active and passive lossy components. Our primary objective is to achieve the highest possible scanning-frequency speed, which includes the time for maintenance and system calibration. This paper presents the development and operation of low-noise amplifiers for haloscope experiments targeting different frequency ranges and provides design, operational, and performance details of the amplifiers.

Journal of Low Temperature Physics•Jul 1, 2024•5 citations

Investigation of Resonant Activation in a Josephson Junction for Axion Search With Microwave Single Photon Detection

F. Chiarello, D. Alesini, D. Babusci +18 more

A growing interest in the detection of single microwave-photons has been stimulated by the search for light dark matter, such as Axions and Axion-like particles, together with the fast development of quantum technologies based on superconducting devices. Many solutions have been proposed in literature but most of them still fail to satisfy the tight requirements imposed by Dark Matter experiments. For instance, many have a large dark-count rate that still make parametric amplifiers a preferable choice. On the contrary, a device based on a current biased Josephson junction resonantly activated by the absorption of a microwave photon may have dark-counts rate down to the mHz level. Here, we report the experimental study of the resonant activation of an Al Josephson junction excited by continuous radiofrequency. The device under study consists of a chip with a transmission line terminated by an Al Josephson-junction, fabricated by shadow-mask evaporation technique. The sample-holder with the chip inside is hosted in a superconducting box and it is thermally anchored to the mixing-chamber plate of a dilution refrigerator at a temperature of about 15 mK. We measured the escape rates of the junction in different configurations of current bias and radiofrequency excitations. Response to continuous wave has been measured and interpreted within the RCSJ model. These results are used to optimize the design of a single microwave-photon detector.

IEEE Transactions on Applied Superconductivity•Feb 7, 2022•11 citations
The observation of axions could revolutionize the world of physics. Through microwave frequency cavity readout of the photons associated with these axions, the ADMX project at WashU utilizes multiple different forms of the Josephson junction (JJ), a superconductive circuit element. The physics behind the JJ are essential to understanding its operation for resonant cavity readout in addition to parametric amplification. Parametric amplifiers produced using JJs can approach the signal-to-noise ratio set by quantum mechanics, and prove essential for the amplification chain used by the ADMX experiment for axionic detection. The limits of these amplifiers are set by the noise tuning source used for calibration. This tuning device can be used to solve for the intrinsic gain and added noise present within the amplifier, which defines the effectiveness of the amplifier. Multiple models for a tuning device, based upon different models of noise, will be analyzed. Also discussed is the fabrication behind the tunnel junction-based noise source, in addition to the Dolan bridge procedure and corresponding physics used for design of experiment and parameter manipulation.
Broadband ultra-low noise amplification is important for many fundamental physics experiments. In our case, we aim to develop a quantum limited Josephson Travelling Wave Parametric Amplifier (JTWPA) for dark matter search experiments. In this paper, we focus on the development of the JTWPA, in particular to optimise the performance of the amplifier with a simplified fabrication prospect. We present our methodology for the optimisation process, focusing on three important aspects, namely utilising the minimal number of tunnel junction required, maximising the operational bandwidth and achieving a 50 Ω characteristic impedance. We first explore the relations between the important circuit parameters of the JTWPA and its performance indicators. Using the information obtained, we perform our optimisation process to search for the optimal design parameters. We then compare the gain bandwidth performance of the different optimised models, and present our findings with further analyses. We demonstrate that our optimised model requires 4 less tunnel junctions compared to the conventional model, and we are able to improve the operational bandwidth by 68% while maintaining the characteristic impedance of the device at 50 Ω.
The microwave cavity experiment for the dark matter axion search is based on the theoretical prediction that axions could convert into microwave photons inside a High-Q cavity immersed in a strong magnetic field. In such experiments a weak, of order 10-22 W, quasi-monochromatic microwave signal should be detected by scanning it in a very wide frequency range. The best cryogenic semiconductor amplifiers have the lowest noise temperature plateau of about 1.0 K even at significantly lower ambient temperature. Superconducting quantum interference devices, or SQUIDs, can work as microwave amplifiers with temperature noise close to the standard quantum limit that is about 50 mK at 1 GHz [1]. Previously designed SQUID-based high frequency amplifiers have narrow bandwidth due to a microstrip resonant input coil. It requires serial replacements of SQUID preamplifiers in order to scan wide frequency range. This procedure is complex and time consuming because of a large mass of hardware should be cooled down below 100 mK. For suitable amplification at high frequency a SQUID should be designed with the smallest possible Josephson junction capacitance, reasonably low SQUID loop inductance, and maximal steepness of the transfer function. Sub-micron size cross-type Josephson junctions have a very low capacitance of about 0.04 pF that is one order smaller than a capacitance of Josephson junctions fabricated using conventional window-type technology. Such junctions initially were designed and used at IPHT for low-frequency SQUID current sensors [2]. Slightly modified current sensors were tested as amplifiers at frequency range 0.5 – 5 GHz. They showed high gain and both wideband and resonant performance. In this paper we describe wideband SQUID microwave amplifiers fabricated at IPHT using sub-micron size Josephson junctions with very low capacitance.
Josephson parameter amplifier (JPA) is a microwave signal amplifier device with near-quantum-limit-noise performance. It has important applications in scientific research fields such as quantum computing and dark matter detection. This work reports the fabrication and characterization of broadband JPA devices and their applications in multi-qubit readout and squeezing of vacuum state. We use a process in which transmission lines and electrodes are made of niobium thin film and aluminum Josephson junctions are made by Dolan bridge technique. We believe this process is more convenient than the process we used previously. The whole production process adopts electron beam lithography technology to ensure high structural resolution. The test result shows that the gain value of the manufactured JPA can exceed 15 dB, and the amplification bandwidth is about 400 MHz. The noise temperature is about 400 mK at the working frequency of 6.2 GHz. The devices have been successfully used in experiments involving superconducting multi-qubit quantum processors. Furthermore, the device is applied to squeeze vacuum fluctuations and a squeezing level of 1.635 dB is achieved.
The cavity haloscope is among the most widely adopted experimental platforms designed to detect dark matter axions with its principle relying on the conversion of axions into microwave photons in the presence of a strong magnetic field. The Josephson parametric amplifier (JPA), known for its quantum-limited noise characteristics, has been incorporated into the detection system to capture the weakly interacting axion signals. However, the performance of the JPA can be influenced by its environment, leading to the potential unreliability of a predefined parameter set obtained in a specific laboratory setting. Furthermore, conducting a broadband search requires the consecutive characterization of the amplifier across different tuning frequencies. To ensure more reliable measurements, we utilize the Nelder–Mead technique as a numerical search method to dynamically determine the optimal operating conditions. This heuristic search algorithm explores the multidimensional parameter space of the JPA, optimizing critical characteristics such as gain and noise temperature to maximize signal-to-noise ratios for a given experimental setup. Our study presents a comprehensive analysis of the properties of a flux-driven JPA to demonstrate the effectiveness of the algorithm. This approach contributes to ongoing efforts in axion dark matter research by offering an efficient method to enhance axion detection sensitivity through the optimized utilization of JPAs.
Abstract The Center for Axion and Precision Physics Research at the Institute for Basic Science in Republic of Korea is home to multiple active axion search experiments using cavity haloscopes that operate within the frequency range of 1–6 GHz. The haloscopes convert axions to photons, resulting in an output power of about 10 −24{^{-24}}−24 - 24 –10 −22{^{-22}}−22 - 22 W. To detect such a small signal amidst noise, quantum-limited noise amplifiers and ultra-low-temperature environment (a few tenths of mK) are required for all critical readout components to minimize noise from all active and passive lossy components. Our primary objective is to achieve the highest possible scanning-frequency speed, which includes the time for maintenance and system calibration. This paper presents the development and operation of low-noise amplifiers for haloscope experiments targeting different frequency ranges and provides design, operational, and performance details of the amplifiers.
A growing interest in the detection of single microwave-photons has been stimulated by the search for light dark matter, such as Axions and Axion-like particles, together with the fast development of quantum technologies based on superconducting devices. Many solutions have been proposed in literature but most of them still fail to satisfy the tight requirements imposed by Dark Matter experiments. For instance, many have a large dark-count rate that still make parametric amplifiers a preferable choice. On the contrary, a device based on a current biased Josephson junction resonantly activated by the absorption of a microwave photon may have dark-counts rate down to the mHz level. Here, we report the experimental study of the resonant activation of an Al Josephson junction excited by continuous radiofrequency. The device under study consists of a chip with a transmission line terminated by an Al Josephson-junction, fabricated by shadow-mask evaporation technique. The sample-holder with the chip inside is hosted in a superconducting box and it is thermally anchored to the mixing-chamber plate of a dilution refrigerator at a temperature of about 15 mK. We measured the escape rates of the junction in different configurations of current bias and radiofrequency excitations. Response to continuous wave has been measured and interpreted within the RCSJ model. These results are used to optimize the design of a single microwave-photon detector.